ILLUMINANCE METER T-10 Series

Similar documents
High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

ILLUMINANCE METER T-10 Series

ILLUMINANCE METER LUMINANCE METER CHROMA METER T-10A /T-10MA/ T-10WSA/T-10WLA CL-200A CL-500A LS-100/LS-110 CS-100A CS-200

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Achieving 100,000 : 1 contrast measurement

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Illuminance Meter. series

CS-2000/2000A. Spectroradiometer NEW

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Konica Minolta LS-110 Specs Provided by

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

ILLUMINANCE METER T-10 Series

Spectroradiometer specbos 1201

Ultimate and Versatile 2D Spectroradiometer is finally released!

Miniaturized Spectroradiometer

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

KFM-1100 AUTO DIGI METER KFM-2100 FLASH METER KCM-3100 COLOR METER

CHROMA METER CS-200. Instruction Manual. Please read before using this instrument.

Spectroradiometer series NEW

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

Broadbandradiometer specbos 1211

MK350 Portable Spectrometer

Color Measurement with the LSS-100P

Spectrophotometer CM-3630 PaperControl Software

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

Photometry for Traffic Engineers...

INSTRUCTION MANUAL PCE-222

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

Ultra low luminance measurement performance of the industry's top-level.

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings.

Photometry for Traffic Engineers...

Measuring the luminance distribution and horizontal illumination on the airports apron. Canon 70D (DSLR) SIGMA 4.5mm/2.8 EX DC Circular Fisheye

QUANTUM PHOTO-METER LX OPERATING INSTRUCTIONS. ... Three decimal points only displayed Overrange reading. Adjust Range. ( X 1000will light up)

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT

JETI Specbos Instruments

E-420. Exceptional ease of use. 100% D-SLR quality. 10 Megapixel Live MOS sensor Shadow Adjustment Technology

Contents. Contents. Part 4. Specification. Part 1. Feature. Feature Merit Configuration. Specification Dimension Diagram

Manual DATALOGGING LIGHT METER - PCE-174

Dawson DSM150. Digital Light Meter User s Manual

Model S471-LED Optometer

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

Colorimetry and Color Modeling

E-520. Built-in image stabiliser for all lenses. Comfortable Live View thanks to high speed contrast AF** 100% D-SLR quality

Basic lighting quantities

E-420. Exceptional ease of use. 100% D-SLR quality. 10 Megapixel Live MOS sensor Shadow Adjustment Technology

Imaging Photometer and Colorimeter

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

The Pro Masterpiece with world's fastest AF* and built-in IS.

COLORMUNKI DISPLAY & i1display PRO

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Nuclear Associates Precision Photometer

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control

PRODUCTION DATA SHEET

<Motion Panorama> 180 Vertical : 2160 x 9600 Horizontal : 9600 x Vertical : 2160 x 6400 Horizontal : 6400 x 1440

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

operating manual iliad for Windows & Mac OS X software application rc81

Microscope-Spectrometer

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

User s Manual /51012/51021 Digital Lux Meter. Keep this manual in a safe place so that you can refer to it when necessary.

INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

SPECTROPHOTOMETER CM-2600d

Problems in Color Proofing from the Colorimetric Point of View

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

High Speed, Multi-point Laser Displacement Sensor HL-D3 SERIES. panasonic.net/id/pidsx/global

User Friendly Interface means: Power through Simplicity

Bench LCR Meter Model 891

Introduction ORANGE PEEL / DOI. Structure size. Color Physical Properties Technical Service Index

Battery Analyzers BA6010 Series

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)

COLOR. and the human response to light

Art Filters, Multi Exposure, Wireless flash, Multiaspect

Comparing Sound and Light. Light and Color. More complicated light. Seeing colors. Rods and cones

spectro-guide Total Appearance Control color and gloss in one unit Easy to use and handle Solid Color

07-Lighting Concepts. EE570 Energy Utilization & Conservation Professor Henry Louie

COLOR and the human response to light

LED Tester BTS256-LED

Art Filters, Multi Exposure, Wireless flash, Multiaspect. Filter

Specifications for Fujifilm FinePix F850EXR 16MP Digital Camera

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

12/02/2017. From light to colour spaces. Electromagnetic spectrum. Colour. Correlated colour temperature. Black body radiation.

Meter COLOR RGB Display. Measuring geometry 45 /0 - circular illumination at 45, measurement at 0. Spectral range.

