Ultraviolet (UV-Index) TOCON Datasheets

Similar documents
UV-Index Photodiodes Data Sheets

UV-Index Photodiodes Data Sheets

Content of this Catalog. General information about the sglux TOCONs. Selection guide p. 2. Product details of all TOCONs p. 5. Useful accessories p.

SiC UV Photodiodes Catalog

INDIUM SENSOR. Type X.5 Series

UV-A, UV-B & UV-I Sensors

Signal out Ranges Setting facilities U supply. 3 ranges configurable with jumpers. continuously adjustable amplification with potentiometer

The Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets

Light Sensors for Environmental Chambers

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

Improved Radiometry for LED Arrays

Ultraviolet selective thin film sensor TW30DY NEW: Read important application notes on page 4 ff.

Measuring the Performance of UV LED Light Sources

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

Advances in Measuring UV LED Arrays

INSTRUCTION MANUAL UV RADIOMETERS

LP UVA Introduction. 2 Working Principle. TEL r.a. FAX

[MILLIMETERS] INCHES DIMENSIONS ARE IN:

2 Channel Light Sensor

Influence of the light spectral distribution used in the radiometers calibration

OPB780-Kit. Color Sensor Evaluation Kit

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

P-CUBE-Series High Sensitivity PIN Detector Modules

Color Sensing using the OPB780

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

USER MANUAL MODEL 501-DA ANALOG UV BIOMETER SENSOR. Part Number: Revision Level: A

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

TSL257. High-Sensitivity Light-to-Voltage Converter. General Description. Key Benefits & Features

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

ams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:

ams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:

Silicon PIN Photodiode

ams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:

This document is a preview generated by EVS

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

CIE 220:2016 Characterization and Calibration Method of UV Radiometers

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

SILICon IrrADIAnCe SenSor

Red/Far-Red Sensor SKR 110. Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0)

Silicon PIN Photodiode

LI-1500 Light Sensor Logger

TSL267 HIGH-SENSITIVITY IR LIGHT-TO-VOLTAGE CONVERTER TAOS033E SEPTEMBER 2007

LP UVA 02. REV jan. 2007

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Silicon PIN Photodiode

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Silicon PIN Photodiode

EIT Instrument Markets Product Overview

REPORT OF CALIBRATION of One Standard of Spectral Irradiance ( nm)

ams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:

Spectroradiometer specbos 1201

PCS-150 / PCI-200 High Speed Boxcar Modules

ams AG TAOS Inc. is now The technical content of this TAOS datasheet is still valid. Contact information:

DC to 3.5-GHz Amplified Photoreceivers Models 1591 & 1592

TSL250RD, TSL251RD, TSL260RD, TSL261RD LIGHT-TO-VOLTAGE OPTICAL SENSORS

photodiodes Description PerkinElmer Optoelectronics offers a broad array of Silicon and InGaAs PIN and APDs.

First Sensor Evaluation Board Data Sheet Part Description MOD Order #

DC to 12-GHz Amplified Photoreceivers Models 1544-B, 1554-B, & 1580-B

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Ground-Based Solar UV Radiation Monitoring Technique Using Photocell. Pulchowk Campus, Institute of Engineering, Tribhuvan University, Nepal

Safety Angle Transducer Type Series Potentiometric, active

TSL253R LIGHT-TO-VOLTAGE OPTICAL SENSOR

0Introduction. TECHNICAL DOCUMENTATION 20/02/2009 PRESSURE Brake pressure PSI

Silicon PIN Photodiode

Variable Gain Photoreceiver Fast Optical Power Meter

Senturion XPR04 Proximity Probe

UV-dose indicator formulations as paint-onphotodetectors: way to optimize the UV curing process

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

FISCHER CUSTOM COMMUNICATIONS, INC.

