Keywords: 1 = quality 2 = glazing 3 = laminated glass 4 = standard. Abstract

Similar documents
DRAFT STANDARDS (September 2010) - pren ISO (documents on mechanical strength measurement methods): revision

Relevant standards and guidelines

Tempered Glass. Tempered glass. Product introduction

PLANE Line PL 901 BASIC

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

INFORM COUNTER SYSTEM

Glass in every form. HERO Form

OPALIKA. White flashed opal glass

1 Tempered Glass. Effect Comparison. 1. The common glass falls into pieces with sharp edges when it's broken.

Waist-high Railing System from Tempered Glass BH-06 ASSEMBLY AND OPERATION MANUAL

Hardware Fitting Accessories Door Seals

This document is a preview generated by EVS

Decorative Laminated Architectural Glass

ELECTRONIC DISPLAY. "Best in Show" award winner of "SID Display Week 2014"

V. TECHNICAL ANNEXES REGULATIONS

Overcurrent Protection / 7SJ45

FLAT GLASS TECHNOLOGY

HH Windows & Doors German engineered. American made. the horizontal pivot window

Technical Information Smartec CLD18

ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 3: Standard penetration test

heroal non-insulated profile systems

FMT4R FM Transmitter User s manual

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

WATER AND WASTEWATER TREATMENT Codes of Practice and Standards - Vadim A. Taktashov

Avery Dennison Architectural Window Films

ACTIVITY OF RUSSIAN FEDERATION ON SPACE DEBRIS PROBLEM

Acid etched float glass

STADIP LITE Weight-saving solution

WITH HEAT - NATURALLY

ISO INTERNATIONAL STANDARD. Guidelines on types of glass of normal bulk-production composition and their test methods

LP PYRA 03. REV jan. 2007

THE HIGHEST QUALITY WO0DEN WINDOWS AND DOORS

Description. Applications. GOLDEN FAITH SILVER MIRROR ultra durable coating silver mirror

Fire testing: Calibration of smoke opacity measuring systems

CONSTRUCTION PRODUCT TECHNICAL CARD

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Kittec -CBG Gas. U s e r s M a n u a l

Sky-Frame. Technical Newsletter ( ) New Sales Partner Documentation. New Sales Partner Documentation

USES AND APPLICATIONS

and constantly reviewing its data, SCHOTT assumes no liability or guarantees for the completeness, correctness or up to

Term Info Picture. A wave that has both electric and magnetic fields. They travel through empty space (a vacuum).

LP PYRA 02. REV jan. 2007

Glass Systems. Technical Information on Pilkington Profilit Profiled Glass with System. - English Edition - Pilkington Profilit

COMITÉ EUROPÉEN DES ASSURANCES

The matte surface is created and protected with acrylic varnishes, the high gloss surface is proteced by pressing with melamine.

INNOVATION IN WOODWORKING INDUSTRY AND ENGINEERING DESIGN, 1/2014 (5): 33 39

STRUCTURAL FINGER JOINTED SOLID TIMBER

Recommended Applications for Heat-Treated Glass

24 hours/daily. REZULT Quality. REZULT Technology. REZULT Enterprise. REZULT Material. REZULT Ecology. REZULT Customer focus. REZULT Reliability

Technical Information Smartec CLD18

ACRYLITE RinkShield. Physical Properties. Technical information

3. Health and safety Operator safety Fastening safety Functional safety 3.1 Operator safety Hilti DX/GX piston principle

P250A PNEUMATIC FLOORING TOOL OPERATING INSTRUCTIONS

RATIO / INFORM RADIUS SHELVING

Selection Guide for Flat Thermally Toughened Soda Lime Silicate Safety Glass

USES AND APPLICATIONS

(

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

Contemporary architectural design glass

Fading Protection and SageGlass Products

> Appearance Factors > Health and Hygiene > Technical Specification > Sustainability

sedak ceramic-ink printing Printing glass of unique dimensions

SECTION HOLLOW METAL DOORS AND FRAMES

USES AND APPLICATIONS

Caravan Materials. Engineered to Perform Better

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

DOORS DOOR FRAME PLYWOOD BLOCK BOARDS

GLUED SOLID TIMBER DUO/TRIO

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 3254 J/2H3P

Estra. ...a life saving solution. Glazed louvred smoke ventilator (0)

STANDARD SPECIFICATION. Non-rechargeable Li-SOCI 2 cell. LS 14500W Type. Lithium Product Manager. Primary Lithium Quality Manager