Electrical Illumination and Design

We bring quality to light. MAS 40 Mini-Array Spectrometer

Dust reduction filter. Live View

Digital Image Processing

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM

LI-1500 Light Sensor Logger

Understand brightness, intensity, eye characteristics, and gamma correction, halftone technology, Understand general usage of color

28-200mm Optical 7.1 x Zoom 10 megapixel CCD 1/2.3-inch type Smooth Imaging Engine 3.0-inch 460,000-dot LCD monitor Electronic level function

DUALMASTER L-558/L-558. Operating Manual

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

Gamma Scientific Display Measurement Systems

Transcription:

ILLUMINANCE METER T-10 Series Accurate and Easy Measurement of Illuminance Adapts To Various System Configurations Modular Systems That Expand With Your Needs Illuminance Meter T-10 <standard receptor head> Used for measurement of a wide range of illuminance ( 0.01 to 299,900 lx ) 0.001 to 29,990 fcd Illuminance Meter T-10M <mini receptor head> Used for measurement of illuminance that cannot be performed with the standard receptor head due to small spaces. The measuring range is the same as T-10 (ø14 mm receptor surface, 1 m cord) ( 0.01 to 299,900 lx ) 0.001 to 29,990 fcd T-10 Illuminance Meter T-10WS (5m cord) / T-10WL (10m cord) Custom order Since the mini receptor head and cord are waterproofed to allow measurement of illuminance under water, this product can be used for control of illuminance in the marine products industry (e.g. fish farming) and outdoor measurement of illuminance on rainy days. T-10M/ T-10WS/ T-10WL WIDE RANGE OF APPLICATIONS Lighting engineers and specifiers R&D at light products manufacturers inspection of light sources at construction sites, government and educational facilities maintenance of lights in factories, offices, and hospitals electrical product manufacturers quality control of light sources at home agricultural and forestry industries. Under water measuring example 1

Main Features Provides multi functions and user-friendly features For basic operation Normal measurement of illuminance Measurement of illuminance difference Display of illuminance difference Display of illuminance ratio Measurement of integrated illuminance Display of integrated illuminance For advanced operation Display of integration time Display of average illuminance Setting of the reference value Color Correction Factor (CCF) Improves measurement accuracy of illuminance under certain light sources (e.g. inside an orange-lit tunnel). Allows connection with a personal computer and continuous recording of illuminance by a recorder Digital output : Use of the RS232C interface (standard accessory) allows the meter to be connected to a personal computer. Analog output : Allows the meter to be connected to a recorder for continuous recording of illuminance. Quick automatic zero adjustment Turning on the meter will perform zero adjustment (no cap required), allowing immediate measurement of illuminance. Auto ranging Range can also be set manually. LCD back-light The LCD back-light turns on automatically when illuminance is low. Uses AA-size batteries. Measures flickering light sources Illuminance Measurement System to Meet Various Needs Allows simple and low-cost multi-point measurement of illuminance (2 to 30 points). Multi-point illuminance measurement system (9 points) For projector etc Multi-point illuminance measurement system (5 points) For lighting at construction sites 2

Relative Spectral Response Relative sensitivity (%) 100 90 80 70 60 50 40 30 20 10 0 The spectral luminous efficiency (λ) Konica Minolta Illuminance Meters T-10/10M 400 450 500 550 600 650 700 750 Wavelength (nm) Ideally, the relative spectral responsivity of the illuminance meter should match V (λ) of the human eye for photopic vision. As shown in the graph at left, the relative spectral responsivity of Konica Minolta Illuminance Meters T-10/10M is within 6% (f1 ) of the CIE spectral luminous efficiency V (λ). CIE ; Commission Internationale de I Eclairage f1 (CIE s symbol) ; The degree to which the relative spectral responsivity matches V (λ) is characterized by means of the error f1. Cosine Correction Characteristics 0 20 100% 20 40 80% 40 Ideal curve Konica Minolta Illuminance Meters T-10/10M Since the brightness at the measurement plane is proportional to the cosine of the angle at which the light is incident, the response of the receptor must also be proportional to the cosine of the incidence angle. For Konica Minolta Illuminance Meters T-10/10M, the cosine response f 2 is within 3%. The graph at left shows the cosine correction characteristics of Konica Minolta Illuminance Meters T-10/10M. The cosine error of T-10/10M are shown in the table right. 60% 60 60 40% 20% 80 80 Incidence angle (deg.) Cosine error (within) 10 ± 1% 30 ± 2% 50 ± 6% 60 ± 7% 80 ± 25% For a photometer head in an illuminance meter, the deviation in the directional response to the incident radiation is characterized by f 2 (ε, ϕ) : where f 2 (ε,ϕ) = Y(ε,ϕ) Y(0,ϕ)xcos ε l Y(ε,ϕ) ε ϕ is the signal output as a function of the angle of incidence; is measured with respect to the normal to the measuring plane or optical axis; is the Azimuth angle. For characterizing the directional response error by a single factor the characteristic f 2 is used: π 85 180 f 2 = f 2 (ε) xsin 2ε dε 0 3

