AORC Technical meeting 2014

Similar documents
DC current interruption tests with HV mechanical DC circuit breaker

Stress Analysis of HVDC Circuit Breakers for Defining Test Requirements and its Implementation

Impacts of DC Circuit Breakers on AC/DC System Stability Subject to DC Faults

ELEMENTS OF FACTS CONTROLLERS

Sequential Tripping of Hybrid DC Circuit Breakers to Enhance the Fault Interruption Capability in Multi-Terminal DC Grids

DC Chopper Based Test Circuit for High Voltage DC Circuit Breakers

Transient system behaviour under DC fault conditions in meshed HVDC system

Transient Recovery Voltage (TRV) and Rate of Rise of Recovery Voltage (RRRV) of Line Circuit Breakers in Over Compensated Transmission Lines

DC VACUUM CIRCUIT BREAKER

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

A New Subsynchronous Oscillation (SSO) Relay for Renewable Generation and Series Compensated Transmission Systems

Tab 2 Voltage Stresses Switching Transients

Analysis of Transient Recovery Voltage in Transmission Lines Compsensated with Tpcs-tcsc Considering Accurate Model of Transformer & Generator

A Methodology for the Efficient Application of Controlled Switching to Current Interruption Cases in High-Voltage Networks

A TECHNICAL REVIEW ON CAPACITOR BANK SWITCHING WITH VACUUM CIRCUIT BREAKERS

High Voltage DC Transmission 2

2. Current interruption transients

GIS Disconnector Switching Operation VFTO Study

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

Modelling of Sf6 Circuit Breaker Arc Quenching Phenomena In Pscad

D6.2 Develop system level model for mechanical DCCB

Impact of SFCL on the Four Types of HVDC Circuit Breakers by Simulation

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

Using Fault Current Limiting mode of a Hybrid DC Breaker

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Copyright 2008 IEEE.

Z-Source Circuit Breaker Utilizing Ultra-Fast Mechanical Switch for High Efficiency DC Circuit Protection

(2) New Standard IEEE P (3) Core : (4) Windings :

Transient Recovery Voltage at Transformer Limited Fault Clearing

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

System grounding of wind farm medium voltage cable grids

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

Fault Current Characterisation in VSC-based HVDC Systems

Power System Reliability and Transfer Capability Improvement by VSC- HVDC (HVDC Light )

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

ANALYSIS OF FAULTS INTERRUPTED BY GENERATOR

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION

Fixed Series Compensation

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Overview of Actuation Thrust

Solving Customer Power Quality Problems Due to Voltage Magnification

SolidGround TM grid stability and harmonics mitigation system Geomagnetic Storm Induced Current (GIC) and Electromagnetic Pulse (EMP) protection

FACTORY AND FIELD VERIFICATION TESTS OF CONTROLLED SWITCHING SYSTEM

Great Northern Transmission Line: Behind the (Electrical) Design

Switching Induced Transients:

Effects of Phase-Shifting Transformers, and Synchronous Condensers on Breaker Transient Recovery Voltages

5. Black box arc modelling

Considerations for the Application of Thyristor Controlled Series Capacitors to Radial Power Distribution Circuits

Evaluation of coupling between dc and ac transmission lines on the same right-of-way: Parametric analysis and mitigation methods

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

High voltage engineering

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Overview of Actuation Thrust

Power Quality and Reliablity Centre

Short-Circuit Analysis IEC Standard Operation Technology, Inc. Workshop Notes: Short-Circuit IEC

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Modeling insulation in high-voltage substations

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

DC Line Protection for Multi-terminal (MT)- HVDC Systems

Fault Analysis of ITER Coil Power Supply System

DEVELOPMENTS IN EHV/UHV CIRCUIT BREAKER TESTING

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

A New Network Proposal for Fault-Tolerant HVDC Transmission Systems

Revision of TRV Requirements for the Application of Generator Circuit-Breakers

Cahier technique no. 101

Abstract. 1 Introduction

Ferroresonance in MV Voltage Transformers: Pragmatic experimental approach towards investigation of risk and mitigating strategy

Impact of VSC Converter Topology on Fault Characteristics in HVDC Transmission Systems

An Introduction to the CSCT as a New Device to Compensate Reactive Power in Electrical Networks

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Poornima G P. IJECS Volume 3 Issue 6 June, 2014 Page No Page 6453

ATC s Mackinac Back-to-Back HVDC Project: Planning and Operation Considerations for Michigan s Eastern Upper and Northern Lower Peninsulas

Delayed Current Zero Crossing Phenomena during Switching of Shunt-Compensated Lines

