Haptic Reproduction and Interactive Visualization of a Beating Heart Based on Cardiac Morphology

Similar documents
Current Status and Future of Medical Virtual Reality

Virtual Reality as Human Interface and its application to Medical Ultrasonic diagnosis

5HDO 7LPH 6XUJLFDO 6LPXODWLRQ ZLWK +DSWLF 6HQVDWLRQ DV &ROODERUDWHG :RUNV EHWZHHQ -DSDQ DQG *HUPDQ\

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

Virtual and Augmented Reality techniques embedded and based on a Operative Microscope. Training for Neurosurgery.

Job Description. Commitment: Must be available to work full-time hours, M-F for weeks beginning Summer of 2018.

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Computer Assisted Abdominal

Robotic System Simulation and Modeling Stefan Jörg Robotic and Mechatronic Center

Methods for Haptic Feedback in Teleoperated Robotic Surgery

BodyViz fact sheet. BodyViz 2321 North Loop Drive, Suite 110 Ames, IA x555 www. bodyviz.com

ience e Schoo School of Computer Science Bangor University

A Training Simulator for the Angioplasty Intervention with a Web Portal for the Virtual Environment Searching

SMart wearable Robotic Teleoperated surgery

Wireless In Vivo Communications and Networking

Haptics CS327A

Overview of current developments in haptic APIs

Using Web-Based Computer Graphics to Teach Surgery

Medical Robotics. Part II: SURGICAL ROBOTICS

Haptic presentation of 3D objects in virtual reality for the visually disabled

ITS '14, Nov , Dresden, Germany

Surgical robot simulation with BBZ console

Integrating PhysX and OpenHaptics: Efficient Force Feedback Generation Using Physics Engine and Haptic Devices

Realistic Force Reflection in the Spine Biopsy Simulator

Realistic Force Reflection in a Spine Biopsy Simulator

Distributed Vision System: A Perceptual Information Infrastructure for Robot Navigation

Haptic Feedback in Laparoscopic and Robotic Surgery

Haptic Rendering CPSC / Sonny Chan University of Calgary

Evaluation of Haptic Virtual Fixtures in Psychomotor Skill Development for Robotic Surgical Training

NeuroSim - The Prototype of a Neurosurgical Training Simulator

Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery

A Haptic-enabled Toolkit for Illustration of Procedures in Surgery (TIPS)

Novel machine interface for scaled telesurgery

Evaluation of Visuo-haptic Feedback in a 3D Touch Panel Interface

MIVS Tel:

Tactile Interactions During Robot Assisted Surgical Interventions. Lakmal Seneviratne

R (2) Controlling System Application with hands by identifying movements through Camera

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

INTRODUCING THE VIRTUAL REALITY FLIGHT SIMULATOR FOR SURGEONS

Using Simulation to Design Control Strategies for Robotic No-Scar Surgery

The Virtual Haptic Back (VHB): a Virtual Reality Simulation of the Human Back for Palpatory Diagnostic Training

Stereoscopic Augmented Reality System for Computer Assisted Surgery

Force feedback interfaces & applications

Cancer Detection by means of Mechanical Palpation

Chapter 6: TVA MR and Cardiac Function

Epona Medical simulation products catalog Version 1.0

Control and confidence all around. Philips EP cockpit people focused solutions for heart rhythm care

Automated Detection of Early Lung Cancer and Tuberculosis Based on X- Ray Image Analysis

Comparison of Simulated Ovary Training Over Different Skill Levels

Haptic Rendering and Volumetric Visualization with SenSitus

preface Motivation Figure 1. Reality-virtuality continuum (Milgram & Kishino, 1994) Mixed.Reality Augmented. Virtuality Real...

