Parallel AMX AC Power Systems

Similar documents
AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

ASX Series. High-Density AC Test Power Single and Three Phase Switchmode AC Power Sources. T h e P o w e r o f E x p e r t i s e.

AC POWER SOURCE CATALOG

DCR DC Output Module

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

G Series. Advanced Test Equipment Rentals ATEC (2832) AC Power Systems. 6 to 90 kva 45 to 5,000 Hz

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

AC POWER SYSTEMS CATALOG

Applications. Other applications include:

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

California Instruments MX Series II kva V A / Phase. Overview

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

Advanced Test Equipment Rentals ATEC (2832)

PROGRAMMABLE AC POWER SOURCE

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

3B SERIES AC & DC LOADS

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

UPC-32E / UPC-12E PACIFIC OPERATION MANUAL PROGRAMMABLE CONTROLLERS FIRMWARE V5.23 AND LATER POWER SOURCE

Configurations The RS90 delivers up to 90 kva of AC or AC + DC power. In DC mode, 50% of the AC power level is available.

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

AFX Series. "Innovating Solutions for Control and Monitoring of Power" 6 kva/kw to 150 kva/kw

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

UPC-3 / UPC-1 PACIFIC OPERATION MANUAL PROGRAMMABLE CONTROLLERS FIRMWARE V5.22 AND LATER POWER SOURCE

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Model 61511/61512/61611/61612

AC/DC Power Sources ACS Series

Arbitrary/Function Waveform Generators 4075B Series

AC/DC Power Sources ACS Series

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

In addition to these standard waveforms, user defined waveform can be downloaded over the bus.

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Designed with self-diagnostic routine and protections

Advanced Test Equipment Rentals ATEC (2832)

California Instruments MX Series II kva V A / Phase. Overview

BOP 1 KILOWATT 1000 WATTS OF FOUR-QUADRANT BIPOLAR POWER FROM KEPCO AN ISO 9001 COMPANY

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Arbitrary/Function Generator AFG1000 Series Datasheet

California Instruments Ls Series VA V A kva Programmable AC Power Source / Analyzer

SP300VAC1500W Programmable AC Source

Models 31120/31120A/31180/31180A Programmable AC Power Source

SP300VAC600W Programmable AC Source

250 / 500 Vdc. Advanced Features. Performance. Reliance. Brilliance.

Agilent 83711B and 83712B Synthesized CW Generators

PROGRAMMABLE AC POWER SOURCE MODEL 61511/61512/61611/61612

AC Power Sources. Newtons4th Ltd

Function/Arbitrary Waveform Generator

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

DG5000 Series Specifications

WaveStation Function/Arbitrary Waveform Generators

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

IT7600 High Power Programmable AC power supply

R&S SMB100N SIGNAL GENERATOR

RS232. DC POWER SUPPLY 20kW 3 RANGES

Because you can t afford downtime

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Model MHz Arbitrary Waveform Generator Specifications

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

Voltech PM3000ACE UNIVERSAL POWER ANALYZER

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

Models 296 and 295 combine sophisticated

DECLARATION OF CONFORMITY

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Model 865 RF / Ultra Low Noise Microwave Signal Generator

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

Power Processor - Series 700F 10KVA to 150KVA

AUM FAMILY Programmable DC Power Supplies

4 K to 512 K words (2 n, n = 12 to 19) or 2 to 10,000 control points (linear interpolation between control points)

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Arbitrary/Function Generators AFG3000C Series Datasheet

User-selectable output bus voltages for optimized voltage/current matching to load requirements.

WaveStation Function/Arbitrary Waveform Generators

15. Specifications WF1947/WF

WaveStation Function/Arbitrary Waveform Generators

Arbitrary power supplies. 160 W to 5200 W

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Agilent 81180A Arbitrary Waveform Generator

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

Programmable AC Power Source Model 9801

Agilent 6800 Series AC Power Source/Analyzer

Function/Arbitrary Waveform Generator

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

22 kw 4Q POWER AMPLIFIER RS232

ArbStudio Arbitrary Waveform Generators

8-Channel 196 ksa/s Digitizer plus DSP

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Multifunctional AC Power Supply. PCR-LA Series

Racal Instruments. Product Information

GE+ Grid Emulator. Key features. Highlights. High-Resolution and Dynamics. Efficiency and Flexibility. Smooth Integration. Harmonics Generation

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

5500A. Multi-Product Calibrator. Extended Specifications 2005

TOSHIBA International Corp

Transcription:

Parallel AMX AC Power Systems 8kVA to 30kVA 20-5,000 Hz 1Ø4 0-338VL-N 2Ø4 0-600V L-L 4 0-338V L-N /585V L-L Standard Features: Master/Slave Operation of 2 to 5 AMX AC s provides AC Power Levels to from 8KVA up to 30KVA Advanced Linear Amplifiers Provide Very Low Voltage Distortion, No Switching Noise, Fast Voltage and Current Slew Rates, Exceptionally Low Output Impedance and High Peak Current Capability 1, 2, or 3 Phase Output Form Selectable from Front Panel or Bus Command 20 to 5,000 Hz. Operation 5Hz to 50KHz small signal bandwidth, 3dB at 10% of Full Voltage Precision Voltage Programming 0.05% with Continuous Self-Calibration (CSC) engaged True-RMS Metering of Volts, Amps, and Power GPIB (IEEE-488.2) or RS-232 Interface Waveform Library Arbitrary Waveform Generator 99 Programs with Associated Transients for Static and Dynamic Test Applications UPC Studio Software Suite Available Options: T-Versions Include Transformer Assembly for Higher Voltage s Fully Installed and Wired in Industrial Strength Instrument Cabinet with Caster Base Programmable Output Impedance Harmonic Analysis and Waveform Synthesis UPC Test Manager Software Application IEC Test Sequence Available for IEC 61000-4-11, -4-13, -4-14, -4-27, -4-28 and -4-34 AC Immunity Testing UPC Manager Software Suite Master the Power of the Wave! UPC Manager Software gives you the tools necessary to quickly and easily operate your AC. With our graphical interface control all areas of your AC testing with simple presets, user prompts, test sequences, test plans and custom reports.. Parallelable AMX Models These special version AMX units are designed to easily parallel in a master slave configuration to allow high power cabinet systems to be created ranging from 8kVA to 30kVA. Either 4.5KVA or 6KVA AMX/AMXT units are used as building blocks for these power racks. The versatility of the Master/Slave Paralleling option provided by the 140/160/345/360AMX and 140/160/345/360AMXT AC s provide the operator with a wide variety of options using a building block approach to higher capacity linear AC systems. Each parallelable group of AC Power Sources requires at least one Master (/MST) unit with either UPC-12 or UPC-32 controller and one or more Slave (/SLV) units. Any /MST unit can be used as a / SLV with another /MST unit by setting a rear panel mounted switch. This feature provides great flexibility for reconfiguring multiple units into a larger power system as demanded by changing application requirements. As a member of Pacific's AMX-Series popular family of high performance Linear AC s, these AMX systems offer the same absence of output switching noise and very low voltage distortion, ease of installation, and high AC waveform fidelity as found in Pacific's single chassis Linear AC s. The Leader in AC Power Technology An early pioneer in the development solid-state power conversion equipment, Pacific continues to develop, manufacture, and market both linear and highperformance PWM AC s. Pacific s reputation as a market and technology leader is best demonstrated by its continuing investments in both research and development and world-wide customer support. With corporate owned offices in the United States, France, the United Kingdom, and China, local personalized support is always available. THE POWER OF EXPERTISE FREQUENCY CONVERSION AEROSPACE R & D MILITARY MANUFACTURING CUSTOM

Output Ratings Single Phase Parallable AMX Models (parallel up to five like units to configure up to 30kVA System) Model 3 Rated Power (VA) Output Form Output Voltage s Current per Phase (A rms ) Direct (T) 1.5:1 (T) 2.0:1 (T) 2.5:1 Input Power Form Frequency (Hz) Height in/mm/u Transformer Chassis Weight (Lbs/Kg) Transformer Chassis 140AMX(T) 4000 1Ø/2Ø 0-135/270 -UPC12/MST 1 32/16 21.3/10.7 16/8 12.8/6.4 140AMX (T)/SLV 2 4000 1Ø/2Ø 0-135/270 32/16 21.3/10.7 16/8 12.8/6.4 160AMX(T)- 6000 1Ø/2Ø 0-135/270 UPC12//MST 1 48/16 160AMX(T)/SLV 2 6000 1Ø/2Ø 0-135/270 48/16 Three Phase Parallable AMX Models (parallel up to five like units to configure up to 30kVA System) Model 3 Rated Power (VA) Output Form Output Voltage s Current per Phase (A rms ) Direct (T) 1.5:1 (T) 2.0:1 (T) 2.5:1 Input Power Form Frequency (Hz) Height in/mm/u Weight (Lbs/Kg) 345AMX(T) 4500 5 1Ø/2Ø 0-135/270 -UPC12/MST 1 36/12 18/16 14.4-4.8 0-135/234 12/ø 6/ø 4. 345AMX (T)/SLV 2 4500 5 1Ø/2Ø 0-135/270 36/12 18/16 14.4/4.8 0-135/234 12/ø 6/ø 4. 360AMX(T)- 6000 6 1Ø/2Ø 0-135/270 UPC12//MST 1 48/16 0-135/234 16/ø 10.7/ø 6.4/ø 360AMX(T)/SLV 2 6000 6 1Ø/2Ø 0-135/270 48/16 20-5000 ((PS): 14/356/8U 0-135/234 16/ø 10.7/ø 6.4/ø NOTES: 1. Parallelable Master (/MST) supplied with UPC-12/32 Controller. provided with Master/Slave mode select switch on rear panel 2. Dedicated Slave (/SLV) requires master unit of same model. No UPC required for Slave units. 3. Complete Model number for basic unit shown. 4. MST formerly referred to as M5283, SLV formerly referred to as M5283/M5304. 5. 3kVA in Form 2/ Split phase mode 6. 4kVA in Form 2/ Split phase mode AMX Specifications (PF = 1.0, V out > 25% F.S.) Output Frequency Line Regulation Load Regulation Output Distortion Ripple and Noise Response Time Full Power 20-5,000 Hz Direct Coupled 45-5,000 Hz Transformer Coupled 0.1% max for a ±10% line change Direct Coupled s: 0.25% 20 to 2,000 Hz. 0.50% 2,000 to 5,000 Hz. Improves to less than 0.03% with external sense and CSC enabled. Transformer Coupled s: 1:5:1 2% 2:0:1 4% 2:5:1 5% Improve to < 0.1% with external sense and CSC enabled. 0.1% THD AVG 45 to 1,000 Hz 0.25% THD AVG 20 to 5,000 Hz -72dB 5 µsec typ. For step load change. Small signal bandwidth = 5 Hz to 40 KHz 2012 Pacific, Inc. Specifications subject to change without notice. DS#6AMXMSTSLV1112 Page 2 of 6

Input Power Requirements () Refer to 140AMX/140AMXT, 160AMX/160AMXT, 345AMX/345AMXT or 360AMX/360AMXT Data sheets for specific model Input Power requirements. Note MST and SLV have same input requirements as respective standard AMX models. Thermal and Power Factor Rating Curves Rated Continuous Load Current as a Function of Ambient Temperature. Data is shown for combined system configuration. Power Factor Rating Curves per chasis THERMAL RATING -AC CURRENT RMS Short tem overloads to 150% of rated current are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line and temperature conditions. Rated Power Factor and Output Voltage at Nominal Input Line. Data is shown for individual MST or SLV chassis. Multiply Output Current by number of units to obtain total Output Current. 140AMX 160AMX 345AMX 360AMX OUTPUT VOLTAGE AC VOLTS RMS Short tem overloads to 150% of rated current are permitted. Operating time before thermal shutdown or circuit breaker trip varies from seconds to several minutes depending upon line and temperature conditions. 2012 Pacific, Inc. Specifications subject to change without notice. DS#6AMXMSTSLV1212 Page 3 of 6

Typical System Configuration Examples Single Phase Parallable AMX Models Output Power 8kVA (2 x 4kVA) 12kVA (2 x 6kVA) 18kVA (3 x 6kVA) 24kVA (4 x 6kVA) Number of Master Units Master Model Number Number of Slave Units AMX Power Systems Slave Model Number Max. Current Number of Chassis Total Height 1 140AMXT-UPC12/MST 1 140AMXT/SLV 64A @ 125V 2 140AMXT-UPC12/MST 0-32A @ 250V 1 160AMXT-UPC12/MST 1 160AMXT/SLV 96A @ 125V 2 160AMXT-UPC12/MST 0-48A @ 250V 1 160AMX-UPC12/MST 2 160AMX/SLV 144A @ 125V 2 160AMX-UPC12/MST 1 160AMX/SLV 48A @ 250V 3 160AMX-UPC12/MST 0-1 160AMX-UPC12/MST 3 160AMX/SLV 192A @ 125V 2 160AMX-UPC12/MST 2 160AMX/SLV 64A @ 250V 3 160AMX-UPC12/MST 1 160AMX/SLV 4 160AMX-UPC12/MST 0-2 PS + 2 XFMR 22U 2 PS + 2 XFMR 22U 3 PS 24U 4 PS 32U Three Phase Parallable AMX Models Output Power 13.5kVA (3 x 4.5kVA) 18kVA (3x 6kVA) 24kVA (4 x 6kVA) 30kVA (5 x 6kVA) Number of Master Units Master Model Number Number of Slave Units Slave Model Number Max. Current Per Phase 1 345AMXT-UPC32/MST 2 345AMXT/SLV 36A @ 125V 2 345AMXT-UPC32/MST 1 345AMXT/SLV 18A @ 250V 3 345AMXT-UPC32/MST 0-1 360AMXT-UPC32/MST 2 360AMXT/SLV 48A @ 125V 2 360AMXT-UPC32/MST 1 360AMXT/SLV 24A @ 250V 3 360AMXT-UPC32/MST 0-1 360AMXT-UPC32/MST 3 360AMXT/SLV 64A @ 125V 2 360AMXT-UPC32/MST 2 360AMXT/SLV 32A @ 250V 3 360AMXT-UPC32/MST 1 360AMXT/SLV 4 360AMXT-UPC32/MST 0-1 360AMXT-UPC32/MST 4 360AMXT/SLV 80A @ 125V 40A @ 250V 2 360AMXT-UPC32/MST 3 360AMXT/SLV 3 360AMXT-UPC32/MST 2 360AMXT/SLV Number of Chassis Total Height 3 PS + 3 XFMR 33U 3 PS + 3 XFMR 33U 4 PS + 4 XFMR 44U 4 PS + 4 XFMR 33U 4 360AMXT-UPC32/MST 1 360AMXT/SLV 5 360AMXT-UPC32/MST 0 - Flexible Re-Configuration Addition or deletion of power source chassis is easily performed by the user in field. The standard AMX-Series features, such as automatic output form selection, extensive output metering, etc. remain intact. Note that only like models may be paralleled with each other. That is, only 345AMX chassis may be paralleled with other 345AMX chassis, 140AMX with 140 AMX, etc. All Master units are master/slave selectable from rear panel switch. 2012 Pacific, Inc. Specifications subject to change without notice. DS#6AMXMSTSLV1212 Page 4 of 6

Total Control, Metering, and Analysis of AC Power- Simple, Intuitive Operation The UPC Controller is a highly versatile one, two, or three phase oscillator/signal generator designed to control any of Pacific Power s AC s. Only the full featured UPC-12 or UPC-32 Controller is offered for use with the 3 single or three phase parallelable AMX models. Using the front panel keyboard and display, all controller models provide for selection of power source output mode, coupling, voltage, and frequency. Selecting the correct UPC controller for a given application varies with your test requirement, desired features, and price. Both the UPC-12 and UPC-32 Controllers are available with either RS-232 or GPIB remote interface. Commands are structured in accordance with SCPI (Standard Commands for Programmable Instruments). Controller Models Features UPC-12 UPC-32 Output Modes Waveform Library Transient Functions Program Library Programmable Current Limit Programmable Current Protect Programmable Phase Angle CSC (Continuous Self-Calibration) Remote Interface Std Opt Waveform Synthesis/Analysis Prog. Output Impedance DRM Link-Synchronization Line Synchronization Analog Auxilary Input AM-Amplitude Modulation Sync Outputs Zero Crossing Transient Trigger Transient Pedestal 1Ø, & 2Ø 1Ø, 2Ø, & Sine + 15 Editable, 99 Steps Sine + 15 Editable, 99 Steps 99 Programs 99 Programs, 0 to 359, 0 to 359 GPIB RS-232 GPIB RS-232 External Inputs/Outputs Each phase is algebraically summed with UPC waveform and amplified 25X to the direct coupled output. ±10Vpk (20Vpk-pk). One input per phase. Z IN = 600 Ω ±10 Vdc (20Vpk-pk) modulates the output voltage ±100% One input per phase. Z IN = 600 Ω Positive Zero Crossing (0 ) of Phase A analog output Pulse at the start of a transient event. TTL True when a transient is in progress Program Edit and Function Key Ouput Control, Slew, and enable Keys Frequency Voltage Phase Angle ØB and ØC relative to ØA Current Limit Voltmeter True V RMS each phase Ammeter True A RMS and Apk each phase Power Meter True Watts and Volt-Amps each phase Output Control Specifications (l-n) 4 x 16 Character LCD UPC-12 ±0. 5 UPC-32 20-5,000Hz (1) 20-5,000Hz 4 Significant Digits ±0.01% of full scale 0-150/375 0.1V/ 0.5V 0.5% of full scale (CSC Disabled) ±0. 05% referenced to Internal Meter (CSC Enabled) 0-359 ± 1 Function of the number of units in parallel. Output Metering UPC-12 0.05% F.S. ±1% F.S. 0-354 V L-N, 708V L-L 0.1V front panel 50-500Hz, ± 0.25% of rdg. ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S. 0.01A front panel ±0.25% of rdg. 50-500Hz, ± 0.1% F.S. 20-5,000 Hz, ± 0.5% F.S. 1.0 Watt or VA front panel Parameter Control UPC-32 Function of the number of units in parallel. Function of the number of units in parallel. ± 1% full range Output Clock Waveform Synthesis (/HAS Option) Waveform Analysis (/HAS Option) UPC-32, TTL level 1024 x output frequency Waveform Control Creates waveform by entering magnitude as % of fundamental and specified phase angle for 2nd through the 51st harmonic Reports waveform harmonic content and phase angle relative to the fundamental for the 2nd through the 51st harmonic as Total, Odd, and Even harmonic distortion Power Factor Ratio : kw mtr /kva mtr Crest Factor Ratio: Apk/A RMS Freq. Display Calculated and displayed to three digits following the decimal point. ± 1 % full range Calculated and displayed to three digits following the decimal ± 1 % full range 20.00-5,000Hz 10.00-99.99 Hz, 0.01 Hz 100.0-999.9 Hz, 0.1 Hz 1,000-5,000 Hz, 1 Hz ± 0.01% full range 2012 Pacific, Inc. Specifications subject to change without notice. DS#6AMXMSTSLV1212 Page 5 of 6

Temperature Humidity Cooling Per Unit Altitude Heat Dissipation Per Unit Audible Noise Agency Approvals Hardware Programmable Current Limit Programmable Current Protect General/Environmental Operating: 0 to 55 C Storage: -10 to 70 C 0-95%, Non-condensing Front and side forced air intake (600 CFM) with rear exhaust. Automatic Fan Speed Control for low acoustic noise and extended fan life. Operating: 6,500 Ft (1,981m) Storage: 40,000 Ft (12,192 m) 6.5kBTU/ hr (Full kw Load) 65 dba Max @ 1 Meter CE Mark: Safety UL 61010-1 EN 61010-1 EMC EN 61326-1 Protection and Safety Over-current, short circuit, over- temperature A single RMS programmed, average responding, value is provided for all phases. Limits current by reducing output voltage. Allows the power source to operate in "constant voltage" mode, interrupting output when specified current protect limit is exceeded. Height Depth Mechanical Specifications See System Configuration Table for required rack height by configuration Units: 23.5 (597mm) Transformer Module: 3U (5.25, 133mm) (Approx. from front panel to the rear of chassis). Weight Depends on system configuration Mounting Standard 19" rack (483mm). **Cabinet options available, see Hardware Option Below. Hardware Options /M7073 Safety Interlock Normally Open Contacts /M99413 Safety Interlock Normally Closed Contacts /PXXXXXX Software/Firmware Options /Prog-Z Programmable Output Impedance /HAS Harmonic Analysis and Synthesis Test MGR UPC Test Manager License: Create, edit, and execute Test sequences and reports. Ordered as separate line Item Test SEQ Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350), Ordered as separate line item, Requires 'Test' Manager License. IEC-AC-4XX /S RS232 Interface. 38.4kbps /G GPIB Interface, IEEE-488.2. (Standard on UPC-12 and UPC-32) Rack option available in different sizes. Available standard cabinet sizes are: 40 23U Inside rack height 49 28U Inside rack height 61 35U Inside rack height Available integration levels: Basic Installation only. AMX units installed in cabinet, no wiring, no rear screen. Carriage Return Full Integration. Installation in cabinet, input and output wiring, terminal blocks, rear screen. IEC 61000-4 AC Immunity Test Sequences. Includes 4-11, 4-14, 4-27, 4-28 and 4-34. Excludes 4-13 Option. SCU/UPC32-413 IEC 61000-4-13 Inter Harmonic Generator. Required to run 4-13 tests. Includes 4-13 software. Ordering Information Contact Pacific or your local Pacific representative for assistance with specific system configurations. 17692 Fitch, Irvine, CA 92614 USA Phone: +1 949.251.1800 Fax: +1 949.756.0756 Toll Free: 800.854.2433 E-mail: sales@pacificpower.com www.pacificpower.com 2012 Pacific, Inc. Specifications subject to change without notice. DS#6AMXMSTSLV1212 Page 6 of 6