SYSTEM DIAGRAM Adapter for Multi-point measurements Subminiature plug Adapter Unit for Main Body T-A20 LAN(10 BASE-T ) category 5 straight cable Two AA-size batlerys Adapter Unit for Receptor Head T-A21 With LAN category 5 cable 1m (commercially available) Neck Strap Printer (RS-232C) (commercially available) Printer Cable T-A12 Example of multi-point system Example of cable extension Case T-A10 AC Adapter Cap T-A13 (for T-10) Mini Cap T-A14 (for T-10M) Hard Case CL-A10 T-10M T-10 T-10WL Custom models T-10WS <Standard accessories> <Optional accessories> Recepter head AC Adapter T-10 Recepter head T-10M Receptor head T-10WL Receptor head T-10WS Receptor head Custom order SPECIFICATIONS Model Type Receptor Relative Spectral Response Cosine response (f 2 ) Cosine Correction Characteristics Illuminance units Measuring range Measuring function Measuring range User calibration function Linearity Temperature/humidity drift Digital output Analog output Display Operating temperature /humidity range Storage temperature /humidity range Power source Battery life Dimensions Weight Standard accessories Optional accessories Illuminance meter T-10 <standard receptor head> Illuminance metert-10m <mini receptor head> Multi-function digital illuminance meter with detachable receptor head Silicon photocell Within 6% (f1 ) of the CIE spectral luminous efficiency V (λ) Within 3% Within ±1% at 10 ; Within ±2% at 30 ; Within ±6% at 50 ; Within ±7% at 60 ; Within ±25% at 80 Lux (lx) or foot candles (fcd) (switchable) Auto range (manual 5 range at the time of analog output) Illuminance(lx). illuminance difference(lx). illuminance ratio(%). integrated illuminance(lx h). integration time(h). average illuminance(lx). Illuminance 0.01 to 299,900 lx 0.001 to 29,990 fcd Integrated illuminance 0.01 to 999,900 x 10 3 lx h 0.001 to 99,990 x 10 3 fcd h / 0.001 to 9999 h CCF(Color Correction Factor) setting function ±2% ±1digit of displayed value Within ±3% ±1digit (of value displayed at 20 C/68 F ) within operating temperature/humidity range RS-232C 1mV/digit,3V at maximum reading; Output impedance: 10KΩ; 90% response time: FAST setting: 1ms, SLOW setting: 1s 3 or 4 Significant-digit LCD with back-light illumination -10 to 40 C, relative humidity 85% or less (at 35 C) with no condensation -20 to 55 C, relative humidity 85% or less (at 35 C) with no condensation 2 AA-size batteries / AC adapter (optional) 72 hours or longer (when alkaline batteries are used) in continuous measurement Main body : 69 x 161.5 x 30 mm (2-6/16x6-6/16x1-3/16 in.) 69 x 174 x 35 mm (2-6/16x6-14/16x1-7/16 in.) Receptor : ø16.5 x 12.5 (ø11/16 x 1/2 in.) Cord length : 1m ( 3.3 in.) 200g (7.0 oz.) without battery 205g (7.2 oz.) without battery ø3.5mm(ø1/8 in.) subminiature plug for analog output ; Receptor cap ; Neck strap ; Case ; Battery Receptor head ; Adapter for Multi-point ; AC Adapter Specifications are subject to change without notice. 4

CS-200 Accurate measurement Comparable to Spectroradiometers Objective Focus ad Me MAIN FEATURES Perfect match of the spectral response to the CIE color-matching functions Konica Minolta's newly-developed spectral fitting method provides tristimulus values (XYZ = red, green, blue) with significantly higher accuracy than that of conventional tristimulus colorimeters. This is achieved by using the output from 40 sensors to calculate the spectral response corresponding to human eye sensitivity (CIE 1931 color-matching functions). The CS-200 uses 40 sensors for sensitivity covering the entire visible region and multiplies each sensor output by appropriate coefficients. This adjusts the spectral response of the instrument to close to the CIE 1931 color-ma In additon to the 2º Standard O object-color measuremen impossible with conventional tris Relative sensitivity 1.0 0.5 CIE 1931 color-matching functions Spectral response of conventional tristimulus colorimeters Relative sensitivity 1.0 0.5 CIE 1931 color-matching functions Spectral response of the CS-200 380 400 500 600 700 780 Wavelength (nm) CIE 1931 color-matching fun of a conventional tristimulus 380 400 500 600 700 780 Wavelength (nm) CIE 1931 color-matching fun of the CS-200 Compact and lightweight. Battery power is also possible. The compact, lightweight and stylish body allows hand-held operation. The CS-200 can be operated with either four AA batteries (battery indicator function provided) or a special AC adapter. Selectable measuring angle While checking the actual subject, you can select the measuring angle easily according to the application (1º, 0.2º and 0.1º). The aperture mirror eliminates misalignment between the finder target and the actual measuring spot, ensuring accurate aiming. 1º aperture For measurement of general-size areas such as medium and large displays 0.2º aperture For measurement of small areas such as product LEDs 0.1º aperture For measurement of very small areas or of a distant light source Measuring distance and measuring area Minimum measuring area Maximum measuring area Minimum measuring distance Maximum measuring distance Measuring area at 500 mm Measuring area at 1000 mm (Measuring angle) 1 0.2 0.1 1 0.2 0.1 1 0.2 0.1 1 0.2 0.1 1 0.2 0.1 1 0.2 0.1 Without a Close-Up Lens 4.7 1.0 0.5 296 φ 8.5 φ 1.7 φ 0.9 φ 17.7 φ 3.6 φ 1.8 Close-up lens No. 122 2.2 0.5 0.3 4.6 1.0 0.5 128 240 Close-up lens No. 107 0.8 0.2 0.1 1.1 0.3 0.2 43 52 Measuring distance is the distance from the front edge of the metal lens barrel or close-up lens ring. (Unit: mm) 7

