arxiv: v1 [physics.ins-det] 9 Apr 2016

Similar documents
AC Bias Characterization of Low Noise Bolometers for SAFARI Using an Open-Loop Frequency Domain SQUID-based Multiplexer Operating Between 1 and 5 MHz

arxiv: v1 [astro-ph.im] 9 Apr 2016

The SPICA-SAFARI TES Bolometer Readout: Developments Towards a Flight System

Going towards the read-out of a 160 pixel FDM system for SAFARI 76 pixels connected

arxiv: v1 [astro-ph.im] 2 Apr 2016

Detection Beyond 100µm Photon detectors no longer work ("shallow", i.e. low excitation energy, impurities only go out to equivalent of

The superconducting microcalorimeters array for the X IFU instrument on board of Athena Luciano Gottardi

Implementation of frequency domain multiplexing in imaging arrays of microcalorimeters

High dynamic range SQUID readout for frequencydomain

Measurement of SQUID noise levels for SuperCDMS SNOLAB detectors

Quantum Sensors Programme at Cambridge

Two SQUID amplifiers intended to alleviate the summing node inductance problem in multiplexed arrays of Transition Edge Sensors

A 200 h two-stage dc SQUID amplifier for resonant gravitational wave detectors

PROCEEDINGS OF SPIE. Development of TiAu TES x-ray calorimeters for the X-IFU on ATHENA space observatory

arxiv: v1 [astro-ph.im] 23 Dec 2015

arxiv: v1 [physics.ins-det] 19 Sep

This document is downloaded from the Digital Open Access Repository of VTT. P.O. box 1000 FI VTT Finland VTT

EXAM Amplifiers and Instrumentation (EE1C31)

Voltage Biased Superconducting Quantum Interference Device Bootstrap Circuit

Demonstration of Multiplexed Operation of Hot-Electron Detectors Using MSQUIDs

arxiv: v1 [astro-ph.im] 7 Oct 2011

Two-stage SQUID systems and transducers development for MiniGRAIL

ExperimentswithaunSQUIDbasedintegrated magnetometer.

Advances in Far-Infrared Detector Technology. Jonas Zmuidzinas Caltech/JPL

Quantum Limited SQUID Amplifiers for Cavity Experiments

Calibration Scheme for Large Kinetic Inductance Detector Arrays Based on Readout Frequency Response

Measurement and noise performance of nano-superconducting-quantuminterference devices fabricated by focused ion beam

First tests of prototype SCUBA-2 array

Ian JasperAgulo 1,LeonidKuzmin 1,MichaelFominsky 1,2 and Michael Tarasov 1,2

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Background. Chapter Introduction to bolometers

Homework Assignment 05

SQUID Basics. Dietmar Drung Physikalisch-Technische Bundesanstalt (PTB) Berlin, Germany

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR (AUTONOMOUS) Siddharth Nagar, Narayanavanam Road QUESTION BANK

Two Level System Noise (TLS) and RF Readouts. Christopher McKenney. 4 th Microresonator Workshop 29 th July, 2011

Semiconductor Detector Systems

Josephson Circuits I. JJ RCSJ Model as Circuit Element

Chapter 2. The Fundamentals of Electronics: A Review

EVALUATION KIT AVAILABLE 10MHz to 1050MHz Integrated RF Oscillator with Buffered Outputs. Typical Operating Circuit. 10nH 1000pF MAX2620 BIAS SUPPLY

on-chip imaging spectrograph based on superconducting resonators

Transition Edge Sensors for Long Duration Balloon experiments

Design of a Temperature-Compensated Crystal Oscillator Using the New Digital Trimming Method

Netherlands c VTT, Tietotie 3, FIN Espoo, Finland ABSTRACT

photodiodes Description PerkinElmer Optoelectronics offers a broad array of Silicon and InGaAs PIN and APDs.

