High-speed 1-frame ms scanning confocal microscope with a microlens and Nipkow disks

Similar documents
Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Development of a High-speed Super-resolution Confocal Scanner

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

3D light microscopy techniques

Parallel Mode Confocal System for Wafer Bump Inspection

Confocal principle for macro- and microscopic surface and defect analysis

Confocal microscopy using variable-focal-length microlenses and an optical fiber bundle

(12) United States Patent (10) Patent No.: US 6,525,828 B1

Reflecting optical system to increase signal intensity. in confocal microscopy

Shreyash Tandon M.S. III Year

Confocal Microscopy. Kristin Jensen

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Practical work no. 3: Confocal Live Cell Microscopy

Applications of Optics

Confocal and 2-photon Imaging. October 15, 2010

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Single-shot depth-section imaging through chromatic slit-scan confocal microscopy

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Nontranslational three-dimensional profilometry by chromatic confocal microscopy with dynamically configurable micromirror scanning

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

Light Microscopy. Upon completion of this lecture, the student should be able to:

The DCS-120 Confocal Scanning FLIM System

III III 0 IIOI DID IIO 1101 I II 0II II 100 III IID II DI II

BASICS OF CONFOCAL IMAGING (PART I)

A laser speckle reduction system

Sensitive measurement of partial coherence using a pinhole array

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

(51) Int Cl.: G02B 21/00 ( ) G02B 21/32 ( ) G02B 21/36 ( )

Fast Laser Raman Microscope RAMAN

Aberrations and adaptive optics for biomedical microscopes

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Confocal Microscopy. (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7. November 2017

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Investigation of an optical sensor for small angle detection

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

INTRODUCTION TO MICROSCOPY. Urs Ziegler THE PROBLEM

PHY385H1F Introductory Optics. Practicals Session 7 Studying for Test 2

Twenty-five years of confocal microscopy

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Testing Aspheric Lenses: New Approaches

UltraGraph Optics Design

1.6 Beam Wander vs. Image Jitter

United States Patent (19) Dixon

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

(12) United States Patent (10) Patent No.: US 6,388,807 B1. Knebel et al. (45) Date of Patent: May 14, 2002

Figure 7 Dynamic range expansion of Shack- Hartmann sensor using a spatial-light modulator

Optimal Pupil Design for Confocal Microscopy

Confocal, hyperspectral, spinning disk

Technical Explanation for Displacement Sensors and Measurement Sensors

Spatially Resolved Backscatter Ceilometer

Test procedures Page: 1 of 5

H-PDLC based waveform controllable optical choppers for FDMF microscopy

MEASUREMENT APPLICATION GUIDE OUTER/INNER

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

Circular Dichroism Microscopy Free from Commingling Linear Dichroism via Discretely Modulated Circular Polarization

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging

High resolution extended depth of field microscopy using wavefront coding

TRIANGULATION-BASED light projection is a typical

Fast Laser Raman Microscope RAMAN

Optical Microscopy and Imaging ( Part 2 )

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Design Description Document

Basics of confocal imaging (part I)

Instant super-resolution imaging in live cells and embryos via analog image processing

Parallel Digital Holography Three-Dimensional Image Measurement Technique for Moving Cells

Invitation for a walk through microscopy. Sebastian Schuchmann Jörg Rösner

The spectral colours of nanometers

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Confocal Microscopy and Related Techniques

Maskless Lithography Based on Digital Micro-Mirror Device (DMD) with Double Sided Microlens and Spatial Filter Array

High-speed 3-D measurement with a large field of view based on direct-view confocal microscope with an electrically tunable lens

Programmable array microscopy with a ferroelectric liquid-crystal spatial light modulator

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

Confocal Microscopy Confocal Microscopy Acousto-optic products

DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY ABSTRACT

Non-Descanned FLIM Detection in Multiphoton Microscopes

A Parallel Radial Mirror Energy Analyzer Attachment for the Scanning Electron Microscope

The below identified patent application is available for licensing. Requests for information should be addressed to:

Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Systems Biology. Optical Train, Köhler Illumination

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Microscopic Structures

Experimental demonstration of polarization-assisted transverse and axial optical superresolution

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

APPLICATIONS FOR TELECENTRIC LIGHTING

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Technology Note ZEISS LSM 880 with Airyscan

12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes

Eric B. Burgh University of Wisconsin. 1. Scope

Transcription:

High-speed 1-framems scanning confocal microscope with a microlens and Nipkow disks Takeo Tanaami, Shinya Otsuki, Nobuhiro Tomosada, Yasuhito Kosugi, Mizuho Shimizu, and Hideyuki Ishida We have developed a high-speed confocal laser microscope. A microlens-array disk set in front of a pinhole-array disk improved optical efficiency more than ten times compared with that of conventional Nipkow confocal microscopy. This new microscope achieves a high-speed measurement of 1 framems. We expect that it will be used for measuring biological and industrial active samples. 2002 Optical Society of America OCIS codes: 170.1790, 170.0110, 180.1790, 180.2520, 120.5800. 1. Introduction Recently considerable progress has been made in the development of confocal microscopy, which is attracting increasing attention as a new-generation optical microscope. However, most of today s confocal microscopes are insufficient for high-speed measurements, such as needed for living cells and organs in biology or actuators for industry, which require realtime observation. We have developed an innovative compact high-resolution scanning confocal microscope, using a microlens and Nipkow disks. This microscope has attained a scanning speed as high as 1 framems, which we believe to be the highest ever achieved for a confocal microscope, and 10 1000 times greater than that of conventional confocal microscopes. We report on its construction and features and provide some measurement data. 2. Principles and Features of Confocal Microscopy A conventional optical microscope relies on both a light source, such as a halogen lamp, and an optical detector, such as a camera or human eyes, which are area sources and area detectors. As a result, the sensor receives scattered light from sources other T. Tanaami Takeo.Tanaami@jp.yokogawa.com, S. Otsuki, N. Tomosada, Y. Kosugi, and M. Shimizu are with Yokogawa Electric Corporation, 2-9-32 Nakacho, Musashino-Shi, Tokyo, 180-8750 Japan. H. Ishida is with the Department of Physiology, School of Medicine, Tokai University, Bohseidai, Isehara, Kanagawa, 259-1193 Japan. Received 16 November 2001; revised manuscript received 14 March 2002. 0003-693502224704-05$15.000 2002 Optical Society of America than the point to be measured and also light from the optical axis. This leads to measurement that is out of focus and adversely affects resolution. A confocal microscope with a pinhole in front of the detector functions as a spatial filter that reduces the effect of scattered light. Light from the focal point of the microscope passes through the pinhole, but light from other points on the focal plane does not. Light scattered from dust and similar on the optical axis is focused by the lens on a point somewhere in front of the pinhole, so the resultant image is spread around the pinhole and thus hardly reaches the detector. As a consequence, a confocal system offers a high spatial three-dimensional; 3-D resolution, of 1 m or greater. This confocal microscopy focuses on a single point in 3-D space. However, since it focuses on only one point, it is necessary to scan the beam over the spatial plane to get a complete image. We developed a high-speed scanner for this purpose. 3. Construction and Principle of the Microscope Figure 1 illustrates the construction of our microscope, which consists of two disks. The upper disk is a microlens disk consisting of 20,000 microlenses. When collimated light from a laser illuminates the upper disk, the microlenses focus the light onto the lower disk, which has 20,000 pinholes with the same pattern as that of the microlenses. The light passing through each pinhole is aimed by the objective lens at a spot on the specimen. Reflected light from the specimen passes back on the same path through the objective lens and pinhole, is reflected by a beam splitter, and is focused on the camera through a relay lens. The upper disk containing the microlenses and the lower disk containing the pinholes are 4704 APPLIED OPTICS Vol. 41, No. 22 1 August 2002