Manufacturing Instructions Requirements and principles

the quality aspects of laminated TAMGLASS OY glass are also briefly discussed. Jorma Vitkala* NTRODUCTORY REMARKS

Product Guide Windows. Transform ordinary spaces with high quality, eye-catching window graphics

Article List Portavant 120 Complete Sets. Smooth cushioning, gentle closing

PFPF and FTSG Agreed Assessment Rules for: Timber Based Doorset. FTSG N288 (e)

penthouse... 8 loft...16 suite...26 studio... 38

Product data sheet Palas Fidas 200 E

SINEAX B 811 Power Pack with additional Functions

The New Standard in Lightfastness Testing. Q-Sun B02 Xenon Lightfastness Tester. The Lightfastness Specialists

NOTICE. (Formulated under the cognizance of the CTA R7 Home Networks Committee.)

ARCHITECTURAL STICK SYSTEMS

ZHM CT Series. Technical Datasheet. Gear Flow Meters in Cartridge Design for paint applications, optimized with regard to flushing and to weight

ISO INTERNATIONAL STANDARD. Glass in building Silvered, flat-glass mirror. Verre dans la construction Miroir argenté en verre plat

General Characteristics of Solidfloor TM engineered flooring

110FC STRAIGHT LINE EDGER VICTRALUX 110FC MODEL VICTRALUX 110FC

6 mln. 170 mln euro. Korosten MDF manufacture. The annual output of MDF production is. The annual output of laminate is

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

AMIRAN the glass you can t see

Future climate adaptive building shells 'Optimizing energy and comfort by inverse modeling'.

This document is a preview generated by EVS

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

Expand your horizons German High Quality Aluminium Door & Window Systems

or if you want more control you can use the AddDamage method, which provides you more parameter to steering the damage behaviour.

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Product Data Sheet 3252J/2H3PU

Transcription:

New standard on laminated glass for buildings Olga A. Emelianova, Alexander G. Chesnokov (Glass Research Institute, Moscow) Dushinskaya str. 7, 111024 Moscow, Russia Keywords: 1 = quality 2 = glazing 3 = laminated glass 4 = standard Abstract New standard of CIS GOST 30826-2001 on laminated glass for the building purposes is presented in this paper. This standard joined into force recently. This new interstate standard was developed and approved in 2001. The standard makes the same technical requirements to all laminated glasses for buildings. These requirements ascertain possibility of using of these glasses in building and include: appearance factors, edge processing, thermal and water resistance, resistance to ultraviolet radiation, humidity resistance and optical distortions. Furthermore, laminated glasses for buildings in depending on the field of using can possess special properties such as: protective (safety during use, impact proof, bullet proof and explosion protective), fire proof, sound insulation, increased endurance etc.

2 Distinctive feature of this Russian standard in comparison with European standards is incorporation of all kinds of laminated building glass in one document. The standard contains classification of all laminated glasses in dependence of field of application, requirements and testing techniques for every type of laminated glass, guidelines for using. All these measures facilitate choice of right laminated glass for the specific project. Introduction In this presentation we introduce new CIS GOST 30826-2001 standard Laminated sheet building glass. Specifications. This standard is implemented in Russia from January 01, 2003. Last years in Russia demand on laminated building glass is increased significantly. Laminated glass has many advantages and may be increased mechanical strength, secure during exploitation (and don t break due to accidental strikes, don t drop-out in large sized pieces which can traumatize people), resistant to criminal force of the person (for example, hammering by hard items as axe, hammer, stone etc), resistant to fire-arms shots or impact from blast wave. New fields of glass application are appeared recently (at least in Russia) such as glass floors, sunroofs, interior walls. These applications have special requirements to the mechanical loads and fire resistance that are normal for the building constructions but they were not affected to the glass products early.

3 Expansion of these new fields rides on the one hand by opening of new banks, shops and passages with jewelers, electronics, photo and video, restaurants, casinos and others places of the same kind. On the other hand it rides from worsening of criminal situation in the country and growing concern for people safety indoors or near many-storied building. The main text All above-stated thoughts suggest to necessity of development of new State standard for the laminated building glass. During this work we assume standards of CEN and ISO listed below as a basis: EN 356 Glass in building - Security glazing - Testing and classification of resistance against manual attack EN ISO 12543:1 Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:1998) EN ISO 12543:2 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:1998) EN ISO 12543:3 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:1998) EN ISO 12543:4 Glass in building - Laminated glass and laminated safety glass - Part 4: Test methods for durability (ISO 12543-4:1998) EN ISO 12543:5 Glass in building - Laminated glass and laminated safety glass - Part 5: Dimensions and edge finishing (ISO 12543-5:1998) EN ISO 12543:6 Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance (ISO 12543-6:1998)