TARGET COLOR PEAK/VALLEY SHUTTER MEMORY MEAS SPEED ABS/DIFF BACKLIGHT KEY LOCK CHAR MODE RECALC SHIFT MENU ESC ENTER Data Management Software CS-S10w Standard (Standard accessory) CS-S10w Standard Edition allows users to control the CS-200 with a PC to display the list of measured data or to transfer the data to spreadsheet software. <Functions common to Standard and Professional Editions> List display Interval and average measurements Color space : Lv x y, Lv u' v', LvTΔuv XYZ, dominant wavelength Mode selection : Normal mode Object color mode Instrument control : Average measurement Interval measurement User calibration Data management : Reading and saving files Data management with folders Data evaluation : Observer/Illuminant settings Statistics display for each folder Box tolerance setting SPECIFICATIONS Model Chroma Meter CS-200 Measurement 0.01-200,000 cd/m 2 (Measuring angle 1º) range 0.01-5,000,000 cd/m 2 (Measuring angle 0.2º) 0.01-20,000,000 cd/m 2 (Measuring angle 0.1º) Accuracy 150 cd/m 2 ( for Illuminant A ) Lv ± 2 % ±1digit xy ± 0.002 (Measuring angle 1º) #1 0.01-0.5 cd/m 2 ( for Illuminant A ) Lv ± 0.02 cd/m 2 ±1digit --- (Temperature: 23 C±2 C, 0.5-1 cd/m 2 ( for Illuminant A ) Lv ± 0.02 cd/m 2 ±1digit xy ± 0.007 Relative humidity: 65% max.) 1-10 cd/m 2 ( for Illuminant A ) Lv ± 2 % ±1digit xy ± 0.004 10-200,000 cd/m 2 ( for Illuminant A) Lv ± 2 % ±1digit xy ± 0.003 5000 cd/m 2 ( for Illuminant A ) color filter (R, G, B) xy ± 0.006 Repeatability 0.01-1 cd/m 2 ( for Illuminant A ) Lv 0.01 cd/m 2 +1digit --- (2σ/AUTO) (Measuring angle 1º) #2 1-2 cd/m 2 ( for Illuminant A ) Lv 0.5 % +1digit xy 0.002 (2σ/AUTO) 2-4 cd/m 2 ( for Illuminant A ) Lv 0.5 % +1digit xy 0.001 (2σ/AUTO) 4-8 cd/m 2 ( for Illuminant A ) Lv 0.5 % +1digit xy 0.0005 (2σ/AUTO) 8-200,000 cd/m 2 ( for Illuminant A ) Lv 0.1 % +1digit xy 0.0004 (2σ/AUTO) Measurement AUTO (Automatically set between approx. 1s and 60s) time LTD.AUTO (Automatically set to approx. 1s or 3s) Measurement method Measuring angle Minimum measuring area Minimum measuring distance Observer Color space Measurement synchronization setting range Super-FAST (approx. 0.5 sec/meas.) SLOW (approx. 3 sec/meas.) FAST (approx. 1 sec/meas.) Super-SLOW (approx. 12 sec/meas.) Spectral method, Grating + linear photo diode array 1º, 0.2º, 0.1º (switchable) 0.5 mm 0.1 mm (close up lens) 296 mm (Distance from front edge of metal lens barrel) 2/10 degrees Interface USB 1.1 Power source Battery life Size Weight Operating temperature /humidity range Storage temperature /humidity range Lv x y, Lv u' v', Lv TΔuv, XYZ, dominant wavelength Vertical synchronization frequency : 40.00 to 200.00Hz AC adapter or 4 AA-Size Batteries Approx. 3 hours (continuous measurement / Fast mode / AA-size alkaline cells) 95 mm (W) x 127 mm (H) x 334 mm (L) 1.8 kg (without battery) 0ºC to 40ºC, relative humidity 85% or less (at 35ºC) with no condensation 0ºC to 45ºC, relative humidity 85% or less (at 35ºC) with no condensation SYSTEM DIAGRAM ND Filter (1/10)CS-A6 (1/100)CS-A7 Standard accessories Optional accessories Step Up Ring (40.5-55mm) CS-A26 Close-Up Lens No.107 No.122 Lens Cap Holding Cap CS-A24 (Used during shipment) White Calibration Plate (For 45/0) CS-A20 White Calibration Plate (For d/0) CS-A21 White Calibration Plate Set CS-A22 (including CS-A20 and CS-A21.) DIMENSIONS 47.5 Filter thread diameter ø40.5 ø64 65.6 Standard plane for distance measurements 154 AA-Size Batteries (x4) CS-200 334.3 Soft Case CS-A23 248 AC Adapter USB cable(2m) IF-A17 For tripod screw Angle Finder VN including Adapter ( and Case. ) ND Eyepiece Filter CS-A27 Data Management Software CS-S10w Professional 95 10.5 102.5 PC (commercially available) Data Management Software CS-S10w Standard 127 (Unit: mm) #1 23ºC ±2ºC Lv = 0.01-10 cd/m 2, SLOW, average of 30 measurements Lv = 10 cd/m 2 and higher, SLOW, average of 10 measurements #2 At 0.2º measuring angle, the amount of received light is approx. 1/25 of that for 1º. Therefore, the repeatability becomes the same as that for 1º with 25 times lower luminance. At 0.1º measuring angle, the amount of received light is approx. 1/100 of that for 1º. Therefore, the repeatability becomes the same as that for 1º with 100 times lower luminance. For M5 screw 61.6 70 32 150 For M5 screw 8