Microlens- and Nipkow-disk scanning confocal micro- Fig. 1. scope. physically connected and rotated together by an electrical motor, thus raster scanning the specimen. This two-dimensional scanning of the specimen produces a two-dimensional confocal image on the camera. 4. Features A method to produce images by rotating a disk with pinholes was invented by Paul Nipkow in 1884. In the early development stage of television, the disks were used in both the camera and the monitor. 1 Despite its long history, the Nipkow scanner has retained some special features, as described below, which later scanners do not have. A. High Speed and High Resolution Typical features of different scanning confocal microscopes are shown in Table 1. Many of these microscopes currently are category A, which uses scanning mirrors for both the X and the Y axes. Apart from resonance scanning, most two-axis scanning microscopes take 1 2 s to construct an image. Category B uses slit scanning rather than pinhole scanning, thus attaining relatively high speeds video rate, 30 framess but giving a confocal effect on only one axis. This means a low resolution. Both category A and B microscopes scan the specimen with a single light beam, but the Nipkow scanner, category C in Table 1, illuminates with 1000 beams at once. At the same linear velocity, scanning with 1000 beams is 1000 times brighter and faster than scanners with a single beam. Thus a Nipkow confocal microscope with its pinhole scanning can achieve a confocal effect on both the X and the Y the axes at a high speed of 1 framems, as well as at the video rate. Studies on the response of neurons or heart cells in biology, and microlinear actuator systems in industry, indicate that a scanning speed of 1 framems is desirable. Therefore the high speed of this Nipkow confocal microscope is a major advantage. B. Simple Construction Compared with category A and B microscopes, which have a complex construction for scanning mirrors and optical relay systems and require special actuators such as galvanometer mirrors, a Nipkow confocal microscope is simple and compact and runs on a simple electrical motor. Moreover, it has no optical relays between the pinhole and the objective lens, which is a big advantage in minimizing optical aberrations and distortions. 5. Problems and Solutions A. Optical Signal-to-Noise Ratio Apart from the above advantages, a major disadvantage of conventional Nipkow confocal microscope was a low signal-to-noise ratio. To attain a confocal effect, it is necessary to place the pinholes far enough apart. If the ratio of pinhole diameter to pinhole pitch is 1:10, the aperture ratio of the pinholes is only 1% of the disk area, which means that only 1% of the signal can pass through the pinhole. At the same time, 99% of the light impinging on the disk does not pass through the pinhole but is reflected from the disk surface, resulting in high background illumination or stray light, and reaches the camera as noise. As shown in Fig. 1, we added microlenses in front of the pinholes, which greatly increased the signal and decreased the noise scattered and reflected light from the disk surface, resulting in improving the signal-to-noise ratio significantly. 2 4 With our microlenses we attained an optical ratio defined as the ratio of the light output from the pinholes to the total light impinging on the microlens disk of more than 40%. Compared with a conventional Nipkow microscope with a pinhole disk alone, our microscope with microlenses achieves a light efficiency that is more than tenfold greater. In addition, there is an upper limit on the brightness with white light as a light source to focus the light onto these small pinholes. However, there is no limitation on light power when laser light is used as a light source for this construction. 1 August 2002 Vol. 41, No. 22 APPLIED OPTICS 4705

Fig. 3. System construction. PC, personal computer. B. Nonuniformity of Illumination On a conventional Nipkow disk multiple numbers of pinholes form in a spiral as seen in category A of Table 2, which is an equal angular spiral pattern. This particular placement of pinholes is used because, in fabricating a mask, it is necessary to copy the pattern of radial rows one by one at equal angles. Its disadvantage is that the light intensity at the outer periphery of the disk is lower than that at the inner periphery, since the pitch between pinholes gets wider toward the outer periphery of the disk. To lessen the effect of nonuniform illumination, it is necessary to make the disk large enough for illumination at the outer periphery of the disk to remain sufficient. With a tetragonal pattern as seen in category B of Table 2, there is no imbalance in the light intensity between the inner and the outer peripheries of the disk; however, when the disk is spun, the scanning pitch is not equal, resulting in stripes. As shown in category C of Table 2, we designed a new pattern. The equal-pitch spiral pattern category C is designed with equal pitch along the spiral pattern of the pinholes peripheral pitch and equal track pitch of the spiral pattern radial pitch so as to give constant illumination and also equal scanning pitch regardless of the radius. As a result, there is almost no distortion with this pattern. Category C of Table 2 illustrates the pinhole pattern where more than one thread of pinhole rows are disposed in a spiral shape and where the radial pitch of a track of an imaginary center line connecting the centers of a plurality of pinholes forming the pinhole rows, and the peripheral pitch along the spiral, are equal. This pattern is traced according to the following expressions. As shown in Fig. 2, when the pinhole disk spins one full rotation, the radius becomes larger by m a between the starting point and the ending point of the track of the spiral. Thus radius r is as follows: r r o ma2, (1) where i 0, 1, 2,..., n i.e., in order starting from inside the spiral, ri is the radius of the ith pinhole, ro is the innermost radius, i is the angle of the ith pinhole, m is the number of spirals, and a is the pinhole pitch. The length of arc L is as follows: L 0 0 rd r o ma2 2 2. (2) When Eq. 2 is represented in terms of, mar 2 o r 2 o mal 12. (3) From Eqs. 1 and 3, Eqs. 4 6 are obtained: L ia, (4) r i r o i ma2, (5) mar 2 o r 2 o ima2 12. (6) The pinhole pattern of category C of Table 2 is traced with Eqs. 5 and 6. This pinhole arrangement is formed by a pinhole pitch, a, which is the same in the radial and the peripheral directions as shown in category C of Table 2. 6. System Figure 3 shows our high-speed confocal system. The confocal microscope illuminates the specimen with a laser beam, and the light signal reflected back to the microscope is detected and stored as digital data by the high-speed camera and memory unit. Fig. 2. Diagrams to explain the arrangement of pinholes. 7. Results A. Resolution The measurement result of the optical-axis resolution is shown in Fig. 4. Measurement was made in a 4706 APPLIED OPTICS Vol. 41, No. 22 1 August 2002

