DC Machine Construction. Figure 1 General arrangement of a dc machine

Similar documents
3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

Placement Paper For Electrical

Types of Generators ACCORDING TO EXCITATION

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

Module 9. DC Machines. Version 2 EE IIT, Kharagpur

Generator Advanced Concepts

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

Generalized Theory Of Electrical Machines

Questions on Electromagnetism

COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65

Objective Questions UNIT-I TRANSIENT ANALYSIS (First and Second Order Circuits)

Contents. About the Authors. Abbreviations and Symbols

Inductance, capacitance and resistance

Armature Windings - Nptel Coil Pitch In An Ac Armature Winding Full Pitch Winding Dc Motor Basics - Abb Group

PHYS 1444 Section 003 Lecture #19

3.1.Introduction. Synchronous Machines

1. Explain in detail the constructional details and working of DC motor.

SYNCHRONOUS MACHINES


1. A battery has an emf of 12.9 volts and supplies a current of 3.5 A. What is the resistance of the circuit?

VALLIAMMAI ENGINEERING COLLEGE

1. (a) Determine the value of Resistance R and current in each branch when the total current taken by the curcuit in figure 1a is 6 Amps.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS

CHAPTER 5 SYNCHRONOUS GENERATORS

Actuators. EECS461, Lecture 5, updated September 16,

Hours / 100 Marks Seat No.

A Practical Guide to Free Energy Devices

TRANSFORMER THEORY. Mutual Induction

PHYS 1442 Section 004 Lecture #15

CHAPTER 1 SYNCHROS LEARNING OBJECTIVES. 5. Explain the differences between torque and control synchros.

IOCL Electrical Engineering Technical Paper

ELECTRICAL TECHNOLOGY

ESO 210 Introduction to Electrical Engineering

Electronic Speed Controls and RC Motors

GOVERNMENT COLLEGE OF ENGINEERING, BARGUR

No. of Printed Pages : 5 ADVANCED LEVEL CERTIFICATE COURSE IN ELECTRICAL ENGINEERING / DIPLOMA IN ELECTRICAL ENGINEERING / ACELVI / DELVI

ELG2336 Introduction to Electric Machines

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Type of loads Active load torque: - Passive load torque :-

EE 350: Electric Machinery Fundamentals

CHAPTER 2 STATE SPACE MODEL OF BLDC MOTOR

Page ENSC387 - Introduction to Electro-Mechanical Sensors and Actuators: Simon Fraser University Engineering Science

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Electronics & Communication Engineering

D.c Machine Windings 3.1 Introduction :- ) lap winding Wave winding

A Practical Guide to Free Energy Devices

The Fundamental Characteristics of Novel Switched Reluctance Motor with Segment Core Embedded in Aluminum Rotor Block

Direct Current Motor Electrical Evaluation Using Motor Circuit Analysis

A Practical Guide to Free Energy Devices

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Electrical Machines (EE-343) For TE (ELECTRICAL)

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS)

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

UNIT II MEASUREMENT OF POWER & ENERGY

Modelling of a universal motor with speed control. Henrik Grop

Robot Actuators. Motors and Control. Stepper Motor Basics. Increased Resolution. Stepper motors. DC motors AC motors. Physics review: Nature is lazy.

Module 1. Introduction. Version 2 EE IIT, Kharagpur

Bakiss Hiyana binti Abu Bakar JKE, POLISAS BHAB

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

In an unmagnetized piece of iron, the atoms are arranged in domains. In each domain the atoms are aligned, but the domains themselves are random.

Objective: Study of self-excitation characteristics of an induction machine.

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017

Permanent Magnet Generators (PMG)

Introduction. A closed loop of wire is not an electrical circuit, a circuit requires

A Comparative Study of Sinusoidal PWM and Space Vector PWM of a Vector Controlled BLDC Motor

Sizing Generators for Leading Power Factor

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

Basic NC and CNC. Dr. J. Ramkumar Professor, Department of Mechanical Engineering Micro machining Lab, I.I.T. Kanpur

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

VARIABLE INDUCTANCE TRANSDUCER

In this lecture. Electromagnetism. Electromagnetism. Oersted s Experiment. Electricity & magnetism are different aspects of the same basic phenomenon:

Synchronous Machines Study Material

MG Electrical Machine. 68 _ ED Co.,Ltd. > EXPERIMENTS > SPECIFICATIONS

Code No: R Set No. 1

CHAPTER 8: ELECTROMAGNETISM

Manuals. Basic Electrical Engineering BE-104

Code No: R Set No. 1

HARMONICS CAUSES AND EFFECTS

UNIT 9 DC Separately-Excited Generator

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

(a) (i) Is the transformer in the diagram being used as a step-up transformer or as a step-down transformer? ) in the box next to your answer. ...

Detect stepper motor stall with back EMF technique (Part 1)

DISCUSSION OF FUNDAMENTALS

Outcomes from this session

Computer Numeric Control

DC SOURCES. 1.1 LIST the four ways to produce a DC voltage. 1.2 STATE the purpose of a rectifier.

