Radiographic testing: Increased detection sensitivity using optimum source to object distance

Similar documents
Engineering Policy & Procedure

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

The HOIS recommended practice for in-service computed radiography of pipes

RADIOGRAPHIC EXAMINATION PROCEDURE

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Welding Inspection Non-Destructive Testing Course Reference WIS 5

This document is a preview generated by EVS

Advanced Digital Radiography for Field NDT

Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL. Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE

Gamex Lite 3.0 Program description and operating manual

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

Part 3: Image quality classes

NDE Technology of Pressure Equipment in Line with International Standards

Pre Conference Workshop on Advanced Digital imaging

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Introduction To NDT. BY: Omid HEIDARY

Fig.2: Scanner VistaScan for image plates

ISO INTERNATIONAL STANDARD

ON THE WAY TO DIGITAL RADIOGRAPHY

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Examination of Pipe Welds by Image Plate Based Computed Radiography System

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Experiences of users in Digital Radiography

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

ISO INTERNATIONAL STANDARD

Computed Radiography

THE CR SPECIALISTS HD-CR CR 35 NDT

The field deployable digital X-Ray solution for weld inspection in O&G

Non-destructive testing Image quality of radiographs. Part 2: Determination of the image quality value using step/hole-type image quality indicators

Digital Radiography : Flat Panel

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

International Standard

Module 4 Design for Assembly IIT BOMBAY

Non-destructive testing of welds Radiographic testing of welded joints

Ray Detection Digital Image Quality and Influential Factors

Performance evaluation of a photon counting detector for high energy NDT applications

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

international Standard 1106/l

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

Record Adoption of ASTM E b as an Update of SE Nov-12 Page 1 of 5

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

Radiographic Testing (RT) [10]

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Strategies for Film Replacement in Radiography - a comparative study -

Ayaz Jhanorwala, Rishikesh Kumar, Satish Tilva. L & T MHPS Boilers Pvt Ltd., Hazira, Surat , India

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Digital Radiography and its Advantages in Field NDT Inspections Today

ISO INTERNATIONAL STANDARD

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Digital Radiography for the Inspection of Small Defects

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

A Modified Detectability Criterion for Conventional Radiography Simulation

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

Standard Test Method for Radiographic Examination of Metallic Castings 1

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

ISO 7004 INTERNATIONAL STANDARD

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

COMPUTED RADIOGRAPHY THE STATE OF THE ART

Oförstörande provning av svetsförband, formvaror av termoplast Del 2: Röntgenprovning

GB/T Translated English of Chinese Standard: GB/T

Real Time Linear Array Imaging. Brian Caccamise

Overview. Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing

NDT-PRO Services expands service offering

Australian Journal of Basic and Applied Sciences

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

NPTEL NPTEL ONLINE COURSE. NPTEL Online Certification Course (NOC) NPTEL. Theory and Practice of Non Destructive Testing

Projection Radiography. application on stream

REGULATION OF TECHNICAL STANDARDS OF DIGITAL RADIOGRAPHY: LITERATURE REVIEW

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

This document is a preview generated by EVS

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Standard Practice for Radiographic Examination 1

X-RAYS - NO UNAUTHORISED ENTRY

Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method) 1

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

Modern Electromagnetic Equipment for Nondestructive Testing

This document is a preview generated by EVS

Svetskommissionen. Review of SS-EN ISO 2553:2014

Migrating from traditional to Digital Radiography in Aerospace

Objective Evaluation of Radiographic Contrast- Enhancement Masks

LECTURE 1 The Radiographic Image

Digital Radiography, Flexible Risers

Contrast. Contrast: the difference in density on adjacent areas of a radiograph or other image receptor. Subjective. Long Scale (Low Contrast)

Welding Qualification/Certification

Beam-Restricting Devices

Transcription:

18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN Non Destructive Testing lecturer at the Southern African Institute of Welding 52 Western Boulevard City west Johannesburg Gauteng Province South Africa. Phone +2711 298 2131 Fax +2711 298 2131 e-mail cowanj@saiw.co.za Abstract Previous research has shown, when using a Se-75 isotope as source, that not only is the DWSI Technique as effective as the DWDI Technique for finding linear cracks in welded pipe samples, but in some instances even superior, both in the geometric unsharpness and exposure duration with an improved probability of detection for mentioned defects. (Test sample: Pipe - 50mm ID, 3.9mm wall thickness, up to 3mm weld build-up) Conformance with ASME V Article 2 is achievable. Conformance with EN1435 Image Quality Class A can be achieved. However, the requirements for Image Quality EN1435 Class B are not attainable due to the non-linear nature of the formula applied for determining the minimum source-to-object-distance. Work has been carried out to improve the probability of detection by determining the minimum source-to-objectdistance without negating radiographic quality using short exposure times. Keywords: Radiographic testing, Source to object testing, Double wall single image. Definitions: ASME: American society of mechanical engineers ISO: international standards organization Ug: Geometrical unsharpnes as calculated with the ASME V art. 2. formula. d f Ug D Where; d = object to film distance D = source to film distance f = effective focal spot EN 1435 Source to object distance formula f 3 2 Class A: 7.5 b d f 3 2 Class B: 15 b d Where: f = source to object distance b = object to film distance d = source size

