*Current connection required for smooth zerocrossing switch operation

Similar documents
SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

Modular step relays 16 A

Data sheet. Function description. Benefits

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

theben 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB

Time Switches. Because we have a Responsibility

Fibaro System Modules

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Operating Instruction

DIN Rail Time & Twilight Switches

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

13 SERIES. Electronic step relays A

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Fixture Built-in Sensor Daylight Harvest Version

Instruction manual. art Installation manual

Electronic step, call/reset and monostable relays

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

PIR6WT-1Z interface - time relays

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

EY-EM 522, 523: Remote I/O module, ecolink522, 523

Power supply CP-T 48/5.0 Primary switch mode power supply

38 Series - Relay Interface Modules A

Operating Instructions

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Installation / Monitoring Technique

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

ISOMETER IRDH575. Approvals

E-STOP relays, safety gate monitors

SINEAX U 553 Transducer for AC Voltage

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

W DATA SHEET Current Transformer 40 x 10, A

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

MINI MCR-SL-UI-I-LP-NC

38 Series - Relay interface modules A. Features /

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-T 48/20.0 Primary switch mode power supply

Level Limit Switch nivotester FTL 325 P

Power supply CP-T 24/10.0 Primary switch mode power supply

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

Power supply CP-T 24/40.0 Primary switch mode power supply

Theta 20A / 20V. Technical Data Sheet. Special Features

Power supply CP-T 24/20.0 Primary switch mode power supply

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

QUINT-PS AC/24DC/40

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

13 Series - Electronic step relays A. Features SERIES

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Universal Radio Cord Dimmer Order No.: Function

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Switching and control professionals electronic switching relays, control relays and coupling relays

luxcontrol lighting control system DSI sensors smartdim SM lp Control module for combination with ambient light sensor, switch or presence sensor

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

QUINT-PS-24DC/24DC/10

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DATA SHEET Selectable AC transducer TAS-311DG

Sentry Digital Timers

E-STOP relays, safety gate monitors

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Electronic Thermostat TE-1 Version according to EN

luxcontrol lighting control system Sensors smartswitch 5DP 14f Automatic switching based on presence and light level

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Electronic impulse switches the silent revolution

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Smart Street Light System using Embedded System

13 Series - Electronic step/monostable & call/reset relays 8-16 A. Features

SEPARATOR P20G TYPE USER S MANUAL

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

Selection tables Command devices E 250 latching relays

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

luxcontrol lighting control system DALI sensors basicdim RCL DBC Control module for combination with ambient light sensor, switch and presence sensor

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

PHOENIX CONTACT - 09/2009

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

ORDERING CODE Z-WAVE FREQUENCY COUNTRY/REGION

QUINT-PS/ 3AC/24DC/10

Transcription:

2 2 310 317 02 LUNA LUNA 109 109 0 100, 109 0 200 110 0 100, 110 0 200 GB Assembly and operating instructions Twilight Switch Test 2 2000 LUNA 109 I:2-35 II : 35-200 III : 200-1000 min max IV:1-5klx V: 5-50klx min D GB F I E P NL PL 0,5mm - 2,5mm 2 2300 W 16A-10AX 250V~ 8mm 1 2 3 220-240V~ 50-60Hz 30 T 0,5mm - 2,5mm 2 3600 W 16A-16AX 250V~ 8mm 1 2 3 220-240V~ 50-60Hz 30 T LUNA 109 * *Current connection required for smooth zerocrossing switch operation (see connection diagram) only ).

Contents Service address/hotline 2 Basic advice 3 Connection/assembly 4 Connection/assembly of a light sensor 5 Display and control elements 6 Initial start-up 7 Technical data 8 Serviceadresse Theben AG Hohenbergstr. 32 72401 Haigerloch DEUTSCHLAND Fon +49 (0) 74 74/6 92-0 Fax +49 (0) 74 74/6 92-150 Hotline Fon +49 (0) 74 74/6 92-369 Fax +49 (0) 74 74/6 92-207 hotline@theben.de Adresses, telefon numbers etc. www.theben.de 2

Basic advice GB WARNUNG Danger of death through electric shock or fire! Assembly may only be carried out by qualified electricians! The device corresponds to EN 60669-2-1; it is designed for installation on DIN top hat rails (in accordance with EN 50022) Designated use The twilight switch is used for controlling the light facilities of streets, external stairways shop windows, entrances etc. For use only in closed, dry rooms (device); the sensor is intended for ourdoor installation Disposal Dispose of equipment in an environmentally-friendly manner 3

