COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008

Similar documents
F l a t S c r e e n A R M S I n s t a l l a t i o n

IDR assembly instructions:

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Installation Instruction

Desk/Wall-Mount Rack

Powerware Series. Eaton Rail Kit 9- and 12-Slot Cabinets Installation Guide

OFS ED-6C Instruction Sheet LIGHTGUIDE CROSS-CONNECT Comcode: LGX DISTRIBUTING FRAME INSTALLATION

Before Assembling the Storage Wall

19" EIA Wall Mount Swing Rack Installation Instructions

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

LAN Locker Adjustable Shelves

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

ESA-100 Fixed Sidelite/Non Breakout

INSTALLATION INSTRUCTIONS

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Installation Guide 40670

Unequal Flange Rack Installation Instructions

Gared Pro-S Portable Backstop

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

MPA-9000 Universal Ceiling Projector Mount Kit

TITAN2-EDGE Public Access Computer Station Dual Track

96 (Standard Length)

BOX-118 E-Z-Go TXT Utility Box Mounting Kit Installation Instructions

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

User Instructions Multiline Otter Scoreboard Caddy Assembly

O-Sullivan King 4 Poster Bed O-Sullivan Queen 4 Poster Bed Parts and Hardware List

Linear Hook- on Worksurfaces

Track Rack. * Track Racks are not lockable

INSTRUCTION BOOKLET #34. For Wallbed models: KING SIZE SIERRA WITH STORAGE HEADBOARD

SECURITY DOORS - 2', 3', 4'

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

TITAN INDUSTRIAL RACK 4-FOOT TALL / 3-SHELF

Franklin Mills Stackable Movable Lateral Instructions

08+ KAWASAKI KLR PD NERF

BOX-115 Club Car Precedent Utility Box Mounting Kit Installation Instructions

How To Measure Your Finished Opening

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

TABLE OF CONTENTS REQUIRED TOOLS

INSTRUCTION BOOKLET #C20

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Installation Instructions Hinged Roof Rack

LCD TV WALL MOUNT INSTALLATION INSTRUCTIONS. DUAL Swing Arm (RFWD-110) WARNING

40670 Transit Connect/NV200/City Express/ProMaster City Partition

31082 INSTALLATION INSTRUCTIONS

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

Medium HoneyBadger Chase Rack Installation Instructions

Assembly Instructions for model: VMPR1

**MOUNTING YOUR MONITOR

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

Hiniker Company th St. P.O. Box 3407 Mankato, MN VEHICLE INSTALLATION INSTRUCTIONS FOR: CHEV/GMC 4x4: K1500 SILVERADO/SIERRA

BIFOLD FUTON FRAME TRINITY ARM. Seat Rails and Slats x 1. *Note: Use 4pc of 100mm Bolts and 4pc of 60mm Bolts to attach the arms to the Stretchers.

INSTALLATION INSTRUCTIONS

ESA-200 Fixed Sidelite

RMD3000 DPO3000 Series Rackmount Kit

Custom Wood Frame Overlay for Glass Doors Installation Instructions

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

BOX-117 E-Z-Go RXV Utility Box Mounting Kit Installation Instructions

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

CRYSTEEL S. this manual must be included with the vehicle after completing the installation.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

INSTRUCTION BOOKLET #C21. For Wallbed models: KING SIZE

Installing the Exterior Cosmetics

BIKE FILE (301)

ROCKWELL. Two Panel Door. Half X Door. Double X Door. Z Combination Door

ROCKWELL 4-IN-1 DOOR. Two Panel Door. Half X Door. Z Combination Door. Double X Door

FOLDING POCKET DOOR SYSTEM ALT-F Installation Manual

RMD5000 Rackmount Kit Instructions

NX7 SERIES 5-1/2 HANDRAIL

PFW Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

INS T A L L A TIO N INS T R U C TIO N S HORSESHOE W/ BAR HANGER

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

ICU TRACKLESS SLIDING DOOR

INSTALLATION INSTRUCTIONS

Kai Installation Instructions

Barricade Trail Force HD Rear Bumper w/ Tire Carrier installation (07-16 Wrangler JK)