TSL260, TSL261, TSL262 IR LIGHT-TO-VOLTAGE OPTICAL SENSORS

Broadbandradiometer specbos 1211

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

New PCA Accessory for the Q Series DSC Modules

TSLB257, TSLG257, TSLR257 HIGH-SENSITIVITY COLOR LIGHT-TO-VOLTAGE CONVERTERS TAOS027C JUNE 2006

SHF Communication Technologies AG

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

10-MHz Adjustable Photoreceivers Models 2051 & 2053

DESCRIPTION. The LUMENOLOGY Company Texas Advanced Optoelectronic Solutions Inc. 800 Jupiter Road, Suite 205 Plano, TX (972)

Oscilloscope Probes and Accessories

PDA36A Operating Manual - Switchable Gain, Amplified Silicon Detector

GPD. Germanium Photodetectors. GPD Optoelectronics Corp. OPTOELECTRONICS CORP. Small & Large Area pn, pin detectors Two-color detectors

Amplified High Speed Photodetectors

QL55 Series Luminescence Sensor

The Standard for over 40 Years

Sensor PAR xxx

We bring quality to light. MAS 40 Mini-Array Spectrometer

LI-193 Spherical Quantum Sensor

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm

Photo-Documentation of Ultraviolet Radiation Induced Visible Fluorescence on Daguerreotypes

15-GHz & 25-GHz Photodetectors Models 1480-S & 1481-S

ISO Determination of sunscreen UVA photoprotection in vitro. Détermination in vitro de la photoprotection UVA. First edition

LI-192 Underwater Quantum Sensor

Laser Systems. !!!! iflex-iris

Transcription:

Ultraviolet (UV-Index) TOCON Datasheets UV photodiode with integrated preamplifier SiC based UV sensors with 0 to 5 V voltage output measures intensities from 1.8pW/cm² up to 18W/cm² 91 Boylston Street, Brookline, MA 02445 tel: (617)566-3821 fax: (617)731-0935 www.boselec.com boselec@boselec.com

TOCON_E_OEM designed to work with customer s cosine correcting dome General Features Properties of the TOCON_E_OEM SiC based UV-Index photodetector in TO5 housing spectral response compliant to CIE087 / DIN5050 designed to work with customer s cosine correcting dome 0 5 V voltage output 1 UVI results a voltage of approx. 0.5 V Applications: UV-Index measurement with very small error <+-3% What is a TOCON? A TOCON is a 5 Volt powered UV photodetector with integrated amplifier converting UV radiation into a 0 5V voltage output. The V out pin of the TOCON can be directly connected to a controller, a voltmeter or any other data analyzing device with voltage input. Information about the UV-Index (UVI) The UV-Index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (see spectral responsivity). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297 nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) NomenclaturE TOCON_ ABC, A, B, C, blue or GaP 1 10 Spectral response Irradiance limits (V supply=5v, λ = λ peak) ABC = broadband = 290 nm λ S10% = 227 nm... 360 nm 1 = 1.8 pw/cm 2 18 nw/cm 2 A = UVA = 331 nm λ S10% = 309 nm... 367 nm B = UVB = 280 nm λ S10% = 243 nm... 303 nm C = UVC = 275 nm λ S10% = 225 nm... 287 nm Blue = 445 nm λ S10% = 390 nm... 515 nm Gap = 445 nm λ S10% = 190 nm... 570 nm 2 = 18 pw/cm 2 180 nw/cm 2 3 = 180 pw/cm 2 1.8 µw/cm 2 4 = 1.8 nw/cm 2 18 µw/cm 2 5 = 18 nw/cm 2 180 µw/cm 2 6 = 180 nw/cm 2 1.8 mw/cm 2 7 = 1.8 µw/cm 2 18 mw/cm 2 8 = 18 µw/cm 2 180 mw/cm 2 9 = 180 µw/cm 2 1.8 W/cm 2 10 = 1.8 mw/cm 2 18 W/cm 2 E = UV-Index spectral response according to CIE087 2 = 0 UVI 30 UVI

TOCON_E_OEM designed to work with customer s cosine correcting dome Specifications Parameter Symbol Value Unit Spectral Characteristics Approx. Sensitivity (unit is not calibrated) S max 0.5 V/UVI Visible Blindness (S max/s >405nm) VB > 10 10 General Characteristics (T=25, V supply =+5 V) Supply Voltage V Supply 2.5 5 V Saturation Voltage V Sat V Supply - 5% V Dark Offset Voltage V Offset 50 µv Temperature Coefficient at Peak T c < -0.3 %/K Current Consumption I 150 µa Bandwidth (-3 db) B 15 Hz Risetime (10-90%) t rise 0.182 s (other risetimes on request) Maximum Ratings Operating Temperature T opt 25 +85 Storage Temperature T stor 40 +100 Soldering Temperature (3s) T sold 300 Normalized Spectral Responsivity

TOCON_E_OEM designed to work with customer s cosine correcting dome Field of View Measurement Setup: lamp aperture diameter: 10 mm distance lamp aperture to second aperture: 17 mm second aperture diameter: 10 mm distance second aperture to detector: 93 mm pivot level = top surface of the detector window Drawing

TOCON_E_OEM designed to work with customer s cosine correcting dome Application Note for TOCONs The TOCONs need a supply voltage of V supply =2.5... 5V DC and can be directly connected to a controller or voltmeter. Please note that the theoretic maximum signal output is always a little less (approx. 5%) than the supply voltage. To learn more about perfect use of the TOCONs please refer to the TOCON FAQ list published at www.sglux.com. CAUTION! Wrong wiring leads to destruction of the device. For easy setup of the device please ask for a TOCON starter kit. Miniature steel housing with M12x1 thread for the TOCON series Optional feature for all TOCON detectors Robust stainless steel M12x1 thread body, length 32 mm Integrated sensor connector (Binder 4-Pin plug) with 2m connector cable Miniature PTFE housing with M12x1 thread for the TOCON series Optional feature for all TOCON detectors without concentrator lens Teflon (PTFE) M12x1 thread body, length 31 mm Wide field of view, dirt-repellant, water proof at wet side (IP 68) Integrated sensor connector (Binder 4-Pin plug) with 2m connector cable Easy to mount and connect, cleanable The PTFE housing reduces the signal output by approx. 95%. Please consider this while selecting the TOCON s sensitivity range. Plastic probes Optional feature for all TOCON detectors UV probes in small plastic housings with a TOCON inside Customized housings available Integrated sensor connector (Binder 4-Pin plug) Cable available Water pressure proof TOCON housing Optional feature for all TOCON detectors without concentrator lens G1/4 thread, 10 bar water pressure proof Customized housings available Integrated sensor connector (Binder 5-Pin plug) Cable available

TOCON_E1 General Features Properties of the TOCON_E1 SiC based UV-Index photodetector in TO5 housing with diffusor spectral response compliant to CIE087 / DIN5050 0 5 V voltage output peak wavelength at 280 nm 1 UVI results a voltage of approx. 1.7 V - attenuator needed Applications: UV-Index measurement with very small error <+-3% What is a TOCON? A TOCON is a 5 Volt powered UV photodetector with integrated amplifier converting UV radiation into a 0 5V voltage output. The V out pin of the TOCON can be directly connected to a controller, a voltmeter or any other data analyzing device with voltage input. Information about the UV-Index (UVI) The UV-Index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (see spectral responsivity). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297 nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) NomenclaturE TOCON_ ABC, A, B, C, blue or GaP 1 10 Spectral response Irradiance limits (V supply=5v, λ = λ peak) ABC = broadband = 290 nm λ S10% = 227 nm... 360 nm 1 = 1.8 pw/cm 2 18 nw/cm 2 A = UVA = 331 nm λ S10% = 309 nm... 367 nm B = UVB = 280 nm λ S10% = 243 nm... 303 nm C = UVC = 275 nm λ S10% = 225 nm... 287 nm Blue = 445 nm λ S10% = 390 nm... 515 nm Gap = 445 nm λ S10% = 190 nm... 570 nm 2 = 18 pw/cm 2 180 nw/cm 2 3 = 180 pw/cm 2 1.8 µw/cm 2 4 = 1.8 nw/cm 2 18 µw/cm 2 5 = 18 nw/cm 2 180 µw/cm 2 6 = 180 nw/cm 2 1.8 mw/cm 2 7 = 1.8 µw/cm 2 18 mw/cm 2 8 = 18 µw/cm 2 180 mw/cm 2 9 = 180 µw/cm 2 1.8 W/cm 2 10 = 1.8 mw/cm 2 18 W/cm 2 E = UV-Index spectral response according to CIE087 2 = 0 UVI 30 UVI

TOCON_E1 Specifications Parameter Symbol Value Unit Spectral Characteristics Approx. Sensitivity (unit is not calibrated) S max 1.7 V/UVI Visible Blindness (S max/s >405nm) VB > 10 10 General Characteristics (T=25, V supply =+5 V) Supply Voltage V Supply 2.5 5 V Saturation Voltage V Sat V Supply - 5% V Dark Offset Voltage V Offset 50 µv Temperature Coefficient at Peak T c < -0.3 %/K Current Consumption I 150 µa Bandwidth (-3 db) B 15 Hz Risetime (10-90%) t rise 0.182 s (other risetimes on request) Maximum Ratings Operating Temperature T opt 25 +85 Storage Temperature T stor 40 +100 Soldering Temperature (3s) T sold 300 Normalized Spectral Responsivity

TOCON_E1 Field of View Measurement Setup: lamp aperture diameter: 10 mm distance lamp aperture to second aperture: 17 mm second aperture diameter: 10 mm distance second aperture to detector: 93 mm pivot level = top surface of the detector window Drawing

TOCON_E1 Application Note for TOCONs The TOCONs need a supply voltage of V supply =2.5... 5V DC and can be directly connected to a controller or voltmeter. Please note that the theoretic maximum signal output is always a little less (approx. 5%) than the supply voltage. To learn more about perfect use of the TOCONs please refer to the TOCON FAQ list published at www.sglux.com. CAUTION! Wrong wiring leads to destruction of the device. For easy setup of the device please ask for a TOCON starter kit. Miniature steel housing with M12x1 thread for the TOCON series Optional feature for all TOCON detectors Robust stainless steel M12x1 thread body, length 32 mm Integrated sensor connector (Binder 4-Pin plug) with 2m connector cable Miniature PTFE housing with M12x1 thread for the TOCON series Optional feature for all TOCON detectors without concentrator lens Teflon (PTFE) M12x1 thread body, length 31 mm Wide field of view, dirt-repellant, water proof at wet side (IP 68) Integrated sensor connector (Binder 4-Pin plug) with 2m connector cable Easy to mount and connect, cleanable The PTFE housing reduces the signal output by approx. 95%. Please consider this while selecting the TOCON s sensitivity range. Plastic probes Optional feature for all TOCON detectors UV probes in small plastic housings with a TOCON inside Customized housings available Integrated sensor connector (Binder 4-Pin plug) Cable available Water pressure proof TOCON housing Optional feature for all TOCON detectors without concentrator lens G1/4 thread, 10 bar water pressure proof Customized housings available Integrated sensor connector (Binder 5-Pin plug) Cable available