CHROMA METER CL-200A De facto industry standard for measuring color temperature! Can also measure illuminance (JIS AA class) MAIN FEATURES Compact and easy to carry The CL-200A's compact body fits in your palm. Battery-powered so it can be taken along and used anywhere. Detachable receptor head The receptor head can be detached and then connected to the main body using a normal LAN cable*, making it easy to install the sensor in an inspection system. *! Optional Adapter Units required for receptor head and main body. Data transfer using main body buttons When using the CL-200A with Data Management Software CL- S10w (included), measurements can be taken and data transferred to Excel using the main body buttons as well as computer keys. PASS FAIL OK! Excel add-in software included Data Management Software CL-S10w (Standard accessory) Easy, convenient Excel add-in Measurement data from the CL-200A can be transferred directly into Excel. The transferred data can then be managed freely within Excel. Includes LED ranking Color variations, the top topic in the LED industry, can be quantified and a ranking function is also provided. JIS correlated color Correlated color temperature is determined using the equations defined by JIS (Japanese Industrial Standards). Multi-point measurement and user calibration also possible Multi-point measurement management using up to 30 receptor heads is possible. User calibration function enables compensation of measurement values to match a desired standard. Calibration can be performed by two methods: Single-point calibration or RGB calibration. Main specifications of Data Management Software CL-S10w Type Operating environment Compatible instruments Add-in for Excel Excel is required to use this add-in. One of the following environments with Excell installed: Windows XP!+ Excel 2003!(English, Japanese, or Simplified Chinese) Windows 7! + Excel 2010!(English, Japanese, or Simplified Chinese)!For details on system requirements for above versions of Windows and/or Excel,! refer to their respective specifications.!languages in parenthesis ( ) are the OS language. CL-200A, CL-200* * Some functions not usable with CL-200. Application examples For lighting production and adjustment When using various types of light sources in a room or open space, it is sometimes necessary to check the color of the lighting. By using the CL-200A, it is possible to adjust the lighting color so that the food in a restaurant looks delicious. For color-viewing cabinet maintenance A color-viewing cabinet like that shown at left is used in industries such as the printing industry to visually evaluate finished work under controlled conditions. This color-viewing cabinet provides illumination at a specific illuminance and color temperature by using fluorescent lamps, halogen lamps, etc. The CL-200A can be used for the daily maintenance and control of these lamps as well as to indicate when replacement is needed. For evaluating light source Evaluation of the light distribution of LED illumination modules or the illuminance distribution of lighting fixtures can be evaluated. Cross-section A 0 For projector light-source research and color inspection The CL-200A can be used to measure the white balance and uniformity of microprojectors, etc. with internal LED light sources. The ability to connect multiple receptors using LAN cables enables measurement of not only a single point in the center, but up to a maximum of 30 points over the entire projected area. For LED billboard development and maintenance The CL-200A enables quality control of the LED modules for digital signage to be performed easily. If modules with different color tones are used together, the billboard will look mottled, but by measuring the chromaticity and color temperature of modules using the CL-200A and selecting modules based on measured values, billboard uniformity can be achieved. Height (m) 1 2 3 4-3 Illuminance (lx) 300 100 50 30 10 5-2 -1 0 1 2 Horizontal distance (m) 3 9

