Transient Current Measurement for Advance Materials & Devices

Similar documents
CX3300 Series Device Current Waveform Analyzer

CX1100 Series Current and Differential Sensors

Keysight Technologies Accelerate Debug And Evaluation Of IoT Devices By Current Profile Analysis. Application Note

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Next Generation Curve Tracing & Measurement Tips for Power Device. Kim Jeong Tae RF/uW Application Engineer Keysight Technologies

What Is An SMU? SEP 2016

Keysight Technologies Pulsed-IV Parametric Test Solutions. Selection Guide

New Wide Band Gap High-Power Semiconductor Measurement Techniques Accelerate your emerging material device development

Receiver for Optical Distance Measurement

PXIe Contents. Required Software CALIBRATION PROCEDURE

Effect of Aging on Power Integrity of Digital Integrated Circuits

GATE & DRAIN Probe heads specifications

Keysight Technologies PNA-X Series Microwave Network Analyzers

The Practical Limitations of S Parameter Measurements and the Impact on Time- Domain Simulations of High Speed Interconnects

Micropower, Single-Supply, Rail-to-Rail, Precision Instrumentation Amplifiers MAX4194 MAX4197

Keysight Technologies Pulsed-IV Parametric Test Solutions. Selection Guide

Keysight Technologies Characterizing Random Noise in CMOS Image Sensors

Customized probe card for on-wafer testing of AlGaN/GaN power transistors

PART TOP VIEW V EE 1 V CC 1 CONTROL LOGIC

SiTime University Turbo Seminar Series

Measurement and Analysis for Switchmode Power Design

Pulse Timing and Latency Measurements Using Wideband Video Detectors

RF Measurements You Didn't Know Your Oscilloscope Could Make

Experiment 1: Instrument Familiarization (8/28/06)

TLP/VF-TLP/HMM Test System TLP-3010C/3011C Advanced TLP/HMM/HBM Solutions

Customized probe card for on wafer testing of AlGaN/GaN power transistors

HA-2600, HA Features. 12MHz, High Input Impedance Operational Amplifiers. Applications. Pinouts. Ordering Information

1KV PIV. High Voltage Pulsed IV measurements. Inovative Test System AMCAD ENGINEERING. June 2013

Optimize Wireless Device Battery Run-time

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

Electrical characterization of Graphene and nano-devices. Stewart Wilson European Sales Manager Semiconductor Parametric Test Systems Autumn 2014.

781/ /

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

Current sensor by IZM

Introduction to Oscilloscopes Instructor s Guide

Understanding Probability of Intercept for Intermittent Signals

Ultra-Fast I-V Module for the Model 4200-SCS

On-Wafer Measurement and Analysis of Flicker Noise and Random Telegraph Noise

Improving Amplitude Accuracy with Next-Generation Signal Generators

Switched Mode Power Supply Measurements

Experiment 1: Instrument Familiarization

KM4110/KM mA, Low Cost, +2.7V & +5V, 75MHz Rail-to-Rail Amplifiers

350MHz, Ultra-Low-Noise Op Amps

Agilent N3300 Series DC Electronic Loads

Wide band gap, (GaN, SiC etc.) device evaluation with the Agilent B1505A Accelerate emerging material device development

Keysight B1500A Semiconductor Device Analyzer. Data Sheet

Ultra-Fast NBTI/PBTI Package for the Model 4200-SCS

Keysight Technologies How to Make the Best Switch Mode Power Supply Measurements. Application Note

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

2520 Pulsed Laser Diode Test System

Power Consumption Measurement Techniques

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

Guide Version Five techniques for fast, accurate power integrity measurements

TPH3207WS TPH3207WS. GaN Power Low-loss Switch PRODUCT SUMMARY (TYPICAL) Absolute Maximum Ratings (T C =25 C unless otherwise stated)

Advances in RF and Microwave Measurement Technology

AP034-OM-E Rev D ISSUED: January 2000 ²

Traceability for Oscilloscopes and Oscilloscope Calibrators

Pulsed VNA Measurements:

Precision, Very Low Noise, Low Input Bias Current, Wide Bandwidth JFET Operational Amplifiers AD8512

400MHz, Ultra-Low-Distortion Op Amps

Understanding RF and Microwave Analysis Basics

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Getting the most out of your Measurements Workshop. Mike Schnecker

MAKING TRANSIENT ANTENNA MEASUREMENTS

EPAD OPERATIONAL AMPLIFIER

Measuring Stray Voltage. Steady state

Application Note Model 765 Pulse Generator for Semiconductor Applications

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

QUAD 5V RAIL-TO-RAIL PRECISION OPERATIONAL AMPLIFIER

Non-Volatile Memory Characterization and Measurement Techniques

AN-742 APPLICATION NOTE One Technology Way P.O. Box 9106 Norwood, MA Tel: 781/ Fax: 781/

Agilent dc Electronic Loads Models N3300A-N3307A

OBSOLETE. Parameter AD9621 AD9622 AD9623 AD9624 Units

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Dual, Audio, Log Taper Digital Potentiometers

Variable-Gain High Speed Current Amplifier

Welcome! Device Characterization with the Keithley Model 4200-SCS Characterization System.

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Measurement Techniques

Keysight B1500A Semiconductor Device Analyzer. Data Sheet

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Single Supply, Low Power Triple Video Amplifier AD813

Current sensor demonstrator by IZM

CD22202, CD DTMF Receivers/Generators. 5V Low Power DTMF Receiver. Features. Description. Ordering Information. Pinout. Functional Diagram

ECE 2274 Lab 2 (Network Theorems)

A 4 GSample/s 8-bit ADC in. Ken Poulton, Robert Neff, Art Muto, Wei Liu, Andrew Burstein*, Mehrdad Heshami* Agilent Laboratories Palo Alto, California

Keysight Technologies Device Current Waveform Analyzer

A DESIGN EXPERIMENT FOR MEASUREMENT OF THE SPECTRAL CONTENT OF SUBSTRATE NOISE IN MIXED-SIGNAL INTEGRATED CIRCUITS

Agilent 3000 Series Oscilloscopes. User s and Service Guide

On-wafer GaN Power Semiconductor Characterization. Marc Schulze Tenberge Manager, Applications Engineering Maury Microwave

APPLICATION NOTE 3942 Optimize the Buffer Amplifier/ADC Connection

Agilent Technologies Gli analizzatori di reti della serie-x

FHP3350, FHP3450 Triple and Quad Voltage Feedback Amplifiers

1. High Frequency Performance

Power Quality Measurements the Importance of Traceable Calibration

TAKE THE MYSTERY OUT OF PROBING. 7 Common Oscilloscope Probing Pitfalls to Avoid

ADA485-/ADA485- TABLE OF CONTENTS Features... Applications... Pin Configurations... General Description... Revision History... Specifications... 3 Spe

HA MHz, High Slew Rate, High Output Current Buffer. Description. Features. Applications. Ordering Information. Pinouts.

AC : EVALUATING OSCILLOSCOPE SAMPLE RATES VS. SAM- PLING FIDELITY

Transcription:

& Devices 8 May 2017 Brian YEO Application Engineer Keysight Technologies

Agenda 2 High speed data acquisition basics Challenges & solutions for transient current measurement. Considerations when making on-wafer transient current measurement Advance material and device characterization Summary

High-Speed Data Acquisition Basics 3

Measurement Value Steady-State vs Transient Measurement Steady-State Static measurement Easy to measure Wait sufficiently for signal to stabilize before making measurement Long duration steady-state allows for long integration time to improve measurement accuracy Transient Dynamic Measurement Difficult to measure Short transient duration Fast acquisition sacrifices accuracy Transient Steady-State time 4

Real-Time Sampling What Real-Time sampling works ADC converts analog waveform to digital data points at rate asynchronous to input waveform data rate Conversion rate is known as sampling rate Sample rate is derived from internal clock signal Input Signal Sample Clock Trigger Signal t s Sample Rate = 1 t s Reconstructed waveform 5