Administrative Notes. DC Motors; Torque and Gearing; Encoders; Motor Control. Today. Early DC Motors. Friday 1pm: Communications lecture

DC MOTOR SPEED MEASUREMENT BASED ON BRUSH EFFECTS

Sinusoidal Control of a Single Phase Special Topology SRM, Without Rotor Position Sensor

Magnetism can produce electric current can. produce magnetism Electromagnetic Induction

37 Electromagnetic Induction. Magnetism can produce electric current, and electric current can produce magnetism.

AC Machinery. Revised October 6, Fundamentals of AC Machinery 1

Transcription:

1 DC Motor The direct current (dc) machine can be used as a motor or as a generator. DC Machine is most often used for a motor. The major adantages of dc machines are the easy speed and torque regulation. Howeer, their application is limited to mills, mines and trains. As examples, trolleys and underground subway cars may use dc motors. In the past, automobiles were equipped with dc dynamos to charge their batteries.

1 DC Motor Een today the starter is a series dc motor Howeer, the recent deelopment of power electronics has reduced the use of dc motors and generators. The electronically controlled ac dries are gradually replacing the dc motor dries in factories. eertheless, a large number of dc motors are still used by industry and seeral thousand are sold annually.

1 Construction

DC Machine Construction Figure 1 General arrangement of a dc machine

The stator of the dc motor has poles, which are excited by dc current to produce magnetic fields. In the neutral zone, in the middle between the poles, commutating poles are placed to reduce sparking of the commutator. The commutating poles are supplied by dc current. Compensating windings are mounted on the main poles. These short-circuited windings damp rotor oscillations.. DC Machines

The poles are mounted on an iron core that proides a closed magnetic circuit. The motor housing supports the iron core, the brushes and the bearings. The rotor has a ring-shaped laminated iron core with slots. Coils with seeral turns are placed in the slots. The distance between the two legs of the coil is about 180 electric degrees. DC Machines

The coils are connected in series through the commutator segments. The ends of each coil are connected to a commutator segment. The commutator consists of insulated copper segments mounted on an insulated tube. Two brushes are pressed to the commutator to permit current flow. The brushes are placed in the neutral zone, where the magnetic field is close to zero, to reduce arcing. DC Machines

The rotor has a ring-shaped laminated iron core with slots. The commutator consists of insulated copper segments mounted on an insulated tube. Two brushes are pressed to the commutator to permit current flow. The brushes are placed in the neutral zone, where the magnetic field is close to zero, to reduce arcing. DC Machines

The commutator switches the current from one rotor coil to the adjacent coil, The switching requires the interruption of the coil current. The sudden interruption of an inductie current generates high oltages. The high oltage produces flashoer and arcing between the commutator segment and the brush. DC Machines

DC Machine Construction Rotation /2 Shaft Brush /2 Pole winding 8 1 2 7 3 S 6 4 5 Insulation Rotor Winding Copper segment Figure 2 Commutator with the rotor coils connections.

DC Machine Construction Figure 3 Details of the commutator of a dc motor.

DC Machine Construction Figure 4 DC motor stator with poles isible.

DC Machine Construction Figure 5 Rotor of a dc motor.

DC Machine Construction Figure 6 Cutaway iew of a dc motor.

2.1 DC Motor Operation

DC Motor Operation In a dc motor, the stator poles are supplied by dc excitation current, which produces a dc magnetic field. The rotor is supplied by dc current through the brushes, commutator and coils. The interaction of the magnetic field and rotor current generates a force that dries the motor /2 Shaft Brush 7 8 6 Insulation Rotor Winding Rotation 1 5 2 4 3 /2 Copper segment Pole winding S

2.1 DC Motor Operation The magnetic field lines enter into the rotor from the north pole () and exit toward the south pole (S). The poles generate a magnetic field that is perpendicular to the current carrying conductors. The interaction between the field and the current produces a Lorentz force, The force is perpendicular to both the magnetic field and conductor S b 1 2 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S B a a B 30 1 2 b V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.1 DC Motor Operation The generated force turns the rotor until the coil reaches the neutral point between the poles. At this point, the magnetic field becomes practically zero together with the force. Howeer, inertia dries the motor beyond the neutral zone where the direction of the magnetic field reerses. To aoid the reersal of the force direction, the commutator changes the current direction, which maintains the counterclockwise rotation.. S b 1 2 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S B a a 30 1 2 b B V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.1 DC Motor Operation Before reaching the neutral zone, the current enters in segment 1 and exits from segment 2, Therefore, current enters the coil end at slot a and exits from slot b during this stage. After passing the neutral zone, the current enters segment 2 and exits from segment 1, This reerses the current direction through the rotor coil, when the coil passes the neutral zone. The result of this current reersal is the maintenance of the rotation. S b 1 2 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S B a a 30 1 2 b B V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.2 DC Generator Operation

