CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

Similar documents
PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

ROTATIONAL STABILITY MAKES THE DIFFERENCE

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

I N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

Long-term quality of vision is what every patient expects

Improving Lifestyle Vision. with Small Aperture Optics

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

Preloaded. PreciSAL. EZ Toric

Unique Aberration-Free IOL: A Vision that Patients

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

HYDROPHILIC ACRYLIC ADVANCED POLYMER

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

Evolution of Diffractive Multifocal Intraocular Lenses

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

COMPARISON OF THE MEDICONTUR 860FAB

Intraocular lens Difficulties

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

PreciSAL Preloaded Lens System

Clinical Evaluation 3-month Follow-up Report

THE ASPHERIC PRELOADED INJECTION

Dr. Magda Rau Eye Clinic Cham, Germany

Wide Diopter Range and Different Haptic Platforms

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Multifocal and Accommodative

Advances in the design and

Intraocular Lens Materials & Manufacturing Technology 2013

FEA of Prosthetic Lens Insertion During Cataract Surgery

EDOF-IOLs: Are they all the same?

Multifocal IOL Basics

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

(12) United States Patent (10) Patent No.: US 7,156,854 B2

Treatment of Presbyopia during Crystalline Lens Surgery A Review

UIN: IOL Date of Prep: April Avansee Preload1P. Technical Slide Kit April 2017

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

The complete choice in refractive lens solutions

Medicontur IOLs: Materials & Design Main Characteristics

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress!

Clinical Evaluation 3-month Follow-up Report

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

FOR PRECISE ASTIGMATISM CORRECTION.

The Miracle of Pi in Eye. Rajesh Khanna, MD

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/16

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

OCULUS Pentacam AXL Always an Axial Length Ahead

József Győry. Veszprem, Hungary

Raise your expectations. Deliver theirs.

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Accommodating IOL s History and Clinical Management

Small lens. Great freedom.

OptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Technicians & Nurses Program

Choosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS

IOL Review and FLACS Update

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Ocular Scatter. Rayleigh Scattering

12 10) Patent No.: US 8.663,235 B2. Tassignon (45) Date of Patent: Mar. 4, 2014 (54) BAG-IN-THE-LENS INTRAOCULAR LENS FOREIGN PATENT DOCUMENTS

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Clinical Update for Presbyopic Lens Options

Contents. Corneal Markers, Scleral Depressors

(12) Patent Application Publication (10) Pub. No.: US 2016/ A1

NIMO TR1504 CONTACT US. Lambda-X s.a. Av. Robert Schuman 102 B-1400 NIVELLES Belgium

New CONNECTING VISIONS

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Advanced Technology IOLs

Evolution of the Cataract Patient

Part 1: Ophthalmic optics Contact lenses. Vocabulary, classification system and recommendations for labelling specifications


ASPIRA PUBLICATION LIST

Sulcoflex Pseudophakic Supplementary IOLs

(12) United States Patent (10) Patent No.: US 6,334,862 B1

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

Introducing a lens that can take your scleral fitting to a higher plane.

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

ISO INTERNATIONAL STANDARD. Ophthalmic optics Contact lenses Part 3: Measurement methods

The Dysphotopsia Mystery. John J. Bussa, M.D.

IODA s.r.l. Semi finished VEGA2 the best solution for wrap frames.

Semi-Finished Lens Processing & Edging Guide and Technical Data

Transcription:

Bi-Flex IOL RANGE

CONTENTS HYDROPHILIC IOLs Bi-Flex PIL-MA hydrophilic preloaded... 1 677P / PY 677PT / PTY 677PMY 677PMTY Bi-Flex HL... 2 677AB / ABY Bi-Flex T... 3 677TA / TB 677TAY / TBY Bi-Flex M... 4 677MY Bi-Flex MT... 5 677MTY HYDROPHOBIC IOLs Bi-Flex POB-MA hydrophobic preloaded... 6 877PA / PAY Bi-Flex HB... 7 877FAB / FABY CONSTANTS FOR MEDICONTUR IOLS... 8