Factors Affecting Transient Measurement Term Bandwidth Definition Frequency at which a signal is attenuated by 3 db Sample Rate Rate at which the signal is digitized Memory Depth Amount of memory allocated to a waveform record Acquisition Time Amount of time to acquire waveform 6

Steady-State vs Transient Measurement Steady-State & Transient Harmonics Freq Steady-State Freq Transient 7

Factors Affecting Transient Measurement Bandwidth Sufficient BW Freq Accurate Result Signal Freq Insufficient BW Inaccurate Result 8

Factors Affecting Transient Measurement Bandwidth 1+3+5+7+ 39 Harmonic 1st Harmonic Original Signal 9

Factors Affecting Transient Measurement Required bandwidth depends on edge speed t r t r Edge Rate is the key determinant when selecting bandwidth 10

Factors Affecting Transient Measurement Required bandwidth depends on edge speed Step #1: Determine fastest rise/fall times of device-under-test. Step #2: Determine highest signal frequency content (f knee ). f knee = 0.5/RT (10% - 90%) f knee = 0.4/RT (20% - 80%) Step #3: Determine degree of required measurement accuracy. Step #4: Calculate required bandwidth. Required Accuracy Gaussian Response Maximally-flat Response 20% BW = 1.0 x f knee BW = 1.0 x f knee 10% BW = 1.3 x f knee BW = 1.2 x f knee 3% BW = 1.9 x f knee BW = 1.4 x f knee 11

Factors Affecting Transient Measurement Required bandwidth depends on edge speed 60 MHz 100 MHz 350 MHz 500 MHz 12

Factors Affecting Transient Measurement Overall bandwidth System bandwidth can be viewed as a chain, where the lowest bandwidth component in the measurement system will limit the bandwidth of the measurement. Fixtures/ Cables Probe Instrument BW effective = 1 BW 1 2 1 + 1 BW 2 2 + 1 BW n 2 13

Attenuation Factors Affecting Transient Measurement Effects of sample rate 0dB -3dB BW Aliased Frequency Components SR=2.5*BW SR=4*BW Frequency 14

Challenges & Solutions For Transient Current Measurement 15

Fast Low-Current Measurement Challenges Digital Multi-Meter Viable solution to measure current down to 1mA Connection Setup Using DMM Sufficient resolution (>16-bits) Current accuracy is calibrated Current Flow Bandwidth is <100 khz, insufficient to capture current transients in time domain DMM 16

Fast Low-Current Measurement Challenges Using An Oscilloscope Current probe limited sensitivity >1mA Shunt resistor limits sensitivity and bandwidth Limited resolution (ADC from 8 to 12 bits) High noise floor due to wide bandwidth Current Probe 17

Fast Low-Current Measurement Challenges Limitations with shunt-resistor DUT Parasitic capacitance R C par i T r = 2.2*CR 1 MΩ, 10 pf 22 ms (16 khz) Larger shunt resistance improve sensitivity, but it increases parasitic capacitance which limits the bandwidth Not feasible to switch shunt resistances due to current level changes for optimal sensitivity Current sensitivity is limited by noise floor of oscilloscope 18

New Solution To Measure CX3300 Device Current Waveform Analyzer Wide Dynamic Range 14-bit / 16-bit Hardware ADC Wide Bandwidth Fast Sampling Max. 200 MHz 1 GSa/s Low Noise Measurement 150 pa ~ 10 A Analysis Functions CCDF, FFT, Automatic Current Profiler, etc. 19

CX3300 Current Sensors & Heads Basic current sensor A1 CX1101A Current Sensor, Single Channel 100 MHz max bandwidth 40 na to 10 A +/- 40 V Common mode voltage Sensor Head required More dynamic range More BW & lower noise A1 A2 CX1102A Current Sensor, Dual Channel 100 MHz max bandwidth 40 na to 1 A +/- 12 V Common mode voltage A1 CX1103A Current Sensor, Low Side 200 MHz max bandwidth 150 pa to 20 ma +/- 0.5 V Common mode voltage Sensor Head required 20