2.2 DC Generator Operation The -S poles produce a dc magnetic field and the rotor coil turns in this field. A turbine or other machine dries the rotor. The conductors in the slots cut the magnetic flux lines, which induce oltage in the rotor coils. The coil has two sides: one is placed in slot a, the other in slot b. S b 1 2 B a 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S a 30 1 2 B b V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.2 DC Generator Operation In Figure 11A, the conductors in slot a are cutting the field lines entering into the rotor from the north pole, The conductors in slot b are cutting the field lines exiting from the rotor to the south pole. The cutting of the field lines generates oltage in the conductors. The oltages generated in the two sides of the coil are added. S b 1 2 B a 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S a 30 1 2 B b V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.2 DC Generator Operation The induced oltage is connected to the generator terminals through the commutator and brushes. In Figure 11A, the induced oltage in b is positie, and in a is negatie. The positie terminal is connected to commutator segment 2 and to the conductors in slot b. The negatie terminal is connected to segment 1 and to the conductors in slot a. S b 1 2 B a 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S a 30 1 2 B b V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.2 DC Generator Operation When the coil passes the neutral zone: Conductors in slot a are then moing toward the south pole and cut flux lines exiting from the rotor Conductors in slot b cut the flux lines entering the in slot b. This changes the polarity of the induced oltage in the coil. The oltage induced in a is now positie, and in b is negatie. S b 1 2 B a 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S a 30 1 2 B b V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.2 DC Generator Operation The simultaneously the commutator reerses its terminals, which assures that the output oltage (V dc ) polarity is unchanged. In Figure 11B the positie terminal is connected to commutator segment 1 and to the conductors in slot a. The negatie terminal is connected to segment 2 and to the conductors in slot b. S b 1 2 B a 30 V dc (a) Rotor current flow from segment 1 to 2 (slot a to b) S a 30 1 2 B b V dc (b) Rotor current flow from segment 2 to 1 (slot b to a)

2.3 DC Machine Equialent Circuit

Generator

2.3 DC Generator Equialent circuit The magnetic field produced by the stator poles induces a oltage in the rotor (or armature) coils when the generator is rotated. This induced oltage is represented by a oltage source. The stator coil has resistance, which is connected in series. The pole flux is produced by the DC excitation/field current, which is magnetically coupled to the rotor The field circuit has resistance and a source The oltage drop on the brushes represented by a battery

2.3 DC Generator Equialent circuit R f V brush R a Load Φ max V f I f E ag I ag V dc Mechanical power in Electrical power out Figure 12 Equialent circuit of a separately excited dc generator.

2.3 DC Generator Equialent circuit The magnetic field produced by the stator poles induces a oltage in the rotor (or armature) coils when the generator is rotated. The dc field current of the poles generates a magnetic flux The flux is proportional with the field current if the iron core is not saturated: Φ ag = K 1 I f

2.3 DC Generator Equialent circuit The rotor conductors cut the field lines that generate oltage in the coils. E ag = 2 The motor speed and flux equations are : r B l g D g Φ B l D = ω ag g g 2 =

2.3 DC Generator Equialent circuit The combination of the three equation results the induced oltage equation: The equation is simplified. ( ) ω ω ω ag r g g r g g r g r ag D B D B B E Φ = = = = l l l 2 2 2 ω ω ω f m f r ag r ag I K I K E = = Φ = 1

2.3 DC Generator Equialent circuit When the generator is loaded, the load current produces a oltage drop on the rotor winding resistance. In addition, there is a more or less constant 1 3 V oltage drop on the brushes. These two oltage drops reduce the terminal oltage of the generator. The terminal oltage is; E = V + I R + ag dc ag a V brush

Motor

2.3 DC Motor Equialent circuit R f V brush R a Electrical power in V f I f Φ max E am I am V dc DC Power supply Mechanical power out Figure 13 Equialent circuit of a separately excited dc motor Equialent circuit is similar to the generator only the current directions are different

2.3 DC Motor Equialent circuit The operation equations are: Armature oltage equation V = E + I R + V dc am am a brush The induced oltage and motor speed s angular frequency E = am K m I f ω ω = 2π n m

2.3 DC Motor Equialent circuit The operation equations are: The combination of the equations results in K m I f ω = E am = V dc I am R m The current is calculated from this equation. The output power and torque are: P = E I out m am f out am am P T = = ω K I I

2.4 DC Machine Excitation Methods

DC Motor Operation There are four different methods for supplying the dc current to the motor or generator poles: Separate excitation; Shunt connection Series connection Compound

2.3 DC Motor Equialent circuit V brush R a E am Φ max I am R f I m DC Power supply V dc I f P out Figure 14 Equialent circuit of a shunt dc motor

2.3 DC Motor Equialent circuit V brush R a E am R f I m DC Power supply Φ max V dc P out Figure 15 Equialent circuit of a series dc motor

2.3 DC Motor Equialent circuit V brush R a E am R fs I am I m DC Power supply Φ max V dc R fp I fp P out Figure 16 Equialent circuit of a compound dc motor