Aurora Group of Companies

Similar documents
contraa Hit the Mark! High-Resolution Continuum Source AAS

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

Simplicity. Reliability. Performance. ProdigyPlus

Stop Worrying About Interferences With These ICP-OES Solutions

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

Spotlight 150 and 200 FT-IR Microscopy Systems

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Finer Points of ICP-OES Setup and Operation

ICP-MS. plasma 3. Multi-Collector ICP-MS.

Spectrum 400. FT-IR and FT-NIR Spectrometer. There is only one answer.

Ultraviolet Visible Infrared Instrumentation

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Hollow Cathode Lamps

Expert. Elemental Scientific VPD-ICPMS. Fully Automated Auto Scanning System ICP ICPMS AA

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System --

Fully Automated Auto Scanning System VPD-ICPMS Expert

Content Spectrophotometers

SpectraMax i3x Multi-Mode Detection Platform. Explore a wealth of applications in one future-ready system

CONTENTS Product Accessory Software V /02 V-5100/UV /04 UV-5100B 05/06

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Column Chromatography System

Oriel Flood Exposure Sources

Who is GBC Scientific Equipment?

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

PRODUCT BROCHURE. Affordable Lab Technology

Synergy NEO HTS Multi-Mode Microplate Reader

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

T A I N S T R U M E N T S

A Laser-Based Thin-Film Growth Monitor

Directions for running IC samples on the Shimadzu TOC analyzer. (5/18/2015 DER)

PUV3402 LED multiwave photometer A new approach to online process photometry

Nicolet Almega XR. High Performance Micro and Macro Dispersive Raman Analysis Systems

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring

taccor Optional features Overview Turn-key GHz femtosecond laser

Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology

1) Solar simulator with I-V measurement setup and software

INTERPLANT STANDARD - STEEL INDUSTRY

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

FLIR K2. FLIR-DIRECT.ca

Hitachi Double Beam Spectrophotometer

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Croma Enterprise Cromtech India

Compact High Intensity Light Source

Spectro UV-VIS Double Beam Research Spectrophotometer UV-VIS Double Beam

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

StarBright XLT Optical Coatings

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Prodigy DC Arc The Ultimate Solution for Elemental Analysis of Solid Samples

Outline of Standard Protocols for Particulate Organic Carbon (POC) Analyses

Lambda X65 series. UV/Vis Simplified for your Lab. Gerlinde Wita October 2015

Background Why? What are the business drivers? Subsea, Surface or FLNG? Subsea Dehydration & The SubCool Hybrid Concept

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

TriVista. Universal Raman Solution

instruments Analytical Instruments for Science

Nicolet Evolution 500. UV-Visible Spectrophotometer

Thermo Scientific SPECTRONIC 200 Education

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Microplate Reader EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm

Speed, Quality, Versatility, and Value; Gerber introduces the new Solara ion Inkjet Printer

NOCOLOK Technical Brazing Center and Technical Service

Measurement of Temperature, Soot Diameter and Soot Volume Fraction in a Gulder Burner

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

Goyen 2000 Flue Gas Analyzer Two Sensors (O 2, CO)

Coating Thickness Measurement System

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

2014 Chromatography Supplies & Instruments Catalog

Pulsed System for Optical Discharge of Thin-film Insulators

TRITON Plus Thermal Ionization MS. Another step ahead. in TIMS. Earth and Planetary Sciences Nuclear Sciences

Spark Spectral Sensor Offers Advantages

INTERNATIONAL INTERCOMPARISON OF WAVELENGTH SCALE AND PHOTOMETRIC SCALE OF SPECTROPHOTOMETRY LABORATORIES CENAM - NRC - INMETRO - NIST.

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

UV / VIS Spectrophotometer

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission:

Diamond Analysis. Innovation with Integrity. Reliable identification and type determination by FTIR spectroscopy FTIR

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

ABB conductivity analyzer and probe package

NEPTUNE Plus Multicollector ICPMS. Another step ahead. in MC-ICP-MS. Earth and Planetary Sciences Nuclear Sciences

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Historical. McPherson 15 Mount


Pulsed Laser Power Measurement Systems

Inertial Sensors. Ellipse Series MINIATURE HIGH PERFORMANCE. Navigation, Motion & Heave Sensing IMU AHRS MRU INS VG

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Major Fabrication Steps in MOS Process Flow

Material analysis by infrared mapping: A case study using a multilayer

MPI TS300-SE 300 mm Manual Probe System with ShielDEnvironment TM For accurate and reliable DC/CV, RF and mmw measurements

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

Ultra-high speed inkjet droplet measurement and monitoring with laser diagnostics

A NEW MULTI-POINT, MULTI-PULSE THOMSON SCATTERING SYSTEM FOR THE MST RFP

CU-LASP Test Facilities! and Instrument Calibration Capabilities"

Product Range Electronic Units

Polymer Comparisons for the Storage and Trace Metal Analysis of Ultrapure Water with the Agilent 7500cs ICP-MS Application

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

BD LSRFortessa X-20. Special Order Product. Designed for limited space and boundless potential

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

Transcription:

Aurora Instruments t Ltd. Smart Solutions for Elemental Analysis

Aurora Group of Companies Over 16 years, Aurora Instruments has been dedicated to designing, manufacturing and servicing analytical instruments. Aurora Instruments Ltd. Aurora Biomed Inc. Aurora BioPharma Ltd.