CX3300 Sensor Head Connector Type SMA CX1201A CX1202A (with a voltage monitor) CX1203A Furnished with CX1101A and CX1102A CX1204A (shielded twisted pair) CX1205A (test leads) CX1206A Banana plug for 10 A measurement 21

Advance CX3300 Current Sensors Conventional Current Shunt DUT CX3300 Current Sensors DUT Low noise amplifier i R i Trade-off between sensitivity and bandwidth Oscilloscope s noise floor limits sensitivity Single resistor limits measurable range High-Frequency Low Current Sensing Circuit Advance sensor technology enables simultaneous wide bandwidth, low current measurement Sensor and mainframe combine to optimize bandwidth, sensitivity and low noise Multiple current ranges supported by the sensors provide wide dynamic range. 22

CX3300 Effective Measurement Bandwidth BW effective = 1 BW sensor 2 + 1 1 BW mainframe 2 Sensor Sensor Max BW Mainframe Max BW Effective Measurement BW CX1101A 100 MHz ~ 90 MHz CX1102A 100 MHz 200 MHz ~ 90 MHz CX1103A 200 MHz ~ 140 MHz 23

CX3300 Performance vs Current Probe Competitor Current Probe + 12-bit Oscilloscope CX3300 Device Current Waveform Analyzer 100 µs/div 1 ma/div 100 µs/div 1 ma/div?? CX1101A (20 ma range) RMS Noise: 250 µa Bandwidth 100 MHz RMS Noise: 20 µa Bandwidth: 100 MHz 24

CX3300 Measurement Performance Pulsed Measurement 100 µa current pulse measured in less than 100 ns 20 ns 100 µa Useful for NVM cell transient characterization 25

CX3300 Measurement Performance Advantages of 14/16-bit resolution This area can be magnified. 40 ma 10 μa Anywhere Zoom 26

Considerations when making transient current measurement onwafer 27

On-Wafer Measurement Considerations Chuck Capacitance Wafer Chuck Chuck to ground capacitance (>1000 pf) - Chuck will charge up with left floating and substrate potential may be unstable during measurement - If pulse generator unit (PGU) is connected to the chuck then it will have long settling time due to the large chuck capacitance Difficult to change chuck voltage quickly Vtop - Use shorting plug to ground wafer chuck (do not leave it floating!) - If chuck requires bias, keep voltage constant throughout measurement Vchuck Alternate method Vtop Vchuck 28

On-Wafer Measurement Considerations Probe Contact Resistance High contact resistance and parasitic capacitance degrade pulse shape (significantly) High contact resistance reduces both the pulse amplitude and the current flowing into the DUT Maintain low contact resistance is critical for pulsed measurements 29

On-Wafer Measurement Considerations Cable Capacitances Measured I d A 50 W I d Measurement Distortion Cable charging current Rising Edge A 50 W Actual I d less than measured by instrument Falling Edge One way to avoid this issue (other than using short cables) is to measure current at low side as it is close to a stable voltage (zero volts). 30

On-Wafer Measurement Considerations Typical Setup Current measurement instrument Parameter analyzer or pulse generator unit (PGU) Shorten the cables as much as possible, and be sure to connect up the circuit common. A 3D positioner is helpful to fix the sensor. 31

On-Wafer Measurement Considerations DC Probe Connections To measurement equipment 16493R-101 or 102 To measurement equipment 16493R-202 SSMC(Plug) SMA(m) 200 mm 16493R-202 SSMC(Plug) SMA(m) 200 mm Establishes return path for Gate pulse Advantages: Cheaper than RF probes Bandwidth OK for CX3300 Flexible pad layouts Terminates Well and Source Establishes return path for Drain Current Disadvantages: Minimum achievable pulse width ~100 ns Mechanical tension created on probes Not supported by all prober companies 32

On-Wafer Measurement Considerations Actual DC Probe Setup Keep cables as short as possible Connect shields together using a cable to maintain the circuit common and to provide a current return path Current sensor Signal from PG 33