TOCON_E2 General Features Properties of the TOCON_E2 SiC based UV-Index photodetector in TO5 housing with diffusor spectral response compliant to CIE087 / DIN5050 0 5 V voltage output peak wavelength at 280 nm 1 UVI results a voltage of approx. 170 mv Applications: UV-Index measurement with very small error <+-3% What is a TOCON? A TOCON is a 5 Volt powered UV photodetector with integrated amplifier converting UV radiation into a 0 5V voltage output. The V out pin of the TOCON can be directly connected to a controller, a voltmeter or any other data analyzing device with voltage input. Information about the UV-Index (UVI) The UV-Index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (see spectral responsivity). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297 nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) NomenclaturE TOCON_ ABC, A, B, C, blue or GaP 1 10 Spectral response Irradiance limits (V supply=5v, λ = λ peak) ABC = broadband = 290 nm λ S10% = 227 nm... 360 nm 1 =.,8 pw/cm 2 18 nw/cm 2 A = UVA = 331 nm λ S10% = 309 nm... 367 nm B = UVB = 280 nm λ S10% = 243 nm... 303 nm C = UVC = 275 nm λ S10% = 225 nm... 287 nm Blue = 445 nm λ S10% = 390 nm... 515 nm Gap = 445 nm λ S10% = 190 nm... 570 nm 2 = 18 pw/cm 2 180 nw/cm 2 3 = 180 pw/cm 2 1.8 µw/cm 2 4 = 1.8 nw/cm 2 18 µw/cm 2 5 = 18 nw/cm 2 180 µw/cm 2 6 = 180 nw/cm 2 1.8 mw/cm 2 7 = 1.8 µw/cm 2 18 mw/cm 2 8 = 18 µw/cm 2 180 mw/cm 2 9 = 180 µw/cm 2 1.8 W/cm 2 10 = 1.8 mw/cm 2 18 W/cm 2 E = UV-Index spectral response according to CIE087 2 = 0 UVI 30 UVI

TOCON_E2 Specifications Parameter Symbol Value Unit Spectral Characteristics Approx. Sensitivity (unit is not calibrated) S max 170 mv/uvi Visible Blindness (S max/s >405nm) VB > 10 10 General Characteristics (T=25, V supply =+5 V) Supply Voltage V Supply 2.5 5 V Saturation Voltage V Sat V Supply - 5% V Dark Offset Voltage V Offset 50 µv Temperature Coefficient at Peak T c < -0.3 %/K Current Consumption I 150 µa Bandwidth (-3 db) B 15 Hz Risetime (10-90%) t rise 0.182 s (other risetimes on request) Maximum Ratings Operating Temperature T opt 25 +85 Storage Temperature T stor 40 +100 Soldering Temperature (3s) T sold 300 Normalized Spectral Responsivity

TOCON_E2 Field of View Measurement Setup: lamp aperture diameter: 10 mm distance lamp aperture to second aperture: 17 mm second aperture diameter: 10 mm distance second aperture to detector: 93 mm pivot level = top surface of the detector window Drawing

TOCON_E2 Application Note for TOCONs The TOCONs need a supply voltage of V supply =2.5... 5V DC and can be directly connected to a controller or voltmeter. Please note that the theoretic maximum signal output is always a little less (approx. 5%) than the supply voltage. To learn more about perfect use of the TOCONs please refer to the TOCON FAQ list published at www.sglux.com. CAUTION! Wrong wiring leads to destruction of the device. For easy setup of the device please ask for a TOCON starter kit. Miniature steel housing with M12x1 thread for the TOCON series Optional feature for all TOCON detectors Robust stainless steel M12x1 thread body, length 32 mm Integrated sensor connector (Binder 4-Pin plug) with 2m connector cable Miniature PTFE housing with M12x1 thread for the TOCON series Optional feature for all TOCON detectors without concentrator lens Teflon (PTFE) M12x1 thread body, length 31 mm Wide field of view, dirt-repellant, water proof at wet side (IP 68) Integrated sensor connector (Binder 4-Pin plug) with 2m connector cable Easy to mount and connect, cleanable The PTFE housing reduces the signal output by approx. 95%. Please consider this while selecting the TOCON s sensitivity range. Plastic probes Optional feature for all TOCON detectors UV probes in small plastic housings with a TOCON inside Customized housings available Integrated sensor connector (Binder 4-Pin plug) Cable available Water pressure proof TOCON housing Optional feature for all TOCON detectors without concentrator lens G1/4 thread, 10 bar water pressure proof Customized housings available Integrated sensor connector (Binder 5-Pin plug) Cable available