- Water resistant. - Large size.

Similar documents
ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

The most Comprehensive, Reliable, Economical and Easy to use GAFCHROMIC film based RT QA system Updated Feb 08 BUSINESS UNIT OF ISP

A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3

State of the Art Film Dosimetry

Using Radiochromic Film Tips and Techniques

GAFCHROMIC. Therapy Dosimetry Media Models to

GafChromic EBT2 and EBT3 Films for Ball Cube II Phantom

Analysis of Post-exposure Density Growth in Radiochromic Film with Respect to the Radiation Dose

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Post-irradiation colouration of Gafchromic EBT radiochromic film

Homogeneity of GAFCHROMIC EBT2 film among different lot numbers

Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry

Energy dependence of radiochromic dosimetry films for use in radiotherapy verification

QA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion

Effective energy measurement using radiochromic film: application of a mobile scanner

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

AN ABSTRACT OF THE THESIS OF


IV. 4. An Optical Common-mode Rejection for Improving the Sensitivity Limit of a Radiochromic Imaging Film

PHYSICS QUESTIONNAIRE FORM

A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners

Characterisation of gafchromic EBT2 film for use in radiation therapy dosimetry

An Activity in Computed Tomography

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

An Activity in Computed Tomography

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

Development of new dosimeter for measuring dose distribution in CT

When small things matter. Small Field Dosimetry Application Guide

KODAK PROFESSIONAL PRO IMAGE II Paper

Hardware for High Energy Applications 30 October 2009

ISO 5-3 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 3: Spectral conditions

Cylindrical Ion Chambers Victoreen Model 550 Series

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

Summer Student project report

ISO INTERNATIONAL STANDARD

Introduction of a Single Chip TLD System for Patient Dosimetry

Cylindrical Ion Chambers

END-TO-END TESTING OF THE LEKSELL GAMMA KNIFE ICON SYSTEM

SCINTILLATING FIBER DOSIMETER ARRAY

Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

Test Equipment for Radiology and CT Quality Control Contents

A new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

SUBCHAPTER 14. THERAPEUTIC INSTALLATIONS

ALMD-CY3G-YZx02-DS100

Nathan Childress, Ph.D., DABR

ASMB-TTF0-0A20B-DS101

Put your best ideas forward.

CBT-120-UV LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. Applications

Grid patterns, spatial inter-scan variations and scanning reading repeatability in radiochromic film dosimetry

PSI Temperature Scanners

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Basically brilliant Vanceva White Collection. High-performance interlayers for laminated glass

ISO Cube Daily QA Package

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

Electronic Brachytherapy Sources. Thomas W. Rusch

Silicon Light Machines Patents

CBT-90-UV LEDs. CBT-90-UV CBT-120 Product Datasheet Preliminary. Features: Table of Contents. Applications

ASMB-KTF0-0A306-DS100

Nuclear Associates , , CT Head and Body Dose Phantom

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

CBT-90-UV-405 LEDs. CBT-90-UV-405 CBT-120 Product Datasheet. Features: Table of Contents. Applications

CARESTREAM INDUSTREX Digital Imaging Plates

Bridgelux Vesta Series Tunable White 9mm Array. Product Data Sheet DS152

IMAGELINK Diazo Duplicating Microfilms

KODAK VISION3 Color Digital Intermediate Film 5254 / 2254

BRANDON RICE UNIVERSITY OF FLORIDA

T h e P h a n t o m L a b o r a t o r y

Bridgelux Vesta Series Tunable White Linear. Product Data Sheet DS154

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

Prototype electron phantom for radiographic and radiochromic film dosimetry

Bridgelux Vesta Series Dim-To-Warm 9mm Array. Product Data Sheet DS150

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

NJDEP Medical Physicist s Radiographic QC Survey Registration Number:

KODAK High Speed Infrared Film

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Aim. Images for this section: Page 2 of 13

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Computer Output Microfilm Data Sheet

ISO Photography Intra-oral dental radiographic film and film packets Manufacturer specifications

Radiation transmission, leakage and beam penumbra measurements of a micro-multileaf collimator using GafChromic EBT film

Diazo C Microfilm 1957, 2957, 3957 Diazo D Microfilm 1956, 2956, 3956

SodiumStar 20/2 High Power cw Tunable Guide Star Laser

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

MaxRay Handheld X-ray Systems Operator Training Exam

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

Y11-DR Digital Radiography (DR) Image Quality

Ludlum Medical Physics

NOT FOR DISTRIBUTION JINST_083P_0914 v1

This is the author s version of a work that was submitted/accepted for publication in the following source:

Product Data Sheet DS92 BXRC-27x x x x x x x4001

HL6323MG. AlGaInP Laser Diode

CARESTREAM INDUSTREX Digital Imaging Plates

Transcription:

GAFCHROMIC EBT product brochure

GAFCHROMIC EBT FEATURES GAFCHROMIC EBT dosimetry film has been developed specifically to address the needs of the medical physicist and dosimetrist working in the radiotherapy environment. It is targeted toward applications in external beam radiotherapy, in particular, intensity modulated radiation therapy (IMRT) and brachytherapy, and supports the processor-less environment of the modern hospital. 2

Some of the technical benefits are: - Sensitive to doses ranging from 1cGy to 800cGy. - Develops in real time. There is no post-exposure treatment. Eliminates processing discrepancies. - Density changes stabilize rapidly after exposure. - Energy-independent dose response from kev to MeV. Eliminates concerns caused by scattered radiation. Near tissue-equivalent. - Uniformity better than 1.5%. - High spatial resolution. - Can be handled in room light. Eliminates the need for a darkroom. - Water resistant. Usable in water phantoms. - Will withstand temperatures up to 70ºC. Some of the economic benefits are: - Large size. - Eliminates the need for a processor. - Eliminates chemical wastes. - Convenient to handle and easy to cut. Film can be marked with marker pen and erased if necessary. Size and shape the film to your needs. - Competitively priced with conventional films. Significant savings. 3

CONFIGURATION AND STRUCTURE OF GAFCHROMIC EBT GAFCHROMIC EBT is made by laminating two active layers bonded together. The outer surface is polyester that makes a robust product and allows water emersion. OPTIMIZING THE SENSITOMETRIC RESPONSE OF GAFCHROMIC EBT DOSIMETRY FILM Since the absorbance spectra of GAFCHROMIC EBT peaks at 636nm, the sensitivity is maximized by measurement with red light. Transmission densitometers that are commonly used to measure visual density with conventional films are suitable for use with EBT film. Better results can be obtained from the red color channel with a color densitometer. However, the best results can be obtained by using a narrow band pass filter with central wavelength at about 636nm and 10nm bandwidth while making measurements. Response of GAFCHROMIC EBT to Co 60 Exposure Batch # 34098-2x2 2.0 Visual density Red density 636nm filter Net Visual Density 1.5 1.0 0.0 0 50 100 150 200 250 300 350 Dose (cgy) 4 Sensitometric response of GAFCHROMIC EBT in the visual and red color bands and with a 636nm filter

65000 60000 55000 50000 Dose Response of GAFCHROMIC EBT with Scanners Lot 34098-6X2IP Epson 1680 - red channel Microtek 9800XL - red channel Vidar VXR-16 Pixel Value 45000 40000 35000 30000 25000 20000 15000 0 50 100 150 200 250 300 350 400 Dose (cgy) GAFCHROMIC EBT dosimetry film can also be read with a film scanner or digitizer. As with densitometers, the response of the film will be enhanced if the spectral response of the scanner is matched to the absorbance of the film. Many high-quality scanners are designed to digitize colored films. Our preferred scanner is an Epson flatbed color scanner designed to digitize colored films up to 8 x 10 and even as large as 12 x 17 in size. These color scanners provide the best response for the EBT film from the red color channel. Black-and-white scanners usually employ a broad spectrum light source and this will usually result in a lower response with EBT film. HeNe laser scanners (Lumisys, Molecular Dynamics) provide the highest response with EBT film because the laser has a wavelength of about 633nm, very close to peak absorbance. However, the coherent light of the laser scanners can produce artifacts caused by the interaction of polarized light with the film. These artifacts can be minimized, if not eliminated, through the use of a diffuser in the beam path. 5