U I. HVDC Control. LCC Reactive power characteristics

USE OF HVDC MULTI TERMINAL OPTIONS FOR FUTURE UPGRADE OF THE NATIONAL GRID

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Estimation of Re-striking Transient Overvoltages in a 3-Phase 132KV Gas insulated Substation

VSC Transmission. Presentation Overview. CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April LCC HVDC Transmission

Fundamental Concepts of Dynamic Reactive Compensation. Outline

DC Transmission Grid with Low Speed Protection using Mechanical DC Circuit Breakers

Estimation of Re-striking Transient Over voltages in a 132KV Gas insulated Substation

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

II. RESEARCH METHODOLOGY

USING SUPERIMPOSED PRINCIPLES (DELTA) IN PROTECTION TECHNIQUES IN AN INCREASINGLY CHALLENGING POWER NETWORK

Investigation of Inter-turn Fault in Transformer Winding under Impulse Excitation

Standards Developments for Fault Current Limiters

In power system, transients have bad impact on its

Should we transform our lines to HVDC?

Markus Abplanalp, 7. Braunschweiger Supraleiterseminar, Strombegrenzerkonzepte im Vergleich

forces to improve electric power systems of today and tomorrow.

Analysis of a 405 km transmission line with series compensation

CONTENTS. 1. Introduction Generating Stations 9 40

A Special Ferro-resonance Phenomena on 3-phase 66kV VT-generation of 20Hz zero sequence continuous voltage

Exercises. 6 Exercises

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

A Study on Ferroresonance Mitigation Techniques for Power Transformer

Digital Fault Recorder Deployment at HVDC Converter Stations

Transcription:

http : //www.cigre.org B4-112 AORC Technical meeting 214 HVDC Circuit Breakers for HVDC Grid Applications K. Tahata, S. Ka, S. Tokoyoda, K. Kamei, K. Kikuchi, D. Yoshida, Y. Kono, R. Yamamoto, H. Ito Mitsubishi Electric Co. Japan SUMMARY High Voltage Direct Current (HVDC) transmission has been expanding due to rapid development of power electronics technology and by the need for connection of offshore or remote wind farms and /or large hydro power generators. HVDC transmission has several benefits such as lower transmission losses, fewer lines required for the same power transmission, and less system stability problems. CIGRE Study Committee (SC) B4 leads the HVDC investigations and provides a platform for greater engagement of other SCs on HVDC grid issues. For example, SC A3 and B4 have just established a JWG A3/B4.34 on DC switchgear potentially applicable to future HVDC grids. Multi-terminal HVDC systems require maintaining operable converter stations connected to healthy lines, when the DC voltage collapses at a remote terminal due to a system fault. To ensure such operability, DC circuit breakers (DCCB) are indispensable and their fault clearing times are crucial. The fault clearing times vary depending on the system configuration (radial or meshed network), design parameters of the voltage source converter (VSC), transmission capacity, presence of series connected reactor and impedance of line/cable. However, DCCBs are required to clear the fault with a shorter time as compared with AC circuit breakers. In this paper, the capability of DC current interruption was investigated using a mechanical type DCCB prototype with a forced current zero formation scheme, which superimposes a high-frequency (higher than several khz) inverse current on the fault and normal interrupting currents. The requirements for DCCB were also analytically evaluated using a four-terminal radial HVDC network model. The DC interruption tests using the DCCB prototype with a forced current zero formation scheme demonstrated that it can clear up to 16 ka DC currents within a few milliseconds after an opening command. KEYWORDS HVDC Grid - DC current interruption - Mechanical DC Circuit Breaker - Forced current zero formation scheme - Fault clearing time - Series-connected reactor Tahata.Kazuyori@ea.MitsubishiElectric.co.jp

