Product description PLJ-1601-C Frequency display module is designed for HAM Design of frequency measurement instruments. Its compact, easy operation, reliable work, mainly for the DIY transceiver frequency value displayed can also be used for normal frequency measurement.the frequency meter's main features are as follows: Master United States micro-core ( Microchip ) PIC16F648A At the core of 65MHz Frequency meter. Reference Japan KDS Temperature-compensated voltagecontrolled Crystal oscillator ( ± 2.5 ppm VC-TCXO ) More high performance external reference, the software supports 13.000 MHz, and12.800 MHz, and10.000 MHz and 4.000 MHz four external reference sources. Uses a unique algorithm of gate control and precise time (unscheduled interruption). Time gate (display refresh) 0.01 Seconds /0.1 Seconds /1.0 Second optional third gear. Enter the three-channel single-ended (low channel / High channel / Automatic channel) is optional. Add or subtract frequency function, if value can be adjusted, and / Reduction mode is optional. LCD1601/1602 Character LCD display frequency, the maximum display 9 Digit frequency value invalid zero blanking, invalid frequency value display filtering is optional. Four-button control, human-machine interface is good. The settings are automatically saved in EEPROM In the next time you boot program.
Technical parameters Technical parameters 1. gate time (Gate time) 0.01 Seconds 0.10 Seconds 1.0 Seconds 2. measurement (Measurement channels) The low road (high impedance) Measuring range ( Measuring range ): 0.1 MHz ~ 60 MHz Measurement accuracy ( Accuracy ): 100Hz (0. 01 second gate Shi ) Low channel sensitivity ( Sensitivity ): Testing frequency(mhz) Sensitivity (mv RMS) High channel (High impedance) ± 10Hz (0.10 seconds at the gate) ± 1Hz (1.00 seconds at the gate) HM8134-2 Test data (for reference only) 0.1 1 5 10 30 40 50 60 65 5 5 6 6 14 19 24 29 33 Measuring range ( Measuring range ): 1 MHz ~ 1.2 GHz Measurement accuracy ( Accuracy ): ± 6400Hz (0.01 seconds at the gate) High channel sensitivity ( Sensitivity ): Testing frequency(mhz) Sensitivity (mv RMS) Testing frequency(mhz) Sensitivity (mv RMS) Automatic Channel ± 640Hz (0.10 seconds at the gate) ± 64Hz (1.00 seconds at the gate) HM8134-2 Test data (for reference only) 5 10 30 60 100 150 200 300 450 11 7 3 3 2 3 3 7 13 500 550 600 700 800 900 1000 1100 1200 12 21 21 43 125 60 32 51 70 According to the frequency of the input signal automatically selects the channel high or low Channel, frequency of recognition is60 MHz If input is greater than 60 MHz signal amplitude of less than higher channel cannot be selected automatically, you should manually select frequency measurement with high pass road. 3. frequency setting (Frequency offset)
Mid frequency step 100 Hz Adjust range 0 ~ 999.9999 MHz Can be set to add MF or MF mode reduction manufactured frequency value defaults to zero (the displayed value is the frequency). 4. the frequency baseline (Frequency reference) Onboard 5032 Package 13.000MHz Temperature compensated voltagecontrolled Crystal oscillator ( VC-TCXO ), The frequency stability is ±2.5 ppm With an external frequency standard interfaces, software currently supports the frequency baseline:13.000 MHz, and12.800 MHz, and10.000 MHz and 4.000 MHz Four reference. 5. operating voltage (Operating voltage) DC input: DC 9V ~ 12V (Power supply reverse polarity protection) 6. operating current (Current) Turn on backlight: 70 ma Disable the backlight: 55 ma(disconnect the backlight power supply) 7. display digits (Display digits) The highest 9 -Digital display 8. the physical dimensions (Physical Dimensions) Long Width Height: 95mm 37mm 27mm 9. Component Quality ( Weight ) 65 g (Approximately) 10. Onboard connectors ( Schnittstellen ) RF INPUT (Signal input): XH2.54-2P Bent pin square socket ICSP INPUT ( MCU Programming interface): XH2.54-6P Bent pin square socket INPUT INPUT (External clock input): XH2.54-2P Bent pin square socket POWER INPUT (Power interface): 1Ф3.5mm DC Socket (Uchimasa negative) 2XH2.54-2P Bent pin square socket
Using the action Operation
Three. Action steps (A) preparatory work 1. Before use, please check the power supply voltage (DC 9V-12V) and polar, confirmed the power plug is inserted into the instrument ф 3.5mm DC Socket (Uchimasa negative), and ф 3.5mm DC Next to the socket 2P Socket input 9V-12V DC voltage Foolproof design of this machine, power supply polarity reversed the machine does not work, but will not have devastating consequences. 2. Measuring signal input 2P port access testing line ( wire ) or antenna (induction). 3. Instrument power Preheat for several minutes after the frequency baseline stability measuring operation again. (B) feature set Gate Setting Low High Frekuensi Setting
