FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control

Similar documents
FiberLight D2 Portfolio UV-Vis Light Source for high measurement consistency

Ultraviolet Visible Infrared Instrumentation

Table 8 Overview light sources

Light Sources. Tip. Light Sources

Microscope-Spectrometer

Cobolt Optogenetics Laser Solution

AvaLight-DHc Full-range Compact Light Source

XENON FLASH LAMP MODULES

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Spark Spectral Sensor Offers Advantages

JETI Specbos Instruments

Cobolt Optogenetics Laser Solutions

5 W XENON FLASH LAMP MODULES

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

FX-4400 High-Output Xenon Flashlamps

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Cobolt Optogenetics Laser Solutions

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Compact High Intensity Light Source

Tunable KiloArc. Tunable Broadband Light Source.

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

Laser Systems. !!!! iflex-iris

iflex-iris Laser Systems Product features include:

Oriel Flood Exposure Sources

Optical In-line Control of Web Coating Processes

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Description of options, upgrades and accessories for the laser beam stabilization system Compact

PGS Family Plane Grating Spectrometer from ZEISS

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS

Research Grade Xenon Arc Lamp Sources LH-Series 75 W - 300W

Integrated Diode Laser System DioPower

Hollow Cathode Lamps

Genesis CX STM-Series

LINEARPYROMETER LP4. Technical Documentation KE November TN

Small Area Lens Based Solar Simulators SF series, SLB series

Acculase Green PWM. Direct Drive Green Laser Diode Module

Power Measurment. Hand-held Design Brings Peak Performance to the Field. Introduction. Features

CHAPTER 7. Components of Optical Instruments

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

Think of LASER as a tool

LIGHT FOR LIFE SCIENCES SUSTAINABLE LIGHTING BRIGHT.CLEAN.GREEN. LIGHT ENGINES

SCCH 4: 211: 2015 SCCH

Lab Junior Educational UV-VIS Spectrometer

Features. Applications. Optional Features

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

Company synopsis. MSU series

Basic Components of Spectroscopic. Instrumentation

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

OBIS CellX. The Universal Light Engine FEATURES

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Fully Portable Spectrophotometer for Transmission Measurement

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

FIBER EVO. Miniaturized laser module complete with controller and USB power supply all within an incredibly small package

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

iflex-iris Fiber coupled laser systems Product features include:

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

Wavelength Meter Sensitive and compact wavemeter with a large spectral range for high speed measurements of pulsed and continuous lasers.

Scalable high-power and high-brightness fiber coupled diode laser devices

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Where brightness and quality are essential for you Specialty light sources for medical and industrial applications

idonus UV-LED exposure system for photolithography

High-Power 8.0 W 9xx nm Fiber-Coupled Diode Laser 6397-L3 Series

COMPACT Diode Laser System (Water-Cooled)

FAQs. Not directly. The pe-100 Control Pod does have a BNC connector to allow for TTL triggering.

Premier & Acculase Range Modular Modulatable Lasers

Spectroradiometer specbos 1201

Optical Fibers for Improved Low Loss Coupling of Optical Components

THEIMER - lamps. The optimal type for every application. Ga - Fe doped: Multi spectrum type TH...2 Ga - Pb doped: Dual spectrum type THS...

Optional AR coating and wedge windows are available

LRS-0532-PF SERIES INFORMATION SHEET

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

Fiber Coupled Single Bar Diode Laser (CW)

The extremely compact laser head is approximately 480 mm long and can

Omicron-Laserage Laserprodukte GmbH. Product catalogue Light sources

LED Lighting Flux and Color Measurement System (LFC)

FULLY REFLECTIVE SOLAR SIMULATORS SS0.5K / SS1.0K / SS1.6K / SS2.5K

We bring quality to light. MAS 40 Mini-Array Spectrometer

L4 and L4i 915/940 nm Fiber- Coupled Lasers

ZM18 Series DATASHEET SENSORPARTNERS.COM. Sensor Partners BVBA Z.1 Researchpark 310 B-1731, Zellik Belgium

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Recorders OUR MOST COMPACT CHART RECORDER! Input Number Chart Special Description Type of Pens Size Options Page

Pulsed Laser Power Measurement Systems

HITEK POWER EG353 SERIES HIGH-STABILITY 35 KV HIGH VOLTAGE POWER SUPPLIES FOR PRECISION SEM E-BEAM APPLICATIONS

R. Lebert 1, K. Bergmann 2, O. Rosier 3, W. Neff 2, R. Poprawe 2

Operating Manual. Model 721N. Visible Spectrophotometer

Infrared Basics and Technology

specification display & lighting hera spectrometer

Varilite Datasheet. Thread Mountable Laser Diode Module

SPECTRAL IRRADIANCE DATA

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Photonic Crystal Fiber Interfacing. In partnership with