ENERGY INDEPENDENCE OF GAFCHROMIC EBT DOSIMETRY FILM GAFCHROMIC EBT radiochromic film has been designed to measure absorbed dose from high-energy radiation used in IMRT. The response to photons has been found to be energy-independent in the MeV range and measurements at lower energies show that the response changes by only a few percent, even down to 30keV 0.60 Energy Independence of GAFCHROMIC EBT Lot 34098-2x2, X-Rite 310T densitometer 0.50 Net Visual Density 0.40 0.30 0.20 0.10 30kVp, 2mm AI 100kVp, 2mm AI 150kVp, 2mm AI Cobalt 60 Energy Independence of GAFCHROMIC EBT Dosimetry Film 0.00 0 50 100 150 200 250 300 350 Dose (cgy) The response of GAFCHROMIC EBT dosimetry film is dependent upon factors specific to the facility such as the energy spectrum of the radiation source, the characteristics of the densitometer, film scanner or other means of measurement and the elapsed time between exposure and measurement etc. Therefore, the user should determine the dose-density response under the conditions pertaining to the user s facility and measurement protocol. Since the absolute response of GAFCHROMIC EBT dosimetry film may vary from lot to lot, the user should re-measure response when changing to a new lot number. DOSE FRACTIONATION The results in the table below indicate that the response of EBT film exposed to a single fraction is indistinguishable from the response of the film given fractionated exposure and establishes EBT film as an effective dose integrator. EXPOSURE NET VISUAL DENSITY CHANGE (average of 9 measurements) 5Gy in a single fraction 0.681 + 0.015 5Gy in 1Gy fractions at 30min. intervals 0.677 + 0.009 Response of GAFCHROMIC EBT Dosimetry Film to Fractionated Exposure 6

POST-EXPOSURE DENSITY GROWTH GAFCHROMIC EBT film develops in real time. When calibrating and analyzing films, the time interval between exposing the films and scanning them should be consistent for all films. STORAGE AND HANDLING GAFCHROMIC EBT film is designed to be handled in interior room light but it is recommended that the film be kept in the dark when not in use. Exposure to sunlight should be avoided. The film may be stored at room temperature (20º-25ºC), but the best practice is to store the film at refrigerator temperature. The shelf-life of the film is two years when stored at room ambient temperature. It can tolerate brief exposures (e.g. <1min.) to temperatures up to 70ºC, or more prolonged exposure (e.g., <1 day) at temperatures of 50ºC. However, it is recommended that the film be handled, exposed and measured at room ambient temperature (20º-25ºC). FILM SIZE GAFCHROMIC EBT - 8 x 10 GAFCHROMIC EBT-1417-14 x 17 7

ALSO AVAILABLE IMRT QA system consisting of: 1) QD + Quickstart package (includes 4 EBT boxes, scanner and 1 day hands on training.) Note: (QD + Quickstart Deluxe package with larger scan format is also available.) 2) FilmQA - IMRT plan verification software. For QA and commissioning we recommend the use of GAFCHROMIC RTQA film. This film comes in three sizes. 1) GAFCHROMIC RTQA -1010 and GAFCHROMIC RTQA -1010P both are 10 x10 and is recommended for light-field alignment, precision star-shots, autoradiography, etc. 2) GAFCHROMIC RTQA -111 which is 1.25 x11 and is recommended for verifying brachytherapy source positioning. 3) GAFCHROMIC RTQA -1417 wich is 14 x17 in dimension designed for larger field size. RTQA -111 Brachytherapy source positioning RTQA -1010 Light-field alignment test RTQA-1010P Pre-scaled RTQA -1417 Larger light-field alignment test The information contained in this brochure and the various products described are intended for use only by persons having technical skill and at their own discretion and risk after they have performed necessary technical investigations, tests and evaluation of the products and their uses. While the information herein is believed to be reliable, we do not guarantee its accuracy and a purchaser must make its own determination of a product s suitability for purchaser s use, for the protection of the environment, and for the health and safety of its employees and the purchasers of its products. Neither ISP nor its affiliates shall be responsible for the use of this information, or of any product, methods, formulation or apparatus described in the brochure. Nothing herein waives any of ISP s or its affiliates conditions of sale, and WE MAKE NO WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY OR FITNESS OF ANY PRODUCT FOR A PARTICULAR USE OR PURPOSE. We also make no warranty against infringement of any patent by reason of purchaser s use of any information, product, method or apparatus described in this brochure. In the USA, for customer service or to place an order, CALL TOLL FREE (877) 591-7884 or Product Manager, Tel: 973-628-3531, Fax: 973-628-3016 Technical Hotline: 866-218-0594 Outside the USA contact distributors as referenced in the website www.gafchromic.com Or Write: INTERNATIONAL SPECIALTY PRODUCTS Advanced Materials Group 1361 Alps Road, Wayne, NJ 07470 Product Code: ADVM0002 07/2006