Drinking water monitoring

Similar documents
WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Measuring and Controlling Unit Multronic

Conductivity measurement

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Measuring and Controlling Unit Multronic OC

TARAline CS4. Data Sheet

Conex DIA-1, -2, -2Q. Measuring amplifiers and controllers, preassembled systems. One or two parameters (Cl 2, ClO 2, O 3, H 2 O 2, PAA, ph, ORP)

GRUNDFOS ALLDOS DATA BOOKLET DIP. Measuring amplifiers and controllers Preassembled systems 50/60 Hz

ph or ORP Transmitter

Technical Information Memosens CCS50D

OPTISYS CL 1100 Technical Datasheet

Condumax CLS21 and CLS21D

Metal Finishing. W600 Series Controllers. Summary of Key Benefits

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-PR, DIS-D. Measuring amplifiers and controllers Preassembled systems 50/60 Hz

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

ProMinent D1Cb and D1Cc Analyzers

Digital conductivity transmitter

Conductivity Analyzer

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

dtrans Az 01 µp Indicator/Controller for analytical measurement

WALLACE & TIERNAN MULTI-FUNCTION-CONTROLLER MFC from version V:2.00

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

OPTISENS PH ph sensor. Technical Datasheet

Analytical Transmitters

Contents. Publisher. Contents. page. Publisher 1. New Instruments 2 7. MultiLine IDS General Description of Meters 16 21

OPTISENS PH 8100 Technical Datasheet

inolab Multi IDS ph, ISE, CONDUCTIVITY AND DISSOLVED OXYGEN MEASUREMENT ACCURATE, COMPLIANT, SECURE

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Conductivity. Handheld conductivity meters

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

OPTISENS ORP 8590 Technical Datasheet

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

Technical Information Condumax CLS21D/CLS21

MaxxFlow HTC Flow measurement for dry bulk solids

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

DUAL-INPUT INTELLIGENT ANALYZER

Condumax CLS21 and CLS21D

Rosemount TM 498CL ph-independent Free Chlorine Sensor

B Operating Instructions /

Liquid and gas analyzers

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

OPTISENS CL 1100 Technical Datasheet

Inductive conductivity transmitter JUMO CTI-Junior

Condumax CLS15 and CLS15D

Conductivity Transmitter

Technical Information Orbipore CPS91D and CPS91

Handheld meter Cond 3150i

TARAsens AS2 / AS3. Data Sheet. indicator

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Analog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V

Analog outputs (option) Outputs 1 + 2: 0(4) - 20 ma or 0-10 V

B Operating Instructions V1.00/EN/

Memosens CPS96D. Technical Information

ABB ph/orp analyzer and probe package

Instruction Manual 19 Measuring System

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

Chlorine / Chlorine Dioxide Measurement liquisys M CCM 223 / 253

Example: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring range of 5 ppm. Ambient temperature: C

Conductivity Transmitter N-LF V AC

dtrans Lf 01 µp transmitter / controller for electrolytic conductivity

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

DUAL-INPUT INTELLIGENT ANALYZER

Technical Information Liquisys M CCM223/253

Conductivity sensor for hygienic applications

ecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type B Operating Instructions 02.07/

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Multi-electrode Conductivity Analyzers

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

OPTISENS PH 8390 Technical Datasheet

FAST SAMPLING CONVERTER

Multi-parameter measurement

TARAtec P9. Data Sheet

Condumax W CLS15 and CLS15D

Liquisys M CCM223/253

4-20mA, 0-10V and general process measuring bargraph displays

Liquisys M CCM223/253

Technical Information Smartec CLD18

Ceramax CPS341D. Technical Information

SMARTPAT COND 1200 Technical Datasheet

The transducer component converts the measured signal and displays the actual value.