Solea. Supercontinuum Laser. Applications

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

RIEGL s VUX-1HA High Accuracy kinematic LiDAR sensor is a very high

Flash-lamp Pumped Q-switched

Lasers for Life Sciences

Transcription:

FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control

FiberLight Miniature UV-Vis Light Source FiberLight DTM 6/10 FiberLight is a compact UV-Vis light source designed for mobile spectroscopy applications and all types of handheld devices that require a low power consumption UV-Vis light source. FiberLight has a continuous spectrum covering the whole range from vacuum UV to near Infrared. The FiberLight System is a complete UV-Vis light source with a shine-through design deuterium lamp, a 0.25 Watt tungsten lamp, shutter, optical system and SMA 905 connector. All elements are mounted on a printed circuit board driven by an external 12 Vdc/600 ma power supply. Both lamps and the shutter can be separately controlled by a TTL signal. FiberLight is powered from an external supply; this makes it an ideal light source for applications with limited space in the instrument, portable instruments or batteryoperated equipment. Its small dimensions and ease of operation open up new possibilities for instrument designers. The features of this light source open the way for new solutions in small spectroscopy equipment and UV optics: Compact size Low power consumption (6 Watt) Low heat dissipation Instant lamp ignition Cyclic operation Extended service life of up to 3 years Shutter function External control Easy coupling to optical fibers, measuring cells and capillaries Applications Laboratory: UV-Vis Spectroscopy Environment: water quality monitoring, waste water analysis, marine chemistry, biological measurements Process control Stand-alone light source Calibration 4

HighPower FiberLight DTM 10/50 Spectral Distribution of FiberLight The spectral emission covers the entire range from 200 nm to 1,100 nm; optional extended range from 185 nm to 1,100 nm. HighPower FiberLight A 10W High Power FiberLight version is now available, offering double UV light output and similar compact size. Higher power means shorter integration time for faster response and lower detection limits; while still small size suitable for portable operation. Comparison of Spectral Distribution Rel. Intensity (%) 100 80 60 40 20 High Power FiberLight Standard FiberLight 0 200 300 400 500 600 700 800 900 1000 Wavelength (nm) Select your FiberLight System Do you need a fiber connection? NO Do you need < 200nm wavelengths? NO YES DTM6/11 80003030 DTM6/11S 80048581 YES What size fiber do you need? 200 µm Do you need < 200nm wavelengths? NO YES DTM6/50 45006281 DTM6/50S 80001017 400 µm Do you need < 200nm wavelengths? NO Do you need a smaller NO Do you need higher power NO physical size? visible light? DTM6/10 80007444 YES YES YES DTM6/10S 80000755 DTM6/20 80056245 DTM6/15 80010770

FiberLight DTM 6/17 with collimated beam Lifetime and Cyclic operation The guaranteed continuous operating life of a FiberLight deuterium lamp is more than 1000 hours. As the lamp is an Electrodeless Discharge Lamp (EDL) with high frequency excitation, it can be switched ON and OFF on demand and can be operated in cycles. The cyclic lamp operation results in an extended service life of up to three years. As an EDL, the number of ignitions does not reduce lifetime. In addition, pulse-to-pulse repeatability is extremely consistent to within 0.1 %. Instant ON and Instant Stability FiberLight EDL is the only deuterium lamp that can be switched instantly ON and instantly deliver a stable light output. This feature makes it unique among UV light sources. FiberLight is therefore the ideal light source in analytical instruments for pollution monitoring, where light absorption is measured for only a few seconds and repeated after long intervals. In such monitoring, FiberLight is switched ON only for the short measurement time, while it is OFF for most of the time. Nevertheless, measurement consistency is extremely good because of its pulse-to-pulse repeatability. Application Example To measure nitrate content in waste water, FiberLight is switched ON for 2 seconds to measure the nitrate light absorption, and the measurement is repeated every 60 seconds. Measurement consistency is extremely good and under these operating conditions, lamp lifetime can be extended up to 3 years. FiberLight Lamp Life Characteristics Relative Intensity (%) 120% 100% 80% 60% 40% 20% Typical lifetime characteristics of FiberLight DTM 6/10 measured at 250 nm 0% 0 200 400 600 800 1000 1200 Operating Time (h) Cyclic Operation Cyclic operation at 230 nm / measuring time: 18 sec; off = 10 sec Light Intensity 40200 35200 30200 25200 20200 15200 10200 5200 200 0 40 80 120 160 200 240 280 320 360 20 60 100 140 180 220 260 300 340 380 Time (seconds)

