A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

Similar documents
Craftsman Style Columns. Ease of installation Interior or exterior use Quick Ship from inventory Made-to-Order services CAD drawings / shop drawings

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

PVC Column Wraps - Semi-Assembled INSTALLATION INSTRUCTIONS

Endura-Classic Craftsman Information

SECTION SIMULATED WOOD TRIM. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

A. Provide all finish carpentry needed for a complete and proper installation.

Column Wraps. Column Wraps are non-structural. Pressure-treated posts not included.

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

SECTION BULLET- RESISTANT DOORS

Ash Brook Golf Course Scotch Plains, New Jersey

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Exterior Moulding & Trim Special Order Items. royalbuildingproducts.com Royal Building Products

Product Guide Specification For Nonrated & 20-Minute Rated Doors

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

SECTION CARPENTRY

SECTION ARCHITECTURAL WOODWORK

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

Make every component count.

Inteplast Trim Free Foam

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION MANUFACTURED CASEWORK

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

TURNCRAFT ARCHITECTURAL COLUMN INSTALLATION INSTRUCTIONS

B. Related Requirements: 1. Section "Interior Painting" for priming and backpriming of interior finish carpentry.

4. Metal roof jacks at penetrations and attachments

Student Services & Classroom Addition

SECTION INTERIOR FINISH CARPENTRY

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

INSTALLATION GUIDE. 5" Balustrade System

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

SECTION ARCHITECTURAL WOOD CASEWORK

Balustrades & Columns

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

Design and Construction Standards SECTION ATHLETIC LOCKERS

SECTION WOOD DOORS

GENERAL INSTALLATION GUIDE: WARRANTY: PRODUCT INFORMATION T F

VYTEC ARCHITECTURAL SPECIFICATIONS

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

SECTION INTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS

A. Boards or Strips: Lumber of less than 2 inches nominal size in least dimension.

1.04 QUALITY ASSURANCE

PREHUNG DOOR SYSTEM INSTALLATION INSTRUCTIONS: FIBRECOMP COMBINATION UNITS

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SilvaTrim SilvaSoffit

SECTION HOLLOW METAL DOORS AND FRAMES

Product Guide Specification

Canadian Product Spec Guide

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

ETCHED PLAQUES by Matthews International

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SECTION WOOD ACCORDION FOLDING DOORS

ENDUREED VIVA SERIES Specifications

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

A. Submit manufacturer's technical data and installation for each type of sign required.

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

DIVISION 6 WOOD, PLASTICS AND COMPOSITES

SECTION ARCHITECTURAL WOODWORK. B. Related Sections: 1. Section Paints and Coatings: Field applied painted finishes.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION FINISH CARPENTRY

Solid Surface Countertops

Endura-Stone Installation Instructions

Vinyl Windows Manufactured by VPI Quality Windows

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

Slate Shingle Specifications

EXTERIOR PAINTING

SECTION INTERIOR FINISH CARPENTRY. A. Lumber grading agencies, and the abbreviations used to reference them, include the following:

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

1. Division 6 Section "Rough Carpentry" for furring, blocking, and other carpentry work that is not exposed to view.

SECTION PRE-MANUFACTURED CABINETS

SECTION METAL FABRICATIONS

SECTION HOLLOW METAL DOORS AND FRAMES

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

SECTION ASPHALT SHINGLES

Guide Specifications Section

Section 808. FENCING

SECTION ROUGH CARPENTRY

B. Related Sections: The following Sections contain requirements that relate to this Section:

Shapes Siding. Perfection Shingles. Chalk Line

Aluminum Clad Wood Window Field Mulling and Stacking Instructions

SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

SECTION PAINTING

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

QWALL 5.2 (2 Back Panels)

SECTION SHEET METAL FLASHING AND TRIM

Vista Lakes New Architectural Guideline for Fences Adopted by the Vista Lakes Board of Directors September 10, 2009 (Rev. November 11, 2009)

HOW TO INSTALL ELITE PANELED WAINSCOTING Using X-Rails with Either Raised, Flat or Beaded Panels

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

SECTION SIGNAGE

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

Installation Instructions

SECTION PLASTIC FABRICATIONS PART I GENERAL 1.01 SECTION INCLUDES

Transcription:

WorthingtonWrap PVC Columns Architectural Specifications 1.1 SECTION INCLUDES A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable. B. Decorative Capitals and Bases: To fit over shaft through center of capital and base. C. Materials for column installation. 1.2 RELATED SECTIONS A. Section 06100 - Rough Carpentry: Wood framing. B. Section 06441 - Architectural Wood Columns. 1.3 SUBMITTALS A. Submit under provisions of Section 01300. B. Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. A. Shop Drawings: For custom products, show dimensions, configuration, and anchorages. B. Selection Samples: Color photographs representing manufacturer's full range of available materials and styles. 1.4 DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturer's unopened packaging until ready for installation. B. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. 1.5 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. 1.6 WARRANTY A. At project closeout, provide to Owner or Owners Representative a copy of the manufacturer s limited warranty outlining its terms and conditions. 1. Duration: Twenty Five (25) years. B. Free from defects in material and workmanship for " Twenty Five (25) years " of ownership. Installation must be per manufacturer's guidelines. " Twenty Five (25) years " means as long

as purchaser of column owns the structure to which column is attached for up to Twenty Five (25) years from the date of purchase". C. Free from defects in material and workmanship for " Twenty Five (25) years " of ownership. Installation must be per manufacturer's guidelines. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Worthington Millwork, LLC. 2405 Ruth Hentz Ave. Panama City, FL 32405 800-872-1608/F.850-640-0488 Email: sales@worthingtonmillwork.com Web: www.worthingtonmillwork.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600 2.2 DECORATIVE COLUMNS A. WorthingtonWrap Column Plain - Standard Sizes: 1. Height: 6 feet (1829 mm). 2. Height: 8 feet (2438 mm). 3. Height: 9 feet (2743 mm). 4. Height: 10 feet (3048 mm). 5. Height: 12 feet (3658 mm). 6. Size: 6 inches (152 mm) square. 7. Size: 8 inches (203 mm) square. 8. Size: 10 inches (254 mm) square. 9. Size: 12 inches (305 mm) square. 10. Panel Thickness: 3/8 inch (10mm). 11. Panel Thickness: 5/8 inch (16mm). 12. Assembly Type: Assembled. 13. Assembly Type: L -Assembly. B. WorthingtonWrap Column With Decorative Machining Standard Sizes: 1. Height: 6 feet (1829 mm). 2. Height: 8 feet (2438 mm). 3. Height: 9 feet (2743 mm). 4. Height: 10 feet (3048 mm). 5. Height: 12 feet (3658 mm). 6. Size: 6 inches (152 mm) square. 7. Size: 8 inches (203 mm) square. 8. Size: 10 inches (254 mm) square. 9. Size: 12 inches (305 mm) square. 10. Panel Thickness: 5/8 inch (16mm). 11. Decorative Machining: Fluted. a. Flutes per side: 3. b. Flutes per side: 5. c. Flutes per side: 7. d. Flutes per side: 8. 12. Decorative Machining: Recessed Panel.