Single use injection system for Bi-Flex preloaded monofocal, toric and diffractive progressive hydrophilic IOLs 1 st CLICK LOADING Insert the injector to the wet container $ 2 nd CLICK CLOSING Fold up the cartridge nozzle M 3 rd CLICK READY Push the red stopper forward to the end position and fill visco ' INJECTION Push the plunger slowly to the end position ' Lens types Diameters Angulation Material Single-piece aspheric IOLs, clear and yellow Æ Monofocal Æ Toric Æ Diffractive Progressive Æ Toric Diffractive Progressive (Patent pending) 6.0 mm (optic) 13.0 mm (overall) 0 asymmetrical design Copolymer of hydrophobic and hydrophilic monomers 25% water content with UV Absorber / + blue light filter (390 470 nm) 677P/677PY Powers available -10.0 D " -1.0 D (increment: 1.0 D) 0.0 D " +30.0 D (increment: 0.5 D) +31.0 D " +35.0 D (increment: 1.0 D) 677PT/677PTY Powers available -10.0 D " -1.0 D (increment: 1.0 D) 0.0 D " +30.0 D (increment: 0.5 D) +31.0 D " +35.0 D (increment: 1.0 D) Cylinders available 1.00 D, 1.50 D, 2.25 D, 3.00 D, 3.75 D, 4.50 D 677PMY Powers available 0.0 D " +35.0 D (increment: 0.5 D) Addition +3.5 D Incision size 2.2 mm PCO protection 360 Special Square Edge A-Constant 118.9 () 677PMTY Powers available +10.0 D " +30.0 D (increment: 0.5 D) Cylinders available 1.00 D, 1.50 D, 2.00 D, 2.50 D, 3.00 D, 3.50 D, 4.00 D, 4.50 D Addition +3.5 D LA-IMCPILMAENG 09 201608 1 Switzerland / Geneva

677AB 677ABY Hydrophilic IOL Technical specification Type Single-piece Aspheric Hydrophilic Intraocular Lens for implantation into the capsular bag Optic PCO protection Estimated incision size Aspheric 360 Special Square Edge (patented) from 1.8 to 2.2 mm Powers available* -10.0 D " +9.0 D (increment: 1.0 D) +10.0 D " +30.0 D (increment: 0.5 D) +31.0 D " +45.0 D (increment: 1.0 D) A-Constant** Sterilization 118.1 () Steam Material 677AB Copolymer of Hydrophilic and Hydrophobic Acrylic 25% water content with UV Absorber 677ABY + blue light filter Refractive index 1.46 ABBE Nr. 58 Geometry Optic design Biconvex Overall lenght 13.0 mm Optic diameter 6.0 mm Haptic thickness 0.40 mm 6 mm 13 mm Haptic angulation 0 asymmetrical design with posterior vaulting Storage Temperature +15 +35 C 0.4 mm Humidity 15% 50% Shelf life 5 years (from sterilization) * Other powers upon request ** It is recommended that surgeons personalize the constants they use. Please find more information about IOL constants on ULIB. (http://www.ocusoft.de/ulib/c1.htm) EA-IMCBHLEN 06 201607 2 Geneva / Switzerland

