Agilent 87415A, 87400A Microwave Amplifiers

Similar documents
Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent 8761A/B Microwave Switches

Advanced Test Equipment Rentals ATEC (2832)

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent 8902A Measuring Receiver

Agilent 83711B and 83712B Synthesized CW Generators

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Agilent E8267C/E8257C/E8247C PSG

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent dc Electronic Loads Models N3300A-N3307A

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Agilent 84904/5/8M Programmable Step Attenuators for Microwave and RF Manufacturing Test Systems

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent PNA Series RF Network Analyzers

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Advanced Test Equipment Rentals ATEC (2832)

EMC Precompliance Systems and Accessories Catalog

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Agilent E8267C PSG Vector Signal Generator

Advanced Test Equipment Rentals ATEC (2832)

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Agilent U9397A/C FET Solid State Switches (SPDT)

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent 8902A Measuring Receiver Product Note

Agilent 8560 E-Series Spectrum Analyzers

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Advanced Test Equipment Rentals ATEC (2832)

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Agilent PNA Microwave Network Analyzers

5W Ultra Wide Band Power Amplifier 2-18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent EPM Series Power Meters

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

30W Solid State High Power Amplifier 2-6 GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

8W Wide Band Power Amplifier 1GHz~22GHz

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

150W Solid State Broadband EMC Benchtop Power Amplifier 6-18GHz. Parameter Min Typ Max Min Typ Max Units

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Parameter Min. Typ. Max. Units. Frequency Range 8-11 GHz. Saturated Output Power (Psat) 52 dbm. Input Max Power (No Damage) Psat Gain dbm

FMAM4032 DATA SHEET. 10 MHz to 6 GHz, Medium Power Broadband Amplifier with 900 mw, 24 db Gain and SMA. Features: Applications:

Agilent 83554A/83555A/83556A mm-wave Source Modules* Data Sheet

Ultra Wide Band Low Noise Amplifier GHz. Electrical Specifications, TA = +25⁰C, With Vg= -5V, Vcc = +4V ~ +7V, 50 Ohm System

Keysight Technologies USB Preamplifiers

30W Wideband Solid State Power Amplifier 6-12GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

Product Note E5100A-2

FMAM1035 DATA SHEET. 6 db NF Low Phase Noise Amplifier Operating From 3 GHz to 8 GHz with 11 db Gain, 14 dbm P1dB and SMA. Features: Applications:

Features. = +25 C, Vdc = +7V

Agilent 8657A/8657B Signal Generators

Features. = +25 C, +Vdc = +6V, -Vdc = -5V

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Agilent 4-Port PNA-L Microwave Network Analyzer

20W Solid State Power Amplifier 6-18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

DC-20 GHz Distributed Driver Amplifier. Parameter Min Typ Max Min Typ Max Units

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 4285A Precision LCR Meter

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

BROADBAND DISTRIBUTED AMPLIFIER

Parameter Min. Typ. Max. Min. Typ. Max. Units

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent U9391C/F/G Comb Generators

Agilent 8762F Coaxial Switch 75 ohm

Agilent Technologies 3000 Series Oscilloscopes

Agilent J7211A/B/C Attenuation Control Units

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

6 Tips for Successful Logic Analyzer Probing

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Agilent 4-Port PNA-L Network Analyzers

Agilent 87075C Multiport Test Set

100W Power Amplifier 8GHz~11GHz

Transcription:

Agilent 87415A, 87400A Microwave Amplifiers Technical Overview 2 to 8 GHz Features and Description 25 db gain 23 dbm output power GaAs MMIC reliability >1 x 10E6 hours MTBF Compact size, integral bias regulation over 23 dbm output power from 2 to 8 GHz, these amplifiers offer output power where it is needed: at the test port. Both amplifiers offer internal bias regulation and GaAs MMIC reliability, and the 87415A adds integral heat sinking, bias port cabling, and stand-alone packaging for use in test system applications. The 87400A offers similar performance in a compact microcircuit-only package for OEM amplifier applications. The Agilent Technologies 87415A and 87400A microwave system amplifiers bring compact, reliable gain block performance to systems integrators and microwave designers. With 25 db minimum gain and

