Drop Cable Product Catalog

Similar documents
Detailed Specifications & Technical Data

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

COAX 101. Author: Rob Wessels. Vice President of Engineering

Detailed Specifications & Technical Data

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

Standard Lengths of. Code Ft. m

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Crestron Wire Product Guide

Industrial Automation & Control Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Detailed Specifications & Technical Data

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Communication, Control, and Industrial Cable

DataTwist 5 ScTP Cable

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry


Filled Solid ALPETH Cable

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Shielded Fire Alarm Cables

CIR (Crush & Impact Resistant) VFD Power Cable

GEXOL WORLD CLASS OIL & GAS CABLES


Detailed Specifications & Technical Data

Communication and Control Cable Pro Audio and Intercom Systems Unshielded

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

To offer our customer the highest quality Broadband products at a competitive price with efficient Delivery and Inventory.

14 AWG 2 AWG: 600 Volt

Canadian OSP Copper I-1. Table of Contents

Analog Multi-Pair Snake Cable

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

MHR-2 Two Conductor Mini High Resolution S-Video Cable

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

LTE high-performance coaxial cables (RG replacement)

* Peaks of 1.3mm MAX allowed only in a rate of 2% or less

Cross-Connect and Distribution Frame Wire 5

SMB Plug Connector Crimp/Solder Attachment for RG174, RG316, RG188, LMR-100, PE-B100, PE-C100, inch

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

Tru products are now under the Tru-Win brand from Winchester Interconnect.

RF Connectors Technical Data Sheet. Description Minimum Typical Maximum Units. Frequency Range DC 3 GHz VSWR 1.25:1 Operating Voltage (AC) 335 Vrms.

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

AEE. Canada. Australia

Information technology. Generic cabling systems, General requirements

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400

COPPER + LWL RAW CABLES

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

UNIRAIL D RS485 and BUS cables

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

TNC Male Right Angle Connector Crimp/ Solder Attachment for RG174, RG316, RG188, inch, PE-B100, PE-C100, LMR-100

Microwave Coax. w w w. t e m p f l e x. c o m ( ) M i l f o r d R d. S o u t h G r a f t o n, M A

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

SMA Male Connector Crimp/Solder Attachment for RG58, RG303, RG141, PE-C195, PE-P195, LMR-195, inch

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Contents. Category7 SSTP Solid Indoor Cable - Page 03

For tough, seaworthy wire

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

Connection technology for wireless communication systems

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Nexans Industrial Solutions PRODUCT CATALOG

Instrumentation Cables

WIRE&CABLE FILS&CÂBLES S I N C E

NETWORK CONNECTIVITY SYSTEMS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

RG58 Coaxial Cable: 2) Approval:

SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188 Gold Plated

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

N Male Connector Clamp/Solder Attachment for PE-C500, LMR-500

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A

N Male Connector Crimp/Solder Attachment For RG58

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

SMA Male QD Connector Crimp/Solder Attachment For RG142, RG223, RG400, RG55

EXCELLENT ELECTRICAL PERFORMANCES

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

MULTIMEDIA CABLE H6091ZHB

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Microphone and Musical Instrument Cable Overview

TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

EZ-200-NMH-D ok by tech Svcs

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Field Instrument Cable. Electrical Noise

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Cable Attachment Method (Shield/Contact) Size Length, in [mm] 0.98 [24.89] Width/Dia., in [mm] [9.53]. Weight, lbs [g] 0.02 [9.07] 3.

7/16 DIN Male Right Angle Connector Clamp/Solder Attachment for RG213, RG214, RG8, RG9, RG225, RG393, RG215

ADVANCED FLAT CABLE SOLUTIONS

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Transcription:

Drop Cable Product Catalog

Table of Contents Drop Cable Product Catalog The Basics of CommScope Drop Cable... 2, 3 Drop Cable Reel Dimensions...4 Drop Cable Packaging Information... 4, 5 Explanation of Drop Cable Construction Code...5 Minimum Purchasing Quantity...6 Freight Policy...6 Terms and Conditions...6 Cable Construction Illustrations...7 59 Series - Standard, Tri-Shield and Super-Shield Constructions... 8, 9 6 Series - Standard, Tri-Shield and Super-Shield Constructions... 10, 11 7 Series - Standard, Tri-Shield and Super-Shield Constructions... 12, 13 11 Series - Standard, Tri-Shield and Super-Shield Constructions... 14, 15 NEC Category Drop Cables Riser Series (CATVR)... 16, 17 Plenum Series (CATVP)... 18, 19 Headend Cables F59 HEC-2, F59 HEC/3-22... 20, 21 MultiReach TM Cables... 22, 23 Thank You......for your interest in CommScope drop cable products. You are the reason we are the world leader in coaxial cable. Our new catalog includes the products which you request most often. However, if you do not see the product that you need listed in this catalog, contact the sales representative in your area or contact our Customer Service Department at: 800 982 1708 828 324 2200 Fax: 828 328 3400 International Fax: 828 323 4989 1999 CommScope, Inc. of North Carolina.

The Basics of CommScope Coaxial DropCable...How it works and what you need It is a complete family of products serving a variety of applications, such as INDOOR, AERIAL, UNDERGROUND, and MULTIPURPOSE. Aerial Cable PVC jacket with integrated messenger. Order Size Shielding Jacket Color Packaging F6 60 BVM Black Reel F11 90 77TS (F6), TS (F11) SS Integrated Messenger Specs Size Messenger Minimum Breaking Diameter Strength of Messenger F6 0.051 in. 180 lbs. / 82Kgf F11 0.072 in. 365 lbs. / 166 Kgf The BASIC products are available in four shielding types to meet your specific needs. You will benefit by receiving CommScope quality products and unmatched customer service at low prices and improved availability. Orders for BASIC products can be made in small quantity (as little as 4Kft for F11 and 9Kft for F6). Limiting your purchases to the BASIC products will also simplify your purchasing and inventory control. In case you have a unique application that requires special cable, we will continue to offer the industry s broadest product line. Indoor Cable Flame retardant PVC jacket. Meets NEC Article 820 V Rating (UL listed). Available in two packaging options: Reel or CommPak box (F6 only) Available in two jacket colors: Black or Neutral. Order Size Shielding Jacket Color Packaging F6 60 BVV Black Reel F11 90 Neutral Box (F6 Only) 77TS (F6), TS (F11) SS Multipurpose Cable PVC jacket for use as a temporary drop or in various applications. Order Size Shielding Jacket Color Packaging F6 60 BV Black Reel F11 90 77TS (F6), TS (F11) SS Underground Cable Rugged PE jacket with floodant to prevent corrosion and moisture ingress if the jacket is damaged. Cable is printed with symbol to identify as telecommunications cable. Order Size Shielding Jacket Color Packaging F6 60 BEF Black Reel F11 90 77TS (F6), TS (F11) SS 2 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

Size Attenuation is primarily a function of cable size. Basic products are available in the two most widely used sizes, 6 and 11. 6 series cable will meet most of your needs. For longer drops, choose 11 due to the lower attenuation values. Basic products feature copper clad steel* center conductor and foam polyethylene dielectric. Attenuation (@ 68 F [20 C]) Frequency 6 Series 11 Series (MHz) db/100 ft db/100 m db/100 ft db/100 m 55 1.6 5.25.96 3.15 450 4.4 14.43 2.75 9.02 750 5.65 18.54 3.65 11.97 1000 6.55 21.49 4.35 14.27 Other Electrical and Mechanical Characteristics Impedance: 75 ohms Velocity of Propogation: 85% *F11 with integrated messenger features a copper clad aluminum center conductor. Shielding The minimum recommended shielding for drop cable is an inner shield of aluminum-polypropylene-aluminum laminated tape bonded to the dielectric and a 60 percent braid of 34 AWG bare aluminum braid wire. This level of shielding is adequate for most of your applications and meets SCTE requirements. Additional shielding is available to provide greater protection against signal ingress and egress. All Basic Products are available in 4 shielding options: Bonded tape + 60 percent braid Bonded tape + 90 percent braid Jacket High quality PVC with flame retardant for indoor applications. PVC for outdoor aerial applications. PE for underground applications to resist abrasion and cuts. Bonded tape + 77 percent braid (F6) + tape (TriShield) + 60 percent braid (F11) Bonded tape + 60 percent braid + tape + 40 percent braid (SuperShield) For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 3

Drop Cable Reel Dimensions T F D F = Flange Diameter D = Drum Diameter T = Traverse inside distance between flanges F x D x T Flange Drum Traverse Note: T is inside dimension, not overall width. Drop Cable Packaging Information 6 Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 12 x 4 x 12 30 x 10 x 30 27 36 x 36 x 44 91 x 91 x 112 Single Messenger 14½ x 4 x 11 37 x 10 x 28 27 44 x 44 x 41 112 x 112 x 104 Single Tri-Shield 12 x 4 x 12 30 x 10 x 30 27 36 x 36 x 44 91 x 91 x 112 Single Super-Shield 14½ x 4 x 11 37 x 10 x 28 27 44 x 44 x 41 112 x 112 x 104 11 Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 18 x 6 x 11 46 x 15 x 28 12 36 x 36 x 41 91 x 91 x 104 Single Messenger 22 x 6 x 11 56 x 15 x 28 12 44 x 44 x 41 112 x 112 x 104 Single Tri-Shield 18 x 6 x 11 46 x 15 x 28 12 36 x 36 x 41 91 x 91 x 104 Single Super-Shield 18 x 6 x 11 46 x 15 x 28 12 36 x 36 x 41 91 x 91 x 104 4 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

Drop Cable Packaging Information 59 Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 12 x 4 x 9 30 x 10 x 23 27 36 x 36 x 35 91 x 91 x 89 Single Messenger 14½ x 4 x 11 37 x 10 x 28 27 44 x 44 x 41 112 x 112 x 104 Single Tri-Shield 12 x 4 x 9 30 x 10 x 23 27 36 x 36 x 35 91 x 91 x 89 Single Super-Shield 12 x 4 x12 37 x 10 x 30 27 36 x 36 x 44 91 x 91 x 112 Dual 16 x 6 x 11 41 x 15 x 28 24 48 x 42 x 41 122 x 107 x 104 Dual Messenger 18 x 6 x 11 46 x 15 x 28 12 36 x 36 x 41 91 x 91 x 104 Dual Tri-Shield 16 x 6 x 11 41 x 15 x 28 24 48 x 42 x 41 122 x 107 x 104 Dual Super-Shield 18 x 6 x 11 46 x 15 x 28 12 36 x 36 x 41 91 x 91 x 104 7 Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 14½ x 4 x 11 37 x 10 x 28 27 44 x 44 x 41 112 x 112 x 104 Single Messenger 18 x 6 x 11 46 x 15 x 28 12 36 x 36 x 41 91 x 91 x 104 Single Tri-Shield 14½ x 4 x 11 37 x 10 x 28 27 44 x 44 x 41 112 x 112 x 104 Single Super-Shield 18 x 6 x 11 46 x 15 x 28 24 48 x 42 x 41 122 x 107 x 104 Dual 30 x 12 x 13 76 x 30 x 30 12 44 x 44 x 41 112 x 112 x 104 Explanation of Drop Cable Product Codes Prefix F = Gas Expanded Polyethylene Dielectric 2 = Dual Cable 59, 6 = Drop Cable Series 7, 11 F2-660BVM Foam Messenger Dual Cable Polyvinylchloride Jacket 6 Drop Cable Series Bonded % Braid Coverage F660BEF Foam Flooding Compound 6 Drop Cable Series Polyethylene Jacket Bonded % Braid Coverage F6SSVR Foam Riser 6 Drop Cable Series Polyvinylchloride Jacket Super-Shield Foam Dual Cable F2-660BV-BW BrightWire TM Polyvinylchloride Jacket 6 Drop Cable Series Bonded % Braid Coverage Suffix First two = Percentage of Braid Coverage digits e.g. 53, 60, 67, 90, 95 B = Bonded Foil E = Polyethylene Jacket V = Polyvinylchloride Jacket M = Messenger F = Flooded SS = Super-Shield TS = Tri-Shield BW= BrightWire TM APD= Amorphous Polypropylene Drop V = NEC CATV R = NEC CATVR CMH= CSA Flame Test FT-1 CMG= CSA Flame Test FT-4 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 5

Minimum Purchase Quantity BASIC Products Size Round and Messenger Reels Boxes F6 9 a 16 F11 4 N/A Basic Products available in SMALL Quantity Purchases. a Exception: Minimum reel quantity for F6SSVM is 8. OTHER Products CommScope offers a wide variety of products for your unique applications. Higher minimum quantity is required. Options available include custom print, jacket color, sequential marking, etc. Additional charges may apply for these features. Size Round and Messenger Dual Multi-Reach Reels Boxes Coils b Reels Only Reels Only F59 27 (9) 32 (16) 36 (12) 48 (12) 48 (12) F6 27 (9) c 32 (16) 36 (12) 48 (12) 48 (12) F11 24 (4) N/A N/A 48 (12) 48 (12) Example: The minimum order quantity for F6 is 27 reels (or 27,000 ft). For a quantity greater than 27, increments of 9 should be used (36, 45, 54, etc.). b Indicates the minimum number of coils per order. Actual footage per coil varies by product. c Exception: Minimum reel quantity for F6SSVM is 24 (8). Freight Policy Shipments of $5,000 or more are f.o.b. factory, freight allowed if destination is within the continental United States. Shipments of less than $5,000 are f.o.b. factory. Standard lengths are 1,000 feet (304.8 meters) plus or minus 10% for reels and CommPak boxes. Standard length per coil varies by product. Not more than 5% of each shipment shall be other than standard lengths, with no lengths shorter than 500 feet (152 meters) on 1,000 foot (304.8 meters) reels. Orders for custom print may receive lengths down to 300 feet. Method of shipment at discretion of shipper. Inspection and final acceptance shall be made at factory prior to shipment. Terms and Conditions On approved credit, net 30 days from date of invoice; 1.5% finance charge equivalent to 18% per annum will be added after due date. All orders subject to acceptance at factory and will be billed at price in effect at time of shipment. Prices, discounts, terms conditions and specifications are subject to change without notice. 6 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

Drop Cable Constructions Standard Shield Jacket Aluminum Braided Shield Center Conductor Flooded Dielectric Bonded Aluminum Foil Shield Flooding Compound Tri-Shield Additional Aluminum Foil Shield Super-Shield (Quad) Messengered Additional Aluminum Braided Shield Steel Messenger Dual Siamese Construction Dual Messengered For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 7

59 Series Drop Cable Descriptions Bonded Foil Standard Construction 67% BRAID Shipping Wt. F5967BV Bonded foil, 67% braid, PVC jacket. 28 F5967BVV Bonded foil, 67% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 28 F5967BVM Bonded foil, 67% braid, PVC jacket,.051 inch messenger. 43 F5967BEF Bonded foil, 67% braid, flooded for underground, PE jacket. 24 F2-5967BVV Dual cable, bonded foil, 67% braid, flame retardant PVC jacket. Meets NEC Article 820 V 60 Rating. (UL listed). 95% BRAID F5995BV Bonded foil, 95% braid, PVC jacket. 29 F5995BVV Bonded foil, 95% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 30 F5995BVM Bonded foil, 95% braid, PVC jacket,.051 inch messenger. 44 F5995BEF Bonded foil, 95% braid, flooded for underground, PE jacket. 26 Bonded Foil Tri-Shield Construction 67% BRAID Shipping Wt. F59TSV Bonded foil, 67% braid, non-bonded tape, PVC jacket. 29 F59TSVV Bonded foil, 67% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 29 F59TSVM Bonded foil, 67% braid, non-bonded tape, PVC jacket,.051 messenger. 43 F59TSEF Bonded foil, 67% braid, non-bonded tape, flooded for underground, PE jacket. 25 F2-59TSVV Dual cable, bonded foil, 67% braid, non-bonded tape, flame retardant PVC jacket. Meets Article 58 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 53% + 35% BRAID Shipping Wt. F59SSV Bonded foil, 53% braid, non-bonded tape, 35% braid, PVC jacket. 34 F59SSVV Bonded foil, 53% braid, non-bonded tape, 35% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F59SSVM Bonded foil, 53% braid, non-bonded tape, 35% braid, PVC jacket,.051 messenger. 49 F59SSEF Bonded foil, 53% braid, non-bonded tape, 35% braid, flooded for underground, PE jacket. 28 F2-59SSVV Dual cable, bonded foil, 53% braid, non-bonded tape, 35% braid, flame retardant PVC jacket. 72 Meets NEC Article 820 V Rating. (UL listed) 8 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

59 Series Drop Cable Specifications Standard Construction 20 gauge [0.032 in. (0.81 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.240 in. (6.10 mm). Physical Dimensions Component Standard Shield Tri-Shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter 0.032 0.81 0.032 0.81 0.032 0.81 Nominal Diameter Over Dielectric 0.144 3.66 0.144 3.66 0.144 3.66 Nominal Diameter Over First Shield (Tape) 0.151 3.84 0.151 3.84 0.151 3.84 Nominal Diameter Over Jacket 0.240 6.10 0.240 6.10 0.265 6.73 Nominal Jacket Wall Thickness 0.032 0.81 0.030 0.76 0.034 0.86 Nominal Diameter of Steel Messenger 0.051 (single) 1.30 0.051 (single) 1.30 0.051 (single) 1.30 0.072 (dual) 1.83 0.072 (dual) 1.83 0.072 (dual) 1.83 Mechanical Characteristics Minimum Breaking 0.051 180 lbs. 82kg f Strength of Messenger 0.072 365 lbs. 166kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (BW & APD) Many products are available with a choice of two corrosion resistant treatments. Contact our sales and marketing office for specific information. BrightWire TM is a dry, anti-corrosive treatment that chemically combines with metal components to form a protective shield against water and subsequent corrosion. (Exceeds the SCTE requirement for corrosion resistant cable.) APD is a non-flowing, amorphous polypropylene flooding compound. APD meets NEC Article 830 V Rating. (UL listed) Specify BrightWire or APD when ordering product: Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.86 2.82 55 / Channel 2 2.05 6.73 83 / Channel 6 2.45 8.04 187 / Channel 9 3.60 11.81 211 / Channel 13 3.80 12.47 250 4.10 13.45 300 4.45 14.60 350 4.80 15.75 400 5.10 16.73 450 5.40 17.72 500 5.70 18.70 550 5.95 19.52 600 6.20 20.34 750 6.97 22.87 865 7.52 24.67 1000 8.12 26.64 Specifications subject to change without notice. F5967BV-BW (BrightWire TM anti-corrosive treatment) F5967BV-APD (APD anti-corrosive treatment) For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 9

6 Series Drop Cable Descriptions Bonded Foil Standard Construction 60% BRAID Shipping Wt. F660BV Bonded foil, 60% braid, PVC jacket. 33 F660BVV Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F660BVM Bonded foil, 60% braid, PVC jacket,.051 inch messenger. 48 F660BEF Bonded foil, 60% braid, flooded for underground, PE jacket. 30 F2-660BVV Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. 71 (UL listed) F660BVV-APD Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 34 90% BRAID F690BV Bonded foil, 90% braid, PVC jacket. 34 F690BVV Bonded foil, 90% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F690BVM Bonded foil, 90% braid, PVC jacket,.051 inch messenger. 49 F690BEF Bonded foil, 90% braid, flooded for underground, PE jacket. 31 Dual cable, bonded foil, 90% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. 73 F2-690BVV (UL listed) Bonded Foil Tri-Shield Construction 60% BRAID Shipping Wt. F6TSV Bonded foil, 60% braid, non-bonded tape, PVC jacket. 34 F6TSVV Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F677TSVV Bonded foil, 77% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F6TSVM Bonded foil, 60% braid, non-bonded tape, PVC jacket,.051 messenger. 53 F6TSEF Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 36 F2-6TSVV Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article 820 V Rating. (UL listed) 68 F6TSVV-APD Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 32 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 60% + 42% BRAID Shipping Wt. F6SSV Bonded foil, 60% braid, non-bonded tape, 42% braid, PVC jacket. 44 F6SSVV Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 44 F6SSVM Bonded foil, 60% braid, non-bonded tape, 42% braid, PVC jacket,.051 messenger. 62 F6SSEF Bonded foil, 60% braid, non-bonded tape, 42% braid, flooded for underground, PE jacket. 38 F2-6SSVV F6SSVV-APD Dual cable, bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket. 87 Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket, amorphous 45 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 10 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

6 Series Drop Cable Specifications Standard Construction 18 gauge [0.040 in. (1.02 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.272 in. (6.91 mm). Physical Dimensions Component Standard Shield Tri-Shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter 0.040 1.02 0.040 1.02 0.040 1.02 Nominal Diameter Over Dielectric 0.180 4.57 0.180 4.57 0.180 4.57 Nominal Diameter Over First Shield (Tape) 0.187 4.75 0.187 4.75 0.187 4.75 Nominal Diameter Over Jacket 0.272 6.91 0.278 7.06 0.300 7.62 Nominal Jacket Wall Thickness 0.030 0.76 0.030 0.76 0.034 0.86 Nominal Diameter of Steel Messenger 0.051 (single) 1.30 0.051 (single) 1.30 0.051 (single) 1.30 0.072 (dual) 1.83 0.072 (dual) 1.83 0.072 (dual) 1.83 Mechanical Characteristics Minimum Breaking 0.051 180 lbs. 82kg f Strength of Messenger 0.072 365 lbs. 166kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (APD & CRD) Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information. Specifications subject to change without notice. Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.58 1.90 55 / Channel 2 1.60 5.25 83 / Channel 6 1.95 6.40 187 / Channel 9 2.85 9.35 211 / Channel 13 3.05 10.00 250 3.30 10.82 300 3.55 11.64 350 3.85 12.63 400 4.15 13.61 450 4.40 14.43 500 4.66 15.09 550 4.90 16.08 600 5.10 16.73 750 5.65 18.54 865 6.10 20.01 1000 6.55 21.49 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 11

7 Series Drop Cable Descriptions Bonded Foil Standard Construction 60% BRAID Shipping Wt. F760BV Bonded foil, 60% braid, PVC jacket. 58 F760BVV Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 58 F760BVM Bonded foil, 60% braid, PVC jacket,.072 inch messenger. 81 F760BEF Bonded foil, 60% braid, flooded for underground, PE jacket. 52 F2-760BVV F760BVV-APD Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating.118 (UL listed) Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding 58 compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Tri-Shield Construction 60% BRAID Shipping Wt. F7TSV Bonded foil, 60% braid, non-bonded tape, PVC jacket. 58 F7TSVV Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 58 820 V Rating. (UL listed) F7TSVM Bonded foil, 60% braid, non-bonded tape, PVC jacket,.072 messenger. 81 F7TSEF Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 52 F2-7TSVV F7TSVV-APD Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article 118 820 V Rating. (UL listed) Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 58 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 60% + 40% BRAID Shipping Wt. F7SSV Bonded foil, 60% braid, non-bonded tape, 40% braid, PVC jacket. 64 F7SSVM Bonded foil, 60% braid, non-bonded tape, 40% braid, PVC jacket,.072 messenger. 87 F7SSEF Bonded foil, 60% braid, non-bonded tape, 40% braid, flooded for underground, PE jacket. 56 F7SSVV F2-7SSVV F7SSVV-APD Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. Meets 65 NEC Article 820 V Rating. (UL listed) Dual cable, bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. 132 Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket, amorphous 65 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 12 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

7 Series Drop Cable Specifications Standard Construction 16 gauge [0.051 in. (1.29 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.318 in. (8.08 mm). Physical Dimensions Component Standard Shield Tri-shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter 0.051 1.30 0.051 1.30 0.051 1.30 Nominal Diameter Over Dielectric 0.225 5.72 0.225 5.72 0.225 5.72 Nominal Diameter Over First Shield (Tape) 0.232 5.89 0.232 5.89 0.232 5.89 Nominal Diameter Over Jacket 0.319 8.08 0.323 8.20 0.338 8.59 Nominal Jacket Wall Thickness 0.030 0.76 0.032 0.81 0.034 0.86 Nominal Diameter of Steel Messenger 0.072 (single) 1.83 0.072 (single) 1.83 0.072 (single) 1.83 0.109 (dual) 2.72 0.109 (dual) 2.72 0.109 (dual) 2.77 Mechanical Characteristics Minimum Breaking 0.072 365 lbs. 166kg f Strength of Messenger 0.109 1800 lbs. 818kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (APD & CRD) Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information. Specifications subject to change without notice. Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.47 1.54 55 / Channel 2 1.25 4.10 83 / Channel 6 1.50 4.92 187 / Channel 9 2.22 7.28 211 / Channel 13 2.36 7.74 250 2.56 8.40 300 2.82 9.25 350 3.05 10.01 400 3.27 10.73 450 3.46 11.35 500 3.67 12.04 550 3.85 12.63 600 4.05 13.28 750 4.57 14.99 865 4.93 16.17 1000 5.32 17.45 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 13

11 Series Drop Cable Descriptions Bonded Foil Standard Construction 60% BRAID Shipping Wt. F1160BV Bonded foil, 60% braid, PVC jacket. 73 F1160BVV Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 73 F1160BVM 14 guage copper clad aluminum, bonded foil, 60% braid, PVC jacket,.072 inch messenger. 88 F1160BEF Bonded foil, 60% braid, flooded for underground, PE jacket. 65 F2-1160BVV F1160BVV-APD Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 147 820 V Rating (UL listed) Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding 73 compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Tri-Shield Construction 60% BRAID Shipping Wt. F11TSV Bonded foil, 60% braid, non-bonded tape, PVC jacket. 73 F11TSVV F11TSVM Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 73 820 V Rating. (UL listed) 14 guage copper clad aluminum, bonded foil, 60% braid, non-bonded tape, PVC jacket, 88.072 inch messenger. F11TSEF Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 65 F2-11TSVV F11TSVV-APD Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article 147 820 V Rating. (UL listed) Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 73 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 60% + 40% BRAID Shipping Wt. F11SSV Bonded foil, 60% braid, non-bonded tape, 40% braid, PVC jacket. 77 F11SSVV Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. Meets 77 NEC Article 820 V Rating. (UL listed) F11SSVM 14 gauge copper clad aluminum, bonded foil, 60% braid, non-bonded tape, 40% braid, 91 PVC jacket,.072 inch messenger. F11SSEF Bonded foil, 60% braid, non-bonded tape, 40% braid, flooded for underground, PE jacket. 67 F2-11SSVM F11SSVV-APD 14 guage copper clad aluminum, dual cable, bonded foil, 60% braid, non-bonded tape, 207 40% braid, PVC jacket,.109 inch messenger. Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket, amorphous 77 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 14 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

11 Series Drop Cable Specifications Standard Construction 14 gauge [0.064 in. (1.63 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.395 in. (10.03 mm). Physical Dimensions Component Standard Shield Tri-Shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter 0.064 1.63 0.064 1.63 0.064 1.63 Nominal Diameter Over Dielectric 0.280 7.11 0.280 7.11 0.280 7.11 Nominal Diameter Over First Shield (Tape) 0.287 7.29 0.287 7.29 0.287 7.29 Nominal Diameter Over Jacket 0.395 10.03 0.395 10.03 0.405 10.29 Nominal Jacket Wall Thickness 0.042 1.07 0.039 0.99 0.037 0.94 Nominal Diameter of Steel Messenger 0.072 (single) 1.83 0.072 (single) 1.83 0.072 (single) 1.83 0.109 (dual) 2.77 0.109 (dual) 2.77 0.109 (dual) 2.77 Mechanical Characteristics Minimum Breaking 0.072 365 lbs. 166kg f Strength of Messenger 0.109 1800 lbs. 818kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (APD & CRD) Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information. Specifications subject to change without notice. Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.38 1.25 55 / Channel 2 0.96 3.15 83 / Channel 6 1.18 3.87 187 / Channel 9 1.75 5.74 211 / Channel 13 1.90 6.23 250 2.05 6.72 300 2.25 7.38 350 2.42 7.94 400 2.60 8.53 450 2.75 9.02 500 2.90 9.51 550 3.04 9.97 600 3.18 10.43 750 3.65 11.97 865 3.98 13.05 1000 4.35 14.27 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 15

NEC Riser Drop Cable Series Descriptions Flame Retardant PVC Jacket 59 Riser Series - CATVR Construction CodeProduct Description Shipping Wt. (Lbs.) /1000' F5967BVR Bonded tape, 67% braid, flame retardant PVC jacket. 29 F2-5967BVR Dual cable, bonded tape, 67% braid, flame retardant PVC jacket. 62 F5995BVR Bonded tape, 95% braid, flame retardant PVC jacket. 30 F59TSVR Bonded tape, 67% braid, flame retardant PVC jacket. 28 F59SSVR Bonded tape, 67% braid, non-bonded tape, 40% braid, flame retardant PVC 31 jacket. Meets NEC Article 820 Riser Rating (UL listed). 6 Riser Series - CATVR Construction CodeProduct Description Shipping Wt. (Lbs.) /1000' F660BVR Bonded tape, 60% braid, flame retardant PVC jacket. 30 F2-660BVR Dual cable, bonded tape, 60% braid, flame retardant PVC jacket. 66 F690BVR Bonded tape, 90% braid, flame retardant PVC jacket. 33 F6TSVR Bonded tape, 60% braid,non-bonded tape, flame retardant PVC jacket. 32 F6SSVR Bonded tape, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. 44 Meets NEC Article 820 Riser Rating (UL listed). 11 Riser Series - CATVR Shipping Wt. F1160BVR Bonded tape, 60% braid, flame retardant PVC jacket. 73 F11SSVR Bonded tape, 60% braid, non-bonded tape, 60% braid, flame retardant PVC jacket. 78 Meets NEC Article 820 Riser Rating (UL listed). 16 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

NEC Riser Drop Cable Specifications Standard Construction - 59 Riser Series 20 gauge [0.032 in. (0.81 mm)] copper covered steel center conductor; gas expanded polyethylene dielectirc; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of bare aluminum braid wire; jacket of flame retardant black polyvinylchloride. Nom. O.D. 0.240 in. (6.10 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter 0.032 0.81 0.032 0.81 Nominal Diameter Over Dielectric 0.144 3.66 0.144 3.66 Nominal Diameter Over First Shield (Tape) 0.151 3.84 0.151 3.84 Nominal Diameter Over Jacket 0.240 6.10 0.265 6.73 Nominal Jacket Wall Thickness 0.032 0.81 0.034 0.86 Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.86 2.86 55 2.05 6.73 83 2.45 8.04 187 3.60 11.81 211 3.80 12.47 250 4.10 13.45 300 4.45 14.60 350 4.80 15.75 400 5.10 16.73 450 5.40 17.72 500 5.70 18.70 550 5.95 19.52 600 6.20 20.34 750 6.97 22.87 865 7.52 24.67 1000 8.12 26.64 Standard Construction - 6 Riser Series 18 gauge [0.0359 in. (0.91 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of bare aluminum braid wire; jacket of flame retardant black polyvinylchloride. Nom. O.D. 0.272 in. (6.91 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter 0.040 1.02 0.040 1.02 Nominal Diameter Over Dielectric 0.180 4.57 0.180 4.57 Nominal Diameter Over First Shield (Tape) 0.187 4.75 0.187 4.75 Nominal Diameter Over Jacket 0.272 6.91 0.300 7.62 Nominal Jacket Wall Thickness 0.030 0.76 0.034 0.86 Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Attenuation [@ 68 F. (20 C.)] Frequency (MHz) Maximum (db/100 ft.) Maximum (db/100 m) 5 0.58 1.90 55 1.60 5.25 83 1.95 6.40 187 2.85 9.35 211 3.05 10.00 250 3.30 10.82 300 3.55 11.64 350 3.85 12.63 400 4.15 13.61 450 4.40 14.43 500 4.66 15.09 550 4.90 16.08 600 5.03 16.73 750 5.65 18.54 865 6.10 20.01 1000 6.55 21.49 Standard Construction - 11 Riser Series 14 gauge [0.064 in. (1.63 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of bare aluminum braid wire; jacket of flame retardant black polyvinylchloride. Nom. O.D. 0.395 in. (10.03 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter 0.064 1.63 0.064 1.63 Nominal Diameter Over Dielectric 0.280 7.11 0.280 7.11 Nominal Diameter Over First Shield (Tape) 0.287 7.29 0.287 7.29 Nominal Diameter Over Jacket 0.395 10.03 0.405 10.29 Nominal Jacket Wall Thickness 0.042 1.07 0.037 0.94 Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.38 1.25 55 0.96 3.15 83 1.18 3.87 187 1.75 5.74 211 1.90 6.23 250 2.05 6.76 300 2.25 7.38 350 2.42 7.94 400 2.60 8.53 450 2.75 9.02 500 2.90 9.51 550 3.04 9.97 600 3.18 10.43 750 3.65 11.97 865 3.98 13.05 1000 4.35 14.27 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 17

NEC Plenum Drop Cable Series Vinyl Jacket Kynar Jacket 59 Plenum Series - CATVP Shipping Wt. 2020K Basic construction, plenum rated jacket, 67% braid 26 2020V 2022K Basic construction, with additional non-braided laminated tape and braid shield, 26 2022V plenum rated jacket, 50% and 40% braid. Meets NEC Article 820 Plenum Rating (UL listed). 6 Plenum Series - CATVP Shipping Wt. 2275K Basic construction, plenum rated jacket, 60% braid. 31 2276V Basic construction, plenum rated jacket, 90% braid. 31 2227K Basic construction, with additional non-braided laminated tape and braid shield, 40 2227V plenum rated jacket, 2-60% braids. Meets NEC Article 820 Plenum Rating (UL listed). 11 Plenum Series - CATVP Shipping Wt. 2285K Basic construction, plenum rated jacket, 60% braid. 79 2287K Basic construction, with additional non-braided laminated tape and braid shield, 85 plenum rated jacket, 2-60% braids. Meets NEC Article 820 Plenum Rating (UL listed). 18 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

NEC Plenum Drop Cable Specifications Standard Construction - 59 Plenum Series 20 gauge [0.032 in. (0.81 mm)] copper covered steel center conductor; gas expanded Teflon dielectric (FEP); inner shield aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of plenum rated material. Nom. O.D. 0.202 in. (5.26 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter 0.032 0.81 0.032 0.81 Nominal Diameter Over Dielectric 0.135 3.63 0.135 3.43 Nominal Diameter Over First Shield (Tape) 0.141 3.84 0.141 3.58 Nominal Diameter Over Jacket 0.202 5.26 0.228 5.79 Nominal Jacket Wall Thickness 0.015 0.41 0.016 0.41 Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 1.34 1.12 10 1.07 3.51 50 1.84 6.04 100 2.50 8.20 200 3.53 11.58 400 5.35 17.55 700 7.07 23.19 900 8.02 26.31 1000 8.45 27.72 Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 84% Standard Construction - 6 Plenum Series 18 gauge [0.040 in. (1.02 mm)] copper covered steel center conductor; gas expanded Teflon dielectric (FEP); inner shield aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of plenum rated material. Nom. O.D. 0.237 in. (6.20 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter 0.040 1.02 0.040 1.02 Nominal Diameter Over Dielectric 0.170 4.57 0.180 4.57 Nominal Diameter Over First Shield (Tape) 0.176 4.75 0.187 4.75 Nominal Diameter Over Jacket 0.237 6.20 0.284 7.21 Nominal Jacket Wall Thickness 0.016 0.41 0.020 0.51 Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 1.25.82 10.71 2.33 50 1.47 4.82 100 2.01 6.59 200 2.82 8.59 400 4.13 13.55 700 5.85 19.19 900 6.87 22.53 1000 7.36 24.14 Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 84% Standard Construction - 11 Plenum Series 14 gauge [0.064 in. (1.45 mm)] copper covered steel center conductor; gas expanded Teflon dielectric (FEP); inner shield aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of plenum rated material. Nom. O.D. of 0.351 in. (8.92 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter 0.064 1.63 0.064 1.63 Nominal Diameter Over Dielectric 0.280 7.11 0.280 7.11 Nominal Diameter Over First Shield (Tape) 0.286 7.26 0.287 7.29 Nominal Diameter Over Jacket 0.351 8.92 0.372 9.45 Nominal Jacket Wall Thickness 0.020 0.51 0.020 0.51 Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 1.15.49 10.47 1.54 50 1.09 3.58 100 1.59 5.22 200 2.35 7.71 400 3.52 11.55 700 4.95 16.24 900 5.79 18.99 1000 6.19 20.30 Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 82% For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 19

Headend Drop Cable Series F59 HEC-2 Headend Cable F59 HEC-2 Headend Cable Basic Construction 20 gauge [Nominal 0.032 in. (0.81 mm)] silver plated copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; 34 AWG aluminum braid; aluminum-polypropylene-aluminum non-bonded tape; 34 AWG aluminum braid, jacket of black flame retardant polyvinylchloride meeting NEC Article 820 (UL listed), CATV category; Nominal O.D. 0.265 in. (6.73 mm). F59 HEC/3-22 Headend Cable F59 HEC/3-22 Headend Cable Basic Construction 20 gauge [Nominal 0.032 in. (0.81 mm)] silver plated copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-propylene-aluminum laminated tape with overlap bonded to dielectric; 34 AWG aluminum braid; 34 AWG aluminum braid; jacket of black flame retardant polyvinylchloride meeting NEC Article 820 (UL listed), CATV category; Nominal O.D. 0.265 in. (6.73 mm). Audio Pair: three 22 AWG bare copper, polyethylene insulation; 24 AWG tin-copper drain and polyester rip cord with aluminum shield on each pair; dual construction. 20 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

Headend Drop Cable Specifications Basic Construction Center Conductor 20 AWG (.032 in.) silver plated copper covered steel center conductor. Dielectric Gas expanded polyethylene. Shield 1. Bonded laminated aluminum tape. 2. 34 AWG aluminum braid, 95% coverage. 3. Laminated aluminum tape. 4. 34 AWG aluminum braid, 95% coverage. Jacket Flame retardant polyvinylchloride available in 12 colors: black, white, gray, green, brown, red, yellow, blue, orange, violet, aqua and rose. Audio Pair (F59 HEC/3-22 Only) Three Pair: 22 AWG (.0285 in.) bare copper Insulation: High density polyethylene. Drain: 24 AWG (.024 in.) tinned copper Ripcord: Polyester. Shielding: Aluminum (each pair). Identification: Color coding (std.): red/white, red/black, red/green. Reel: 14½ x 6 x 13. Length: 1000 ft. Cable Weight: 70 lbs./1000 ft. Electrical Characteristics Nominal Impedance 75 Ohms Capacitance 16.2 Velocity of Propogation 85% NOTE: Test reports are included on reels. Nominal Dimensions Conductor 0.032 inches... (0.81 mm) Dielectric 0.144 inches... (3.66 mm) Diameter Over 1st Shield 0.151 inches... (3.84 mm) Diameter Over 2nd Shield 0.180 inches... (4.57 mm) Diameter Over 3rd Shield 0.185 inches... (4.70 mm) Diameter Over 4th Shield 0.215 inches... (5.46 mm) Diameter Over Jacket 0.270 inches... (6.86 mm) Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 0.86 2.82 55 / Channel 2 2.05 6.73 83 / Channel 6 2.45 8.04 187 / Channel 9 3.60 11.81 211 / Channel 13 3.80 12.47 250 4.10 13.45 300 4.45 14.60 350 4.80 15.75 400 5.10 16.73 450 5.40 17.72 500 5.70 18.70 550 5.95 19.52 600 6.20 20.34 750 6.97 22.87 865 7.52 24.67 1000 8.12 26.64 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 21

MultiReach Drop Cable Series TM F6, F7 & F11 Series Description F Series 6, 7 or 11 Series coax with one (1) thru six (6) 22 AWG solid copper twisted pair conductors. Available in underground design with polyethylene flooded jacket (Amorphous Polypropylene [APD] and Extended Thermoplastic Rubber [ETPR]) or aerial design with polyvinylchloride (PVC) jacket and 0.072 inch galvanized steel messenger for self support. Standard Shield Coax Construction Bonded aluminum tape, 60% aluminum braid, jacket material. Super Shield (SS) Coax Construction Bonded aluminum tape, 60% aluminum braid, non-bonded aluminum tape, 42% aluminum braid, jacket material. Drop Cable MultiReach TM F Series 6, 7, or 11 Series coax with one (1) thru six (6) 22 Awg solid copper twisted paired conductors. Available in underground design with polyethylene (PE) flooded jacket (APD) or aerial and indoor designs with polyvinylchloride (PVC). Standard Coax* Aerial Coax* Underground Coax** F660BV F660BVM F660BE-APD F690BV F690BVM F690BE-APD F6SSV F6SSVM F6SSE-APD F760BV F760BVM F760BE-APD F7SSV F7SSVM F7SSE-APD F1160BV F1160BVM F1160BE-APD F1190BV F1190BVM F1190BE-APD F11SSV F11SSVM F11SSE-APD NOTES: Coax construction + # and awg of pairs = MultiReach TM F11SSE-APD + 5/22 (5 pairs of 22 awg conductors) = F11SSE-APD 5/22 V - Polyvinylcloride (PVC) VV - Flame Retardant PVC Jacket, NEC CATV VM - PVC Jacket with messenger VVM - Flame Retardant PVC jacket with messenger, NEC CATV *PVC jacket MultiReachTM cables are designed to be flooded or non-flooded. For flooded PVC cables, add APD to the end of coax description. APD will also be the floodant used over pairs. BE - Polyethylene Jacket (PE) BE APD - Flooded with PE jacket **PE jacketed MultiReach TM cables are designed to be flooded only, non-flooded not available. ETPR will be the floodant used over pairs unless otherwise requested. PE jacketed MultiReach TM cables with 3-6 pairs are also available with armor over the pairs, PVC not available. 22 For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com

MultiReach TM Drop Cable Specifications Nominal Diameter over Outer Jacket Coaxial Cable Web Width Pairs Web Width 0.072 Messenger F660BV 0.272 0.030 1-0.189 0.030 0.152 F6SSV 0.300 0.030 2-0.240 0.030 0.152 F760BV 0.318 0.030 3-0.270 0.030 0.152 F7SSV 0.338 0.030 4-0.285 0.030 0.152 F1160BV 0.395 0.030 5-0.300 0.030 0.152 F11SSV 0.405 0.030 6-0.330 0.030 0.152 Voice Pairs Description 22 AWG solid copper conductor, polyethylene insulation, unshielded twisted pair with rip cord. Solid Conductor 22 AWG (0.0253 inches) Number of Pairs Available 1-6 Standard Length 1000 ft/reel Identification Color code chart Pair Number Color Combination 1 Blue & White/Blue Stripe 2 Orange & White/Orange Stripe 3 Green & White/Green Stripe 4 Brown & White/Brown Stripe 5 Slate & White/Slate Stripe 6 Blue & Red/Blue Stripe See pages 7, 9, and 11 for coax construction and transmission data. For more information, call 800.982.1708, fax 828.328.3400 or visit our website at http://www.commscope.com 23

Notes