677TA / TB 677TAY / TBY Hydrophilic Toric IOL Technical specification Type Single-piece Aspheric Hydrophilic Toric Intraocular Lens for implantation into the capsular bag Optic 677TA / TAY 677TB / TBY PCO protection Estimated incision size Toric Aspheric Bitoric Aspheric 360 Special Square Edge (patented) from 2.2 to 2.4 mm Powers available * -10.0 D " -1.0 D (increment: 1.0 D) 0.0 D " +30.0 D (increment: 0.5 D) +31.0 D " +35.0 D (increment: 1.0 D) Cylinders available 677TA / TAY 1.0; 1.5 D " 9.0 D (increment: 0.75 D); 10.0 D 677TB / TBY +11.0 D " +24.0 D (increment: 1.0 D) A-constant** Sterilization 118.9 () Steam Material 677TA / TB Copolymer of Hydrophilic and Hydrophobic Acrylic, 25 % water content with UV absorber 677TAY / TBY + blue light filter Refractive index 1.46 ABBE number 58 Geometry Optic design Overall length Biconvex 13.0 mm Optic diameter 6.0 mm 6 mm 13mm Haptic thickness Haptic angulation 0.40 mm 0 asymmetrical design with posterior vaulting Storage Temperature +15 +35 C 0.4 mm Humidity 15% 50% Shelf life 5 years (from sterilization) * Other powers upon request ** It is recommended that surgeons personalize the constants they use. Please find more information about IOL constants on ULIB. (http://www.ocusoft.de/ulib/c1.htm) EA-IMCBTHLEN 04 201608 3 Export Office Geneva/Switzerland

677MY Hydrophilic Progressive Diffractive IOL Technical specification Type Single-piece Aspheric Hydrophilic Progressive Diffractive Intraocular Lens for implantation into the capsular bag Optic PCO protection Estimated incision size Diffractive Aspheric 360 Special Square Edge (patented) from 1.8 to 2.2 mm Powers available* 0.0 D " +35.0 D (increment: 0.5 D) Addition A-constant** Sterilization +3.5 D 118.9 () Steam Material 677MY Copolymer of Hydrophilic and Hydrophobic Acrylic, 25% water content with UV absorber + blue light filter Refractive index 1.46 ABBE number 58 Geometry Optic design Diffractive zone Biconvex Anterior surface (diameter 3.0 mm) 0,4 mm Overall length Optic diameter 13.0 mm 6.0 mm Ø 3 mm Haptic thickness 0.40 mm Ø 13 mm Ø 6 mm Diffractive zone Diffractive side Haptic angulation Storage 0 asymmetrical design with posterior vaulting Temperature +15 +35 C Humidity 15% 50% Shelf life 5 years (from sterilization) * Other powers upon request ** It is recommended that surgeons personalize the constants they use. Please find more information about IOL constants on ULIB. (http://www.ocusoft.de/ulib/c1.htm) EA-IMCBMHLEN 04 201608 4 Geneva/Switzerland

677MTY Hydrophilic Progressive Diffractive Toric IOL Technical specification Type Single-piece Aspheric Hydrophilic Progressive Diffractive Toric Intraocular Lens for implantation into the capsular bag Optic PCO protection Estimated incision size Progressive Diffractive / Toric Aspheric 360 Special Square Edge (patented) from 2.2 to 2.4 mm Powers available* +10.0 D " +30.0 D (increment: 0.5 D) +31.0 D " +35.0 D (increment: 1.0 D) Cylinders available 1.0 D " 4.5 D (increment: 0.5 D) 5.25 D " 6.0 D (increment: 0.75 D) Addition A-constant** Sterilization +3.5 D 118.9 () Steam Material 677MTY Copolymer of Hydrophilic and Hydrophobic Acrylic, 25% water content with UV absorber + blue light filter Refractive index 1.46 ABBE number 58 Geometry Optic design Diffractive zone Overall length Optic diameter Haptic thickness Haptic angulation Biconvex Anterior surface (diameter 3.0 mm) 13.0 mm 6.0 mm 0.40 mm 0 asymmetrical design with posterior vaulting Storage Temperature +15 +35 C Humidity 15% 50% Shelf life 5 years (from sterilization) * Other powers upon request ** It is recommended that surgeons personalize the constants they use. Please find more information about IOL constants on ULIB. (http://www.ocusoft.de/ulib/c1.htm) EA-IMCBMTHLEN 04 201606 5 Geneva/Switzerland