VR for Microsurgery. Design Document. Team: May1702 Client: Dr. Ben-Shlomo Advisor: Dr. Keren Website:

Haptics in Military Applications. Lauri Immonen

Small Occupancy Robotic Mechanisms for Endoscopic Surgery

A NEW APPROACH FOR ONLINE TRAINING ASSESSMENT FOR BONE MARROW HARVEST WHEN PATIENTS HAVE BONES DETERIORATED BY DISEASE

Evaluation of Five-finger Haptic Communication with Network Delay

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

HUMAN Robot Cooperation Techniques in Surgery

CS277 - Experimental Haptics Lecture 2. Haptic Rendering

Computer Haptics and Applications

Robot assisted craniofacial surgery: first clinical evaluation

A surgical simulator for training surgeons in a few tasks related to minimally invasive surgery

Accuracy evaluation of an image overlay in an instrument guidance system for laparoscopic liver surgery

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

OPHTHALMIC SURGICAL MODELS

DESIGN OF HYBRID TISSUE MODEL IN VIRTUAL TISSUE CUTTING

Image Interpretation System for Informed Consent to Patients by Use of a Skeletal Tracking

Haptic Technology- Comprehensive Review Study with its Applications

Development of a Finger Mounted Type Haptic Device Using a Plane Approximated to Tangent Plane

Digital Reality TM changes everything

Using Simple Force Feedback Mechanisms as Haptic Visualization Tools.

4/23/16. Virtual Reality. Virtual reality. Virtual reality is a hot topic today. Virtual reality

2 Outline of Ultra-Realistic Communication Research

Virtual and Augmented Reality Applications

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

Printed in Japan E318

COMPUTED TOMOGRAPHY 1

Gaussian Naive Bayes for Online Training Assessment in Virtual Reality-Based Simulators

Using virtual reality for medical diagnosis, training and education

Biomimetic Design of Actuators, Sensors and Robots

Incorporating novel image processing methods in a hospital-wide PACS

Virtual Environments. CSCI 420 Computer Graphics Lecture 25. History of Virtual Reality Flight Simulators Immersion, Interaction, Real-time Haptics

Toward an Augmented Reality System for Violin Learning Support

Computer Assisted Medical Interventions

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

Fracture fixation providing absolute or relative stability, as required by the personality of the fracture, the patient, and the injury.

Virtual Environments. Virtual Reality. History of Virtual Reality. Virtual Reality. Cinerama. Cinerama

Design and Controll of Haptic Glove with McKibben Pneumatic Muscle

Excellent Performance; Ease of Use

1/22/13. Virtual Environments. Virtual Reality. History of Virtual Reality. Virtual Reality. Cinerama. Cinerama

RENDERING MEDICAL INTERVENTIONS VIRTUAL AND ROBOT

Image Guided Robotic Assisted Surgical Training System using LabVIEW and CompactRIO

Phantom-Based Haptic Interaction

Arterial pulse waves measured with EMFi and PPG sensors and comparison of the pulse waveform spectral and decomposition analysis in healthy subjects

Geometric modelling of the temporal bone for cochlea implant simulation

Virtual Sculpting and Multi-axis Polyhedral Machining Planning Methodology with 5-DOF Haptic Interface

Development Scheme of JewelSense: Haptic-based Sculpting Tool for Jewelry Design

Differences in Fitts Law Task Performance Based on Environment Scaling

EnSite Precision Cardiac Mapping System ACCURACY OF THE ENSITE NAVX NAVIGATION AND VISUALIZATION TECHNOLOGY, SENSOR ENABLED

Development of A Finger Mounted Type Haptic Device Using A Plane Approximated to Tangent Plane

Transcription:

MEDINFO 2001 V. Patel et al. (Eds) Amsterdam: IOS Press 2001 IMIA. All rights reserved Haptic Reproduction and Interactive Visualization of a Beating Heart Based on Cardiac Morphology Megumi Nakao a, Masaru Komori b, Hiroshi Oyama b, Tetsuya Matsuda a Genichi Sakaguchi c, Masashi Komeda c, Takashi Takahashi b a Graduate School of Informatics, Kyoto University, Kyoto, Japan b Department of Medical Informatics, Kyoto University Hospital, Kyoto, Japan c Cardiovascular Surgery, Kyoto University Hospital, Kyoto, Japan Abstract A goal of this work is proposal and construction of simulation methods of haptic reproduction and interactive visualization of a beating heart in cardiovascular surgical training and education. The data for the beating heart model was obtained from ECG-gated 3D MRI of a normal volunteer. The elastic information was assumed as a uniform value with clinically experienced elasticity. Using a real-time 3D graphics and a haptic device, a simulation environment of the beating heart was designed and implemented. After the construction, some cardiovascular surgeons evaluated the implemented system. Its visualization and haptic expression were scored excellent, but some details in haptic interface were remained to be improved. Finally, for more realistic cardiovascular surgical simulation, future development of the method is discussed. Keywords: Cardiac Simulation, Haptics, Interactive Visualization, Medical Education, Surgical Training Introduction In the medical field, various surgical procedures have been created and developed. Especially in recent days, minimally invasive surgery and robotic surgery also appeared. As a result of rapid advance in medical technologies, surgical education and training as a subset of graduate medical education has drawn increasing interest. To satisfy above interest and requirements, virtual reality techniques have been focused. [1] The visual and interactive environment using VR technique has proven to be useful in understanding complex 3D structures and for training. [2][3] The manipulations such as navigation, palpation and surgical procedures are performed through haptic interfaces. [4][5] If constructed system generates realistic force like that of real tissues to the users, it also contributes to medical education as surgical simulators. [6] Haptic information during cardiovascular surgeries is very important for diagnosis and design of surgical strategies. As to surgical procedures in a surgery of cardiac tamponade, for example, it should be required that a surgeon inserts a thin pipe between myocardium and pericardium under the condition of the heart beating. This operation is a difficult example for surgeons, because delicate procedures are required to treat the heart directly. For these requirements, if a novel simulation environment to reproduce tactile sense of beating heart is constructed, safer operation can be realized by repeating rehearsal of the surgery. In addition, a system that simulates the motion of cardiac muscles and valves with haptics allows medical students and surgeons to learn palpation objectively. On the other hand, it has been difficult to measure morphological information of entire cardiac cycle, because the heart is an active organ and has dynamic motion. Due to the complexity of cardiac dynamics including various variables such as myocardial motion, cardiac excitation, blood pressure and so on, it was difficult to describe and simulate its function faithfully. In addition, study of cardiac dynamics requires analysis of multi-dimensional variables and complex parameters. Therefore, in the field of computer-assisted simulation, few studies have ever tried to describe and simulate tactile sense of beating heart based on in vivo datasets. [7] On the contrary, this paper gives a cardiac force model and simulation methods for haptic reproduction and interactive visualization of beating heart based on cardiac morphology. And using a real-time 3D graphics and a haptic device, a simulation system of the beating heart is designed and implemented. Materials and Methods As heart dataset, time series of volumes of entire heart cycle are successfully acquired from a normal volunteer from ECG-gated 3D MRI. One research goal of this study is the proposal of dynamic force description of heartbeat for realistic tactile reproduction, from time series heart 924