Atomic Absorption Spectrometer AI 1200 W 65 X D 55 X H 37 cm

AI 1200 Configurations AI 1200 Flame AI 1200 Flame/Graphite Furnace (F/GF) AI 1200 Vapor Generation (VG)

AI 1200 Features Switchable single/double beam optics Automatic Switch between all atomizers Auto aligned & five-lamp turret Transversely heated GF tube High GF heating rate ( upto 3800K/s) On-line dilution for single standard calibration for flame system

AI 1200 Features Universal XYZ auto sampler - Best of any AA Industry leading AISPEC software Built in high-intensity intensity power supply Unmatched performance for flame and GF analysis Smallest footprint with big engine! with built in GF power supply and optics (f=300mm)

AI 1200 Flame Solid Teflon spray chamber Titanium coated burner head Inert to both acids and organics Corrosion resistant Nebulizer impact bead

Flame AAS Performance Exceptional performance: 2 ppm Cu sample is 0.4 ABS over ten 4 sec. integrations with less than 0.5% RSD

Online Dilution Use a single stock solution to create entire set of calibration standards Decrease time and increase accuracy of results Patented technology

Safety Interlocks Standard d Safety Interlocks Burner head detection Flame sensor Automatic shut off Gas pressure sensor Automated oxidant changeover

AI 1200 Graphite Furnace Heating rate of 3800 K/s Up to 30 programmable heating steps to suit any application Fast-dry technique with autosampler greatly reduces analysis times Superior drying stage temperature control Detection limits in the ppb range

Transverse Heating GF Transversely heated furnace provides spatially isothermal temperature gradient 6 pictogram Cd sample Benefits: Reduced memory effects Lower background signals High atomization efficiency

Fast Dry Technique Programming injection speed, preheating of temperatures, and cooling times Benefits: 1. Decrease Analysis time Normally, atomization step takes 1-2 minutes due to time required to dry the atomizer before sample introduced and cooling times after. Fast dry technique reduces time to seconds. 2. Increase Detection Limits Reduce splattering by slowing depositing sample onto a preheated surface thus giving improved reproducibility, sensitivity and detection limits

AI 1200 Vapor Generation (VG) VG 411 Determination of hydrideforming elements Mercury analysis Revolutionary gas-liquid separator 3 layer reaction/mixing manifold

Benefits Vapor/Hydride Generation AAS Sub-trace detection limits for Hg & hydride forming elements Quartz tube atomizer provides enhanced sensitivities and reduced interferences Controllable peristaltic pumps for reproducible measurements Limitless flexibility to optimize instrument according to application RSD of 15 ng/ml Hg sample

Background Correction The AI 1200 AAS employs two correction techniques: Smith-Hieftje / Self Reversal Deuterium Lamp Correction industry leading 1000Hz modulation frequency

Advantages of Zeeman Zeeman IF: -Structured Background Interferences are Expected (i.e. As in a high PO -3 4 Matrix). -Spectral Interferences are Expected (i.e. As in High Al Matrix). Deuterium IF: - Don t Expect Structured Background or Spectral Interferences (95+% of the Existing Applications of AA). - Want Maximum Sensitivity. - Want Maximum Dynamic Range. - Want High Performance while limiting instrument costs.

Limitation of Zeeman Correction Sensitivity loss for some elements (Al, Sb,As, Cu, Se, Te) Due to complexity of splitting of absorption profile in magnetic field Loss of dynamic range Increase in calibration curvature resulting in roll over point Cost

Universal XYZ Autosampler Compatible with ALL atomizers: F/GF/VG 3D movement in all directions Virtually UNLIMITED sample capacity Robust movement compared rotary design Adapt to ANY sample container: test tubes, cups, micro plates, etc

XYZ AUTOSAMPLER Use of Autosampler + AISPEC TM software allows: Calibration from a single standard Offers on-line dilution Perform Fast-Dry furnace techniques Programming injection speed, preheating of temperatures, t and cooling times Benefits: Increased sensitivities Reduced analysis times High precision

AISPEC TM Software Standard windows interface Template/worksheet environment Ability to customize the window view Single Run allow operator to test a method at any time Batch Run automated/manual control of multiple samples

AISPEC TM Software Wavelength scan feature to further assist method development Easy calibration of instrument No Stimulations Real-time graphics allow easy interpretation of data Export files to LIMS and other software for quality assurance and control

AISPEC TM Software Benefits Easy to use Lower learning curve Reduced training cost

Competitor Analysis Aurora AI 1200 Perkin Elmer Varian Thermo Automatic-Switch F/GF High End ($) Dual, Simultaneous Single/Double Beam No No No On-Line Dilution No SIPS System ($$) No Dual, Simultaneous Optical Modulation 1000 Hz Up to 220 Hz Up to 220 Hz Up to 220 Hz 1 Autosampler for F/GF/VG No No No Transverse Heating Graphite Tube (THGT) High End No No Background D2/SH D2/Zeeman D2/ Zeeman D2 (optional Zeeman) Built-in High Intensity Power No No No

Competitor Analysis Aurora AI 1200 GBC Analytika Jena Shimadzu Automatic-Switch F/GF No Yes, Manual Top Model Switching Platform Single/Double Beam No No No On-Line Dilution No No No Optical Modulation 1000 Hz N/A N/A Less than 220 Hz 1 Autosampler for F/GF/VG No No Yes (F/GF only) Transverse Heating Graphite High End High End Model (Nov No Tube (THGT) Model (Ultra-Z) AA 440G) Background D2/SH D2 & Zeeman D2 or Zeeman; Both (High End) only High End (Zeenit 700) Built-in High Intensity Power No No No D2/SH

In Brazil: DCtech Instrumentação Ltda - GlobalLab group www.globallab.com.br Contact: Eng. Marco J. Felix marco.felix@dctech.com.br Aurora Instruments Ltd. 1001 E. Pender St. Vancouver, BC Canada V6A 1W2 www.aurora-instr.com