Pulse Tube Interference in Cryogenic Sensor Resonant Circuits

Antenna-coupled bolometer arrays for measurement of the Cosmic Microwave Background polarization

rf SQUID Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

The Athena X-ray Integral Field Unit (X-IFU)

EUA2011A. Low EMI, Ultra-Low Distortion, 2.5-W Mono Filterless Class-D Audio Power Amplifier DESCRIPTION FEATURES APPLICATIONS

Signal Integrity Design of TSV-Based 3D IC

Homework Assignment 03

CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS

OBSOLETE. Parameter AD9621 AD9622 AD9623 AD9624 Units

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

Ac-dc transfer standard shunts for frequencies up to 1 MHz. U. Pogliano, C.G. Bosco, M. Lanzillotti, D Serazio

SQUID linearization by current-sampling feedback

Figure Responsivity (A/W) Figure E E-09.

Introduction to SQUIDs and their applications. ESAS Summer School Jari Penttilä Aivon Oy, Espoo, Finland

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A new capacitive read-out for EXPLORER and NAUTILUS

T = 4.2 K T = 300 K Drain Current (A) Drain-Source Voltage (V) Drain-Source Voltage (V)

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

Ultraviolet selective thin film sensor TW30DY NEW: Read important application notes on page 4 ff.

Impedance Matching Techniques for Mixers and Detectors. Application Note 963

GaAs MMIC Non-Linear Transmission Line. Description Package Green Status

INVENTION DISCLOSURE- ELECTRONICS SUBJECT MATTER IMPEDANCE MATCHING ANTENNA-INTEGRATED HIGH-EFFICIENCY ENERGY HARVESTING CIRCUIT

10MHz to 1050MHz Integrated RF Oscillator with Buffered Outputs

ECE 145A/218A, Lab Project #1b: Transistor Measurement.

A magnetic current sensor with SQUID readout

Schottky Barrier Diode Video Detectors. Application Note 923

FUTURE INSTRUMENTATION FOR JCMT II

Increased bandwidth of NbN phonon cooled hot electron bolometer mixers

Application Note 5525

Superconducting Transition Edge Sensor Bolometer Arrays for Submillimeter Astronomy

Application Note 5012

EE12: Laboratory Project (Part-2) AM Transmitter

Planar Transmission Line Technologies

Where detectors are used in science & technology

Millikelvin measurement platform for SQUIDs and cryogenic sensors

OPTIMIZATION OF THE HOT-ELECTRON BOLOMETER AND A CASCADE QUASIPARTICLE AMPLIFIER FOR SPACE ASTRONOMY

Methodology for MMIC Layout Design

NOISE INTERNAL NOISE. Thermal Noise

Coils Loop sensors / radiating loops / Helmholtz coils

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

Figure Figure E E-09. Dark Current (A) 1.

The first uncooled (no thermal) MWIR FPA monolithically integrated with a Si-CMOS ROIC: a 80x80 VPD PbSe FPA

Nano-structured superconducting single-photon detector

Terahertz Spectroscopy by Josephson Oscillator and Cold-Electron Bolometer

EE301 ELECTRONIC CIRCUITS CHAPTER 2 : OSCILLATORS. Lecturer : Engr. Muhammad Muizz Bin Mohd Nawawi

The 350 Micrometer Wavelength Superconducting Bolometer Camera for APEX

A SQUID-BASED BEAM CURRENT MONITOR FOR FAIR / CRYRING*

Application Note 5011

The practicalities of measuring fast switching currents in power electronics using Rogowski probes

LABORATORY #3 QUARTZ CRYSTAL OSCILLATOR DESIGN

EUA W Mono Filterless Class-D Audio Power Amplifier DESCRIPTION FEATURES APPLICATIONS. Typical Application Circuit

Penn Array Receiver Penn Array Receiver CDR Document 6: Detector Design Documents Table of Contents

Advanced Topics in EMC Design. Issue 1: The ground plane to split or not to split?

