The world is changing but our power is constant...

Similar documents
2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Est Static Frequency Converter. SFX 10kVA - 10MVA

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

SENTINEL XR PLUS 5-10kVA

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

UPS Uninterruptible Power System

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Est Static Frequency Converter. SFX 10kVA - 10MVA

Uninterruptible Power System (UPS) 20 to 320 kva

UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES

Three phase sine wave inverter - 3KVA to 30KVA

TOSHIBA International Corp

TECHNICAL DATA SHEET B9600FXS kva

MAJORSINE Power Inverter

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

Technical Data Sheets

B9000 FXS kVA B9600 FXS kVA

R&D TECHNICAL SPECIFI

GESS Industrial UPS System. Overview


Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

G-NET. 1 kva-10 kva. Rack & Tower UPS

CROSS Chassis from 160 A to 450 A

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

MGETM EPSTM /625/750/800 kva. Three phase UPS

StatiVolt. Inverter UPS Systems. Features. Contents

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

Built To Order 3 Phase UPS Systems

SHORE TO SHIP FREQUENCY

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

will do its best to manufacture products in excellent quality with continuous R & D.

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

User s Manual Before using the inverter, you need to read and save the safety instructions.

USER S MANUAL. 3KSS6050/ nd Edition

ACPOWER. Professional Power Solution Provider ISO 9001: 2008

Gamatronic SVR Series kva Microprocessor Controlled Automatic Voltage Stabilizer

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Gutor PxW AC UPS Designed for North American Market

Microcare Pure Sine Wave Bi-Directional Inverters

USER S MANUAL. 1KSS60400/ ST Edition

Introduction: TAS PowerTek Ltd. MAVROS

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

MYS WWSP PLUS III POWER UNIT

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Dale Power Solutions Ltd

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

Power IT LV Active Filters PQFA - PQFL - PQFT

Series PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10

InfraStruXure Manager v4.x Addendum: Building Management System Integration

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Modbus Register Map: InfraStruXure Symmetra 3-Phase Absolute Starting Register Number, (Decimal)

EL-AC Electronic Load

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

Pure Sine Wave Inverter

MARINE POWER CONVERSION & CONSULTING

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Building Intelligence

NAME OF (VENDOR/MANUFACTURER) Clause No. Clause Description Comments, if any Remarks, if any

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

Data Sheet. RISH Master Record %THD

Technical Data Sheet AMIK 300 / 301

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Programmable AC Power Source Model 9801

Solar Charge Controller Inverter

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Est Triplen Power Distribution Unit TPDU kVA

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

AC Power Sources. Newtons4th Ltd

AC POWER SYSTEMS CATALOG

SPECIFICATION. Online UPS 3000VA

Chloride FP-60Z 5 to 60kVA

Chloride. FP-50z 5 160kVA Industrial AC UPS

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

GE-AC&DC AC&DC Voltage Source

APPLICATIONS DATA SHEET. Product: Single Phase AC/DC Power Meter QI-POWER-485

1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC

Utility Communications Teleprotection Equipment TPT-200

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

3400 Series. Three Phase UPS Specification. 80/100/125kVA

Inverter with static switch a. manual bypass up to 1000 VA

ME3 Three Phase Frequency Converter, Operation and Maintenence.

DCPS Programmable DC Power Supply

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

ahead of time SAG Compensator

Transcription:

The world is changing but our power is constant...... Su-Kam Online UPS Su-Kam Power Systems Ltd. Corporate Office: Plot No. 54, Udyog Vihar Phase VI, Sector-37, Gurgaon-122001, Haryana, India. Tel.:+91-124-4030700,4170500,Fax:+91-124-4038700/1/2. E-mail: info@su-kam.com Website: www.su-kam.com w w w. s u - k a m. c o m

What is Online in an Online UPS? In the case of a regular inverter, the load (appliances and electronic device like computers, air conditioners, etc.) is directly connected to the mains. The power backup comes into play only when the mains go off. How can Online UPS act as a Stabilizer An Online UPS not only provides constant power backup, but it also works to improve your power supply. When the mains are on, it converts the AC (Alternate Current) into DC (Direct Current) and then reconverts it to AC. This removes the fluctuations and other disturbances present in the mains current, and protects your load. You can say it acts as a stabilizer for your load. This process is called Double Power Conversion. In the case of an Online UPS, the load is connected to the mains through the UPS. Therefore the UPS is Online and the current always passes through the UPS itself. Security Check for your Current! Double Conversion is like a security X-ray machine installed at an airport. The luggage going in through the entry is like mains AC. It is converted to DC and corrected for fluctuations and disturbances, just like the X-ray machine scans for suspicious items in the luggage. The output belt is like the pure AC current which is then transferred to the load. ONLINE UPS

` How quick is an Online UPS? Your Online UPS takes next to no time in switching on! Because the UPS home, power disturbances may damage is already online, the switchover time from mains to UPS in case of a high-end electronic equipment like home Where s my cash? Have you ever experienced the cashless problem at the ATMs. You may have put in your PIN and desired amount, but the ATM transaction is cancelled. Even a millisecond of delay in power backup can cause such problems. With an Online UPS installed at ATMs, this problem can be easily solved! power cut is zero. Zero Switchover Time makes the Su-Kam Online UPS the first choice when it comes to mission critical devices, where even a fraction of a second matters. For example, in a hospital, where sensitive medical equipment must always runs at specified voltages and power. Even at theatre systems LCD/Plasma TV etc. Any break in supply or fluctuation can cause problems. Therefore, an Online UPS is absolutely critical, which ensures no break in power even in the case of a power cut. ` ` ` ` ATM `

HOW CAN YOU KEEP AN EYE ON How does an Online UPS protect the load? your Online UPS? Su-Kam offers you what no other Online UPS can. With Su-Kam UPS systems, you can actually control and monitor the UPS performance. This can be done through the Power Doc UPS monitoring system, which is a unique innovation by Su-Kam. Your Online UPS not only provides you power backup when you need it, but it also protects the load from disturbances or fluctuations. It does this by a process called Galvanic Isolation. This ensures maximum safety for high-risk applications like satellite systems, air traffic control systems, internet nodes, bank transactions, etc. It also protects your system from valuable data loss, interruption, errors, crashes or shutdowns. This means that there is a complete physical separation between the Input and Output. This is important, because any disturbance in the mains supply is not allowed to pass through the separation and travel to the load. In an industrial environment, the level of power distortions can be very high. Also, even at home, sometimes heavy electrical work in neighbouring areas like welding work etc. can disturb the power supply. Galvanic Isolation ensures maximum security for the load in such circumstances. In fact, with Galvanic Isolation, the Output can be grounded, in accordance with to international and local standards. Input Current Q. How does the Power Doc work? The Power Doc works with the help of a simple software installed in your PC called the Power Manager. This software acts as a transmitter that keeps you constantly updated about your UPS system. 1. The Power Manager constantly updates information regarding the output voltages, battery voltages and other important parameters. 2. The software keeps a log of important data like input and output voltage, input and output Galvanic Isolation Galvanic Isolation - The Water Filter Effect frequency, battery voltage, etc. so that the user can check the UPS performance at any time. This can also help predict any future problems. 3. The user can shut down the system automatically without individually switching off each PC. In fact the user can also prioritise the shutdown procedure allowing for a sequential shutdown of various system components, thereby protecting critical data and also unsaved files. 4. The software uses the standard TCP/IP communication protocol and supports all operating systems including Windows. Output Current

1 Phase ONLINE UPS Monitoring software Software Functions Graphical Monitoring of the UPS status: An easy to use powerful tool that allows monitoring and controlling the UPS systems. Input Voltage, Input Frequency, Output Voltage, Output Frequency, Battery Status, Load Status and Overload Status can be automatically monitored by it. There are graphical versions for both Windows and Linux. Detailed Display of all the UPS Data: Provides on screen, all the data required to make an accurate and speedy diagnosis of the UPS operation. Alarm Notification via e-mail and SMS: Can be configured to automatically notify an alarm via an e-mail or SMS message. In case of any critical error, it pops up the message on screen. Can you monitor your Online UPS long distance? 3 Phase ONLINE UPS Monitoring software Programming the UPS Commands: The commands normally carried out by the users are programmed so that these are performed automatically e.g. shutting down and switching the server back on, UPS battery test, etc. Remote Monitor your UPS! You can also remote monitor your Su-Kam Online UPS! In fact you can monitor a large number of systems spread out over a large area right from your office desktop. To know more, read on. If you have several UPS systems spread out over a large geographical area, it becomes difficult to monitor all of them simultaneously. Therefore Su-Kam offers you the unique Ethernet Based UPS Monitoring Software. Operating through your Local Area Network (LAN), you can monitor all your systems through a single window. The software generates an automatic e-mail in case of any alert, providing you the contact person and contact details at the site of installation, so that problems can be immediately rectified.

Ethernet Based UPS Monitoring Software Can your UPS bypass the mains voltage? The Su-Kam Online UPS comes equipped with a Bypass feature, which allows the load to run on main supply, when the UPS is under maintenance or service upgradation. Thus it ensure uninterrupted power supply for the load. How does my Su-Kam UPS have extra stamina? The Su-kam UPS is like a long distance runner. It has a Heavy Duty Charger that allows for faster charging. The faster the battery can be charged, the bigger the battery you can use. Therefore, the UPS can deliver sustained power for longer periods of time. It is like a long distance runner who utilizes minimum energy to deliver maximum performance. ROAD MAINTENANCE? USE THE FLYOVER! If you consider the UPS to be a city road, then the Bypass Switch is like a flyover which passes the mains current directly to the load through flyover under maintenance or service upgradation. How do I choose my Su-Kam UPS? Su-Kam Online UPS systems comes in two ranges, namely the IntelliQ and the Sinclair-I Series. The IntelliQ Series operates at lower frequencies and the Sinclair-I Series works at higher frequencies. In fact, the IntelliQ Series comes in three different phase options: 1 phase in 1 phase out 3 phase in 1 phase out 3 phase in 3 phase out

IntelliQ 1 phase in 1 phase out Salient Features: - DSP based PWM technology using IGBT - Double Conversion VFI technology - True Galvanic Isolation - Overload handling capacity up to 300% for 1 sec. - LCD Panel for Input/Output Voltage, Input/Output Frequency, Power & Current Battery Voltage, Mains Fail, UPS on Battery, Inverter ON/OFF, Battery Low/High, Output Low/High Voltage, Overload/Short Circuit etc. - User settable Output Voltage (220/230/240V) - RS-232 Interface software for advanced Power Manager - Fixed settable heavy duty charger for long backup - Generator compatible Range: 1KVA 10KVA I/P VOLT: 201.5V I/P FREQ:48.0Hzt O/P PWR: 3775VA O/P FREQ:50.0Hz O/P VOLT: 230.15V O/P CRNT: 23.4At SELF TEST IN PROGRESS... LCD DISPLAY MESSAGES * ATTENTION * OVERLOAD >150% SYSTEM CAPACITY 10KVA-192V D.C VOLT : 204.1V INVERTER ONt * PROTECTION * BATTERY LOWt 1 Phase Input - 1 Phase Output TECHNICAL SPECIFICATIONS Type 1 Phase Input - 1 Phase Output Series IntelliQ Online UPS Technology DSP based Double Conversion Online UPS system with true galvanic isolation Ratings Model Capacity INPUT No. of Phases 1 KVA IQ111K 1 KVA 2 KVA IQ112K 2 KVA 3 KVA IQ113K 3 KVA 1Phase-3Wire P,N,E 5 KVA IQ115K 5 KVA 7.5 KVA IQ117.5K 7.5 KVA 10 KVA IQ1110K 10 KVA Voltage Range 170 V - 280 Volts AC Input Frequency Range 47 to 53Hz. OUTPUT Power 700 W 1600 W 2400 W 4000 W 6000 W 8000 W Load PF Range 0.8 lagging Phase 1 Phase -2 Wire (P,N) Output Waveform Pure Sine Wave Voltage 230 V +/-1% Frequency 50Hz +/-0.1% Load Crest Factor > 3:1 Output Voltage THD <=3% on Linear Load Loading Capacity 110% for 2 Minutes BY-PASS Maintenance By-Pass Available BATTERIES No. of 12V Batteries 4 15 15 15 16 16 Voltage 48 VDC 180 VDC 180 VDC 180 VDC 192 VDC 192 VDC Battery Charging current 0.8 Amp to 8 Amp 1 Amp to 10 Amp Battery Recommendation From 7.2 Ah to 200 Ah Battery Self Test Automatic & Manual USER INTERFACE Communication port RS-232 Server and Client Operating System Windows95/98/NT/2000/XP GENERAL Indication LCD panel Alarm Mains Failure, Battery Low, Over Load Short Circuit Protection Short Circuit, Over Voltage & Under Voltage Protection. Cooling Forced Air Cooling UPS Efficiency > 85% Operating Temperature 0-45DegC Operating Humidity 95% Condensing Monitoring Software Additional Software available for remote monitoring Accoustic Noise <45 Db at 1 meter Protection Class Ip20 UPS Weight 32Kg 40Kg 57.5Kg 71.5Kg 93Kg 108Kg (Without Batteries) (Without Batteries) (Without Batteries) (Without Batteries) (Without Batteries) (Without Batteries) Dimension (L X W X H) (490 X 225 X 350)MM (550 X 350 X 325)MM (475 X 350 X 610)MM (475 X 350 X 610)MM (550 X 350 X 660)MM (550 X 350 X 660)MM

IntelliQ 3 phase in 1 phase out Salient Features: - DSP based PWM technology using IGBT - Double Conversion VFI technology - True Galvanic Isolation - UPS Auto Self Test on L CD Panel - User settable Output Voltage (220/230/240V) - Static Bypass Switch (optional) - Hot Standby (optional) - RS-232 Interface software for advanced Power Manager - Works on any input phase sequence - Field settable heavy duty charger for long backup Range: 10KVA 25KVA DSP ONLINE UPS IntelliQ Series AUTO MODE * PROTECTION * BATTERY LOW SU-KAM WELCOMES YOU O/P VOLT: 230.15V O/P CRNT: 35A * PROTECTION * OUTPUT SHORT CKT LCD DISPLAY MESSAGES PROTECTION MESSAGES O/P PWR: 24775VA O/P FREQ:50.0Hz SYSTEM CAPACITY 10KVA-360V DC * PROTECTION * BATTERY HIGH SELF TEST: PASS DC VOLT:406.OV INVERTER ON * PROTECTION * OVERLOAD SHUTDOWN 3 Phase Input - 1 Phase Output TECHNICAL SPECIFICATIONS Type 3 Phase Input 1 Phase Output Series IntelliQ Online UPS Technology DSP based Double Conversion Online UPS with true Galvanic Isolation Ratings 7.5 KVA 10 KVA 15 KVA 20 KVA 25 KVA Model IQ317.5K IQ3110K IQ3115K IQ3120K IQ3125K Capacity 7.5 KVA 10 KVA 15 KVA 20 KVA 25 KVA INPUT No. of Phases 3 Phase- 4 Wire Voltage Range 310 V 480 Volt AC Input Frequency Range 45-55 Hz OUTPUT Power 6000 W 8000 W 12000 W 16000W 20000 W Load PF Range 0.8 lagging Phase 1 Phase -2 Wire (P,N) Output Waveform Pure Sine Wave Voltage 230V ± 1% Frequency 50Hz +/-0.1% Load Crest Factor > 3 :1 Output Voltage THD <=3% on Linear Load Loading Capacity 110% for 5 Minutes/ 125% for 1 Min/ 150% for 10 Sec BY-PASS Capacity 125% continues Maintenance By-Pass Available BATTERIES No. of 12V Batteries 30 Voltage 360 V DC Battery Charging current 1 Amp to 10 Amp Battery Recommendation From 7.2 Ah to 200 Ah Battery Self Test Automatic & Manual USER INTERFACE Communication port RS-232 Server and Client Operating System Windows95/98/NT/2000/XP GENERAL Indication LCD panel Alarm Mains Failure, Battery Low, Over Load Short Circuit Protection Short Circuit, Over Voltage & Under Voltage Protection. Cooling Forced Air Cooling UPS Efficiency > 90% Operating Temperature 0-45DegC Operating Humidity 95% Condensing Monitoring Software Additional Software available for remote monitoring Accoustic Noise <45 Db at 1 meter Protection Class Ip20 UPS Weight 120 Kg 131 Kg 156 Kg 170 Kg 170 Kg (without Batteries) (without Batteries) (without Batteries) (without Batteries) (without Batteries) Dimension (H X W X D) (700 X 450 X 700) MM (450 X 650 X (450 X 650 X (450 X 700 X 730)MM (450 X 700 X 730)MM WARNING MESSAGES * ATTENTION * LOW BATTERY * ATTENTION * OVERLOAD > 110% * ATTENTION * OVERLOAD >150%

IntelliQ 3 phase in 3 phase out Salient Features: - DSP based PWM technology using IGBT - Double Conversion VFI technology - True Galvanic Isolation - Works on any phase sequence without coming in Battery Mode - LCD Panel for Input/Output Voltage, Input/Output Frequency and Output Power for all 3 phases simultaneously (very useful for monitoring) - User settable Output Voltage (380/400/415V) - RS-232 Interface software - Remote monitoring analysis & control using Powerdoc Software - Auto Self test on LCD Panel - 3-Phase Static Bypass Switch (optional) Range: 5KVA 50KVA *Su-Kam Online UPS* R-O/P Freq: 49.99 Hz Y-O/P Freq: 50.04 Hz B-O/P Freq: 50.04 Hz *Su-Kam Online UPS* R-O/P Volt:230.2 V Y-O/P Freq:50.02 Hz B-O/P Crnt:00.90 A *Su-Kam Online UPS* Y-O/P Volt:230.6 V Y-O/P Freq:49.99 Hz Y-O/P Crnt:20.90 A LCD DISPLAY MESSAGES *Su-Kam Online UPS* R-O/P Volt:230.3 V Y-O/P Volt:230.4 V B-O/P Volt:230.5 V *Su-Kam Online UPS* B-O/P Volt: 230.8 V B-O/P Freq: 50.04 Hz B-O/P Crnt: 20.90 A *Su-Kam Online UPS* R-O/P Power:04180 VA R-O/P Power:04280 VA R-O/P Power:04090 VA 3 Phase Input - 3 Phase Output TECHNICAL SPECIFICATIONS Type 3 phase input - 3 phase output Series IntelliQ Online UPS Technology DSP based Double Conversion Online UPS system with True Galvanic Isolation Ratings Model Capacity 5 KVA IQ335K 5 KVA 7.5 KVA IQ337.5K 7.55 KVA 10 KVA IQ3310K 10 KVA 15 KVA IQ3315K 15 KVA 20 KVA IQ3320K 20 KVA 25 KVA IQ3325K 25 KVA 30 KVA IQ3330K 30 KVA 40 KVA IQ3340K 40 KVA 50 KVA IQ3350K 50 KVA INPUT No. of Phases 3 Phase 4 Wire Voltage Range 310 V 480 Volt AC Input Frequency Range 45 55 Hz OUTPUT Power 4000 W 6000 W 8000 W 12000 W 16000 W 20000 W 24000 W 32000 W 40000 W Load PF Range 0.8 lagging Phase 3 Phase- 4 Wire Output Waveform Pure Sine Wave Voltage 400V ± 2% (P-P), 380V & 415V user selection also available Frequency 50Hz +/-0.1Hz Load Crest Factor > 3:1 Output Voltage THD <=3% on Linear Load Loading Capacity 110% for 8 Minutes/ 125% for 1 Min/ 150% for 13 Sec BY-PASS Capacity 125% continues Maintenance By-Pass Available BATTERIES No. of 12V Batteries 30 Voltage 360 V DC Battery Charging current 1 Amp to 10 Amp Battery Recommendation From 7.2 Ah to 200 Ah Battery Self Test Automatic & Manual USER INTERFACE Communication port RS-232 Server and Client Operating System Windows95/98/NT/2000/XP GENERAL Indication LCD panel Alarm Mains Failure, Battery Low, Over Load Short Circuit Protection Short Circuit, Over Voltage & Under Voltage Protection. Cooling Forced Air Cooling UPS Efficiency > 90% Operating Temperature 0-45DegC Operating Humidity 95% Condensing Monitoring Software Additional Software available for remote monitoring Accoustic Noise <45 Db at 1 meter Protection Class Ip20 UPS Weight (Without Batteries) 105Kg 125Kg 155Kg 198Kg 210Kg 223Kg 240Kg 423.5Kg 423.5Kg Dimension (L x W x H) (450 X 700 X (450 X 700 X (450 X 700 X (450 X 700 X (450 X 700 X (500 X 800 X 750)MM (500 X 800 X 750)MM (810 X 755 X 1460)MM (810 X 755 X 1460)MM

Sinclair-I 1 phase in 1 phase out Salient Features: - Microcontroller based High Frequency design using IGBT - Active Power Factor Correction with input power factor > 0.98 for 10% to 100% load - Reduced hardware for increased reliability - High efficiency in both Mains and Battery Modes - Extra wide Input Voltage window range minimizing battery usage and enhancing battery utilization and life - Noiseless operation - SMPS Based Pure DC Charger with extended power, extended battery life and lower maintenance cost - Inbuilt static bypass - High crest factor, handles all high-inrush current loads without need for power rating upgrade - Multiple protection features to ensure load safety - DC-start function - User friendly LCD display - Heavy duty charger for long backup - Parallel redundancy is available in 6 and 10KVA - SNMP monitoring (optional) Choice of Power: Sinclair-I UPS is available in two variants a) With External Battery (1-10KVA) for more backup b) With Internal Battery (1-10KVA) for less backup Type Series Technology MODEL Capacity INPUT PARAMETERS No. of Phases Voltage Range Input Power Factor Input Frequency Range OUTPUT PARAMETERS Power Load PF Range Phase Output Waveform Voltage Frequency Load Crest Factor Output Voltage THD Loading Capacity BY-PASS Maintenance By-Pass BATTERIES No of 12V Batteries Voltage Charging Current GENERAL Indication Alarm Protection Cooling UPS Efficiency Operating Temperature Operating Humidity Monitoring Software Accoustic Noise UPS Weight (With Batteries) Dimension (W x D x H) 1 Phase Input - 1 Phase Output TECHNICAL SPECIFICATIONS 1 Phase Input - 1 Phase Output Sinclair-i High Frequency Online UPS Sinclair-i 1kVA IB 1kVA EB 2kVA IB 2kVA EB 3kVA IB 3kVA EB 6kVA IB 6kVA EB 10kVA IB 10kVA EB 1Phase-3Wire (P,N,E) 110-300Volts ± 5Volt(Load dependant) 176-276Volts ± 5Volt >0.97 at Full Load >0.98 at Full Load 46 to 54Hz. 700 W 1400 W 2100 W 4200 W 7000 W 0.65 lagging to 1.0 1 Phase -3 Wire (P,N,E) Pure Sine Wave 220/230/240VAC ± 2% ( selectable ) Synchronization Range 46-54Hz, Slew Rate 1Hz/Sec, Battery Mode (50±0.2) Hz > 3:1 <=3% on Resistive full load 110% ~ 150%: for 0.5s, fault after 30s, 105% ~130%: Transfer to bypass after 10 min. >150%: fault after 300ms, >130%: Transfer to bypass after 1s, shutdown after auto recovery 1 min.(line mode) Static By-Pass 3 8 8 20 20 36VDC 96VDC 96VDC 240VDC 240VDC 1A (8±1)A 1A (8±1)A 1A (8±1)A 2A (4.2±0.2)A 2A (4.2±0.2)A LCD panel Mains Failure, Battery Low, Over Load & Short Circuit Short Circuit, Over Voltage & Under Voltage Protection Forced Air Cooling 85% 85% 85% 88% 88% 0-45DegC 95% Condensing Additional Software available for remote monitoring <=45db at 1 Metre 13.3kg 7kg 32kg 15kg 32.2kg 14.5kg 84kg 35kg 93kg 38kg (145 x 220 x 400)mm (195 x 330 x 455)mm (195 x 330 x 455)mm (260 x 717 x 570)mm (260 x 717 x 570)mm This is recommended for IT Applications.

Static Bypass Switch The Static Bypass Switch takes two sources of power at the input and monitors them continuously to provide the best of the two available power source to the electrical load connected at the output. One source is used as the master and other as the slave. The load runs normally on the master and in case of any deviation of voltage and frequency from defined thresholds the load is instantly transferred to the slave source to provide uninterrupted supply to the load. It is based on solid-state switch's Silicon Controlled Rectifier (SCR) devices so it has no mechanical moving parts and thus requires minimal maintenance. It provides fast transfer time to protect the output Monitoring Software load. The input sources can be a combination of UPS supply, mains supply or generator supply providing sinusoidal output. The Static Bypass Switch has high overload handling capability for safety. Typical applications include Servers, Data Centres, Call Centres, Operation Theatre or any other place which requires redundant power supply with fast transfer time so that load connected at the output does not experience any power break. Su-Kam's Single phase and Three phase static bypass switch ensures high reliability and redundancy of power supply to the critical load. Single Phase Static Bypass Switch (SBS) Micro-controller based design 230 VAC, 50Hz input / output Power: 1KVA - 5KVA, 6KVA - 10 KVA Provides redundant power to load by two independent power sources Operates with two UPS or non-ups power sources (Grid or Generator) providing a sinusoidal output Fast transfer time High surge current capability Compact and robust design Hot swap function of input sources: Servicing of one of the sources can be done without interrupting the power flow to load User friendly LED display RS-232 Communication for monitoring Three Phase Static Bypass Switch (SBS) Digital Signal Controller based design 400 VAC, 50Hz input / output Power: 5KVA - 10KVA, 11KVA - 25 KVA Provides redundant power source for load Operates with any UPS or power source that has a sine wave output Fast transfer time High surge current capability Compact and robust design Hot swap function of input sources: Servicing of one of the sources can be done without interrupting the power flow to load User friendly LCD display RS-232 Communication for monitoring Design TECHNICAL SPECIFICATIONS Microcontroller based design Input Voltage 230V (+15% -25%) Frequency 47 Hz to 53 Hz Output Rating Efficiency >98% Transfer/Retransfer Time Overload Protection Environmental 5KVA, 10KVA Operating Temperature 0-45 C Relative Humidity Audible Noise Indications Communication Hot swap function of input sources Design Specifications of Single Phase (1 phase with neutral) Static By-pass Switch (SBS) 2 to 15 ms (depending on the input condition of source condition - synchronized or unsynchronized) 125% for 10 min, 150% for 1 min and 300% for 10 msec. Input under and over voltage, Output Short Circuit 0-95% non-condensing < 45dB (A) at 1.5 meters Availability of Source 1 & 2 by Graphical LED Display Power flow to load either by Source 1 or 2 Output ON / OFF Overload / Short Circuit RS-232 Communication with PC for display and monitoring Servicing of one of the sources can be done without interrupting the power flow to load. Specifications of Three Phase (3 phase with neutral) Static By-pass Switch (SBS) Digital Signal Controller Based Design Input Voltage 400V (+15% - 20%) Frequency 50 Hz ± 10% Output Rating 10 KVA, 25 KVA Efficiency > 98% Transfer/Retransfer Time 5 to 18 ms (depending on the input condition of source condition - synchronized or unsynchronized) Overload Protection Environmental Operating Temperature 0-45 C Relative Humidity 95% non-condensing Audible Noise Indications Communication Hot swap function of input sources TECHNICAL SPECIFICATIONS 125% for 10 min, 150% for 1 min, 200% for 10 sec and 300% for 10 msec Input under and over voltage Output overload, Output Short Circuit < 45dB (A) at 1.5 meters LCD Availability of Source Priority Source 1 & Source 2 - Voltage & Frequancy Output ON / OFF Overload / Short Circuit RS-232 Communication with PC for display and monitoring Servicing of one of the sources can be done without interrupting the power flow to load

Where all can I use Su-Kam Online UPS? The Su-Kam Online UPS can be used for a variety of applications, where reliable power backup plays an important role. These include: Colour Labs Embroidery Machines Offices Security Systems / Control Room Offices, Workstation and Lan Servers Medical Equipment Plotters Point of Sale (POS) Systems Telecommunication System ATM Machines Air Traffic Control System Satellite System PCs, Workstations, Computer Labs, IT Networks, Internet Nodes/Servers, Plotters, Monitors & Modems, Security Equipment, EPABX Systems, Fax Machines, Networking Products, Point of Sale (POS) Systems, Cash Registers, ATM Machines, SOHO (Small Office Home Office), Data Centres/Offices, Industrial Equipment, Security Systems, Overhead Projector, Local Area Networks (LAN), Telecommunication Systems, Electrical Medical Equipment, Biomedical Equipment, Satellite Systems, Industial Computer-based Machines, Studio Equipment, Video Equipment, Sound Equipment, Printing & Media Equipment, Small Automation Control Equipment, Sensitive electronic or any other computerized systems, Access Control System, and many more.