HAC-UT V6.3 Wireless Single Meter/Double pipe Metering type Wireless Transmitter. HAC-LMR Wireless Data Receiver/ Repeater Module

Similar documents
HAC-UEM Ultra Low Power Data Radio Module

RF1212 RF1212 Ultra-low Power ISM Transceiver Module V2.0

Low Power with Long Range RF Module DATASHEET Description

SRWF-1021 Series Low Power Wireless Transceiver Data Module User Manual

Embedded Radio Data Transceiver SV611

DRF4463D20 Medium Power ISM RF Transceiver Module V1.21

HAC-HM Series Data Radios

JZ878 RF Data Radio. User s Manual

DRF7020D13 13dBm ISM RF Transceiver Module

E31-TTL-500 Datasheet V Feature E31-TTL-500

RF ISM Transparent Transceiver Module V4.0

DRF4432D20 20dBm ISM RF Transceiver Module V1.21

FC-201/SA Micropower Audio/Data RF Module(433MHz)

DRF7020D20 20dBm ISM RF Transceiver Module V1.31

Purchase the sample: E51-TTL-500 Datasheet V Feature E51-TTL-500

RF7129 Ultra-low power Tranceiver module V2.0

Data. Tran. I. Technical specification. Shenzhen

FC-703C Wireless M-bus Module DATA SHEET

Catalog

SV-MESH Mesh network series Catalogue

SRWF-1022 Series Low Power Wireless Transceiver Module User Manual

RF1276 Long Distance Transceiver module V2.0

VT-CC1110PA-433M. Wireless Module. User Guide

Catalogue

DRF5150S Wireless Sensor Transmitter Module V1.20

DRF5150S Wireless Sensor Transmitter Module V1.30

RF4432 wireless transceiver module

SV613 USB Interface Wireless Module SV613

USB Port Medium Power Wireless Module SV653

Catalog

SA828. SA828 All-in-One walkie-talkie module Description. SA828-U: U band, MHz SA828-V: V band, MHz

Catalog

RF4432PRO wireless transceiver module

RF4463F30 High Power wireless transceiver module

DRF1278F 20dBm LoRa Long Range RF Front-end Module V1.11

SNIOT702 Specification. Version number:v 1.0.1

Catalog

RF-TTL-100 Datasheet. 1. Introduce. 2. Parametric Description. 4. Application. 3. Module Features

VT-CC M Wireless Module. User Guide

2W UHF MHz Radio Transceiver

SMARTALPHA RF TRANSCEIVER

DISCONTINUED. Modulation Type Number of RF Channels 15

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

E45-TTL-100 Datasheet v1.2

DISCONTINUED. Modulation Type Number of RF Channels 15

Radio Module for MHz. Band RMCx4-1 ; RMCx9-1

AT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications

Catalog

Radiocrafts Embedded Wireless Solutions

A RF44 UART TTL modules

HM-TRS Series Transparent Wireless Data Link Module

VT-CC2530-Z1 Wireless Module. User Guide

C Mono Camera Module with UART Interface. User Manual

HC SI4463 Wireless Serial Module

HM-LW-M200 Specification HW-LW -M200. Product Specification V HOPERF All Rights Reserved 1

Product Specifications. Wireless Communication Module

Datasheet LT1110 Wireless Module. Version 3.1

Purchase the sample: E32-TTL-100 Datasheet V Feature E32-TTL-100

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

VT-CC M Wireless Module. User Guide

LORA1276F30 Catalogue

1 What s in the shipping package?

Single Chip High Performance low Power RF Transceiver (Narrow band solution)

3V DUAL MODE TRANSCEIVER 434 MHz BAND Product Code:

LoRa1276 Catalogue

VT-CC1120PL-433M Wireless Module. User Guide

RF4432F27 Catalog

VT-DTMSA5-433M RF Transceiver Module User s guide

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

MY-ZB010C UART to ZigBee Module

SmartRadio Transmitter / Receiver

LORA1278F30 Catalogue

GLOBALSAT GPS Engine Board

HC-12 Wireless Serial Port Communication Module

HM-TR Series UHF Wireless Transparent Data Transceiver

RF NiceRF Wireless Technology Co., Ltd. Rev

AAA. Figure 1: Test setup for output power measurement

LoRa1278 Wireless Transceiver Module

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O

AO-1505-THM ZigBee Temperature and Humidity Sensor

Catalogue

EITF40 Digital and Analogue Projects - GNSS Tracker 2.4

G3P-R232. User Manual. Release. 2.06

E70-433MS14 Datasheet v1.1

DNT900. Low Cost 900 MHz FHSS Transceiver Module with I/O

SYSTEM SENSOR WIRELESS REPEATER PRODUCT SPECIFICATION

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

Datasheet. Bluetooth Smart Module. Pacwave Bluetooth Smart (BLE) Module DESCRIPTION FEATURES

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

Radiocrafts Embedded Wireless Solutions

Single Chip Low Cost / Low Power RF Transceiver

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

ST600 TRANSMITTER OPERATING INSTRUCTIONS

Four channel wireless switch controller SK108

802.11g Wireless Sensor Network Modules

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz. RF Chip Rate 11 Mcps RF Data Rates 1, 2, 5.

Catalogue

CONDOR C1216 GPS RECEIVER MODULE technical notes ZELIA INTEGRATES ANTENNA, GPS RECEIVER, RTC AND LNA

DIGISENSOR CO., LTD Tel.: (848) Website:

Transcription:

HAC-UT V6.3 Wireless Single Meter/Double pipe Metering type Wireless Transmitter HAC-LMR Wireless Data Receiver/ Repeater Module SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD Address: 3rd Area, 19 th Fl, Tower A, HaiSong Building, Tai Ran 9 th Rd, Futian, ShenZhen, China. Tel: +86-755-23981079 23981076 Fax:+86-755-23981007 E-mail:webmaster@haccom.com www.haccom.com

HAC-UT Wireless Single Meter/Double pipe Metering Type Wireless 1 Features: collecting, metering, wireless data communication, soft clock, ultra low power consumption, power management, break line fault detection, low cost and multifunction integrated in one module. The module measures the impulse of gas meter water meter, quantity of heat meter and so on. It transmits the metering data and some related states to the concentrator randomly or timely. 2Function introduction: The single module support single meter/double reed switch, low cost. Accurate impulse filtering, collecting circuit and metering algorithm, higher precision. Reliable, stable and long distance data transmission. The communication distance is much further owning to the automatic intermediate function. Ultra low power consumption, the average consumption is less than 20µA. The detection function of power voltage will give out a alarm signal when the power of battery is almost run out. If the circuit is broken naturally or from spite, the break line fault detection will sound the alarm. 3. Power Supply: Under metering and transmitting state, the working voltage is +3.1~3.6VDC Sleeping current is equal to or less than 15µA; Transmitting current is equal to or less than 40mA, duration for transmitting one group data is equal to or less than 230ms; Average interval time of transmitting is equal to or more than 3 hours; Average working current is equal to or less than 20µA; The voltage for initialization is +2.5~5.5VDC; 4. Configuration sketch map:

5. Interface Definition and Instructions: JP1: Pin1: GND Pin2: Vcc Pin3: RxD the input of setting initial information Pin4: TxD power on or finishing setting, the output of initial information Pin5: SGND Signal Ground, it can be used for the common grounding of reed switch Pin6: A the incoming end of reed switch A Pin7: B the incoming end of reed switch A Pin8: TA the break line fault detection, connected to the ground when stalling Pin9: TB no definition JP2: Pin1: GND Pin2: Vcc Pin3: RxD the input of setting initial information, the same as JP1; Pin4: TxD power on or finishing setting, the output of initial information; the same as JP1 Pin5: SET_EN initial setting enable, this pin keeps low level. When RxD/TxD is effective, we can set the initial information. Pin6: RESET negative impulse resets the singlechip SWITCH: Reed switch, you can use a magnet suction to get a negative pulse. If the Reed switch has a negative impulse of more than 100ms, the module will transmit data once every 4 seconds. It transmits 16 times continuously in order to installing or producing/testing. MCU can save all the current data of RAM to EEROM before transmitting. So this pin can be considered as a saving data signal before power off. When the module is powered up, MCU will recover the program from EEROM automatically. 6. The Method of Initialization and Instruction: Keep the SET_EN stay low level and transmits information with 1200 N81 format to RxD which are shown as follow: The quantity of initialization transmitting byte: 13Bytes 0FFH,$,T,ID5,ID4,ID3,ID2,ID1,PN,S,DH,DL,E Here: 0FFH, $ denote code and they are necessary. T is the number of the concentration that the module belonged to. ID5, ID4, ID3, ID2, ID1 are 10 bits meter number, BCD code, the high bit is ahead. PN is impulse constant, Hex, the value is 1~255, it indicates how many impulses represent 1 ton water. S is the state byte of meter, specific definition will be explained later. DH, DL are the reading of meter, Hex, the unit is ton, the value is 0~65535. E is the pulse number of decimal fraction in the reading, Hex, the value is 0~PN-1.