13. Decorative Machining: Raised Panel. 14. Assembly Type: Assembled. 15. Assembly Type: L -Assembly. C. WorthingtonWrap Column Craftsman Standard Sizes: 1. Height: 54 inches (1371 mm). 2. Height: 60 inches (1524 mm). 3. Height: 66 inches (1676 mm). 4. Height: 72 inches (1829 mm). 5. Height: 96 inches (2438 mm). 6. Size: 12 inches (305 mm) by 8 inches (203 mm). 7. Size: 16 inches (406 mm) by 10 inches (254 mm). 8. Size: 20 inches (508 mm) by 15 inches (381 mm). 9. Panel Thickness: 5/8 inch (16mm). 10. Decorative Machining: Recessed Panel. 11. Decorative Machining: Raised Panel. 12. Assembly Type: Assembled. 13. Assembly Type: L -Assembly. D. WorthingtonWrap Column - Pedestal/Newel Standard Sizes: 1. Height: 40 inches (1016mm). 2. Height: 46 inches (1168mm). 3. Size: 16 inches (406 mm) square. 4. Size: 20 inches (508 mm) square. 5. Size: 24 inches (610 mm) square. 6. Panel Thickness: 5/8 inch (16mm). 7. Decorative Machining: Recessed Panel. 8. Decorative Machining: Raised Panel. 9. Assembly Type: Assembled. 10. Assembly Type: L -Assembly. E. WorthingtonWrap Column Plain - Custom Sizes: 3. Size: Minimum: 5 inches (127mm) square. 4. Size: Maximum: 48 inches (1219 mm) square. 5. Panel Thickness: 3/8 inch (10mm). 6. Panel Thickness: 1/2 inch (13mm) 7. Panel Thickness: 5/8 inch (16mm). 8. Panel Thickness: 3/4 inch (19mm) 9. Panel Thickness: 1 inch (25mm) 10. Configuration Plan Type: Square 11. Configuration Plan Type: Rectangle 12. Configuration Plan Type: Pilaster Flat 13. Configuration Plan Type: Pilaster with Returns 14. Configuration Plan Type: Outside corner (adjacent sides) Flat 15. Configuration Plan Type: Outside corner (adjacent sides) with Returns 16. Configuration Plan Type: U-Shape with Returns 17. Assembly Type: Assembled. 18. Assembly Type: L -Assembly. F. WorthingtonWrap Column With Decorative Machining Custom Sizes: 3. Size: Minimum: 5 inches (127mm) square. 4. Size: Maximum: 48 inches (1219 mm) square.

5. Panel Thickness: 3/8 inch (10mm). 6. Panel Thickness: 1/2 inch (13mm) 7. Panel Thickness: 5/8 inch (16mm). 8. Panel Thickness: 3/4 inch (19mm) 9. Panel Thickness: 1 inch (25mm) 10. Configuration Plan Type: Square 11. Configuration Plan Type: Rectangle 12. Configuration Plan Type: Pilaster Flat 13. Configuration Plan Type: Pilaster with Returns 14. Configuration Plan Type: Outside corner (adjacent sides) Flat 15. Configuration Plan Type: Outside corner (adjacent sides) with Returns 16. Configuration Plan Type: U-Shape with Returns 17. Decorative Machining: Fluted. a. Flutes per side: Variable. 18. Decorative Machining: Recessed Panel. 19. Decorative Machining: Raised Panel. 20. Assembly Type: Assembled. 21. Assembly Type: L -Assembly. G. WorthingtonWrap Column Craftsman Custom Sizes: 3. Size: Minimum Bottom of Shaft - 5 inches (127 mm) 4. Size: Maximum Bottom of Shaft 48 inches (1219 mm) 5. Size: Minimum Top of Shaft - 5 inches (127 mm) 6. Size: Maximum Top of Shaft 48 inches (1219 mm) 7. Panel Thickness: 3/8 inch (10mm). 8. Panel Thickness: 1/2 inch (13mm) 9. Panel Thickness: 5/8 inch (16mm). 10. Panel Thickness: 3/4 inch (19mm) 11. Panel Thickness: 1 inch (25mm) 12. Configuration Plan Type: Square 13. Configuration Plan Type: Rectangle 14. Configuration Plan Type: Pilaster Flat 15. Configuration Plan Type: Pilaster with Returns 16. Configuration Plan Type: Outside corner (adjacent sides) Flat 17. Configuration Plan Type: Outside corner (adjacent sides) with Returns 18. Configuration Plan Type: U-Shape with Returns 19. Decorative Machining: Fluted. 20. Decorative Machining: Recessed Panel. 21. Decorative Machining: Raised Panel. 22. Assembly Type: Assembled. 23. Assembly Type: L -Assembly. H. WorthingtonWrap Column - Pedestal/Newel Standard Sizes: 3. Size: Minimum: 5 inches (127mm) square. 4. Size: Maximum: 48 inches (1219 mm) square. 5. Panel Thickness: 3/8 inch (10mm). 6. Panel Thickness: 1/2 inch (13mm) 7. Panel Thickness: 5/8 inch (16mm). 8. Panel Thickness: 3/4 inch (19mm) 9. Panel Thickness: 1 inch (25mm) 10. Configuration Plan Type: Square 11. Configuration Plan Type: Rectangle