WPS crew Doors Installation instructions

ESA-300 Full Breakout

INSTALLATION LOW HEADROOM EXTENSION. 1 Cutting Vertical Track. 2 Quick Install Jamb Brackets

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

HD installation guide

INSTALLATION INSTRUCTIONS KK-K9-C12-K CHEVY IMPALA

TITAN INDUSTRIAL RACK 6-FOOT TALL / 4-SHELF

INSTALLATION INSTRUCTIONS, AND PARTS LIST

For additional assistance call

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

Installation Instructions. Oakmont Folding Doors

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

RM4000 Tektronix 4000 Series Rackmount Kit

Install Instructions. NewAge Steel Welded Tall Locker

Installation Guide Philips MP40/50/60/70 Installation Kit for Penlon Anesthesia Machine

This instruction manual is an in-depth look and explanation of how to assemble and install the Murphy Bed properly and efficiently.

19" EIA Wall Mount Swing Rack Installation Instructions

Side Mount INSTRUCTION BOOKLET #C122 BED STYLE: PARK CITY

NOTE: Top section pole (Q) is packed INSIDE bottom section pole (S)

Transcription:

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX101425 Standard Release A March 2008 A UPON RECEIPT OF YOUR Copper / Fiber Manager Rack Great care has been taken to insure that your Copper / Fiber Manager Rack arrives safely. If upon receipt any damage is noted, the carrier should be notified immediately to file a damaged freight claim. The Copper / Fiber Manager Rack is shipped unassembled**. An assembly hardware package is provided in order to assemble the unit. Refer to pages 5 to 9 for assembly instructions for the optional Copper or Fiber Vertical Cable Management Channel. COMPONENTS (Knockdown) QTY. PART DESCRIPTION 1 A RACK TOP CHANNEL 2 B FRAME CHANNEL* 2 C HORIZONTAL TROUGH** 2 D FLOOR ANGLE B D 19-IN MODEL SHOWN C * The 19-in. model frame channels are symmetrical and tapped front and rear. The 23-in. model comes with one right and left rails and tapped in the front only. ** Welded model is shipped already assembled except items C comes apart. Voir PX101463 pour la version française du guide d installation. Installation Instructions PX101425 page 1/9

ASSEMBLY HARDWARE QTY. DESCRIPTION 12 10-32 (23 ) / 12-24 (19 ) x ½ PAN HEAD SCREW W/ LOCKWASHER (for Horizontal Cable Trough) 8 3/8-16 x 1 HEX BOLT (for Bottom Frame Floor Angle) 8 3/8 LOCKWASHER (for Bottom Frame Floor Angle) 8 FLAT WASHER (for Bottom Frame Floor Angle) 2 KEP NUT ¼ in. (for Grounding Stud) 2 ¼ in. EXT TOOTH LOCKWASHER (for Grounding Stud) ORDERING NUMBER NUMBER PART MODEL TYPE COLOR AX101178 RACK KNOCKDOWN 19 BLACK AX101179 RACK WELDED 19 BLACK AX101254 * RACK KNOCKDOWN 19 GREY AX100930 RACK KNOCKDOWN 23 GREY AX100931 * RACK KNOCKDOWN 23 BLACK AX100932 VERT. CHANNEL FIBER - GREY AX100933 VERT. CHANNEL FIBER - BLACK AX101180 VERT. CHANNEL COPPER - BLACK AX101181 HORI. TROUGH FIBER / COPPER 19 BLACK AX101182 HORI. TROUGH FIBER / COPPER 19 GREY AX101182 HORI. TROUGH FIBER / COPPER 23 GREY AX101183 HORI. TROUGH FIBER / COPPER 23 BLACK ON ORDER ONLY Note: Copper / Fiber Manager Rack are supplied with (2) Horizontal Troughs Installation Instructions PX101425 page 2/9