Technical Specifications Parameter Standard FiberLight DTM 6/10, 6/11, 6/17, 6/20, 6/50 High Power FiberLight DTM 10/50 S Spectral distribution 200 1100 nm, optional 185 1100 nm 185 1100 mm Power consumption 6 Watt 12 Watt Power requirements 12 Vdc / 0.6 Adc 12 Vdc / 1.2 Adc Operating ambient temperature 5 35 C 5 35 C Relative humidity max. 90%, non condensing max. 90%, non condensing Dimensions (L x W x H) 157 55 37 mm 161 58 51.5 mm DTM 6/17: 105 36 35 mm, DTM 6/20: 123 36 35 mm Weight 130 g 230 g Shutter yes yes Tungsten Lamp yes yes External control lamp (D2, W-Lamp) ON/OFF independently lamp (D2, W-Lamp) ON/OFF independently shutter open/close shutter open/close green LED is lit when the 12 Vdc supply voltage is applied green LED is lit when the 12 Vdc supply voltage is applied Light exit focused or collimated beam focused Optical fiber diameter 200 µm, 400 µm, 600 µm 200 µm, 400 µm, 600 µm Optical fiber connector SMA 905 SMA 905 Numerical aperture NA D2 lamp 0.245, W-lamp 0.057 D2 lamp 0.245, W-lamp 0.057 Cooling not required forced, fan on-board Deuterium Lamp Spectral distribution 200 400 nm line free 200 400 nm line free Window material fused quartz, fused synthetic silica fused synthetic silicia Light output (radiant intensity) 5 10-8 W/sr @ 240nm 10 10-8 W/sr @ 240nm Stability 1 10-3 AU To Be Determined Drift 0,25 %/h To Be Determined Exciting frequency 250 khz 250 khz Operation voltage Approx. 1kV Approx. 1kV Life* 1000 h @ 240 nm (50 % intensity loss) 1000 h @ 240 nm (50 % intensity loss) Power consumption approx. 5 Watt approx. 10 Watt Tungsten Lamp Spectral distribution 400 1100 nm 400 1100 nm Voltage 5 Vdc 5 Vdc Current 45 madc 45 madc Typical Lifetime 2000 h 2000 h 2 optical configurations are available: Focused Beam (for connection to an optical fiber) or Collimated Beam (quasi parallel light). 6W Standard and 12W High Power version now available, with 2 light output and similar compact size. PCB layout can be designed to suit your compact instrument footprint. Please contact us to arrange your customized design, optimized for your instrument application.

Replacement lamps For FiberLight type DTM6/10 DTM 6/10S DTM 6/50 DTM 6/50S Replacement lamp type DTL 6/10 DTL 6/10S DTL 6/50 DTL 6/50S Part no. 45006253 80000756 45006266 80001018 Aperture size 1.0 mm 1.0 mm 0.5 mm 0.5 mm Window material Fused quartz Fused synthetic silica Fused quartz Fused synthetic silica Spectral distribution with optical fiber 200 1100 nm 185 1100 nm 200 1100 nm 185 1100 nm Recommended fiber 400 600 µm 400 600 µm 200 600 µm 200 600 µm We reserve the right to change the pictures and technical data of this brochure. HNG B 154 E 02/2013 Germany USA United Kingdom PR China Heraeus Noblelight GmbH Heraeus Noblelight LLC Heraeus Noblelight Analytics Ltd. Heraeus Noblelight (Shenyang) Co., Ltd. Heraeusstraße 12 14 1520C Broadmoor Blvd Nuffield Close 5F, 16th Building, No. 99 Tianzhou Rd. D-63450 Hanau Buford, GA 30518 Cambridge CB4 1SS Shanghai, 200233 Phone +49 (6181) 35 5085 Phone +1 (678) 835 5681 Phone +44 (1223) 424100 Phone +86 (21) 5445 2255 Fax +49 (6181) 35 7970 Fax +1 (678) 835 5766 Fax +44 (1223) 426338 Fax +86 (21) 5445 2410 hng-analyticallamps@heraeus.com sales.hni@heraeus.com hna-analytics@heraeus.com info.hns@heraeus.com www.heraeus-noblelight.com www.heraeus-noblelight.com www.heraeus-noblelight.com www.heraeus-noblelight.cn