Transcription:

Journal of Low Temperature Physics manuscript No. (will be inserted by the editor) arxiv:1604.02593v1 [physics.ins-det] 9 Apr 2016 L. Gottardi 1 M. Bruijn 1 J.-R. Gao 1, 2 R. den Hartog 1 R. Hijmering 1 H. Hoevers 1 P. Khosropanah 1 P. de Korte 1 J. van der Kuur 1 M. Lindeman 1 M. Ridder 1 AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz. XX.XX.2007 Keywords FDM, infra-red detector, SQUID, bolometer, TES, LC resonator Abstract SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infra-red spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1fW) and low noise (NEP 10 19 W/ Hz) in the TES bolometers. We conclude the paper by comparing the performance of a 4 10 19 W/ Hz TES bolometer measured under DC and AC bias. PACS numbers: 1 Introduction In this paper we describe a Frequency Domain Multiplexer meant for laboratory tests and designed to increase the experimental throughput in the characterization of TES bolometer array under AC bias. To simultaneously measure a large number of pixels a baseband feedback scheme 1 is required. However, to perform a single pixel characterization, each AC channel can be read-out sequentially in time. In 1:SRON National Institute for Space Research, Sorbonnelaan 2, 3584 CA Utrecht, The Netherlands 2: Kavli Institute of NanoScience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft, The Netherlands

2 this way the SQUID amplifier dynamic range is less critical and the instrument and its electronics can be greatly simplified. We took into account the following requirements while designing the multiplexer. It should allow the read-out out of tenths of pixels biased at AC voltage in the frequency range from 1 to 5 MHz. Several pixels on the array should be biased at DC voltage to allow direct comparison with the AC biased ones under identical experimental conditions. It should have easy-to-use read-out electronics. The multiplexers will be used both with ultra-low noise equivalent power (NEP) TES bolometers and with high energy resolving power x-ray microcalorimeters. The former require very low background power levels, which is achieved by means of light blocking filters in the signal loom feedthrought and a light-tight assembly. Special care has been taken to design the magnetic shielding and to improve the uniformity of the applied magnetic field across the array. In the second part of the paper we compare the performance of a 4 10 19 W/ Hz TES bolometer measured under DC and AC bias at a frequency of 1.3 MHz. In the AC bias case the bolometer is measured with a multiplexer based on discrete LC resonators and other circuit components used in our standard DC bias set-up. 2 Overview of the Open-Loop Frequency Domain Multiplexer The mechanical assembly of the Open Loop Frequency Domain Multiplexer (OL- FDM) consists of a low magnetic impurity copper bracket fitted into a Nb can. The matching of the Nb can with the bracket lid is not vacuum-tight and was designed such that it forms a labyrinth, which is filled with carbon loaded epoxy on the copper lid side. In this configuration the Nb can provides both the required magnetic and stray light shielding. A photograph and a CAD image of the OL- FDM set up is shown in Fig. 1. The electrical connections from the cold stage of Nb shield Helmholtz coil Labyrinth SQUID chip LC filters SQUID cavity TES array DC bias shunt chip Fig. 1 (Color online) Photograph and CAD models of the Open Loop Frequency Multiplexer prototype.

3 the cooler to the SQUID and TES bias circuit elements are achieved by means of superconducting looms fed through a narrow 10 mm long channel filled with carbon loaded epoxy. The circuit PC board is designed to host 2 DC and 18 AC bias channels. The latter is achieved by using the lithografic high-q LC resonators arrays developed at SRON 2. The nominal inductance of the coil used in each filter is L = 400nH, while the capacitances C are designed such that the frequencies f 0 = 1 2π are spread at a constant interval in the range from 1 to 5 MHz. LC The SQUID amplifier chip is placed in a radiation shielding cavity whose inner side is coated with a 2 mm thick radiation absorber made from carbon loaded epoxy with mixed SiC grains of size from 100µm to 1 mm 3,4. This precaution was taken to minimize possible loading of the bolometers due to Josephson radiation, typically in the range of 4-8 GHz, emitted by the SQUID junctions. The electrical connection from the SQUID chip to the LC filters is done by means of Nb strip lines on a 20 mm long interconnection chip. These lines act as a low-pass filter with a calculated roll-off around 500 MHz. The perpendicular magnetic field of the TES array is controlled by means of a superconducting Helmholtz coil, which generates an uniform field over the whole pixels array. 3 Performance of the linearized SQUID amplifier A crucial component of the multiplexer described above is the SQUID amplifier. We use a low noise two-stage PTB SQUID current sensor with on chip linearization, low input inductance (L<3nH) and low power dissipation (P<20nW) 5. The SQUID with on chip linearization 6 has a larger dynamic range with respect to the standard voltage sampled SQUID and guarantees a linear amplification of the AC biased bolometers signal. We operate the SQUID in open loop. The output signal is amplified by a 20 MHz bandwidth, low input voltage noise, commercial electronics (Magnicon B.V). To test the performance of the SQUID amplifer un- Spectral Density [pa/rt(hz)] 100 10 T=25 mk 1 2 2.5 3 3.5 4 Frequency[ MHz] Fig. 2 Squid current noise with 6 coupled high-q lithographic resonators. The Q-factor of the resonators ranges from 10000 to 20000. der loaded condition we coupled 6 high parallel LC lithographic resonators to its