1. Introduction HVDC transmission has been expanding due to rapid development of power electronics technology and by the need for connection of offshore or remote wind farms and / or large hydro power generators. CIGRE Study Committee (SC) B4 established various WGs and leads the HVDC investigations. For example, WG B4.52 summarized a feasibility study of HVDC and B4/B5.59 is investigating control and protection of HVDC grids. They will provide a platform for greater engagement of other SCs on HVDC grid issues. SC A3 and B4 have recently established a JWG A3/B4.34 on DC switchgear potentially applicable to future HVDC grids. A HVDC grid will be required to operate the healthy lines continuously, even if a voltage collapse at the remote end occurs due to a fault. Rapid fault clearing is essential for DCCB even though the requirement varies depending on: 1) DC transmission system configurations, 2) Voltage Source Converter (VSC) design, 3) transmission capacity, 4) DC reactor connected in series with the line/cable, and 5) impedance of the line/cable. The JWG A3/B4.34 on DC switchgear will investigate (1) the expected specifications of DC switchgear for different HVDC applications (point-to-point connection, radial/meshed multi-terminal systems and off-shore/remote wind farm connection), and also (2) the performance of existing DC switchgear (Circuit breaker, Disconnecting switch, Earthing switch, By-pass switch). The JWG will focus especially on the possibility of a mechanical DC circuit breaker with different technologies. DC fault current can be interrupted when the current is forced to zero crossing. Figure 1 shows different schemes for the current zero formation. (a) Current limiting switch This scheme can be often applied to low voltage class DC No-Fuse Breaker (NFB). For example, 2kV air-blast type high-speed switch is used for railway power systems. However, it could be difficult to design High-voltage DC circuit breaker based on this scheme, since the arc voltage induced by air or SF 6 across the contacts of the breaker (several kv at maximum) limits the DC current and creates a current zero. [1], [2], [3] (b) Passive resonant current zero formation This scheme can be often applied to Metallic Return Transfer Breaker (MRTB) which clears the neutral current (up to a few thousand amperes) flowing through a neutral line of a HVDC transmission system. The parallel capacitor and reactor across the circuit breaker form a passive resonant circuit that generates an expanding current oscillation with a frequency range of 1-3 khz, which eventually leads to a current zero. The scheme generally needs 2-4 milliseconds for fault interruption. (c) Forced current zero formation (Active resonant current zero formation) This scheme can be potentially applicable to interrupt the High-voltage DC fault current where a large-capacity capacitor is required to interrupt the DC current. The active resonant circuit composing of a pre-charged capacitor with a reactor and a thyristor switch /triggering gap imposes a high frequency (several khz) inverse current on the interrupting fault and normal current and creates a current zero instantly. The scheme can typically interrupt DC fault and nominal current within 8-1 milliseconds. (d) Hybrid power electronic switch This switch is composed of mechanical switches and semiconductor devices. The scheme commutates the DC fault current to series and parallel connected power electronic devices which can block the current within a few milliseconds. This hybrid scheme can interrupt DC fault current very rapidly, but this new technology has not yet been demonstrated in the field and might not be the best technoeconomical solution from a capital Expenditure (CAPEX) and losses point of view especially for HVDC applications. [4], [5] 1

Figure 1. DC circuit breakers with different interrupting schemes The requirement for a DC circuit breaker which can clear DC fault current as well as meet the required fault clearing time was investigated with a four-terminal radial HVDC grid models. The results show that DC fault current is less than 16 ka at 1 milliseconds after a fault occurrence. The time for the DC voltage to reach 8 % of the system voltage (+/-32 kv) is about 1 milliseconds with a cable system, when the series DC reactor connected to lines is 3 mh. The fault clearing time evaluated with a four-terminal HVDC grid model suggests that a mechanical DC circuit breaker with a forced current zero formation scheme, could be applied for HVDC grid line protection. For its demonstration, a DC circuit breaker with forced current zero formation was used as a prototype for testing. This DC circuit breaker successfully interrupted a current equivalent of up to 16 ka DC in the factory laboratory. The prototype comprises of a high-voltage AC vacuum circuit breaker at transmission voltages connected to an external capacitor equipped with a triggering gap. A series of interruption tests performed on this breaker verified the clearance of short circuit currents as high as 16 ka DC within a few milliseconds after an opening command. This paper describes the prototype design of the mechanical DC circuit breaker employed with the forced current zero formation scheme and its interrupting performance in detail. 2. DCCB requirements for multi-terminal HVDC grid The requirements for DCCB such as DC fault current level and DC fault clearing time are investigated with a multi-terminal radial HVDC network model shown in Figure 2. This model consists of a fourterminal HVDC network with four VSC stations connected via DC as shown in Figure 2 The lengths of each cable system were set to 12 km, 24 km and 36 km, similar to the radial UHV AC network that was used to evaluate the circuit breaker requirements. [6] The capacities of each VSC converter stations (C/S) range from 9MW to 12MW, and the transmission capacity of the system is 2.1GW. In the analysis, a DC pole to pole fault is considered near B-C/S. 2

