Photon Diagnostics. FLASH User Workshop 08.

Similar documents
TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

On-line spectrometer for FEL radiation at

Photon Diagnostics for the VUV-FEL

Infrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation

VUV-FEL User workshop, August 23-24, 2004

FLASH performance after the upgrade. Josef Feldhaus

membrane sample EUV characterization

FLASH: Status and upgrade

Demonstration of exponential growth and saturation at VUV wavelengths at the TESLA Test Facility Free-Electron Laser. P. Castro for the TTF-FEL team

Outline of the proposed JLAMP VUV/soft X-ray FEL and the challenges for the photon beamlines and optics

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation

Performance of the SASE3 monochromator equipped with a provisional short grating. Variable line spacing grating specifications

Focusing X-ray beams below 50 nm using bent multilayers. O. Hignette Optics group. European Synchrotron Radiation Facility (FRANCE) Outline

BEAM DIAGNOSTICS AT THE VUV-FEL FACILITY

Wir schaffen Wissen heute für morgen

NIST EUVL Metrology Programs

Instructions for the Experiment

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Fiber Lasers for EUV Lithography

FLASH 2. FEL seminar. Charge: 0.5 nc. Juliane Rönsch-Schulenburg Overview of FLASH 2 Hamburg,

THz Pump Beam for LCLS. Henrik Loos. LCLS Hard X-Ray Upgrade Workshop July 29-31, 2009

Status of the Electron Beam Transverse Diagnostics with Optical Diffraction Radiation at FLASH

Investigations towards an optical transmission line for longitudinal phase space measurements at PITZ

Abstract. Technological advances are exploited by a Thomson scattering diagnostic on the Pegasus Toroidal Experiment

J-KAREN-P Session 1, 10:00 10:

X-Ray Transport, Diagnostic, & Commissioning Plans. LCLS Diagnostics and Commissioning Workshop

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

CHARA AO Calibration Process

The University of Toledo R. Ellingson and M. Heben

Progress of the TEO experiment at FLASH

FLASH at DESY. FLASH. Free-Electron Laser in Hamburg. The first soft X-ray FEL operating two undulator beamlines simultaneously

FLASH Upgrade. Decrease wavelength and/or increase brilliance

Commissioning of Thomson Scattering on the Pegasus Toroidal Experiment

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

LCLS-II-HE Instrumentation

combustion diagnostics

High Power and Energy Femtosecond Lasers

Introduction to the operating principles of the HyperFine spectrometer

High harmonics generation: Spatial characterisation and applications

FLASH II. FLASH II: a second undulator line and future test bed for FEL development.

EUV Interference Lithography in NewSUBARU

GRENOUILLE.

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Observational Astronomy

Light at the FLASH FIR beamline second coming. DESY.DE

A Possible Design of Large Angle Beamstrahlung Detector for CESR

Fast Bunch Profile Monitoring with THz Spectroscopy of Coherent Radiation at FLASH.

TriVista. Universal Raman Solution

Improving efficiency of CO 2

LUCX - THZ PROGRAM: OVERVIEW AND PROSPECTS

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

Contouring aspheric surfaces using two-wavelength phase-shifting interferometry

Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography

Nonintercepting Diagnostics for Transverse Beam Properties: from Rings to ERLs

Detection and application of Doppler and motional Stark features in the DNB emission spectrum in the high magnetic field of the Alcator C-Mod tokamak

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Electro-Optic Longitudinal Bunch Profile Measurements at FLASH: Experiment, Simulation, and Validation

Advanced Beam Instrumentation and Diagnostics for FELs

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Optics for next generation light sources

Commissioning the Echo-Seeding Experiment ECHO-7 at NLCTA

Testing Aspheric Lenses: New Approaches

12/08/2003 H. Schlarb, DESY, Hamburg

X-ray Transport Optics and Diagnostics Commissioning Report

Historical. McPherson 15 Mount

PhysicsAndMathsTutor.com 1

ΘΘIntegrating closedloop adaptive optics into a femtosecond laser chain

Hartmann wavefront sensing Beamline alignment

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

arxiv:physics/ v1 [physics.acc-ph] 18 Jul 2003

pcvd diamond beam position monitors for PETRA III

In-focus monochromator: theory and experiment of a new grazing incidence mounting

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation

OPAL. SpotOptics. AUTOMATED WAVEFRONT SENSOR Single and double pass O P A L

Holography as a tool for advanced learning of optics and photonics

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1

Compensation of hologram distortion by controlling defocus component in reference beam wavefront for angle multiplexed holograms

Adaptive Optics for LIGO

Option G 4:Diffraction

Sub-300 fs, 0.5 mj pulse at 1kHz from Ho:YLF amplifier and Kagome pulse compression

Use of Computer Generated Holograms for Testing Aspheric Optics

Vacuum Ultra Violet Monochromator

R&D Toward Brighter X-ray FELs

Installation of the Optical Replica Synthesizer (ORS) at FLASH

Physics 3340 Spring Fourier Optics

High-Energy 6.2-fs Pulses for Attosecond Pulse Generation

Bridging the Gap Between Tools & Applications

SpotOptics. The software people for optics OPAL O P A L

Far field intensity distributions of an OMEGA laser beam were measured with

SUPPLEMENTARY INFORMATION

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

Multi-pass Slab CO 2 Amplifiers for Application in EUV Lithography

J. C. Wyant Fall, 2012 Optics Optical Testing and Testing Instrumentation

Transcription:

Photon Diagnostics FLASH User Workshop 08 Kai.Tiedtke@desy.de

Outline What kind of diagnostic tools do user need to make efficient use of FLASH? intensity (New GMD) beam position intensity profile on the sample / focus size (wave front sensor) temporal radiation pulse profile and coherence (autocorrelator) spectral distribution (VLS, photoelectron spectrometer, etc. ) Objectives of this talk is to describe the recent developments, design concepts and prototypes

Photon beam diagnostics at FLASH Experimental hall Beam distribution area Gas attenuator Old diagnostics tools Intensity and beam position Spectral distribution Tunnel section Detector and aperture units 1&2)

Tunnel section Detector Unit F2 (Apertures, Detectors, mirror) Intensity + beam profil + diffraction (coherence) +deflection into spectrometer Detector Unit F1 (Apertures, Detectors) Intensity + beam profil + double slit (coherence) FEL Elektronen Beamline for the synchrotron radiation of the dipol magnet grading spectrometer with intensified CCD Single shot spectrum

BDA Beam distribution in the optical enclosure of the experimental hall beam shutter fast shutter mirror chamber 1 beam switching mirrors beam intensity and position monitor gas attenuator

Gas Monitor Detector: From experimental setup to reliable tools Photon Beam Intensity simple principle online absolute, calibrated pulse resolved nondestructive Photon Beam position Single photoionisation: N = N ph x n x σ x l N = number of electrons or ions N ph = number of photons n = target density σ = photoionisation cross section l = length of interaction volume In collaboration with PTB in Berlin and IOFFE institute St. Petersburg

Beam position monitor left electrode Ion current Moved the device by 0.5 mm right electrode I(L) / I(R) The BPM information can be used for a machine feedback in order to stabilise the beam In collaboration with PTB in Berlin and IOFFE institute St. Petersburg

Layout at FLASH Undulator GMD x GMD y Attenuator GMD x GMD y Mirrors Experiment GMD Intensity directly behind the undulator for operators Intensity after attenuator for experiments Intensity at / right behind experiment (mirror transmission) Position and pointing vector All values are stored in the DAQ Experiments often need additionally analogue signal The GMD is a proven tool and the service most asked-for by the experiments The detector Software architecture In collaboration with PTB in Berlin and IOFFE institute St. Petersburg

NEW GMD 2nd generation GMD just under commissioning Enhanced sensitivity (open electron multiplier) Robust and reliable hardware design Easy to handle like commercial detector Can be used to determine the intensity in front or behind user experiments 2nd gen. NewGMD In collaboration with PTB in Berlin and IOFFE institute St. Petersburg

Spectral distribution Radiation pulse length τ rad : τ rad 2π 1/2 /(Δω) FWHM M2: VLS grating Collaboration with:r. Reininger (SAS), F. Quinn (CLRC) et al.

Online spectrometer for single pulses Collaboration with: BESSY, R. Reininger (SAS), F. Quinn (CLRC) et al.

Alternative concept: i- and e- TOF spectrometer One can use the Ion and Electron TOF data to pinpoint the photon energies. Electron TOF spectrum for O 2, taken in July 2007 at FLASH by Wellhoefer et al. at a 13.9 nm photon wavelength. Ion Photoionization Ratio Spectrum for He from Bartlett et al., Physical Review A 46, 5574 (1992) Collaboration with University of Hamburg, PTB

Online determination of the spectral distribution using i- and e- TOF spectrometer 2 + Peak Area (A2) 1 + Peak Area (A1) signal time A2 A1 ratio ev I-TOF Photoionization Spectrum at Some Photon Energy Double-to-Single Photoionization Cross-Section Ratio Collaboration with University of Hamburg, PTB

Online determination of the spectral distribution using i- and e- TOF spectrometer High intensity Medium intensity Low intensity Electron TOF spectra for O2, taken in July 2007 at FLASH by Wellhoefer et al. at a 13.9 nm photon wavelength. E-TOF spectra peaks shift with different FEL pulse intensities. Collaboration with University of Hamburg, PTB

Online determination of the spectral distribution using i- and e- TOF spectrometer e-tofs I-TOF Gas Inlet The test chamber for the Online Spectrometer development. First tests in Oct. 2008 Collaboration with University of Hamburg, PTB

COMPACT SPECTROMETER FOR FLASH Luca Poletto and Fabio Frasetto, CNR-INFM, Padova (Italy) The main requirements are Spectral range 1-40 nm Spectral resolution better than 0.25% Maximum acceptance angle 10 mrad High dynamic range (up to 104) Compact design Optical design The spectrometer consists of an entrance slit, a spherical grating with variableline-spacing (VLS) with flat focal plane and a detector. The entrance slit is placed at a distance of 1-3 m from the FEL focal point on the experimental chamber. Collaboration with CNR-INFM, Padova (Italy)

Temporal coherence and pulse duration Two Autocorrelator set-ups The FEL radiation is split and directed under grazing incidence over a set of fixed and a set of position-variable mirrors, respectively, before being recombined. R. Mitzner, H. Zacharias et al. 2008

Temporal coherence and pulse duration First commissioning Temporal coherence Pulse duration with nonlinear autocorrelation Fringe visibility as a function of path difference between two beams Nonresonant two-photon double ionization of He R. Mitzner, H. Zacharias et al. 2008

Lateral intensity- Focus determination Saturation of ion signals due to vanishing targets: Determination of FEL beam size and waist Ne + hν = 38 ev Beamline BL2 @ FLASH focus diameter: (26 ± 3) µm focus position N + ( N ph ) 1 e σ = N N ph A fit cross section σ is known photon number N ph is measured beam cross section A is derived A.A. Sorokin et al., Appl. Phys. Lett. 89, 221114 (2006)

Lateral intensity Focus determination Method based on ablation of PMMA Single-Shot Determination (but post mortem) FEL beam imprint (AFM measurement) F [a.u.] y [μm] -20-10 0 10 20 30 40 50 30 30 X crossection Y crossection 25 20 15 10 threshold level 25 20 15 10 Reconstructed beam profile 5 5 0 0-10 0 10 20 30 40 50 60 x [μm] Chalupsky et al., Opt. Express, 15, 6036 (2007)

Lateral intensity Focus determination/optimisation More convenient approach: Wavefront sensor Wave front sensor soft- and hardware by Imagine Optic CCD: field of view = 19.5 x 19.5 mm 1340 x 1300 pixels Hartmann plate: 51 x 51 quadratic holes tilted by 25 to prevent interference of adjacent holes camera image camera image zoom The actual beam is compared to a perfect spherical wave Courtesy Pascal Mercère, SOLEIL

File: 08081016.himg Before adjusting ellipsoidal mirror of BL2 defocus 100mm radius 164.9µm defocus 50mm radius 87.8µm defocus 0mm radius 42.3µm Rotation: 0 Yaw: 0 PV: 110nm rms: 22nm @ 27 nm λ/1 defocus -50mm radius 88.9µm defocus -100mm radius 166.0µm

File: 08081060.himg After adjustment of BL2 defocus 100mm radius 165µm defocus 50mm radius 84.1µm Rotation: 45000 Yaw: -0.01 PV: 18 nm rms: 3 nm @ 27 nm λ/9 defocus 0mm radius 24.1µm defocus -50mm radius 85.2µm defocus -100mm radius 166µm

Compact wavefront sensor of Laser Lab Göttingen Very compact design for use behind user experiments Laser drilled Hartmann plate 7µm Al-Folie YAG @ 1064nm, ~100mJ 320µm hole pitch Approx. 50µm hole diameter Image on camera Calculated wavefront Collaboration with Laser Lab Göttingen

Schedule New GMD spring 2009 VLS summer 2009 TOF Spectrometer (first test) october 2008 Compact spectrometer spring 2009 Compact wavefront sensor ~2009 Autocorrelator (direct beamlines) ~2009

Thanks to all our partners: PTB, Berlin IOFFE Institute, St. Petersburg CLRC, Daresbury University of Hamburg BESSY, Berlin University of Münster CNR-INFM, Padova LASER Lab Göttingen

End