Examination of Pipe Welds by Image Plate Based Computed Radiography System

Similar documents
Computed Radiography of Resistance Temperature Sensor for Indian PHWR

10/26/2015. Study Harder

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Radiographic Testing (RT) [10]

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

10/3/2012. Study Harder

The HOIS recommended practice for in-service computed radiography of pipes

Acquisition, Processing and Display

ON THE WAY TO DIGITAL RADIOGRAPHY

Amorphous Selenium Direct Radiography for Industrial Imaging

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

CR Basics and FAQ. Overview. Historical Perspective

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY

Gamex CR 2.0 Program description and operating manual

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

RADIOGRAPHIC EXPOSURE

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Introduction To NDT. BY: Omid HEIDARY

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

CARESTREAM INDUSTREX Digital Imaging Plates

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

Dental Radiography. One of the problems of dental radiography is having different dimensions than normal.

Seminar 8. Radiology S8 1

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

CARESTREAM INDUSTREX Digital Imaging Plates

Setting up digital imaging department!

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Real Time Linear Array Imaging. Brian Caccamise

Digital Imaging Considerations Computed Radiography

Film Replacement in Radiographic Weld Inspection The New ISO Standard

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Pre Conference Workshop on Advanced Digital imaging

Hardware for High Energy Applications 30 October 2009

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

Fig.2: Scanner VistaScan for image plates

Advancements In Digital Radiography: CR, DR, and DICONDE

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

New Developments in Automated Inspection for Corrosion under Insulation

Radiographic testing: Increased detection sensitivity using optimum source to object distance

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Visibility of Detail

NDT-PRO Services expands service offering

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning

X-ray Tube and Generator Basic principles and construction

Advanced Digital Radiography for Field NDT

ISO INTERNATIONAL STANDARD

BASICS OF FLUOROSCOPY

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Advancements in Pipeline Girth Weld Inspection

Digital Radiography and its Advantages in Field NDT Inspections Today

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Computed Radiography

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

DIGITAL IMAGING Recognise the importance of quality assurance

NPTEL NPTEL ONLINE COURSE. NPTEL Online Certification Course (NOC) NPTEL. Theory and Practice of Non Destructive Testing

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Essentials of Digital Imaging

COMPUTED RADIOGRAPHY (CR)

Experiences of users in Digital Radiography

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

RADIOGRAPHY TERMS TO KNOW SELF STUDY DENTALELLE TUTORING

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Photomultiplier Tube

Photostimulable phosphor plates (PSPs)

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

9/10/2012. Computed Radiography Chapter 3 Physics and Technology. What is Computed Radiography?

X-RAY. Lecture No.4. Image Characteristics:

LECTURE 1 The Radiographic Image

Essentials of Digital Imaging

OPTIMIZATION OF SCANNING PARAMETERS OF COMPUTED RADIOGRAPHY FOR CHARACTERIZATION OF EXPANDED POLYSTYRENE

Film and processing quality assurance

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

X-rays in medical diagnostics

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

Ray Detection Digital Image Quality and Influential Factors

Digital Profile Radiography Practical uses and limitations

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

Digital Industrial Radiography

Transcription:

Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai 400085 Email: sanjoyd@barc.gov.in,sanjoy_95@rediffmail.com Abstract All engineering components are required to be tested to ensure reliable performance during its service life without premature failure. Sometime these materials are put into hostile condition such as in corrosive atmosphere, high temp. & pressure or in combination of both, which may reduce the service life of component. Hence these components must be subjected to several nondestructive tests (NDT) to ensure that the materials are free from defects or their dimensions are less than critical flaw size. Though conventional radiography is still used in the NDT industry, advanced technique such as digital radiography is being explored as an alternative to film radiography. Phosphor image plate based computed radiography is new addition in inspection field. As the radiation dose requirement is less in image plate, it may be used in combination with battery operated pulse x-ray machine for remote field application. The image produced by such system is available in digital format and can be processed by several image enhancement technique to extract more information. This paper is devoted to pipe weld inspection using image plate base computed radiography system and the use of several image enhancement operations for further evaluation. 1.0 Introduction: Conventional radiography technique produces two dimensional images of a object on a film, which is examined by using a film viewer. The image thus produced is permanent in nature which cannot be modified. The recent development in inspection technology is to digitize the inspection data which can be further processed to gain the additional information. Radiography is no longer an exception. Digital radiography produces a digital image on monitor rather than on a film. There are several ways to produce the digital radiograph. At present the available technologies in digital radiography are fluoroscopy system, linear detector array, flat panel detector and compute radiology system. Each system has it s own distinct operation principle. The selection of such system is determined by the several factors such as reliability, cost, maintenance and sensitivity. The operation of image plate base computer radiography(cr) system is similar to film radiography. In computed radiography, a special phosphor coated flexible image plate is exposed to radiation beam. Then the image plated is scanned in special

scanner to produce electronic image. This technique does not include any wet chemical processing, hence three is no associated chemical hazard. Also digital radiograph can be stored in wide variety of storage devices such as hard disc, CD, magnetic tape etc. 2.0 Computed Radiography Imaging System Computed radiography refers to conventional projection radiography, in which the image is acquired in digital format using an imaging plate rather than on film. The imaging plate looks very similar to fluoroscopy screen, but it works on different principle. The special phosphor of image plate interacts with radiation beams, absorbs and stored part of it s energy in it s structure, called electron-trap. After exposure, the image plate which contains latent image is scanned in a special scanner with the help of fine laser beam. The amount of photo stimulated luminescence(psl) received is proportional to amount of radiation energy stored in image plate. A photo multiplier tube(pmt) measures the light intensity, which is used to produce a digitized image. As the surface of the image plate is scanned by the fine laser beam, the light quanta emitted from each point from image plate is converted into digital values for each pixel and stored in the computer as a digital image. This process is described in figure 01. After completing the scanning, the image can be presented on monitor and can be evaluated by experts. A number of image processing operation can be performed on the digitize image for effective evaluation and quantification. Figure 01: Principle of operation of Inage Plate base CR System 3.0 Image Plate Characteristics

Image plate works on principle of Photo Stimulated Luminescence(PSL). When a radiation beam strikes image plate, some portion of energy is emitted as light spontaneously. This is called fluorescence and it is not used for image formation. Some portion of energy is absorbed and is stored in electron trap, which fades away slowly by the process of phosphorescence. This stored energy in image plate forms latent image. When such exposed plate is stimulated with laser beam, this energy is released in the form light, which can be used as signal. Very few material possesses such properties. The compounds that meet desired properties are alkali earth halides such as BaFBr.Eu 2+, BaSrBr. Eu 2+. During interaction with radiation, electron are excited from valence band to conduction band and finally settles in crystal defect, called electron traps. These electrons are stimulated with laser beam to return to valence band with the emission of light as explained in figure 02. This light is directed towards photo cathode, which emits a bunch of electrons. This electrons are amplified with help of dynodes and finally produce electronic signal. This signal is sampled and quantized. Thus signal data from different point of image plate are arranged in the form matrix to represent the digital image. After scanning the image plate, the residual image left in image plate, is erased with how power laser light before next use. Figure 02: Physical change in structure during exposure and photo stimulated luminescence of image plate. 4.0 Experimental In case of pipe radiography, a single-wall exposure technique is preferred for radiography whenever practical. But for many practical application, it is not possible to use a single-wall technique. In such cases, a double-wall technique is used. In double-wall technique, radiation passes through the both wall before reaching the film. If the dia. of pipe is more than 90 mm,

then weld close to film side is interpreted(dwsi). For pipe and for welds of OD. 90 mm or less, a technique may be used in which the radiation passes through both walls and the weld (material) in both walls is viewed for acceptance on the same radiograph(dwdi). An adequate number of exposures shall be made to ensure that the complete coverage has been obtained. In our laboratory, two different dia. pipe was used for pipe radiography. A carbon steel pipe of OD 100 mm and 10 mm thick is radiographed on image plate using DWSI technique. Also another set of SS pipe of OD 38 mm is exposed on image plate by using DWDI technique. 5.0 Image Processing Operations for pipe A digital radiograph is a two dimensional matrix of pixels, which is tiniest picture element. The intensity level of pixel can be quantized. For example, a 8 bit digitization process divide the complete intensity range into 2 8 steps, i.e. 256 contrast levels, ranging from dark black, i.e.0 gray value, to brightest level, i.e. 255 gray value. Industrial radiographs are of low contrast, unsharped images. Therefore it is recommended to use image processing technique to improve the quality of image. The image processing operation doest not increase the inherent image content, rather it manipulates the image to improve it s visibility. It suppresses irrelevant surrounding and focuses on structural feature of interest. In digital radiography, image processing is used to remove noises and for edge enhancement. The raw image of the 100 mm large dia. pipe, generated by CR system, lacks contrast and defect is not clearly visible. Therefore the image is processed with different image enhancement operations as shown in figure 03.A. The radiograph before and after image processing are shown in figure 03.B and figure 03.C respectively. Digital pipe radiograph(dwsi) obtained from Computed Radiography machine Brightness/ Contrast Adjustment Edge enhancement filter Final pipe radiograph Figure 03A: Algorithm for edge enhancement of pipe radiograph.

Figure 03.B: As received pipe radiograph obtained from CR system. Lack of Penetration Figure 03.C: Image enhanced pipe radiograph showing lack of penetration. Similarly in another case, image processing technique is used to remove image noises. Sometimes electronics noises interfere during operation of the computed radiography system. As a result, the image quality may be degraded. A digital radiograph for 38 mm OD small dia. pipe obtained using DWDI techniques, is shown in figure 04.B, which contains lot of impulse noises due to poor handling of equipment. Therefore the image is passed through low pass, i.e. median filter, filtering operations to remove such noise, refer figure 04.A. The image processed radiograph is shown in figure 04.C.

Digital pipe radiograph(dwdi) obtained from Computed Radiography machine Brightness/ Contrast Adjustment 3x3 Median low pass Filter Final pipe radiograph Figure 04A: Algorithm for noise removal of pipe radiograph. Figure 04.B: Noisy pipe radiograph. Undercut

Figure 04.C: Median filtered noise free radiograph. 6.0 Summary Computed Radiography uses image receptors with barium fluoro-halide screens that function quite differently from normal film radiograph. The quality of digital image obtained with computed radiography system is comparable to film radiograph. In addition, it offers digital image processing to enhance image quality. Though the film radiography is dominating in industry, the paradigm is shifting towards digital technology. Also the imaging plate technique continues to evolve in a direction towards better quality, reduced cost and a unified procedure for tomorrows industrial application. References 01. ASNT, Nondestructive Testing Handbook, third edition: Vol. 4, Radiographic Testing, Columbus,Ohio, American Society for Nondestructive Testing, 2002. 02. Das, Sanjoy, D.Mukherjee and B.K. Shah, Weld Testing by Image Plate Based Computer Radiography, Material Evaluation, Americans Society for Non-destructive Testing(ASNT), Columbus, USA, March-2012,Vol.70/issue3. 03. Sanjoy Das, D. Mukherjee and B.K.Shah, Advanced Digital Radiography Systems and Image Processing Operations in Radiography Inspection, Inspectioneering Journal, Vol.16/Issue6,2010,USA. 04. Sanjoy Das, D. Mukherjee and B.K. Shah, Application of High and Low Pass Filter in Radiographic Image Processing, CINDE Journal, Canada, Jan.-Feb. 2010.