Connection/assembly Connect cable Strip cable back to 8 mm (max. 9). Insert cable in open terminal at 45 angle (2 cables per terminal position possible). To open spring screwless terminal, press upwards with screwdriver. 4 WARNUNG Danger of death through electric shock! Assembly may only be carried out by qualified electricians! Disconnect power supply! Ensure it is not turned on again! Check power is off! Earth and short-out! Cover or shield any adjacent live parts. Spring screwless terminal Spring screwless terminal opener Test tap Cable 45

Connection/Assembly of a light sensor GB Note the length of the connecting cable: max. 100 m (2 x 1,5 mm 2 ), max. 50 m (2 x 0,75 mm 2 ) Avoid running the sensor line parallel to conductors. Surface-mounted light sensor: 0,5 2,5 mm 2, strip the wire to 10 mm (max. 11 mm). max. 8 mm O 15,2 mm 0,75 mm 2 < 50 m 2 1,5 mm < 100 m ca. 38 mm 907 0 011 907 0 416 Surface-mounted light sensor Built-in light sensor 5

Display and control elements LUNA 109 ❷ ❶ 2 Test 2000 LUNA 109 ❸ ❹ ❶ Potentiometer for setting the brightness: 2-2000 lx ❷ Key Test for checking the installation (independent of brightness) ❸ Immediate display of the switched condition by means of a red LED ❹ Display of channel condition by means of a green LED (relay) 6 ❷ ❶ I:2-35 II : 35-200 III : 200-1000 min max IV:1-5klx V: 5-50klx min ❸ ❹ ❺ ❶ Potentiometer for setting the brightness treshold ❷ Potentiometer for setting the brightness range: and PERM ON/PERM OFF (test) I: 2 35 lx II: 35 200 lx III: 200 1.000 lx IV: 1.000 5.000 lx V: 5.000 50.000 lx ❸+❹ as described above ❺ Potentiometer for switch ON/switch Off delay (0 to 20 min.)

I:2-35 Initial start-up The twilight switch with external light sensor is used for controlling the light facilities of streets, stairways, entrances etc. Set the desired range I-V on the potentiometer ❷ using a screw driver. Set the desired treshold ❶. The red LED will light up, if the set value underruns the ambient brightness. ❷ ❶ II : 35-200 III : 200-1000 min max IV:1-5klx V: 5-50klx min ❸ ❹ ❺ GB Recommendation: set a delay ❺ of at least 1 min, to avoid switching errors owing to lightening flashes, car headlights etc. Typical brightness values daylight (bright) 80.000 lx office rooms 500 lx corridors and stairs 100-150 lx street lighting 15 lx full moon ca. 0,3 lx 7

Technical Data LUNA 109 Nominal voltage: 220 240 V, ~, +10 %/ 15 % 220 240 V, ~, +10 %/ 15 % Frequency: 50 60 Hz 50 60 Hz On/off switch delay: 1 min. 0 20 min. Power consumption: ca. 3 VA ca. 3 VA Contact material: AgSnO 2 AgSnO 2 Contact: floating phase-independent (zero-crossover switching) Gap: <3 mm (μ) <3 mm (μ) Switching capacity max.: 16 A, 250 V~, cos ϕ = 1 16 A, 250 V~, cos ϕ = 1 Switching capacity min.: 10 ma/230 V AC 10 ma/230 V AC 100 ma/12 V AC/DC 100 ma/12 V AC/DC Switching capacity fluorescent lamps: 10 AX 16 AX Incandescent lamp load: 2300 W 3600 W Halogen lamp load: 2300 W 3600 W Fluorescent lamp loads capacitive ballast uncorrected: 2300 VA 3600 VA series corrected: 2300 VA 3600 VA parallel corrected: 400 VA (42μF) 1200 VA (130μF) dual circuit: 2300 VA 3600 VA Fluorescent lamps electronic ballast: 300 VA 1200 VA Mercury and sodium vapour lamps: series corrected: 400 VA (42μF) 1200 VA (130μF) Compact fluorescent lamps electronic ballast: 9x 7W, 7x11 W, 34x7 W, 27x11 W, 24x15 W, 7x15 W, 7x20 W, 7x23 W 22x23 W Permissible ambient temperature: 30 C... +55 C (device) 30 C... +55 C (device) 40 C... +70 C (sensor) 40 C... +70 C (sensor) Protection class: Protection rating: 8 II (light sensors III) for designated installation IP 20, IP 55 (surface-mounted light sensor), IP 65 (built-in light sensor) in accordance with EN 60529