877PA Æ 877PAY Hydrophobic intraocular lens preloaded in a single use injector* Fill visco in the hole until the optic of the lens is covered (preferably HPMC) 1 st STEP 2 nd STEP Rotate the transparent ring to close the cartridge 3 rd STEP 4 th STEP Pull out the red stopper Remove the ring-adapter from the injector INJECTION Push the plunger slowly to the end position Type Single-piece Aspheric Hydrophobic Acrylic IOL Material Hydrophobic Acrylic with UV absorber / + optional blue light filter Diameters Angulation 6.0 mm (optic) / 13.0 mm (overall) 0 asymmetrical design Power range -10.0D " +9.0D (increment: 1.0 D) +10.0D " +30.0D (increment: 0.5 D) +31.0D " +35.0D (increment: 1.0 D) A-Constant Incision size 118.9 () 2.2 mm * Patent pending LA IMCPOBMAENG 04 201608 6 Switzerland / Geneva

877FAB 877FABY Hydrophobic IOL Technical specification Type Single-piece Aspheric Hydrophobic Intraocular Lens for implantation into the capsular bag Optic PCO protection Estimated incision size Refractive Aspheric 360 Special Square Edge (patented) 2.4 mm Powers available* 0.0 D " +9.0 D (increment: 1.0 D) +10.0 D " +30.0 D (increment: 0.5 D) +31.0 D " +35.0 D (increment: 1.0 D) A-constant** Sterilization 118.9 () Ethylene-oxide Material 877FAB 877FABY Hydrophobic Acrylic with UV absorber + blue light filter Refractive index 1.47 ABBE number 58 Geometry Optic design Biconvex Overall length Optic diameter 13.0 mm 6.0 mm Haptic thickness 0.35 mm 6 mm 13 mm Haptic angulation 0 asymmetrical design with posterior vaulting Storage Temperature +15 +35 C 0,35 mm Humidity 15% 50% Shelf life 5 years (from sterilization) * Other powers upon request ** It is recommended that surgeons personalize the constants they use. Please find more information about IOL constants on ULIB. (http://www.ocusoft.de/ulib/c1.htm) EA-IMCBHBEN 03 201606 7 Geneva / Switzerland

CONSTANTS FOR BI-FLEX IOLs FOR OPTICAL OR IMMERSION ULTRASOUND MEASUREMENTS BI-FLEX IOLs Bi-Flex 677AB/677ABY Bi-Flex PIL-MA 677P/677PY a0 = 0.325 a1 = 0.255 a2 = 0.141 pacd = 5.01 sf = 1.25 A = 118.1 Bi-Flex T 677TA/TB - 677TAY/TBY Bi-Flex PIL-MA 677PT/677PTY a2 = 1.000 Bi-Flex M 677MY Bi-Flex PIL-MA 677PMY Bi-Flex MT 677MTY Bi-Flex PIL-MA 677PMTY Bi-Flex HB 877FAB/877FABY Bi-Flex POB-MA 877PA/877PAY a0 = 1.320 pacd = 5.46 sf = 1.70 A = 118.9 a0 = 1.320 pacd = 5.46 sf = 1.70 A = 118.9 EA-IMCAKONSTEN 01 201606 It is recommended that surgeons personalize the constants they use based on their techniques, equipment and post-operative results. IOL constants were calculated using previous experiences with formula and relations between constants. (Source:(http://www.ocusoft.de/ulib/c1.htm). For further assistance please contact our Scientific Group at scientific@medicontur.com. Geneva/Switzerland 8

NOTES

Vision of expertise An independent European company, ever growing and evolving since 27 years. Consistent high quality with more than 4 million intraocular implants manufactured and implanted. The most diverse portfolio of Intraocular Lenses, both hydrophilic and hydrophobic, all premium categories, state of the art preloaded systems. A team of more than 250 dedicated professionals constantly pushing the limits of quality. Facilities located near Geneva (Switzerland), Limas (France), Brno (Czech Republic) and near Budapest (). Distribution in more than 60 countries with a growing share worldwide. Switzerland