Conductivity measurement SmarTec S CLD 132

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters

Features and Applications

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

Bedienungsanleitung Operating manual Mode d emploi Instrucciones de operación

LST400 Ultrasonic level / open channel flow transmitter

COND 200. Conductivity/TDS/Salinity Meter Operating instructions. Meas Cal. Hold Rcl Store. On Off Menu

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Technical Information Condumax CLS15D/CLS15

Transcription:

Drinking water monitoring Ready-to-use systems for monitoring of quality relevant parameters in drinking water Pre-assembled Ready for use Flexible and multi-purpose

Single-parameter Systems Single-parameter systems Single-parameter systems for measurement of ph, D.O., conductivity, free and total chlorine Completely pre-mounted on panel No reagent consumption Integrated PID control function Transmitter High industrial WTW standard Protection class IP 66 Galvanically isolated ma outputs Electrode with flow-through armature Sensor and flow-through armature are perfectly matched according to the parameter Flow control monitoring (optional) Monitoring of continuous flow Alarm signal handling via transmitter output Dosing valve Adjustment of flow 2 Pressure reducer Pre-adjustment of pressure 0 6 bar

ph 5000 Ready-to-use system pre-mounted on a panel consisting of ph transmitter, ph electrode, flow-through cell and tubing Special electrode for drinking water Low maintenance Transmitter with PID control function Oxi 4000 Ready-to-use system, pre-mounted on a panel, consisting of D.O. transmitter, D.O. electrode, flow-through cell and tubing Low maintenance Wide measuring range (0 20 ppm) High resolution (± 0.0 ppm) LF 6000 Ready-to-use system pre-mounted on a panel consisting of conductivity transmitter, conductivity cell, flowthrough armature and tubing 2-electrode graphite cell Integrated temperature measurement Wide measuring range: (0 200 ms/cm) Cl 700 Ready-to-use system pre-mounted on a panel consisting of Cl transmitter, special electrodes for free and total chlorine, flow-through cell and tubing Membrane covered sensors No reagent consumption Pre-mounted systems Ready-to-use systems mounted on a panel. All components are optimized for drinking water applications in order to get most accurate readings and guarantee low maintenance. 3

Multi-parameter System MULTILINE 000 Multi-paramter system for measurement of ph, D.O. conductivity, turbidity, free and total chlorine Intuitive menu navigation Excellent cost/performance ratio No chemical consumables needed Calibration console Multi-parameter transmitter PVC mounting plate, approx. 00 x 75 x.2 cm (H x W x D) Measuring transmitter for flow measurement Chlorine measuring sensor ph electrode Conductivity cell ORP electrode Turbidimeter Flow-through armature Pressure reducer Flow measuring unit Dosing valve to adjust the flow Inlet Outlet Constant flow: flow measurement The flow measurement is used to control the optimal incident flow for a continuous operation. Flow measuring unit 4

Everything at a glance: MULTILINE 000 With up to 6 individually configurable measuring channels, plus 4 virtual channels, the MULTILINE 000 terminal is a very flexible measuring system for drinking water analysis. The system is pre-assembled on a wall mounting panel for immediate use. Just connect the power and sample flow ready. Digital interface (RS 232/RS 422/RS 485) 4 x 0/4 20mA outputs 4 x potential-free relays for limit value/alarm function (timer function programmable) Metal housing, protection class IP 65 Large backlit display with touch screen Pre-mounted The MULTILINE 000 is the only complete system to offer convenient measuring and display of up to six parameters with one single terminal. It is very easy to operate thanks to a touchscreen and a intuitive menu. The monitoring system comes premounted on a panel and is ready to use. Flow-through armature Sensor Correctly dosed: chlorine measurement For disinfection monitoring, three amperometric types of chlorine electrodes are available. Free chlorine: The FCML 42 is suitable for measurements with changing ph values (ph 4 2, ph compensation integrated in the sensor). Free chlorine: The FCML 68 is suitable for measurements with a relatively constant ph value of approx. ph 7. *) For total chlorine, the TCML is available. All measuring cells are supplied with the D-Cl flow-through armature. *) If the ph value is measured simultaneously, the measured value can be ph-compensated via the MULTILINE 000. High precision measurement: ph, Cond, ORP Electrodes Flow-through armature The flow-through armature has three slots for 3.5 screw threads. Integrated in the screw coupling, all three built-in sensors can be removed together and thus be rapidly and easily calibrated or serviced with the aid of the calibration console. SenTix ML 70 combination electrode ph combination electrode optimized for drinking water, with gel electrolyte and S7 plug connector LR ML conductivity cell Very robust synthetic two electrode cell with a large measuring range of 0. to 20 ms SenTix ML ORP combination electrode ORP combination electrode for exact ORP measurement 5