CAUTION: The Copper / Fiber Management Rack should be anchored securely to the floor in order to minimize the potential of accidentally tipping the unit during equipment installation. The bottom frame mounting angles are provided with four 3/4 holes to permit anchoring. The following tools are required for assembling the Copper / Fiber Manager Rack: Phillips screwdriver; 9/16 open or adjustable wrench; 5/16 nut driver, open or adjustable wrench; T-square or level. ASSEMBLY Note: Steps A to D are not required for Welded Model. A. Locate both frame channels and place them parallel on the floor, approximately 24 inches apart. The frame channels are stamped on the lower inside surface with R or L on the 23-in. model. The 19-in. model frame channels are symmetrical. Fig. 2 B. Position the rack top channel between the frame channels at the top, and use the #10-32 (23-in.) or #12-24 (19-in.) x ½ pan head screws to attach the parts. See Fig. 2. Do not tighten the hardware at this time. C. Attach one bottom frame floor angle at the base of the two channels, and use the 3/8-16 hardware to attach the bottom frame floor angle to the channels. Do not tighten this hardware at this time. D. Turn the unit over and attach the rear bottom frame floor angle with 3/8-16 hardware, and add the #10-32 or #12-24 hardware to attach the rack top loosely to the frame channels. E. Raise the unit and loosen the front four 10-32 or 12-24 x ½ pan head screws at the top. Provide approx. ¼ of thread. Assemble the top Horizontal Trough onto the 10-32 or 12-24 hardware and tighten. F. Using a T-square or level, align the rack unit and tighten the 10-32 or 12-24 and 3/8 hardware. G. Attach the bottom horizontal cable trough at the lowest four hole positions on the frame channels with 10-32 or 12-24 x ½ pan head screws. Installation Instructions PX101425 page 3/9

EQUIPMENT INSTALLATION Your Copper / Fiber Manager Rack is provided with two mounting rails with a standard 5/8-5/8-1/2 rack spacing pattern of tapped #10-32 (19 ) or #12-24 (23 ) holes. For ease of panel and equipment alignment from rail to rail, arrows are stamped every 7.00 (four 1.75 rack units) on the face of the rail on the 23-po model and both sides on the 19-po model. MOUNTING HOLE PATTERN To secure the Copper / Fiber Manager Rack to the floor, drill holes as per the pattern shown in Fig. 3. FIG. 3 GROUNDING STUD ¼-20 x ½ long Grounding Studs are provided centered inside the left and right frame channels at a location 6 up from the bottom. A ¼-20 hex nut with a captive external tooth lock washer (Kep nut) and a loose ¼ external tooth lock washer is provided for attachment of ground lug (not supplied). The loose lock washer is to be installed under the ground log and the lock washer/nut assembly used to secure the ground lug in place. Installation Instructions PX101425 page 4/9

INSTALLATION INSTRUCTIONS Vertical Cable Management Channel (Copper Application) AX101180 - BLACK UPON RECEIPT OF YOUR Vertical Cable Management Channel Great care has been taken to insure that your Vertical Cable Management Channel arrives safely. If upon receipt any damage is noted, the carrier should be notified immediately to file a damaged freight claim. The Vertical Cable Management Channel is mounted to the side of a Copper / Fiber Manager Rack (not shown in this illustration). The Vertical Cable Management Channel is shipped unassembled. An assembly hardware package is provided in order to assemble the unit. COMPONENTS QTY. PART DESCRIPTION 2 A MAGNET BRACKET 1 B VERTICAL TROUGH 1 C VERTICAL PLATE 1 D DOOR WELDMENT ASSEMBLY HARDWARE QTY. DESCRIPTION 6 MS 10-32 X 3/8 TRUSS HD 8 #6-32 ACORN NUTS FIG. 1 Installation Instructions PX101425 page 5/9

ASSEMBLY The following tools are required for assembling the Vertical Cable Management Channel: Phillips screwdriver; 5/16 open or adjustable wrench. A. The Vertical Cable Management Channel is attached to the frame channels. The vertical plate is symmetrical and may be mounted on either side of the Communication Rack. Loosely insert one #10-32 x 3/8 truss head screw into the uppermost tapped hole on the middle (outside holes used for fiber model) of the frame channel, leaving at least 1/8 of threads exposed. In the same fashion, add a second screw directly below the first. Hang the vertical plate on the two screws by passing them through the upper two key ways on the vertical plate. See figure 2. Note: The upper and lower threaded studs point away from the rack. STUDS FIG. 2 B. Hang the Vertical trough on the same two screws. Add the other #10-32 screws and tighten. C. Attach one magnet bracket to the studs at the top of the Vertical Cable Manager, using the #6-32 acorn nuts. See figure 3. Attach the lower magnet bracket in the same manner. D. The vertical cable manager door is attached by inserting the lower hinge pin into the pivot hole on the magnet bracket. Move the spring loaded pin on the upper hinge and insert into the upper magnet bracket. Fig. 3 Installation Instructions PX101425 page 6/9

INSTALLATION INSTRUCTIONS Vertical Cable Manager Channel (Fiber Application) AX100932 - GREY AX100933 - BLACK UPON RECEIPT OF YOUR Vertical Cable Management Channel Great care has been taken to insure that your Vertical Cable Management Channel arrives safely. If upon receipt any damage is noted, the carrier should be notified immediately to file a damaged freight claim. The Vertical Cable Management Channel is mounted to the side of a Copper / Fiber Manager Rack (not shown in this illustration). The Vertical Cable Management Channel is shipped unassembled. An assembly hardware package is provided in order to assemble the unit. COMPONENTS QTY. PART DESCRIPTION 1 0007 VERTICAL CABLE CHANNEL 1 0008 DOOR 1 0029-1 MAGNET BRACKET -1 1 0029-2 MAGNET BRACKET -2 10 0012 CABLE GUIDE ASSEMBLY HARDWARE QTY. DESCRIPTION 8 #6-32 ACORN NUT (for Magnet Brackets) 22 1 TUFLOK FASTENER (for Cable Guides) 6 10-32 x 3/8 TRUSS HEAD SCREW (for Vertical Cable Manager) 20 2 FLAT WASHER (for Cable Guide) 1 Two (2) spares TUFLOK fasteners are supplied. 2 Use Flat Washer (if required) to stiffen the Cable Guides. Installation Instructions PX101425 page 7/9

ASSEMBLY (SEE FIGURE 1 AND 2 FOR MORE DETAILS.) The following tools are required for assembling the Vertical Cable Management Channel: Phillips screwdriver; 5/16 open or adjustable wrench. A. The Vertical Cable Management Channel is symmetrical and may be mounted at the front or rear, on either side of the Copper / Fiber Manager Rack. Loosely insert one 10-32 x 3/8 truss head screw into the uppermost tapped hole on the side (middle holes used for the copper model) of the frame channel, nearest the top horizontal trough, leaving at least 1/8 of threads exposed. In the same fashion, add a second screw directly below the first. Hang the Vertical Cable Management Channel on the 2 screws by passing them through the upper (2) key ways on the Vertical Cable Management Channel. Add the other #10-32 truss head screws and tighten. B. Attach one magnet bracket to the two studs at the top of the Vertical Cable Management Channel, using the 6-32 acorn nuts. Insert the other end of the magnet bracket into the two smaller holes on the top horizontal trough, and attach with two #6-32 acorn nuts. See figure 1 and 2. Attach the lower magnet bracket in the same manner. C. The Vertical Cable Management Channel door is attached by inserting the lower hinge pin into the pivot hole on the magnet bracket. Move the spring loaded pin on the upper hinge and insert into the upper magnet bracket. D. If both vertical cable channels are to be assembled on the same frame channel, note three alignment holes to one side of the vertical row of holes. Use three TUFLOK fasteners to hold the front and rear in line. CABLE MANAGEMENT The cable guides may be used as needed to prevent exceeding minimum radius when installing fiber optic cable and also as slack cable take-up spools. The cable guides are applied by inserting the plastic TUFLOK fasteners through the holes in the cable guides and into the holes in the vertical cable channel locked in place by pushing the head in until seated flush in the fastener flange. To relocate the cable guides, the fastener can be removed with a Phillips head screwdriver, and the cable guides can be removed or relocated to another position. The cable guide may be installed with the radius facing either up or down. Installation Instructions PX101425 page 8/9

Figure 1 Figure 2 Top View Installation Instructions PX101425 page 9/9