4 input coil. At temperature T = 25mK we measured a SQUID input current noise of 4pA/ Hz (with 1/M in = 19.6µA/Φ 0 ) over the whole interesting frequency range from 1 to 5 MHz (Fig.2). All the six resonators had Q factors larger than 10 4. The SQUID operates in a linear regime for input current lower than 12µA. 4 Characterization of a low noise bolometer at 1.3 MHz in a pilot set-up The experiment described in the following section was carried on in a pilot set-up, described below, which is different from the one previously presented. The detector used in the experiment is a low G TES bolometers with a transition temperature of T C = 78.5mK, a normal state resistance of R N = 101mΩ and a calculated NEP of 2 10 19 W/ Hz. The sensor was previously characterized under DC bias and showed a power plateau of 3.7fW and a dark NEP of 4.2 10 19 W/ Hz 7. We tested the bolometer under AC bias at a frequency of 1.3 MHz in a three pixels FDM configuration, where two similar pixels were connected to the other LC resonators tuned at 2.3 and 4.2 MHz respectively. The latter pixels were not biased. The TES array carrying the three pixels is mounted into the light-tight box used in the DC bias experiment 7 and the connections to the resonators were done by means of relatively long twisted pairs. The three LC resonators consist of hybrid filters made of lithographic Nbfilm coils and commercial high-q NP0 SMD capacitors with C 1 = 22nF, C 2 = 4.4nF, C 1 = 2.2nF respectively. For the read-out of the TES current we use a NIST SQUID arrays consisting of a series of 100 dc-squid with input-feedback coil turns ratio of 3:1, and input inductance L in = 70nH. The input current noise is 3pA/ Hz at T < 1K. The SQUID amplifier is operated in open loop mode using commercial Magnicon electronics. The resonant frequency of the circuit is defined by the capacitors C and the total inductance L tot = L in + L+L stray. From the measured resonant frequency and the filter capacitance value reported above we get L tot = 0.64 µh. In Fig.3 we show the current-to-voltage and the power-to-voltage characteristics of the TES bolometer under test. We observe a power plateau at 7 fw at a bath temperature T bath = 30mK and when applying a magnetic field in order to cancel any residual fields perpendicular to the TES. A lower power plateau of 3.7 fw was observed with the same pixel in the measurements performed at DC bias voltage under identical condition, but in a different cooler 9. The AC bias configuration performs even better than the DC bias case in terms of power loading into the detector probably due to a better EMI filtering of the input bias lines. We further characterized the detector under AC bias by measuring the noise and the complex impedance as a function of the TES resistance. A simple two body model 8 is used to fit the impedance data and to derive the parameters, like β, loop gain L o = P o α/gt and time constant τ o = C/G, needed to estimate the detector responsivity. A distributed model would provide a more accurate estimation of those parameters 9. In Fig.4 we plot the TES current noise and the dark NEP for several TES resistances. At bias points high in the transition (R/R N > 60%) an NEP = (5.2±0.6) 10 19 W/ Hz is observed. The uncertainty in the NEP estimation is due to calibration errors. We observed a deterioration of the dark NEP at low TES resistances