4 рr EN 12543:1998 Glass in building - Laminated glass and laminated safety glass - Part 7: Evaluation of conformity рr EN ISO 14440 Glass in building - Specification for security glazing - Explosion-pressure-resistant glazing - Classification and test method (ISO/DIS 14440:1994) As it can be seen every one from the CEN (ISO) standards affects only one field of application or requirements whereas Interstate standard consolidate all types of laminated glass in one document. Depending on the field and specificity of application determine in this standard classification of all kinds of laminated glass, requirements applied to every type of laminated glass and testing methods, instructions about its use. All this information lightens the work and allows customer or developer to make a right choice from variety of laminated glass types and to use that he need in fact. Laminated glass for building is subdivided into types depending on purpose: 1. resistant to mechanical loads: a. secure during use (resistant to soft body impact); b. resistant to hard objects impact; c. bulletproof; d. explosion protective; 2. fire proof; 3. sound insulating; 4. frost-resisting;

5. laminated glass with special properties (for example, with radio-interference defense, biological protection, informational defense, increased endurance etc). 5 All laminated glasses for building are the subject of the same technical requirements similar to ISO and CEN standards which determine possibility of there using in building such as: appearance factors, requirements to edge working, ultraviolet radiation effect resistance, moisture resistance, optical distortions. In addition every type of laminated glass has its own specific requirements. So secure or safety during exploitation glass is subdivided into 4 protection classes depending on resistance to soft body impact: SM1-SM4 (drop height: SM1-300 mm, SM2-700 mm, SM3-1200 mm and SM4-2000 mm). Methodology of the indicated requirements corresponds with American standard ANSI Z97.1-1984 and German standard DIN 52337. In ANSI Z97.1-1984 laminated glass is tested in accordance with protection classes with the next heights: 300 mm, 450 mm, 1200 m. DIN 52337 describes testing with heights 300 mm, 700 mm, 1200 mm, i.e. DIN 52337 is closer to CIS standard than American standard. However no one in this standards have protective class with testing height 2000 mm, so our interstate standard lets test laminated glass with more strict requirements. Laminated glass resistant to hard body impact is subdivided into protection classes identically to European standard EN 356 so we consider that there is no reason to examine it in detail. Laminated explosion protective glass is subdivided into 14 protection classes depending on capability to absorb limiting value of blast wave specific impulse (dynamical load from blast wave) effecting on the glazing. There are taken into account charge mass

6 (kg), distance from the location of possible explosion (m), value of blast wave specific impulse (Pa/s), pressure of blast wave (kpa) during classification. Protection classes of laminated blast-proof glass K11 - K14 in GOST 30826-2001 entirely comply with classes ER1 ER4 from рren ISO 14440 Glass in building - Specification for security glazing - Explosionpressure-resistant glazing - Classification and test method (ISO/DIS 14440:1994). Laminated bulletproof glass is subdivided into 9 protection classes depending on resistance to effect from certain types of weapon and ammunition mainly used on the territory of Russian Federation and CIS states. Classification takes into account appellation and index of the cartridge, bullet characteristics (core type, mass, g, velocity, m/s), firing distance. Due to the fact that there are severe climatic conditions on the most part of the Russian territory, one more laminated glass type is included in standard. This is frost-resisting or frostproof glass. Laminated frost-resisting glass must sustain minimal calculated temperature at which it ll be used. Corresponding to it functions such glass is tested in climatic chamber at the temperature on five degrees below minimal calculated exploitation temperature. Laminated sound insulation glass is subdivided into 5 classes depending on decrease of air noise from urban transport current. Subdivision principles for sound insulation glass coincide with pren 12758-1 Glass in building - Glazing and airborne sound insulation - Part 1: Definitions and determination of properties.

7 Laminated fire proof glass is subdivided depending on resistance to fire influence during the time in minutes to integrity loss (E). One in limiting conditions in ЕN 357 Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance is integrity loss too. Hence we can see that this Interstate standard of CIS on laminated glass includes a lot of requirements which related to laminated glass used in construction industry. For the customer that means one thing if he knows requirements to apply to glazing, he can find answer about all types of laminated glass in one standard GOST 30826-2001 Laminated sheet building glass. Specifications. And he doesn t need to learn many normative documents to find all interesting information. 2003