Introduction: Conformance with ASME V Article 2 is achievable, as may be seen from the following quote it: ASME V article 2 paragraph T-271.2 (b) For pipe diameters not exceeding 89 mm a technique may be used in which the radiation passes through two walls and the weld (material) in both walls is viewed for acceptance on the same radiograph. Care should be exercised to ensure that the required geometric unsharpness is not exceeded. If the geometric unsharpness cannot be met, then single-wall viewing shall be used. I.e. ASME V Article 2 allows double wall imaging techniques without specifying whether the image should be double-wall or single-wall unless geometric unsharpness cannot be met if this is the case then single-wall images are mandatory! Investigation and results: In the following two radiographs count the number of discontinuities present. Radiograph 1 Double wall double image source side IQI 0.25mm wire visible 0 to 4cm and 8 to 12 cm The geometrical unsharpness is 0.5mm

Radiograph 2 Double wall double image source side IQI 0.25mm wire visible 4 to 8cm and 12 to 0 cm. The geometrical unsharpness is 0.5mm We see a tungsten inclusion some porosity and some undercut let s compare this to some double wall single image radiographs number 3 to 8 Radiograph 3 Double wall single image source side IQI placed inside the pipe 0.20mm wire visiable 0 to 4cm The geometrical unsharpness is 0.3mm

Radiograph 4 Double wall single image source side IQI placed inside the pipe 0.20mm wire visiable 4 to 8cm. The geometrical unsharpness is 0.3mm

Radiograph 5 Double wall single image source side IQI placed inside the pipe 0.20mm wire visiable 8 to 12cm. The geometrical unsharpness is 0.3mm

Radiograph 6 Double wall single image source side IQI placed inside the pipe 0.20mm wire visiable 12 to 0cm. The geometrical unsharpness is 0.3mm On radiograph 3 and 4 we can clearly see cracks that were missed on the double wall double image radiographs. This proves the acceptance of double wall single image radiography to ASME 5 art 2 for density and IQI visibility. Conformance with EN1435 or ISO 17636 Image Quality Class A can be achieved. However, the requirements for Image Quality EN1435 ISO 17636 Image Quality Class B will be difficult due to the non-linear nature of the formula applied for determining the minimum source-to-object-distance. Let s investigate further: With a Gilardoni X ray machine serial no. 22070002 with a 4.5 X 4.5 mm focal spot size Some radiographs of the parent material of a 10mm plate butt weld were taken, on Agfa D4 film.

Radiograph no 7: 155 mm focus to object distance and 16mm object to film distance. A crack is visible above the weld and wire no 15 of the 10 FE EN pennetrameter is visible. The geometrical unsharpness is 0.66mm

Radiograph no 8: 160 mm focus to object distance and 10mm object to film distance. A crack is visible above the weld and wire no 15 of the 10FE EN pennetrameter is visible. The geometrical unsharpness is 0.4mm Radiograph no 9: 225 mm focus to object distance and 10mm object to film distance. A crack is visible above the weld and wire no 15 of the 10FE EN pennetrameter is visible. The geometrical unsharpness is 0.28mm

Radiograph no 10: 475 mm focus to object distance and 10mm object to film distance. A crack is visible above the weld and wire no 15 of the 10 FE EN pennetrameter is visible. The geometrical unsharpness is 0.14mm Radiograph no 11: 692 mm focus to object distance and 63mm object to film distance. A crack is visible above the weld and wire no 15 of the 10 FE EN pennetrameter is visible. The geometrical unsharpness is 0.58mm

Conclusion: From 0.14 mm geometric unsharpness to 0.65mm geometric unsharpness no significant visible change is noticeable. I can only conclude from this that for X-Ray machine work and most probably due to the better subject contrast geometric unsharpness less than 0.65mm is not necessary. It is my opinion that conformance to EN 1435 class B with it s overly long focal to object distance as far as geometrical unsharpness is concerned is a total waste of time. It would be better to use a shorter focus to object distance on curved objects and to observe the 1.1mm maximum change in wall thickness. I.e. double wall single image radiography instead of double wall double image radiography as illustrated at the start of the paper. We saw that this is easy to apply to ASME 5 art 2 of 2010 If we have to comply with EN 12952 of 2002 for boilers on a new power station started around 2008 EN 12952-6 of 2002 sends us to EN 1435 of 1997 class A or B? for radiography. EN 12952-6 of does not refer us to a class. EN 12952-6 do reference EN 25817 of 1992 in its normative references however this does not refer us to a class either. So class A may do and we may develop procedure to do this. Bibliography: EN 12952-6 of 2002 EN 25817 of 1992 EN 1435 of 1997 ASME V art. 2 of 2010