Note: E is expressed by the number of impulse in the RAM. When initializing E, we need to convert the decimal fraction of initialization reading to the pulse number, then write it to EEPROM and RAM. 7. The Data Format Transmitted In The Air: when the impulse constant is equal to or less than 10, the transmission in the air proceeds once as the module meters one impulse, or else it transmits once every 10 impulses. If we didn t meter impulse for a long time, the module transmits data every 4 hours timely. The data format transmitted in the air is shown as below (14 bytes): $ T ID5 ID4 ID3 ID2 ID1 PN S DH DL E CRCH CRCL Here: $: symbol code, it doesn t contain in CRC checking T: the number of concentrator ID5, ID4, DI3, ID2, ID1: the number of meter PN: the impulse constant, Hex, the value is 1~255, it indicates how many impulses represent 1 ton water. S is the state word of meter, the definition is shown in the table: S7 S6 S5 S4 S3 S2 S1 S0 Break Power Sign of Type of Overflow reservation Testing EEPROM line state A/B meter Here: S7: the sign of overflow, S7=1, it means the reading is equal to or more than 65536; S6: the sign of break line, 0: normal condition, 1: break line; S5: reservation, it has no definition at present; S4: testing sign, 0: normal data, 1: testing signal; S3: writing the EEPROM state, 0: successfully writing, 1: failure; S2: power state, 0: the power is in regular state, 1: the voltage is not enough; S1: reservation, it has no definition at present; S0: the type of the meter, 0: water meter; DH: the high bit of reading DL: the low bit of reading, the maximum value of DH_DL can indicate 655356 tons of water. E: the decimal fraction of reading, e.g.: E=19H, it means 0.25 ton. CRCH: the high bit of CRC checking, the checking doesn t contain $ symbol code CRCL: the low bit of CRC checking This CRC checking verifies 11 words that mentioned before. The multinomial of CRC is $1021.

8. The Preserve Method for Current Data in EEPROM: After initialization, the permanent data kept in EEPROM contain: the number of concentrator, the number of meter, the impulse constant and so on. The program can t be changed in the process of using once the permanent data has been initialized. Unless we initialize the data newly, it can be changed. The temporary data are: the state word, the reading, the decimal fraction of reading, etc. These data will be changed in company with the reading. The specific regulations are shown below: The state word and the reading in the EEPROM are refreshed once after we has counted 1 ton of water, the decimal fraction will keep 0 all the time. We adopt this way according to the service life of EEPROM (the service life of EEPROM in ATMEGE48V is 100,000 times). If the module is start again after power off, the state word and the reading can be recovered accurately but the decimal fraction will be lost, it causes some errors. In order to reduce metering error and not to loss the decimal fraction, customer can connect RxD/T_EN with ground before factitious power off, announce the module to save all the data to EEPROM, then shut off the power. Additionally, for the sake of preventing damaging EEPROM after too many times writing, the program will read and compare it after writing to EEPROM. If there are any mistakes in writing, it can be shown in the state words when transmitting data. HAC-LMR Wireless Receiver/Repeater Module The data transmitted from HAC-UT are transmitted to the concentrator through UART port in the format of 1200 N81. If we use the repeater, it will send the data out from serial port, at the same time, it will send the data to the air. The coverage of concentrator can be extended by relaying function. Note: The receiver doesn t have the function of check out the mistake if the received data has mistake. The data are still transmitted from serial port or repeater. (If customer wants to filter the error data, our company will also support). The multinomial of CRC checking is $1021. 1. Power Supply: Power Supply: +5.0VDC; Receiving current: =50mA; The maximum transmitting current: =400mA. 2 Interface definition and instruction: JP1 Pin1 GND Pin2 Vcc Pin3 RxD no definition.