Pole to pole fault B-C/S DCL If : Fault current at the most severe point If Cable 24km A-C/S Cable 36km +/- 32kV VDC C-C/S Cable 12km VDC : DC voltage at converter D-C/S Figure 2. Multi-terminal radial HVDC network model Depending on converter design parameters, a VSC converter cannot continue operation when the DC system voltage typically drops below 8% of the nominal voltage depending on the design parameter (e.g. modulation index). Therefore, the DCCB is required to clear a fault rapidly in order to continue power transmission on a healthy line, before the system voltage drops to.8 PU due to the impact of a fault that has occurred on a remote line. The time for the system voltage to drop to.8 PU due to a remote fault can be protracted by inserting a series connected reactor (DCL) to the DC lines. Figure 3 shows some analytical results of the DC voltage V DC (the pole to pole voltage shown in Figure 2) at C/S for various DCL reactor values when a pole to pole fault occurs near B-C/S. The voltage at B-C/S near immediately drops at the instance of a fault in a rate of decay of voltage determined by the line impedance and DCL reactor. The voltage at C-C/S, D-C/S and A-C/S located 24 km to 6 km away from the fault location gradually drops after fault occurrence, but the rate of decay is not as severe due to impedance increase with the larger reactance of DCL reactor and transmission lengths as well as travelling wave phenomenon from longer propagation distance from the fault location. Simulations show that by increasing the reactance of the line and having longer distances from the fault location the voltage drop at a remote converter can be mitigated therefore allowing a longer DC fault clearing time threshold for the DCCB. Table 1 summarizes the results of the simulations showing fault clearing times for DCCB, which is set that the converter DC voltage not to drop below.8 PU of the system voltage after a fault occurrence, while varying the value of the DCL reactor at each C/S. Although it doesn t indicate a perfect correlation between the speed of the voltage drop and distance from the fault due to transient oscillation and system parameter differences of each C/S (e.g. converter capacity), but DC voltage tends to drop slowly with longer distance from the fault. The result indicates that the DC fault clearing time could be longer than 1 milliseconds when a larger DCL reactor in the range of 3 mh or more is connected to a main circuit in series. 3

(a) B-C/S (near the fault) (b) C-C/S (24km from the fault) (c) D-C/S (36km from the fault) (d) A-C/S (6km from the fault) Figure 3. DC Voltage behaviour at each C/S after a fault occurrence Table 1. DC fault clearing times for DCCB for various DCL reactance values at each C/S Another important requirement for DCCBs is DC fault current, which increases with elapsed time after fault occurs depending on the total capacity of associated converters. In Figure 2 the fault current (I f ) through the cable connected to B-C/S is the most severe case, because the fault currents from three converters of A, C and D-C/S flow into the fault location. Figure 4 shows the DC fault current behaviour of I f for various DCL reactor values in the four-terminal HVDC network. When a fault occurs the connected poles immediately discharge at the fault and thus the fault current is in the range of 12 to 15 ka. Then the discharged current oscillates with a resonant frequency determined by the cable impedance. The fault current continues to increase up to 3 ka due to the fault currents flowing from the remote converters located at A, C and D-C/S. The simulation shows that the DC fault current is 15 ka for 3 mh DCL reactor and 23 ka for 1 mh DCL reactor after 1 milliseconds from the occurrence of the fault. 4

Figure 4. DC fault current behaviour of I DC for various DCL reactance values These analytical results indicate that the requirements for DCCB in the four-terminal +/-32 kv radial HVDC network model with 3 mh of DCL are typically less than 16 ka to be cleared within 1 milliseconds in order to continue power transmission at the remote converter station located 24 km away from fault location. The requirements make it feasible to apply a mechanical DCCB with the forced current zero formation scheme to HVDC grid line protection. 3. Interruption performance of mechanical DCCB with the forced current zero formation Interruption performance with interrupting currents up to 16 ka was evaluated using a mechanical DCCB composed of HV vacuum interrupter with an external capacitor. A forced current zero formation scheme was applied to create a current zero by superimposing high frequency inverse current on the DC fault current due to a pre-charged capacitor discharge connected in parallel to the interrupter. Figure 5 shows a schematic test circuit of a DCCB and the laboratory test circuit. This DCCB is composed of a high-voltage vacuum circuit breaker (VCB) and an external capacitor used to inject a high frequency (several khz) inverse current essential to create a current zero instantly after current injection. The active resonant circuit consists of a capacitor (C p ), a reactor (L p ) and a spark gap, and metal oxide varistor (MOV) which are connected in parallel to the C p. For the DCCB interruption tests, the discharge time of the pre-charged C p kept at a constant applied voltage had only a few milliseconds delay after the contact separation of the VCB interrupter. The active resonant discharge created a current zero by superimposing a high frequency inverse current injected by series connected C p and L p. The interrupting current was supplied by an AC current source, which can provide an equivalent DC current when the DCCB interrupts a power frequency short circuit peak current. As shown in Figure 6, the rate of decay of the interrupting current at the current zero has changed when varying the DC interrupting current since the capacitance (C p ) and the reactance (L p ) were kept constant throughout these tests. Testing conditions were determined in accordance with the dielectric requirements for a high voltage AC circuit breaker and the DC interrupting currents ranged from.5 ka (corresponding to the nominal current) up to 16 ka (corresponding to the maximum level of the short circuit current on the multiterminal radial HVDC network model). 5