Packaging These two gain blocks differ primarily in level of integration. Both amplifiers share similar internal GaAs MMIC devices, but the 87415A features a complete, stand-alone solution for test system designers and integrators. An integral heat sink keeps the package at a temperature comfortable to the touch, enhancing its use as a benchtop amplifier, and a DC bias port allows easy connection to an external power supply such as the 87421A. Without the heat sink and base, the smaller 87400A easily fits tight OEM applications. To ensure optimum performance and product life, an external heat sink or forced air cooling is recommended for the 87400A to keep the case temperature below +55 C. 87415A Microwave System Amplifier 87400A 1 Microwave Component Amplifier Specifications Specifications describe the instrument s warranted performance over the temperature range 20 C to 30 C (unless otherwise noted). All specifications apply after the instrument s temperature has been stabilized after one hour continuous operation. Supplemental characteristics are intended to provide information useful in applying the instrument by giving typical but nonwarranted performance parameters. These are denoted as typical, nominal, or approximate. Supplemental characteristics apply over the temperature range 20 C to +30 C. Frequency Range Small Signal Gain Small Signal Gain Flatness Output Power at 1 db Compression Point 2 to 8 GHz 25 db minimum ± 3 db maximum 23 dbm minimum Input SWR 2:1 Output SWR Harmonics 3.6, 2 to 2.5 GHz 3, 2.5 to 8 GHz 20 dbc at Pout = +23 dbm General Specifications Power Requirements Bias Voltage and Current Weight RF Connectors +12 V dc nominal (+11 to +13 V dc); 900mA Net 0.64 kg (1.41 lb) Shipping 1.32 kg (2.9 lb) SMA (f) on RF input and output 1. Agilent 87400A microcircuit specifications and supplemental characteristics apply between 45 to 55 C case temp. 2

Applications The 87415A s compact size makes it an ideal remote amplifier for use by microwave test system integrators. It is a complete, off-the-shelf gain block that enables the system designer to place system power where it is needed, without consuming valuable rack space. Typical applications include microwave test sets and interface matrixes. Loss compensation Compensate for systematic power losses from switching and signal routing ATE systems, frequency conversion, and long microwave cable paths. Use the 87415A microwave system amplifier to recover lost signal strength at test cable ends. Level source output power at a remote test port By combining the 87415A or 87400A amplifiers with an 87300B directional coupler and an 8471E coaxial microwave detector, as shown in Figure 1, levelled source power can be available at the test port. Preamp As a preamp, the 87415A can increase spectrum analyzer and frequency counter sensitivity. Benchtop amplifier for the RF and microwave designer The 87415A microwave system amplifier gives the microwave engineer 30 db gain and 23 dbm output power without consuming valuable bench or rack space. Other applications include antenna subsystems and production test systems. The 87400A OEM component amplifier offers the 87415 s electrical performance in a small microcircuit package. Ideal for instrument applications needing small, internally biased gain blocks, this amplifier offers designers a very small, easy to integrate package, configuration flexibility, and GaAs MMIC reliability. Drive Circuit 8471E Detector RF In RF Out 87415A 87400A Microwave System Amplifier 87300B Coupler Figure 1. External leveling looping Agilent 87421A Power Supply 3