Turbidity Measurement Turb 2000 Turb 220 Simple calibration Integrated bubble trap Ultrasonic cleaning of cuvette The nephelometric measurement is offered with or without ultrasonic cleaning of the flow-through cuvette. The user can also select between infrared light measurement according to DIN 7027 and white light measurement according to US EPA 80.. Measuring range 0 000 NTU Resolution selectable up to 0.000 Accuracy Outputs Power supply Technical Data Turb 2000 ± 2% of the measured value or ± 0.02 NTU below 40 NTU (the higher value), ± 5% of the measured value above 40 NTU RS 485 or 4 20 ma 00 240 VAC, 47 63 Hz Analyzer for Free and Total Chlorine Chlorine 3000 Low consumption of reagents 30 days maintenance-free operation Excellent cost/performance ratio The analyzer operates photometrical with the DPD method according to US EPA. The reagents are supplied in dry state. For an operation of 30 days it is only necessary to fill them up with water. Technical Data Chlorine 3000 Measuring range 0 0 mg/l Resolution 0,0 mg/l Accuracy ± 0,03 mg/l or 5% (up to 6 mg/l; the higher value) Outputs RS 485 and 4 20 ma Power supply 00 240 VAC, 47 63 Hz 6

Technical Data Single-parameter systems mounting panels Multi-parameter systems mounting panels Dimensions (H x W x D): approx. 00 x 350 x 3 mm approx. 000 x 750 x 3 mm Temperature operation 0 C + 40 C, storage 0 C + 40 C operation 0 C + 40 C, storage 0 C + 40 C Allowable overpressure Flow control before dosing valve (inlet): 0 0 bar, after dosing valve 0 6 bar, according to sensor flow-through measurement (optional), threshold: approx. 30 l/h (0.5 l/min) before dosing valve (inlet): 0 0 bar, after dosing valve 0 6 bar, according to sensor flow-through measurement (optional), Outlet fixed pipe joint (DN 0), pressureless. gravity flow to spout, Ø 40 mm PVC pipe Single-parameter systems (ph 5000, Oxi 4000, LF 6000 and Cl 700) Designation, parameter ph 5000 (ph) Oxi 4000 (D.O.) LF 6000 (conductivity) Cl 700 (chlorine) Measuring range 0.00 4.00 0.00 20.00 mg/l 0 99.9 ms/cm, 0.0 200.0 % O 2 automatic range selection, adjustable Resolution 0.0 0.0 mg/l / 0.% dependig on range 0. µs/cm 0. ms/cm 0.00 2.00 or 0.0 20.0 mg/l, adjustable 0.0 or 0. mg/l, dependig on range Accuracy ± 0.0 ±digit ± 0.0 ±digit 0.5% of value ± digit ± 0.5% of value Temperature measurement Temperature compensation Contact outputs *) Analogue outputs *) Digital interface *) Temperature limitations Dimensions, weights Warranty Protection class IP 66 TFK 5000 (Pt000), automatic via connected temperature sensor or by manual input Pt 000 (integrated), automatic Pt 000 (integrated), linear with adjustable temperature coefficient or non-linear TFK 5000 (Pt000), 20 +30 C automatic, integrated in sensor 2 programmable relays (threshold, hysteresis), 250 V, switching current 5 A, Ohm resistive load 50 W 2 programmable current outputs, 0/4 20mA, galvanically separated, recorder range and recorder attenuation settable via software, PID controller RS 485 interface, Bus operation with up to 3 units possible operation 25 +55 C ( 3 + 3 F), storage 25 + 65 C ( 3 + 49 F) 222 x 202 x 05 mm (W x H x D), approx. 2.2 kg (terminal only) 3 years according to 0 AGB Multi-parameter system MULTILINE 000 Parameter ph D.O. Conductivity Chlorine Measuring range 0.00 4.00 0.00 20.00 mg/l 0 00 ms/cm, 0.0 200.0 % O 2 automatic range selection, adjustable Resolution 0.0 0.0 mg/l / 0.% dependig on range 0. µs/cm 0. ms/cm Accuracy ± 0.0 ± digit ± 0.0 ± digit 0.5 % of measured value ± digit Temperature measurement Temperature compensation Contact outputs *) Analogue outputs *) Digital interface *) Temperature limitations Protection class IP 65 Dimensions, weights Warranty TFK 5000 (Pt000), automatic via connected temperature sensor or by manual input Pt 000 (integrated), automatic Pt 000 (integrated), linear with adjustable temperature coefficient or non-linear 0.00 2.00 mg/l 0.0 mg/l ± 0.5 % of measured value via another channel, depending on sensor automatic, integrated in sensor 4 programmable relays (threshold, hysteresis), 250 V, switching current 5 A, Ohm resistive load 50 W 4 programmable current outputs, 0/4 20mA, galvanically separated, recorder range and recorder attenuation settable via software, optional PID controller RS 485/232 or 422 (Modbus) operation 25 +55 C ( 3 + 3 F), storage 25 +65 C ( 3 + 49 F) 39 x 240 x 25 mm, approx. 5 kg (terminal only) 2 years according to 0 AGB *) According to the ordered model: Standard with current and relay output and PID controller, RT with 2 current and 2 relay outputs, RS additionally with RS485 output. Further details are given in the instruction manuals and on our homepage. 7