6000 SYSTEM DIAGRAM Processing by computer PC (commercially available) Printing out data Printer (commercially available) External Power AC Adapter Cap T-A13 Strap Hard Case CL-A10 Data Management Software CL-S10w USB Cable T-A15 (2m) Printer Cable T-A12 (2m) AA Battery (2pcs.)* Case T-A10 * Not included as standard accessory in some areas. Optional receptor head CL-200A** Receptor Head For CRT Measurement Hood CL-A11 CL-200A ** CL-200 receptor head can also be used. Ex.: Multi-point measurement For Multi-Point Measurement / Detached Head Adapter Unit for Receptor Head T-A21 With LAN category-5 cable 1m Adapter Unit for Main Body T-A20 Ex.: Head and body connected via cable LAN (10BASE-T ) category-5 straight cable (commercially available) Multi-point measurement requires use of optional AC adapter. (Standard accessories) (Optional accessories) SPECIFICATIONS For accurate measurements of color temperature, use the CL-200A! Measurement accuracies of CL-200A and photographic color meter When measuring light sources with non-continuous spectrums such as LEDs, etc., accurate illumination color temperature is particularly required. The CL-200A can measure color temperature accurately. CL-200A The CL-200A has sensors that closely match the color-matching functions defined by the CIE (International Commission on Illumination), enabling precise color measurement. The measurement results can be displayed in various color notations such as "Correlated color temperature and Δuv" according to the application. Photographic color meter In order to take more beautiful pictures, it is sometimes necessary to attach filters in front of the camera lens to compensate for the color of the light illuminating the subject. A photographic color meter is a meter used to select the appropriate filters, with the sensitivity of its sensors adjusted to match that of the film or digital camera sensor. In addition, because it uses photographic color temperature, which is calculated based mostly on the blue/red balance of the illumination, large errors may occur if it is used to measure light sources with non-continuous spectrums. [Actual measurement data for daylight-color LED bulb] 5045 CL-200A 5011-34 5600 555 Luminance meter class Relative spectral response Cosine response(f2) Receptor Measuring function Other function Measuring range Accuracy Repeatability Temperature drift Humidity drift Response time Digital output Display Operating temperature/ humidity range Storage temperature / humidity range Power source Battery life Dimensions Weight Standard accessories Optional accessories Color temperature and correlated color temperature Conforms to requirements for Class AA of JIS C 1609-1: 2006 "Illuminance meters Part 1: General measuring instruments" * Closely matches CIE Standard Observer curves x (λ), ȳ (λ), and z (λ) Within 6% (fi') of the CIE spectral luminous efficency V (λ) Ev: Within 3% Silicon photocell Tristimulus values: XYZ Chromaticity: Evxy; Evu'v'; Ev, Dominant wavelength, Excitation purity Correlated color temperature: EvTcpΔuv; Tcp (JIS method; available only with CL-S10w) Color difference: Δ (XYZ), Δ (Evxy), Δ (Evu'v), ΔEvΔu'v' (Target: 1) User calibration function, Data hold function, Multi-point measurement (2 to 30 points) 0.1 to 99,990 lx, 0.01 to 9,999 fcd (Chromaticity: 5 lx, 0.5 fcd or above) in four automatically selected ranges (lx or fcd is switchable) Ev (Linearity): ±2% ±1digit of displayed value xy: ±0.002 (800 lx, Standard illuminant A measured) Ev: 0.5% ±1digit (2σ) (800 lx, Standard illuminant A measured) xy: ±0.0005 Ev: ±3% ±1digit of displayed value, xy: ±0.003 (Based on Konica Minolta's standard measurement conditions) Ev: ±3% ±1digit of displayed value, xy : ±0.003 (Based on Konica Minolta's standard measurement conditions) 0.5 sec. (continuous measurement) USB 4-significant-digit LCD with back-light illumination -10 to 40ºC, relative humidity 85% or less (at 35ºC) with no condensation -20 to 55ºC, relative humidity 85% or less (at 35ºC) with no condensation 2 AA-size batteries / AC adapter (optional) 72 hours or longer (When alkaline batteries are used) in continuous measurement 69X174X35mm (2-6/16X6-14/16X1-7/13 in.) 215g (7.6 oz.) not including batteries Case T-A10, Cap T-A13, Strap, AA Batteries(2)*, Data Management Software CL-S10w, USB Cable T-A15 *Not included as standard accessory in some areas. Receptor Head, Adaptor Unit for Main Body T-A20, Adapter Unit for Receptor Head T-A21, AC Adapter AC-A308 (For 1 to 10 receptor heads), AC Adapter AC-A311 (For 1 to 30 receptor heads), Printer Cable T-A12, Hood CL-A11, Hard Case CL-A10 *For information on luminance meter performance, see p.3. DIMENSIONS (Unit: mm) With receptor head attached to main body Center of Reference plane receptor window 35 ø25 Tripod 7.5 socket 56.3 18 13 With Adapter Unit attached to receptor head 35 7.5 (56.3) (46.3) 69 30 25 30 (71.8) 174 50 ø45.2 ø45.2 ø4.5 hole 27.5 Color temperature When an ideal blackbody* is heated, it begins to emit light, and as the temperature increases the color of the emitted light changes from red to yellow to white. Since the color of the emitted light is determined by the temperature of the blackbody, the color of the light emitted by the blackbody can be expressed as the absolute temperature of the blackbody (in Kelvin). This color notation scale is called "color temperature". For example, a 7000K color would be the color of the light emitted by a blackbody heated to 7000K. Figure 1 shows the color of light emitted by a blackbody at various temperatures plotted on an xy chromaticity diagram. This curve is called the "blackbody locus"; "color temperature" expresses a color on this blackbody locus. Correlated color temperature Since the color of white light emitted by illumination equipment and displays is generally close to the blackbody locus, the color of such light sources is normally expressed using "color temperature". However, the color of such light sources is not directly on the blackbody locus. Because of this, a way to enable similar color expression for colors within a larger region close to the blackbody locus was devised. This is called "correlated color temperature", and the larger region is shown by the isotherms on the xy chromaticity diagram in Figure 2. To accurately express the correlated color temperature of a lightsource color, it is necessary to state not only the correlated color temperature but the difference from the blackbody locus, normally in terms of Δuv. *Blackbody An ideal radiator. A body which completely absorbs all incident electromagnetic radiation. Although a perfect blackbody does not actually exist, coal is a familiar object that acts similarly. y 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 510 500 490 520 480 530 540 470 460 450 380 440 550 560 570 3000 2500 3500 * 4000 A 4500 D55 * * B D65 * D75 * * C 10000 580 2000 1500 590 600 610 620 650 680 780 0.10 0.20 0.30 0.40 0.50 0.60 0.70 x Figure 1: Black body locus on xy chromaticity diagram 0.50 0.45 0.40 0.35 0.30 0.25 0.20 50000 0.02uv 20000 30000 0.01uv Figure 2: 15000 0.00uv 13000 0.01uv 10000 0.02uv 9000 8000 7000 5000 4500 4000 0.25 0.30 0.35 0.40 0.45 0.50 0.55 3500 Closeup of black body locus on xy chromaticity diagram showing correlated color temperature region 3000 2500 10