Separate Power Supply The Agilent 87421A power supply provides the dc power needed to bias the 87415A. The power supply is housed in a small separate package, allowing it to be placed up to two meters away from the amplifier. Electrostatic Discharge Caution Electrostatic discharge (ESD) can damage or destroy electronic components. It is recommended that these amplifiers, like other electronic components be installed and operated at a static-free workstation or in an environment where precautions against ESD have been implemented. SMA (f) connectors on all RF ports 76.2 (3.0) 6.1 (0.24) 4.6 (0.18) 88.9 (3.50) RF In RF Out DC In 61.0 (2.40) 7.4 (0.29) 111.0 (4.37) 104.4 (4.26) 8.4 (0.33) 15.3 (0.60) 77.2 (3.04) 16.5 (0.65) 37.0 (1.45) 68.9 (2.71) 102.5 (4.04) 45.2 (1.78) 126.8 (5.0) 65.6 (2.58) 20.3 (0.80) Figure 2. Agilent 87415A outline drawing. Dimensions in millimeters and (inches). 2.74 (0.11 ) 9.05 (0.36 ) 4 x M3.00 x.5 thru 22.37 18.09 (0.88) (0.71) 37.75 (1.49 ) 14.9 (0.58)TYP 43.75 (1.72) 6.1 (0.24) 12.19 (0.48) 54.7 (2.15) 60.7 (2.39) 4 Heat sink this surface Figure 3. Agilent 87400A outline drawing. Dimensions in millimeters and (inches).

Typical Performance Data Saturated Power Level: Input Power Survival Level: Noise Figure: Non-Harmonically Related Spurious: Third Order Intercept (TOI): Impedance: +26 dbm +23 dbm 13 db 50 dbc +34 dbm 50 ohms Power @ 1 db compression (dbm) 26 25 24 23 22 2 4 6 Frequency (GHz) Measured at integer-valued frequency points 8 Reverse Isolation: (S 12 ) Power Dissipation: 60 db 10 W Figure 4. Power Output vs. Frequency 40 Environmental Specifications Operating Temperature: 0 to +55 C Storage Temperature: 40 to +70 C Other Environmental Information Temperature Coefficient of Gain: 0.1 db/ C Temperature Coefficient of 1 dbc: 0.045 db/ C Gain (db) 35 30 25 20 2 8 Frequency (GHz) Random Vibration: Shock: Altitude (non-operating): EMC: 5.2 G(rms) 50 to 2000 Hz per Mil-Std-883C method 2026 test condition IIA 1500 G (peak), 0.5 ms per Mil-Std-883C method 2002.3 test condition B 15,000 m per Mil-Std-883C method 1001 test condition C Radiated Interference is within the requirements of VDE 0871 and CISPR Publication 11 Figure 5. Gain vs. Frequency Harmonic Noise Figure (db) 0 8 16 24 32 40 2G 2.4G 2.8G 3.2G 3.6G 4G Fund Frequency (Hz) Figure 6. Harmonics vs. Frequency 20 16 14 12 10 8 6 0 2 8 Frequency (GHz) Figure 7. Noise Figure vs. Frequency 5

Ordering Information 87415A Microwave System Amplifier Includes amplifier and Agilent part number 83006-60004, which is a two meter cable with a 3-pin connector on one end and three wire leads on the other end. 87400A Microwave Amplifier Microcircuit-only version of 87415A for OEM applications Other Instruments and Accessories 87421A Power Supply Includes power supply and Agilent part number 83006-60005, which is a two meter cable with a 3-pin connector on one end and a D-subminiature connector on the other end. 87300B Coaxial Directional Coupler 8471E 0.01 to 12 GHz Coaxial Detector 83006-60004 dc Bias Cable For use with user supplied power; consists of a two meter long shielded cable with a three pin connector on one end and three wire leads on the other end. Included with the 87415A microwave system amplifier. 83006-60005 dc Bias Cable For use with 87421A power supply; consists of a two meter long shielded cable with a 3-pin connector on one end and a D-subminiature connector on the other end. Included with the 87421A power supply. White/Brown/Grey Ground White/Yellow/Grey (not used).02 (1.0) 2m (79.0) Red Dot Grey +12V Red Dot Figure 8. 83006-60004 DC Bias Cable. Dimensions in meters and (inches). 6

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. Phone or Fax United States: (tel) 800 452 4844 Canada: (tel) 877 894 4414 (fax) 905 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com By internet, phone, or fax, get assistance with all your test & measurement needs Online Assistance: www.agilent.com/find/assist Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 1999, 2000, 2001, 2002, 2003 Printed in USA, October 13, 2003 5091-1358E