5 1.4 AC-bias, B=-1766uA 40 AC-bias, B=-1766uA 1.2 35 1 30 I TES [µa] 0.8 0.6 P TES [fw] 25 20 15 0.4 10 0.2 5 0-0.02 0 0.02 0.04 0.06 0.08 0.1 0.12 V TES [µv] a) b) 0 0 0.01 0.02 0.03 0.04 0.05 0.06 V TES [µv] Fig. 3 Current-to-voltage a. and the power-to-voltage b. characteristics of the TES bolometer measured at an AC bias frequency of 1.3 MHz. Spectral Density [pa/hz 1/2 ] 10 3 10 2 R o /R n =0.69 R o /R n =0.65 R o /R n =0.58 R o /R n =0.44 R o /R n =0.34 R o /R n =0.22 R o /R n =0.15 NEP [W/Hz 1/2 ] 10-17 10-18 R o /R n =0.69 R o /R n =0.65 R o /R n =0.58 R o /R n =0.44 R o /R n =0.34 R o /R n =0.22 R o /R n =0.15 10 1 10-19 10 100 1000 10000 10 100 1000 10000 a) b) frequency[hz] frequency [Hz] Fig. 4 TES current noise a. and dark NEP b. at different TES resistances for the bolometer measured at an AC bias frequency of 1.3 MHz. due to excess noise at low frequency. The detector noise can be modeled using the parameter obtained from the impedance data. We can fully explain the measured noise at any bias point in the transition assuming a voltage noise S V 2pV/ Hz in series with the TES. The current noise generated by the voltage source has the same signature of a thermal noise from the shunt resistance used in the DC bias case. This is clearly seen in Fig.5, where the different noise contributions, including the shunt-like noise, are overplotted to the measured noise spectrum. From the quality factor Q of the resonance measured with the TES superconducting we infer a total resistance of the read-out circuit of r = 1 ω O CQ = 14.9± 0.3mΩ, where ω o = 2π 1.33MHz, C = 22nF and Q=346±6. Such a small resistance should be at a thermodynamic temperature of about 4 K to generate the voltage noise level needed to explain the measured TES current noise. The excess noise observed is likely to be due to thermal noise leaking from the channel 2 of the FDM system, whose resonator was not functioning properly and had a poor quality factor. 5 Conclusion We are developing a Frequency Domain Multiplexer to increase the experimental throughput in the characterization of TES bolometer array under AC bias.

6 Spectral Density [pa/rt(hz)] 10-10 10-11 R o /R N = 0.33 measured Total noise Phonon noise Johnson noise shunt-like noise SQUID noise 10-12 10 100 1000 10000 frequency[hz] Fig. 5 (Color on line) Measured and modelled current noise for the TES bolometer at a resistance R/R N = 0.33. The multiplexer is based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators and is designed to work in the frequency range from 1 to 5 MHz, We describe the details of the experimental set-up required to achieve low power loading (< 1fW) and low noise (NEP 10 19 W/ Hz) in the TES bolometers. The first results are expected soon. In a pilot experiment performed with a multiplexer obtaind by adapting our standard DC bias set-up, we measured a dark NEP = (5.2±0.6) 10 19 W/ Hz using a low noise TES bolometer previously characterized under DC bias. We observed a deterioration of the dark NEP for low TES resistances due to excess noise at low frequency. The excess noise is consistent with a voltage noise source in series with the TES as large as S V 2pV/ Hz likely to be due to thermal noise leaking from another channel of the FDM system. Acknowledgements We thank Manuela Popescu and Martijn Schoemans for their precious technical help. References 1. R. den Hartog et al. These Proceedings. 2. M.Bruijn et al. These Proceedings. 3. M.C. Diez, T.O. Klaassen et al., UV, Opt. and IR Space Telescopes and Instr. 4013, 129-139, (2000). 4. P Hargrave, Nuclear Instruments and Methods In Physics Research Section A: 444, 427-431 (2000). 5. D. Drung et al. IEEE Transactions on Applied Superconductivity, 19, 3, 2009. 6. M. Kiviranta, Supercond. Sci. Tech, v. 21, n. 4, pp. 045009-045012, 2008. 7. R. Hijmering et al. These Proceedings. 8. Y. Takei, et al,journal of Low temperature Physics,151, 161166, 2008 9. P. Khosropanah et al. These Proceedings.