Ordering information Single-parameter systems Parameter Flow Control (FC) Outputs Voltage ph/orp (ph 5000) D.O. (Oxi 4000) 2 Cond (LF6000) 3 Chlorine (Cl 700) 5 with FC switch 0 without FC switch current output (0/4 20mA), relay 2 current outputs (0/4 20mA), 2 relays 2 2 current outputs (0/4 20mA), 2 relays, RS 485 interface 3 5 VAC 230 VAC 2 *) If an option is required, please enter the relevant number in the cell. If the option is not required, enter 0. Please order electrodes separately (except chlorine electrode with mit PG 3.5 thread), cf. price list drinking water 2008. Your order no.: *) 8 S- x x x x Controller/Terminal MULTILINE 000 drinking water monitoring system with flow measurement, pressure controller, dosing valve, premounted on water repellent panel. DN 0 joints with: MULTILINE 000 controller/terminal, 240 VAC 8T MULTILINE 000 controller/terminal, 5 VAC 8E MULTILINE 000 controller/terminal, additionally with flow measurement, 240 VAC 8F MULTILINE 000 controller/terminal, additionally with flow measurement, 5 VAC 8U Configurable parameters/inputs Conductivity measurement with integrated temperature sensor (LR ML) (input module, Two electrodes conductivity cell (0. 20 ms/cm), connection cable) ph measurement (SenTix ML 70) (input module, ph electrode for drinking water (ph 0 4), connection cable) ORP measurement (SenTix ML ORP) (input module, Redox-Messkette, connection cable) Chlorine measurement (amperometric) Option.) Free chlorine amperometric, little ph dependent (ph 4 9) (FCML 42) input module, sensor (0 2 mg/l), flow-through armature, cable Option 2.) Free chlorine (ph 6 8), compensable via ph measurement (FCML 68) input module, sensor (0 2 mg/l), flow-through armature, cable 2 Option 3.) Chlor total amperometric (TC ML) input module, sensor (0 2 mg/l), flow-through armature, cable 3 Independent measured parameter, turbidity (4 options) with own display Option.) Turb 2000, white light, no ultrasonic cleaning Option 2.) Turb 2020 white light, with ultrasonic cleaning 2 Option 3.) Turb 200 infrared light, no ultrasonic cleaning 3 Option 4.) Turb 220 infrared light, with ultrasonic cleaning 4 Your order no.: *) *) If an option is required, please enter the relevant number in the cell. If the option is not required, enter 0. Chlorine analyzer and turbidimeter Model Designation Order no. Chlorine 3000 Chlorine analyzer for determination of free and total chlorine 86050 Turb 220 Turbidity measuring instrument for online determination of turbidity in flow-through, with nephelometric infrared measurement and ultrasonic cuvette cleaning. More variants on request. 600035 99908US WTW Wissenschaftlich-Technische Werkstätten GmbH, Dr.-Karl-Slevogt-Straße, D-82362 Weil heim Telefon: +49 (0)88 83-0 Fax: +49 (0)88 83-420 E-Mail: info@wtw.com In ter net: http://www.wtw.com 4/2009 by WTW GmbH WTW, a Nova Analytics company