Fig. 4. Resolution along the optical axis. reflection mode by use of a mirror as a specimen, which was vibrated continuously by a piezoelement in the direction of the optical axis, recording the light intensity. An objective lens with a numerical aperture of 0.9 and a laser light source with a wavelength of 488 nm were used. As shown in Fig. 4, the FWHM was 0.6 m, which agrees well with the simulation value. B. Signal-to-Noise Ratio of Images There are two types of signal-to-noise ratio for images: camera noise and image intensifier noise. 1. Camera Noise The main noise of a camera is shot noise caused by the intensity of photons and analog-to-digital noise caused by an analog-to-digital transform. We estimate these two types of noise. Figure 5 shows the results. We use a low-noise dc light source noise, 0.4%. The shot noise is N shot 2q Pin B 12, (7) where q is the electric charge 1.6 10 19 Celsius, Pin is the input light power watts, and B is the bandwidth of noise hertz. The experimental result and calculation of shot noise fits well. It shows that the limitation of signal-to-noise ratio of this camera system is shot noise. Fig. 6. Noise estimation of camera and image intensifier. 2. Camera and Image Intensifier Noise Figure 6 shows the results of an entire system that includes a camera and an image intensifier. The parameters of the graph are the gain of image intensifier. This result means that this system has a 7-bit 0.8% signal-to-noise ratio of images if there is enough light to the camera and image intensifier. C. Image Data An example of a high-speed 1-framems continuous measurement of a moving micromachine is shown in Fig. 7. Images of a moving linear encoder were captured a rate of 1 framems. This encoder was part of a linear actuator, which moved 20 mms from the left-hand side to the right-hand side on the images. Our system is capable of continuously capturing 2700 images at the maximum. The result of a biological application is shown in Fig. 8. We achieved observation of changes in intracellular positive calcium ions after electrical stimulation of adult rat ventricular cells, which were loaded by Ca 2 indicator, fluo-3. Fig. 5. Noise estimation of camera. Fig. 7. High-speed confocal image; encoder of linear actuator pitch, 0.17 mm. 1 August 2002 Vol. 41, No. 22 APPLIED OPTICS 4707

Fig. 8. Fluorescent images of ventricular cell from adult rat 1 msframe. To our knowledge, these are the fastest confocal images ever observed. 8. Conclusion By adding microlenses to a Nipkow pinhole-scanning unit, we attained an optical ratio which is defined as ratio of light output from pinholes to the total light impinging on the microlens disk of more than 40%. Using our system, we were able to capture images at 1 framems or a video rate achieving a confocal effect on both the X and the Y planes. This system would be a useful tool for measuring not only industrial but also biological specimens. This research was performed under the management of the Micro-machine Center in the Industrial Science and Technology Frontier Program, Research and Development of Micro-machine Technology, of Ministry of International Trade and Industry supported by the New Energy and Industrial Technology Development Organization. References 1. R. C. Mellors and R. Silver, A microfluorometric scanner for the differential detection of cells, Science 114, 356 361 1951. 2. T. Tanaami, Y. Sugiyama, and K. Mikuriya, High-speed confocal laser microscopy, Yokogawa Tech. Rep. 9, English ed. Yokogawa Electric Corporation, Tokyo, Japan, 1994, pp. 7 10. 3. A. Ichihara, T. Tanaami, K. Isozaki, Y. Sugiyama, Y. Kosugi, K. Mikuriya, M. Abe, and I. Umeda, High-speed confocal fluorescent microscopy using a Nipkow scanner with microlenses for 3-d imaging of single fluorescent molecule in real time, Bioimages 42, 57 62 1996. 4. C. Genka, H. Ishida, K. Ichimori, Y. Hirota, T. Tanaami, and H. Nakazawa, Visualization of biphasic Ca 2 diffusion from cytesol to nucleus in contracting adult rat cardiac myocytes with an ultra-fast confocal imaging system, Cell Calcium 25, 199 208 1999. 4708 APPLIED OPTICS Vol. 41, No. 22 1 August 2002