12. Configuration Plan Type: Pilaster Flat 13. Configuration Plan Type: Pilaster with Returns 14. Configuration Plan Type: Outside corner (adjacent sides) Flat 15. Configuration Plan Type: Outside corner (adjacent sides) with Returns 16. Configuration Plan Type: U-Shape with Returns 17. Decorative Machining: Fluted. a. Flutes per side: Variable. 18. Decorative Machining: Recessed Panel. 19. Decorative Machining: Raised Panel. 20. Assembly Type: Assembled. 21. Assembly Type: L -Assembly. I. Capitals and Bases: 1. Capital: Ogee Cap. 2. Capital: Style 1 3. Capital: Style 2 4. Capital: Style 3 5. Capital: Style 4 6. Capital: Style 5 7. Capital: Style 6 8. Capital: Style 7 9. Capital: Style 8 Tuscan a. 6 inches (152 mm) square b. 8 inches (203 mm) square. c. 10 inches (254 mm) square. d. 12 inches (305 mm) square. e. 14 inches (356 mm) square. f. 16 inches (406 mm) square. 10. Capital: Style 9 11. Capital: Style 10 12. Capital: Style 11 13. Bases: Tuscan. 14. Bases: Ogee. 15. Bases: Style 1 16. Bases: Style 2 17. Bases: Style 3 18. Bases: Style 4 19. Bases: Style 5 20. Bases: Style 6 21. Bases: Style 7 22. Bases: Style 8 Tuscan a. 6 inches (152 mm) square b. 8 inches (203 mm) square. c. 10 inches (254 mm) square. d. 12 inches (305 mm) square. e. 14 inches (356 mm) square. f. 16 inches (406 mm) square. 23. Bases: Style 9 24. Bases: Style 10 25. Bases: Style 11 2.3 ACCESSORY MATERIALS A. Adhesive Caulk: Acrylic Urethane water based exterior grade. 1. Use along entire length of open miter joints during installation. 2. Use to caulk cap and base prior to shaft of column.

3. Use to cover holes of nails or screws in molding for square columns. B. Mounting Accessories: 1. Bottom PVC internal squaring/mounting blocks. 2. Top PVC internal squaring/mounting blocks. 3. Anchor Fasteners: Concrete anchors. 4. Anchor Fasteners: Hollow wall anchors. 5. Cap and Base Fasteners: Screws. 6. Cap and Base Fasteners: Nails. 7. Molding Fasteners: Screws. 8. Molding Fasteners: Finishing nails. 9. Column Shaft assembly fasteners: Galvanized finishing nails. 10. Column Shaft assembly fasteners: Stainless Steel finishing nails. 11. Column Shaft assembly fasteners: 1/4 narrow crown galvanized finishing staples. 12. Column Shaft assembly fasteners: 1/4 narrow crown stainless steel finishing staples. 2.4 FINISH A. Primer: 1. Acrylic Based Primer: One light, even coat of top quality exterior acrylic primer. 2. Oil Based Primer: One light, even coat of top quality exterior oil-based primer. B. Finish Coat: 1. Latex Based Finish: Three light, even coats of high quality exterior 100% acrylic or acrylic latex paint. PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until substrates have been properly prepared. B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. C. Check opening height before ordering columns. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation with alcohol or ammonia based cleaning solution. B. Do not use paint thinner, turpentine, or mineral spirits to prepare surface because of the residue that will remain. This residue will prevent proper paint adhesion. C. Do not use MEK, lacquer thinner, acetone, or any other MEK based solvent to prepare surface. MEK based products will cause PVC to dissolve. D. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. E. If attaching handrails or corner iron to column, install solid pressure treated wooden blocking between the inside face of the column and the structural post to receive handrail mounting screws. 3.3 INSTALLATION

A. Install in accordance with manufacturer's instructions. B. Plumb and level column shaft. If column cannot be centered around structural post, modify internal squaring/mounting blocks with jig saw to allow column location as needed. If modification of furnished internal squaring/mounting blocks still does not permit desired positioning, installer may field fabricate blocking out of pressure treated lumber. 3.4 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION