USM GT400 Ultrasonic Flowmeter

Similar documents
MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

UIM-4F. UIM-4F for Custody Transfer Measurement Four Paths for Enhanced Accuracy and Reliability

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

OPTIFLUX 5000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

OPTISONIC 7300 Technical Datasheet

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

OPTIFLUX 5000 Technical Datasheet

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

Liquid Ultrasonic Flow Meters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Model Sono-Trak Transit Time

FGM 160 Ultrasonic Flaregas meter. Flare Gas Measurement

OPTIFLUX 1000 Technical Datasheet

Technical Specification FLUXUS ADM 8127B

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

Advanced instrumentation solutions crafted with highest precision

ICARUS ELECTRONIC GAS VOLUME CONVERTER

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

LST100 Ultrasonic level transmitter for upstream oil and gas

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits

The World's Most Versatile Range of. Coriolis Flowmeters

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Using the AcuDew Moisture Transmitter

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

The World's Most Versatile Range of. Coriolis Flowmeters

The World's Most Versatile Range of. Coriolis Flowmeters

PAD - Heavy Duty Differential Pressure Trasmitter

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

The World's Most Versatile Range of. Coriolis Flowmeters

FLUXUS G. Non-Invasive Gas Flow Measurement. Measure from outside what s flowing inside. Gas Storage Facilities. Gas Transmission

SITRANS LR 300: High Performance Radar for Level Measurement

Ambient Conditions. Operating Conditions. Pressure

Coriolis Massflowmeter

FLOW RATE CORRECTION CALCULATOR GDR 1403

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Submersible pressure sensor For superior applications Model LF-1

OPTISONIC 7300 Technical Datasheet

SERVOPRO MultiExact PROCESS ANALYSERS APPLICATIONS FEATURES

Identifying Gas Ultrasonic Meter Problems Using Advanced Techniques

Various Technics of Liquids and Solids Level Measurements (Part 4)

Flow Measurement SITRANS F M

Coriolis Massflowmeter

OPTIFLUX 2000 Technical Datasheet

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

TIDALFLUX 2300 F Technical Datasheet

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Online data sheet FLOWSIC600 GAS FLOW METERS

Design and applications

DigitalFlow TM CTF878

Vortex Meter VTX2. P e

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

ULTRASONIC FLOW METER FT101

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Coriolis Mass Flow Meter Model TM

Technologies, Solutions, and Applications. Magnetic Level Indication and Bridle Measurements

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

wprime TM Series 280W-CI ULTRASONIC WATER METER

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

Rosemount 3101, 3102, and 3105

deltawavec deltawavec deltawavec-f stationary deltawavec-p portable

TMU. Coriolis Mass Flow Meter. for liquids and gas

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

WATERFLUX 3070 Technical Datasheet

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

FLOW RATE CORRECTION CALCULATOR GDR 1403

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

Flow Measurement SITRANS F US Clamp-on

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

A Member of the. Integrated Metering Technologies

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

Electrical Submersible Pumping Systems

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

General Specifications

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

The Rosemount 848T Wireless Temperature Transmitter

OPTIFLUX 4000 Handbook

VITO LT. Global Experience. Locally Applied. A dependable choice.

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

A T u n e d M e a s u r e

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Transcription:

USM GT400 Ultrasonic Flowmeter USM GT400 Ultrasonic Flowmeter Optimized for Custody Transfer for Gas. The GT400 ultrasonic flowmeter is a solution for the most demanding gas flow/volume measurement applications. This innovative 6-path meter replaces older, intrusive meter designs and outperforms other traditional ultrasonic multi-path meters in custody transfer applications. It is available in 4-inch to 24-inch line sizes with industry standard ±0.1% uncertainty. The GT400 is supported by Honeywell s global expertise and unmatched local support capabilities. Proven Technology. Superior Performance.

Applications Key Features Fiscal metering Low-pressure custody/non-custody (atmospheric) transfer Allocation metering Check metering Gas transportation and distribution Underground gas storage (bi-directional) Gas-fired power plants Gas processing plants Refining and petrochemicals Industrial Field proven technology since 1999 in thousands of installations Intuitive RMGView USM software for remote monitoring and meter diagnostics Key Diagnostics Flow profile Performance by path Profile factor Asymmetry Turbulence Automatic gain (AGC) Signal to noise ratio (SNR) Speed of sound (SoS) deviations CEESmaRT compliant wireless remote Condition Based Monitoring solution Optimal path number and arrangement to best characterize flow profile Non-reflective direct path chordal design Six crossed ( X ) paths on three parallel planes for 3D fidelity Truly measures in-plane cross flow Detects asymmetry, single and double helix swirl Insensitive to swirl and velocity profile asymmetry Two paths can fail and meter still measures within fiscal limits per Measuring Instrument Directive (MID) and Measurement Canada Performance exceeds AGA 9 requirements Measurement uncertainty of ±0.1% (flow calibrated) Approved for fiscal metering accuracy to Measurement Canada/MID Measurement capability Bidirectional measurement without pressure drop Turndown ratio: >120:1 at line conditions Gas velocity up to 130 ft/s (40 m/s) for all sizes (fiscal metering) Low-to-high-pressure operation (0 psig-4351 psig, 0-300 barg) Onboard AGA10 SoS calculation with direct GC input Insensitive to regulator noise Proprietary, MID-approved firmware with advanced signal conditioning and high-power transducers handles ultrasonic noise in a wide range without additional noise reducing installations Insensitive to contamination Since measurements are taken without ultrasound reflection, contamination on the pipe wall has no impact on the ultrasonic pulses. Furthermore, the Titanium sensor surface is contaminant-repellent. Patented Live Precision Adjustment/ Echo Measurement Reduces measurement uncertainty due to in-situ auto calibration of internal system delay time (T w) after field replacement of transducers Proven sensor technology Fully encapsulated, high-power Titanium sensors Exd design: ±200 V, 120 khz / 200 khz Operational pressure: 0-4351 psig (0-300 barg) Plug-and-play, field-replaceable design Compact design Standardized meter body length < 24 3DN meter body length 24 2DN meter body length Easy installation and commissioning Honeywell User Experience design enabling efficient operations for technicians Advanced diagnostics Standard System and Communication Capability RS485, Ethernet, analog and digital outputs, high-frequency output Modbus (RTU, ASCII), TCP/IP Industry approvals Metrological: Measurement Canada, PTB, MID Hazardous area: CSA, ATEX, FM Pressure: ASME, CRN, PED, TUV Comprehensive service and support Subject Matter Experts for product and application consulting Honeywell-authorized local/regional field technicians for start-up, commissioning and field service Local technical support (24/7) and responsiveness Spare parts support responsiveness (delivery within 48 hours) Training for operators and field technicians Project engineering, proposals and estimating, and project execution RMGView USM facilitates real-time performance monitoring of CBM parameters Honeywell s advanced 6 Cross ( X ) path technology.

Path Configurations The six acoustic paths with their specific arrangement have the following significant advantages over 4-path meters: Insensitivity: The path arrangement according to Gauss-Chebyshev with its crossed paths makes the gas meter largely independent of the flow profile. Thus, high-accuracy measurement is achieved without a flow straightener even in the case of flow disturbances causing swirl, asymmetry or cross flow. Center Paths: The path arrangement allows for two center paths creating a measurement at the center of the flow profile, which has been proven as a valid diagnostic path within the ultrasonic measurement industry. Symmetry: The path arrangement provides for symmetry within the X, Y, and Z-planes for 3D fidelity. Redundancy: The 6-path meter will not lose its custody transfer metering capability if any one or two of its acoustic paths fail. The failed paths will be reconstructed by means of a replacement-value function learned by the gas meter using the measuring results of all functioning paths. Transferability: The unique 6-path 3D symmetrical layout means that results achieved on a traditional test stand are more readily transferred to actual on-site, non-ideal conditions. Transducer The transducer consists of a piezoelectric crystal fully encapsulated in Titanium housing and operating with a frequency of 120 khz to 200 khz. Its Exd design allows high signal amplitude resulting in high signal-to-noise ratio (SNR) in comparison to traditional intrinsically safe designed transducers. Ultrasonic noise created by gas pressure regulators and control valves at these frequencies has marginal impact on measurements. 120 khz transducer Precision Measurement/ Echo Measurement (Patented) The test for system delay time and adjustment described in AGA 9 (6.3) is necessary due to the fact, that beside the time-of-flight of the ultrasonic pulses, delay times may occur within the system, which are caused by the signal processing electronics, properties of the transducers and calculation algorithms. As these delay times cannot be identified directly, they must be determined at the factory by costly measurement methods. Assuming there is no flow through the meter, the time of flight of a sound pulse is given by the following equation: (Equation 1): t = L/C th + t w t w = t - L/C th Where: t = Transit time upstream (sec) L = Path length (ft or m) C th = Theoretical Speed of Sound (ft/s or m/s) To determine the system delay time t w all other measured values of this equation have to be determined exactly. The ultrasonic gas meter directly measures the time of flight t. The path length L can be measured exactly, at least for all meters with face-to-face arrangement of the transducers (working without reflections). More challenging is the determination of the theoretical SoS C th. It can be calculated by the use of algorithms (AGA8/AGA10), taking into account the gas composition, as well as the actual gas temperature and pressure. To minimize the measurement uncertainty, the meter should be filled with a gas of wellknown speed of sound (e.g., N2). Pressure and temperature have to be kept stable during the measurement and measured precisely. Most critical is the measurement of temperature, as levels of differing temperatures may occur inside of the meter. Obviously, this method includes various possible sources of errors, which contribute to and increase the measurement uncertainty. Most importantly, it is not possible to verify this delay time live in the field, especially after a transducer exchange. Honeywell s patented Precision Measurement/ Echo Measurement method enables the most precise adjustment of delay time and avoids all disadvantages of the classical method described above. For this adjustment, two measurements have to be done per shot: Time-of-flight between S 1 and S 2: t 1 First echo on the receive sensor: t 2 The fundamental equations are: (Equation 2): C 1 = L/(t 1 - t w ) (Equation 3): C 2 = 3*L/(t 2 - t w ) C 1 = C 2 = const. (for short times) Combining equation 2 and 3 and rearrange it to t w: (Equation 4): t w = (3*t 1 - t 2 )/2 Where: t 1,2 = Transit time (sec) L = Path length (ft or m) C 1,2 = Speed of Sound (ft/s or m/s) t w = Delay time (sec) S1 S1 L v C 1, t 1 D 3 x L v C 2, t 2 = 3 x t 1 D Direct USM measurement of signal S2 Echo measurement S2 (continued on next page)

(continued) Instead of the time-of-flight t 1 for direct distance between sender and receiver, the time-of-flight t 2 for the first echo, reflected on receiver and sender, is measured. From Figure 5 it is evident that in this case, the path length is tripled. Both measurements provide a measured value for the speed of sound (C 1 and C 2 ). Out of these measurements, the delay time can be determined precisely and live in the field. This method provides the following unique advantages: Composition of gas inside the meter can be unknown Measurement is independent of the theoretical value of the Speed of Sound As the absolute value of the SoS is not needed, pressure and temperature are not measured Adjustment can take place at any time or after a transducer exchange in the field Determination of the delay time is done automatically Higher accuracy in the determination of SoS Live monitoring of the transducers Standard USM operation without T w calibration vs. USM operation after precision-adjustment mode is switched on Temperature, pressure, moisture, aging of sensors and electronics have no influence on the calibration result Verification of the meter can be performed in the field under operating conditions Figure 6 shows in a very notable way the influence of live dry calibration in comparison to the standard modus without echo measurements. As explained, this echo measurement method allows a much more accurate determination of the speed of sound, and the transit time determination is also more accurate. This implies that the flow measurement accuracy overall is higher than conventional ultrasonic meters without echo measurements. New RMGView USM CBM Key Features: Intuitive Graphical Interface: Flow profile Performance by path Profile factor Asymmetry Turbulence Automatic gain (AGC) Signal-to-noise ratio (SNR) Speed of sound deviations First, RMGView USM monitors the health of the USM GT400 meter and warns if there are any pending problems (e.g., transducer failure). Secondly, it monitors the gas process and alerts when there are any upset conditions (e.g., pipeline contamination, blockages or liquids in the gas stream). Thirdly, monitors calculated metering uncertainties and provides alarm notification. Technical Specifications High pressure > 58 psi/4 bar Qmin Qmax Qmin Qmax Measuring Range ACFH ft/s ACFH ft/s m 3 /h m/s m 3 /h m/s DN 100/4 * 283 0.98 35315 122.82 8 0.30 1000 37.4 DN 150/6 706 1.08 84755 129.93 20 0.33 2400 39.6 DN 200/8 1130 0.99 148322 129.89 32 0.30 4200 39.6 DN 250/10 1766 0.98 233077 129.91 50 0.30 6600 39.6 DN 300/12 2472 0.97 331958 130.78 70 0.30 9400 39.9 DN 400/16 4238 1.05 529720 131.73 120 0.32 15000 40.2 DN 500/20 6357 1.01 829895 131.37 180 0.31 23500 40.0 DN 600/24 9182 1.01 1200699 131.52 260 0.31 34000 40.1 Length Height Width Weight (ca.) Meter Dimensions Diameter Pressure Class (mm) (in) (mm) (in) (mm) (in) (kg) lbs) DN 100/4 * ANSI 600 300 12 330 13 430 17 100 220 DN 150/6 ANSI 600 450 18 340 13 470 19 160 353 DN 200/8 ANSI 600 600 24 360 14 530 21 300 661 DN 250/10 ANSI 600 750 30 380 15 650 26 450 992 DN 300/12 ANSI 600 900 35 395 16 700 28 550 1213 DN 400/16 ANSI 600 1200 47 500 20 750 30 950 2094 DN 500/20 ANSI 600 1500 59 550 22 900 35 1500 3307 DN 600/24 ANSI 600 1200 47 550 22 1000 39 1550 3417 Technical Data Gases Measurements Pipeline Quality Natural Gas, Air Volume Flow, Totalized Volume, Velocity of Gas, Speed of Sound, Swirl Sizes 6, 8, 10, 12, 16, 20, 24 (ANSI 600); Consult Honeywell for sizes > 24. Path Configuration Measurement uncertainty (from Qt to Qmax) Dry calibration with Nitrogen acc. AGA 9 +/-0.5% HP-flow calibration. Full measuring range (Qt to Qmax). +/-0.1% Repeatability Operating Pressure Range Flanges Ambient Temperature Gas Temperature Range Operating Relative Humidity Measuring Interval 6 Direct Cross ( X ) Path; 3 Planes 14.5 psi (1 bar)..4351 (300 bar) up to ANSI600; Consult Honeywell for higher design pressure -40 F (-40 C) to 131 F (+55 C) -40 F (-40 C) to 176 F (+80 C) up to 95% condensing Typically 32 measurements/sec Power supply 24 V/DC +/- 10% Power requirement Hazardous Area Approvals Metrology Approvals Conformoties Electrical Safety Typically 7 W CSA, FM: Class I, Div 1, Groups B, C, D T6; ATEX: Ex II 2G Ex de IIB + H2 T6; IECEx: Ex de IIB + H2 T6 Gb Measurement Canada, MID, PTB AGA9 EMV, Environmental Analog output 0/4-20 ma (galvanically isolated, programmable, load resistor: max. 400 Ohm, Umax = 16 V) Frequency outputs 2 HF-outputs with fmax = 5 khz, Namur pr Open Collector Digital I/O 2 X Programmable Analog input for P&T Galvanically isolated two-wire 4-20 ma p-transmitter or a 4-wire PT100 Interfaces RS 485-0 Service port with MODBUS-Protocol; RMGView USM (max. cable length: 1640 ft); Ethernet via external module RS 485-1 Customizable for special interfacing requirements RS 485-2 MODBUS-protocol for interfacing with Flow Computers, SCADA; Ethernet via external module Standard USM Operation without t w calibration, e.g. on the first factory start-up of the meter or after sensor change. USM Operation after Precision-Adjustment- Mode is switched on! Real time Dry-Calibration under live conditions! Transducer Frequency 120 khz/200 khz for Sizes 8 (DN 200) 200 khz for Sizes 6 (DN 150) RMGView USM Diagnostics Software Visualization, flow data, diagnostics, configuration, parameter changes, export/import of parameters and data Protection IP66 Meter Body Material Casted Steel; CS ASME A352 gr LCC Material Electronics Housing Aluminum cast Color/Finish Metallic Silver (RAL9006, 5-9% gloss) and blue (RAL Design 260 40 40, 5-9% gloss) Installation outside With weather protection cover and sun roof Remarks Consult Honeywell for special requirements *Consult Honeywell for 4 and Sizes > 24

Technical data is subject to change without notice. For More Information To learn more about Honeywell s USM GT400, contact your Honeywell Process Solutions representative, or visit www.honeywellprocess.com. Automation and Control Solutions Honeywell Process Solutions 1250 West Sam Houston Parkway South Houston, TX 77042 1280 Kemper Meadow Drive Cincinnati, OH 45240 www.honeywellprocess.com DS-USMGT400-US March 2014 2014 Honeywell International Inc.