CHROMA METER CS-100A A compact, lightweight, battery-powered instrument with a 1 measurement angle for high-accuracy non-contact measurements of the luminance and chromaticity of light sources and reflective subjects Viewfinder Image EASY-TO-READ DISPLAY Measuring area (1 ) Field of view (9 ) Measured luminance (cd/m 2 or fl) External display Measured value Measurement mode MAIN FEATURES Compact and lightweight Measurements of subjects at a distance SLR (single-lens-reflex) viewing system and flare-free optical system provide accurate measurements of subjects at a distance with virtually no influence from light outside the measurement area MAIN APPLICATIONS Light-Source Measurements Luminance and chromaticity of small light sources such as LEDs, miniature neon lamps, etc. Luminance and chromaticity of general light sources such as tungsten lamps, fluorescent lamps, etc. Luminance and chromaticity of traffic signals, airport guidance lights, emergency exit signs, etc. Reflective-Subject Measurements Color measurements of subjects which cannot be measured by contact methods, such as distant building walls, justpainted surfaces, subjects with complicated shapes, or subjects which should not be touched for sanitary reasons. Display Measurements Luminance and chromaticity of color TVs and CRTs Luminance measurements of monochrome TVs and SRTs Luminance and chromaticity of projection TVs and video projectors. Measurements of small subjects 1 measurement angle allows measurements of subjects as small as ø14.4mm (at a subject distance of 1014mm); by using optional Close-Up Lenses, subjects as small as ø1.3mm can be measured. Color difference can also be measured Calibration to a user-selected reference is also possible Luminance units of cd/m 2 selected or fl can be 11