Reset Setting / sistem ulang Advance setting
Note: actually displayed in red text to display information. Menu details ( 1 ) If set 1 NO IF (If free) Displays the frequency of the measured frequency. 2 SET IF (MF) Displays the frequency is measured by the frequency and / After reduction-if frequency. Selecting this item displays the current frequency value, one of the digits are underlined below for current changes, press " Or the key " Key to change the value, press the " SET Keys underline moves to the next digit, then press " Or the key" Keys to change the values, and so on until the frequency value is set, press " OK Key after entering / Medium frequency reduction settings, press " Or the key " Key change plus or minus, and then press " OK Button to complete the intermediate frequency interface settings and return to work. If adjustment, press " " or key "" -digital connection, you can speed up the set speed. ( 2 ) Showed filtering 1 FILTER ON (Filter enabled) In order to avoid illusion caused when there is no signal input clutter signal count Filter frequency < 3MHz Signal frequency display the main page 0.00000 MHz 2 FILTER OFF (Filtering disabled) Frequency < 3MHz Filter processing of signals. Measuring frequency <3MHz signal should choose this setting, otherwise the display 0.00000 MHz.
( 3 ) LCD Type 1 1601 LCD 1601 Character LCD screen. 2 1602 LCD 1602 Character LCD screen. Note: according to the actual use of LCD Type settings, error setting will display exception, such as 1602 Appeared in two line display, 1601 After the 8 Characters are not displayed. ( 4 ) Datum selection 1 13.000 MHz The machine onboard Benchmark (The default). 2 12.800 MHz 12.800 MHz External Benchmark Settings. 3 10.000 MHz 10.000 MHz External Benchmark Settings. 4 4.000 MHz 4.000 MHz External Benchmark Settings. Note: If using an external Benchmark, Please cut off the built-in Base power supply or output Pathways, such as removing bead B4And so on.
(E) frequency measurement 1. Cable way RF INPUT (Signal input) connection port and the signal measured by the test line frequency. Measurement of the vibration signal. 2. Induction methods
RF INPUT (Measuring input) port connected to the test antenna, induction measurement frequency of the transmitted signal.wireless transmitting equipment such as radio frequency measurements. Measurement of high voltage and high frequency radiation signal, cable should be threaded resistance, Induction Frequency meter should be far away from the radiation source, so as not to damage the instrument.
Ordering products Ordering products To facilitate testing, Three sword Studios provides small volume production, procurement or agents please enter the main page search Taobao " Studio three sword " or " PLJ-1601 " keyword, or contact the Studio directly. Scan the QR code on the product packing bag and sealing label into the Web site to obtain product related technical support. Product description: SMD devices installed Reflow soldering process LCD 1601 Nickel plated copper post installation No power, no case Debugging product Packing list: Notes: Host XH2.54-2P 20cm Single line Two Anti-static bags Suite two distribution XH2.54-2P 20cm Single line, please do not use color as the polarity of the judgment, outlet before accessing the host to determine the polarity, read the contents of the operation section of this manual for details Power entry has two ports, host bottom Ф3.5mm DC Socket (Uchimasa negative) and next to it 2P Square socket, please enter according to actual situation 9-12V Power supply. Market LCD Mounting hole size differences, such as configure LCD Screen shall comply with the specifications of the drawings. LCD Screen with four stainless steel screws, if panel mounting is required, please go into four 8 mm Copper cylinders, or notify us prior to shipment to replace. LCD Without backlight broken backlight power supplies (unsolder Board top 0 European resistance). If an external reference is required, please switch off the onboard clock channel, and ECK Socket input specification of reference signal. Native display no signal input may be zero, this is normal and does not affect the normal measurements and accuracy.
Do not place the instrument in hot, humid and dusty conditions and should avoid using by violent vibrations. Native built into the clock reference used rubidium atomic clock correction, sensitivity to the best, do not adjust. In the warranty period under normal use conditions for one year. Warranty does not apply to misuse, modification, such as under abnormal conditions cause damage to the product. The drawings