Pin4 TxD the data sent by data collection or repeater will be output to concentrator by this pin. Pin5 SGND signal ground. Pin6 A no definition. Pin7 B no definition. Pin8 SLP if receiving the correct data from the air, and the pin will output 120ms high level. As the correct indicator, it can be in series with a resistance with 470ohm to drive the LED directly. Pin9 RESET 3. Configuration sketch map: JP2: There are 5 short circuits called ABCDE, they are shown as follow: A is used to control the transmitting power of repeater, its definition is shown as follow: A=1, transmitting power: +27dBm A=0, transmitting power: +20dBm DCB are used to control the send/receive delay time for repeater transmitting, their definition are shown as follow: DCB=111 repeater transmits data after delay waiting for seven time slices DCB=110 repeater transmits data after delay waiting for six time slices DCB=101 repeater transmits data after delay waiting for five time slices DCB=100 repeater transmits data after delay waiting for four time slices

DCB=011 repeater transmits data after delay waiting for three time slices DCB=010 repeater transmits data after delay waiting for two time slices DCB=001 repeater transmits data after delay waiting for one time slice DCB=000 repeater transmits data after delay waiting for no time slices 0 indicates plug the short circuits, 1 indicates hang in the air. One time slice is equal to 300ms. If the E of JP2 is plugged by short circuit, and the module will be defined as repeater, or it will only receive and not send. If the Pin6 (A) of JP1 is plugged by short circuit, the module will enter into the production testing state after be electrified. Note: The repeater can t transfer the data which has been sent by the other repeaters. III. Power consumption of HAC-UT Wireless Data Transmit Module 1 Sleeping Current: The definition of the idle state for the module is: the power supply of RF is shut off and the MCU works in the mode of saving power (The main block stop vibrating, but the 32.768KHZ clock is vibrating from beginning to end). Each I/O port keeps their proper conditions. Sleeping current is 15 µa. 2. Soft Clock Count State: MCU is waked up by the time clock every 62.5ms and it counts the soft clock. The awaken time lasts 31.25µs. MCU works while the power supply of RF is still shut off during the awaken time. The working current of MCU is equal to or less than 5mA. The average consumptive current during the soft clock s count state is: 5000µA 31.25µs/62500µs=2.5µA 3. RF Transmitting State: The RF circuit transmits one time every 4 hours or when it has measured 0.1 ton of water. Each transmission lasts 230ms and we calculate the transmitting current according to 40mA (actually it is about 35mA). Suppose the circuit transmits once in 3 hours on average, the current in transmitting state is shown below: 40000µA 0.23s/(3 3600s)=0.85µA 4. The Total Power Consumption: 15+2.5+0.85=18.35µA The manual gives out the total power consumption of this type is equal to or less than 20µA

IV Performance Parameter HAC-UT Collecting and Transmitting module Transmitting power The visible distance Air baud rate Topology Network Voltage Transmitting current Sleeping current Carrier frequency Channel Communication mode Bandwidth Dimension Antenna Antenna impedance Weight Working temperature Frequency stabilization 15~20mW 800m 1200bps Multi-point to point 3.1V~5V <40mA <15µA 430.375MHz Single channel Single transmitter 10kHz 47mm 26mm 8mm spring antenna called HAC-TH433-B 50 22g -20 ~+60 ±5PPM HAC-LMR Wireless receiver/repeater module Transmitting distance The visible distance Receiving sensitivity Air baud rate Frequency stabilization Topology Network Voltage Transmitting current Receiving current Communication mode 500mW (default), 100mW (optional) 800m -124dBm 1200bps Industrial grade: 2.5ppm Commercial grade: 5ppm Multi-point to point 4.75~5.5V DC <400mA <50mA Half-duplex Frequency Default interface mode Dimension Weight Antenna impedance Antenna 430.375MHz TTL 1200bps 8N1 (only output the data) 53mm 38mm 10mm 34g 50 including SMA 10cm helical antenna, magnetic antenna (optional) Working temperature Industrial grade: -40 ~+80 (TCXO ) Commercial grade: -20 ~+60