SPECIFICATIONS Model Chroma Meter CS-100A Type SLR spot colorimeter for measuring light-source and surface luminance and chromaticity Measuring angle 1 Optical system 85mm f/2.8 lens; SLR viewing system; flare factor less than 1.5% Angle of view 9 with 1 measurement area indication Focusing distance 1014mm (40 in.) to infinity Receptors 3 silicon photocells filtered to detect primary stimulus values for red, green and blue light Spectral response Closely matches CIE 1931 Standard Observer curves (x 2,ȳ, and z ) Response time FAST: Sampling time: 0.1s, Time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, Time to display: 1.4 to 1.6s Luminance units cd/m 2 or fl (switchable) Measuring range FAST: 0.01 to 299,000cd/m 2 (0.01 to 87,530fL); SLOW: 0.01 to 49,900cd/m 2 (0.01 to 14,500fL) Accuracy Luminance (Y): ±2% of reading ±1 digit Chromaticity (x,y): ±0.004 (Illuminant A measured at ambient temperature of 18 to 28 C/64 to 82 F) Repeatability Target value Measurement modes Display Data communication External control Power source Operating temperature /humidity range Storage temperature/humidity range Dimensions Weight Standard accessories SYSTEM DIAGRAM Close-Up Lenses No. 153 No. 135 No. 122 No. 110 PC Connecting Cable LS-A12 DIMENSIONS 78.7 Luminance (Y): ±0.2% of reading ±1 digit Chromaticity (x,y) : FAST: Y 100cd/m 2 or above: ±0.001; 48.1 to 99.9cd/m 2 : ±0.002; below 48.1cd/m 2 : below measurement range SLOW: Y 25.0cd/m 2 or above: ±0.001; 12.0 to 24.9cd/m 2 : ±0.002; below 12.0cd/m 2 : below measurement range (Measurement subject: Illuminant A) 1; set by measurement or numerical input Absolute color: Yxy; color difference: (Yxy) External: LCD; 3 values (Y, x, and y) of 3 digits each with additional indications Viewfinder: 3-digit LCD (showing luminance value Y) with LED backlight RS-232C; baud rate: 4800bps Measurement process can be started by external device connected to data output terminal One 9V battery; power can also be supplied via data output terminal 0 to 40 C, relative humidity 85% or less (at 35 C) with no condensation -20 to 55 C, relative humidity 85% or less (at 35 C) with no condensation 79x208x154mm (3-1/8x8-3/16x6-1/16 in.) 890g (2 lb.) without battery Lens cap; Eyepiece cap; Protective filter, ND eyepiece filter; 9V battery; Chromaticity chart; Case Specifications are subject to change without notice. (Optional Accessories) Data Management Software CS-S10w Professional Angle Finder VN 154.3 40 85.8 28.5 OPTIONAL ACCESSORIES White Calibration Plate (for 45-0 / for d-0) Units:mm Close-Up Lenses Angle Finder VN Close-Up Lenses No.153 No.135 No.122 No.110 (Theoretical values) Minimum measuring area ø8.0mm ø5.2mm ø3.2mm ø1.3mm Angle Finder VN allows the measuring area and measurement display inside the viewfinder to be seen at an angle of 90 to the normal viewfinder optical axis. Angle Finder VN can also be focused and the magnification can be set to 1x or 2x. Data Management Software CS-S10w Professional (Optional accessory) Color space : L v x y, L v u' v', L v T uv, XYZ, dominant wavelength Mode selection : Normal mode, Object color mode, Contrast mode RGB mode, RGB & contrast mode Instrument control : Average measurement, Interval measurement Data management : Reading and saving files, Data management with folders Creating, saving and loading templates (customizable design/layouts for various graphs) Various graph displays Data evaluation : Observer/Illuminant settings Statistics display for each folder Box tolerance setting, Multiple-point measurement, uniformity display, contrast display and polygon tolerance setting for display evaluation Other : Creating reports in customizable screen layouts 208 176 58 49.6 44 Standard plane for distance measurements 57 151 System requirements OS Windows XP Professional 32-bit SP3, 64-bit SP2 Windows Vista Business 32-bit, 64-bit, Windows 7 Professional 32-bit, 64-bit CPU Pentium III 600 MHz equivalent or higher Memory 128 MB min. (256 MB or more recommended) Hard disk 60 MB or more space required for installation Display 1024 X 768, 256 colors or more Other CD-ROM drive, USB port 19 38 16 60.3 Tripod socket Windows are trademarks of Microsoft Corporation in the USA and other countries. Pentium is a trademarks of Intel Corporation in the USA and other countries. 12

SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock. Certificate No : LRQ 0960094/A RegistrationDate : March3, 1995 Certificate No : JQA-E-80027 RegistrationDate : March12, 1997 1996 KONICA MINOLTA SENSING, INC. 9242-4837-45 BBKPPK 23 Printed in Japan