morphology. In addition, based on proposed force description, a visible and palpable simulation system is constructed for the purpose of interactive analysis, medical education and surgical training. The characteristics and functions of the system are summarized below. Four-dimensional (spatial and temporal) heart atlas Haptic reproduction based on cardiac morphology Interactive visualization and analysis A constructed graphic and haptic simulation of a beating heart is named "ActiveHeart System. In this section, the methods of data preparation, data registration, force model, visualization and system implementation are described. Heart datasets and Registration The heart datasets are 15 time series chest formed volumetric data of a normal volunteer from ECG gated MRI technique, and one volume consists of 256*256*64 voxel. The resolution of the data is 1mm for horizontal direction and 3mm for vertical direction and 50 msec for time. One slice image is shown in the figure1. Force Models The main subject of this study is how to reproduce realistic tactile sense of a heartbeat from time series heart dataset. Since conventional computer-assisted simulation dealt with static organs like the liver or leg, it was important to consider how to reproduce passive stress only against the movement of the user's hand interactively. [8][9] In this study, however, another description must be given for tactile reproduction because the in-vivo beating heart is an active organ. In this paper, cardiac dynamics is described using two step force model: one model is static for passive stress by pushing cardiac muscle, and another model is dynamic for active pressure by cardiac autonomous diastole. In other words, static model simulates stiffness of myocardium of a static heart, and dynamic model simulates active force feedback of a beating heart. Static Model The registration method makes the collision detection algorithm more precise and attains realistic force feedback time rate. Figure3 illustrates static force description. Figure1. One slice MRI image After semi-automatic region extraction using a regiongrowing technique from surrounded tissues, time series heart formed volumes were acquired. Figure2 is the slice image after segmentation. Figure2. After region extraction To describe cardiac dynamics from volumetric heart data, a volume registration method using space digitizing approach was taken. In this case, 1.0mm*1.0mm*3.0.mm space was applied to one voxel based on space resolution of heart data. Then, considering the spatial size of heart data, a definite space in the real world was assigned to one volume. As a result of this registration method, 25.6cm*25.6cm*19.2cm area was defined as a virtual workspace to reproduce a fourdimensional heart object. Figure3. Static Force Model [STEP1] A position of user's hand (user point) in the real space that means a position of stylus point of the haptic device is mapped onto absolute coordinate of the workspace. [STEP2] If the user point is mapped on the part of heart data, this situation means "contact." Like this, accurate and simple collision detection can be realized, because it doesn't need to calculate a distance between user's hand and the object. [STEP3] After collision detection, if a user moves his or her hand into the heart object, passive stress is generated in proportion to the distance from the contact point. As for force calculation, elastic coefficient was assumed as a uniform value with clinically experienced elasticity. Dynamic Model Constructed virtual space using the space digitizing method can be applied to active pressure description. Figure4 illustrates active force description for dynamic myocardial motion. 925

Figure4. Dynamic Force Model [STEP1] It supposes that a user is touching the heart, that is, a user point is on the surface of virtual heart object. [STEP2] In this case, it is not a user point but a heart object that moves in this virtual space. If heart surface moves to the user point, the user point is temporally inside the beating heart object. [STEP3] Then, by the same way as static model, active pressure is generated in proportion to the distance from the user point to the scanned surface point. System Overview The ActiveHeart system was constructed using a PHANToM haptic device, Windows NT PC, graphic user interface and rendering hardware. As shown in Figure6, the ActiveHeart system has a graphic part and a haptic part. In the haptic part, movement of the user's hand is transmitted though the PHANToM haptic device. And this system calculates force by the user's position information and returns force value to PHANToM. In the graphic part, the user's operative information, such as rotation, is transmitted to the rendering hardware. On the rendering board, real time rendering is done and the time series rendered images are displayed as heart animation through the graphic user interface. Based on the force description using two-step model, active force is generated at cardiac diastole. However, there is still one definite problem, that is, time resolution of generated time series force. If generated 15-frames/second dynamic forces were presented, a user feels it is an awkward force expression. To solve this problem, the time series force value was complemented linearly, and generated 1000- frames/second dynamic forces. [10] Figure5 shows one example of time series force values of the left ventricle after smoothing. Figure6. The overview of the ActiveHeart System Results Figure5. Time series of force value of the left ventricle Visualization There was still another subject, that is, how to generate real-time and interactive images or animations of a beating heart. To achieve interactive functions such as rotation, scale change and cutting, time series volume dataset need large calculation time for volume rendering. This work solved these problems and achieved refresh time rate for real-time rendering, using rendering hardware, parallel computing and synchronized process mechanism. And various interactive operations came to be realized by providing graphical user interface. Figure7 shows a graphical user interface of the implemented simulation system. Figure 8 shows the results of haptic reproduction and interactive visualization of a beating heart. Upper images illustrate haptic expression of the left ventricle. User point is described as a sphere image and line images show generated dynamic force vector. Lower images illustrate real time visualization of inner organs and blood flow. Some cardiovascular surgeons evaluated the system. By the surgeons, generated tactile sense is the same as that of experienced elasticity in cardiac palpation. Consequently, both beating expression and visualization scored excellent, but some details in haptic expression were remained to be improved. 926