DCCB Active resonant circuit Cp L p Gap DC Current Source Auxiliary Breaker MOV VCB Interrupter unit V I Figure 5. Testing configuration of DC circuit breaker Current di/dt at current zero in case of small current interruption di/dt at current zero in case of large current interruption time Figure 6. Interrupting currents across the interrupter unit corresponding to fault current and nominal current interruptions Figure 7 shows whole test sequence waveforms and their magnified waveforms recorded during interruption tests on the DCCB when interrupting currents of 16 ka, 5 ka and.5 ka respectively. Tests show that the DCCB can successfully interrupt the first current zero created by an injected current when interrupting currents of 16 ka and 5 ka. In case of.5 ka interruption, DCCB can interrupt this current after crossing current zero several times, where these di/dt exceed the interruption capability of the VCB, because the discharged inverse current creates a steep di/dt at the current zero due to smaller DC interrupting current. However, the nominal current interruption is categorized as a control operation but not a protective operation for fault clearing so it can be acceptable to interrupt the nominal current with a millisecond delay. 6

The rate of rise of the recovery voltage given by L p di becomes more severe for smaller interrupting dt currents. The overvoltage generated after interruption is determined by the following equation. Vp = k Ls I Cp Where, Ls is the inductance of source circuit, Cp is the capacitor connected in parallel to the interrupter unit, I is the breaking current and k (<1) is a damping factor caused by the component of the resistance of the circuit. Therefore, overvoltage (Vp) becomes higher when the breaking current I is large, but it is limited by the restriction voltage of the metal oxide varistor (MOV) connected in parallel to Cp. Since the overvoltage Vp becomes smaller when the breaking current I is small, voltage between interrupter contacts under the condition of breaking current.5 ka was less than the restriction level of the MOV. 2 2 1 1-1 -1 15 15-15 -15 (1) Waveforms of whole test sequence (2) Magnified waveform in the vicinity of current zero Current [ka] 2 1-1 Voltage [kv] Voltage [kv] Current [ka] Figure 7. (a) Voltage and current behaviours during DC 16 ka interruption 15 2 1-1 15-15 -15 (1) Waveforms of whole test sequence (2) Magnified waveform in the vicinity of current zero Figure 7. (b) Voltage and current behaviours during DC 5 ka interruption 7

Current [ka] 2 1-1 Current [ka] 2 1-1 Voltage [kv] 15-15 Voltage [kv] 15-15 (1) Waveforms of whole test sequence (2) Magnified waveform in the vicinity of current zero Figure 7. (c) Voltage and current behaviours during DC.5 ka interruption 4. Conclusions The requirements for the DCCB s optimal operation were evaluated using a four-terminal +/-32 kv radial HVDC network model. By inserting DCL reactors in the range of 3 mh into the network model and upon simulating pole to pole fault, 1) the short circuit current levels where limited to values less than 16 ka and 2) the DC fault clearing times where longer than 1 milliseconds, while maintaining power transmission at a remote converter station located 24 km away from fault location. These two requirements make it feasible to apply a mechanical DCCB with the forced current zero formation scheme for HVDC grid line protection. The DCCB equipped with the forced current zero formation scheme, composed of HV-vacuum interrupter and an active resonant circuit was tested to interrupt an equivalent current of up to DC 16 ka in the factory laboratory. The DCCB has been successfully verified to clear DC fault currents of 16 ka as well as typical DC normal current of.5 ka within a few milliseconds after the contact separation of the interrupter unit. BIBLIOGRAPHY [1] A. Lee et al., Arc-circuit instability: HVDC circuit breaker concept based on SF6 puffer technology, IEE GD-82, pp.116-119 [2] H. Ito et al., Instability of DC Arc in SF6 circuit breaker, IEEE transactions on Power Delivery, Vol.12, No.4, pp.158-1513, 1997 [3] S. Hara et al., Fault protection of metallic return circuit of Kii channel HVDC system, IEE GD- 95, pp.132-137 [4] CIGRE WG B4.52, HVDC grid feasibility study, Appendix H: Switching DC in an HVDC system, Technical Brochure 533, 213 [5] M. Callavik et al., Hybrid HVDC breaker, ABB grid systems, Technical paper, Nov. 212 [6] CIGRE WG A3.28, Switching phenomena for EHV and UHV equipment, CIGRE Technical Brochure 57, February 214 8