On-Wafer Measurement Considerations Shielding to reduce noise Problem: Measurement result is very noisy. External noise from power line, light, electromagnetic waves, etc. prevents accurate measurement. It infiltrates the measurement path via capacitive coupling. Solution: Shield measurement circuit to prevent external noise from permeating the measurement. Shield must be grounded. 34

On-Wafer Measurement Considerations Unshielded Shielded 35

Advanced Material & Device Characterization 36

Device Trends: Lower Power & Higher Speed Advance devices require low-current measurement Examples of innovative devices: Non Volatile Memory (NVM):ReRAM, PRAM, etc. Wide Band Gap Semiconductor: SiC, GaN, etc. Organic devices: OLED, OTFT, etc. Trend and changes for innovative devices: Device characteristics are varied by the timing of the measurement - Time domain current measurement and analysis are becoming important to accelerate device development and debug. Devices are becoming lower power and higher speed. - Need to measure fast low current waveforms to understand the current profile of the low power devices 37

Current Advance Material Characterization ReRAM, PRAM ReRAM Set and Reset Cycle Set <100ns Read <100ns Non-transistor based NVM cell characterization requires current measurements faster than 100 ns and lower than 1 ma. 38

Advance Material Characterization What are Advanced Non-Volatile Memory Cells These devices consist of special materials and have complex operating mechanisms. To understand device behavior, it is important to measure current flow characteristics between two electrodes. FeRAM PRAM ReRAM Emerging NVM positioning 39

Advance Material Characterization Challenges in characterizing advance NVM cells Voltage pulse for ReRAM evaluation Difficult to measure transient current in this short pulse Existing analyzers can measure current here, but < 100 ns < 100 ns Difficult to measure transient current in this short pulse Pulse width: 10 ns to 100 ns Dynamic current: from 1 μa level 1 μa measurement under > 100 MHz BW 40

Advance Material Characterization PRAM cell measurement using CX3300 Triangular voltage CX1102 dual channel sensor is used for this measurement. 2 V/div 2 ma/div CX3300 visualizes the phase change by the triangular voltage 2 μs/div Blue : 20 ma range (primary) Magenta: 200 μa range (secondary) 10 μa/div Secondary range captures the behavior in low current domain 41

Advance Material Characterization Conventional Power Transistor SI & SiC Si & SiC transistors do not have memory Drain Voltage OFF ON OFF ON Drain Current Time 42

Advance Material Characterization GaN transistors GaN transistors remember how long they are in the off state Short Stress Long stress Drain Voltage OFF ON OFF ON Drain Current Time Transient analysis is required to improve performance and reliability 43

Advance Material Characterization GaN Current Collapse Measurement Vd off 100 µs Vd off 8.5 ms Pulse Width = 1.5 ms 10 V/div Vd off: 40 V Vd on: 1 V Vg 2 ms/div Current collapse transient can be measured. 1 ma/div Id 44

Advance Material Characterization GaN Current Collapse Measurement Vd off 100 ns Vd off 8.5 μs Pulse Width = 1.5 μs 10 V/div Vd off: 40 V Vd on: 1 V 2 μs/div 1 ma/div Vg Id Current response captured with 1 ns sampling rate 45

Advance Material Characterization Organic Thin Flim Transistor (OTFT) Improving carrier mobility is one of the key challenges. Need to measure the current levels ranging from na to µa. Switching of OTFT Frequency 1 khz to 10 MHz Vg Id S D OTFT G Current: 1 na to 100 ma 46

Summary 47

Summary Key Takeaways Total measurement bandwidth is a function of the bandwidth of the individual elements of the measurement setup Conventional measurement instrumentation can measure transient currents down to ~1 ma; smaller current levels require an advance instrument like the CX3300 It is important to take into account all elements (wafer chuck, cables, probes, etc.) of the system when performing high-speed current/voltage measurements on wafer. The CX3300 offers advance capabilities not found on any other high-speed current measurement solution and is especially useful in characterizing many new types of materials and devices. 48

Additional Information www.keysight.com/find/cx3300 49

Questions & Answers 50