Figure 7. Graphical user interface Figure 8. Haptic reproduction and interactive visualization of a beating heart Discussion For visible and palpable educational system including various heart diseases, we are now developing the interface and adding heart pressure to this system. And, for more realistic cardiovascular surgical simulation, the system should support other functions like stereoscopy, multiple haptic interfaces, and adding other clinical parameters. In the near future, however, we believe this system will be available for medical education for palpation and basic surgical training in procedures such as intra-cardiac catheter ablation. Conclusion This work provided dynamic force description about active force and passive stress based on cardiac morphology. Based on above two-step methodology, force feedback algorithm was described and implemented as ActiveHeart system using rendering hardware and haptic interface. System processes by parallel computing were also developed to optimise and synchronize graphics and haptics. Consequently, constructed simulation environment performed realistic haptic reproduction and real time visualization of a beating heart. References [1] T. Schiemann, U. Tiede, K. H. Hohne, The Visible Human within the VOXEL-MAN Framework, Proceedings, The Visible Human Project Conference, 1996 [2] Paul J.Gorman, Andreas H.Meier, M.Krummel; Computer-Assisted Training and Learning in Surgery, Computer Aided Surgery vol.5, p.120-127, 2000 [3] K. H. Hohne, B. Pflesser, A. Pommert et al; A new representation of knowledge concerning human anatomy and function, Nature medicine volume 1 number 6, June 1995 [4] Karl D. Reinig, Charles G. Rush, Helen L. Pelster; Real-Time Visually and Haptically Accurate Surgical 927

[5] Simulation, MMVR4, 1996 [6] J. Berkley, S. Weghorst, H. Gladstone, G. Gaugi, D. Berg, M. Ganter, Banded Matrix Approach to Finite Element Modelling for Soft Tissue Simulation, Virtual Reality, 1999 [7] M.Suga, T.Matsuda, J.Okamoto, O.Takizawa, O.Oshiro, K.Minato, S.Tsutsumi, I.Nagata, N.Sakai, T.Takahashi; "Sensible Human Projects: Haptic Mondeling and Surgical Simulation Based on Measurements of Practical Patients with MR Elastography -Measurement of Elastic Modulus", Medicine Meets Virtual Reality2000, 2000 [8] Wei-te Lin and Richard A.Robb; Simulation and interactive multi-dimensional visualization of cardiac dynamics using a patient-specific physic-based model, Proceedings of Computer Assisted Radiology and Surgery 2000, p35-40 [9] D. Ruspini, Adding Motion to Constraint Based Haptic Rendering Systems: Issues & Solutions, Proceedings, Second PHANToM Users Group Workshop, 1997 [10]R. Shaw, Nearest neighbour approach to Haptic Collision Detection, Proceedings, Third PHANToM Users Group Workshop, 1998 [11]R. Yoshida, A. Kameyama, M. Komori, T. Matsuda, T. Takahashi et al; Quantitative analysis of a network specific factoring medical haptic environment by a psychological experiment, The 19 th Joint Conference on Medical Informatics, 1999 Address for correspondence Megumi Nakao, Office: Medical Informatics, Kyoto University Hospital Address: Shougoin Kawara-chou, Sakyou, Kyoto, Japan Phone: +81-75-751-3165, Fax: +81-75-751-3077 E-mail: meg@kuhp.kyoto-u.ac.jp 928