Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Similar documents
Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies Measuring Power BJT Electrical Characteristics using the B1505A

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies

Keysight Technologies

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies 1500 A and 10 kv High-Power MOSFET Characterization using the Keysight B1505A

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Pulsed-IV Parametric Test Solutions. Selection Guide

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies Power of Impedance Analyzer

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies Photodiode Test Using the Keysight B2980A Series

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies USB Preamplifiers

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies Medalist i1000d Boundary Scan Debug

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer. Application Note

Keysight Technologies Solid State Switches. Application Note

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Introduction. Part 1. Introduction...2

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies Making Fuel Cell AC Impedance Measurements Utilizing N3300A Series Electronic Loads. Application Note

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies Characterizing Random Noise in CMOS Image Sensors

The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 khz a capability typically found

Keysight Technologies Pulsed-IV Parametric Test Solutions. Selection Guide

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Precise Evaluation of Input, Output, and Reverse Transfer Capacitances of Power Devices. White Paper

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A

Keysight Technologies N9063A & W9063A Analog Demodulation

Keysight Technologies x1149 Boundary Scan Analyzer. Data Sheet

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Introduction. Part 1. Introduction...2

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters. Data Sheet

Keysight Technologies Maximizing the Life Span of Your Relays

Keysight N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies A Flexible Testbed to Evaluate Potential Co-Existence Issues Between Radar and Wireless

Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus

Transcription:

Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement Using Keysight B1500A Semiconductor Device Analyzer Application Note

Introduction Recently, the post silicon new devices and materials, such as wide band gap devices (SiC, GaN), nano devices, organic devices and so on, are intensively researched. It is highly demanded to satisfy the requests of high performance, energy saving and cost saving for the next generation products. To introduce it into the market timely with matured quality, it is very important to understand its characteristics and improve the device production processes. Particularly for MIS/MOS structure devices, the interface status is one of the important evaluations to reduce the defect and improve the device quality for yield and product assurance viewpoints. As well as the silicon technology, the analysis of the interface state is demanded for the new devices and new process technology. To analyze the interface state, the quasi-static capacitance voltage (QSCV) measurement technique has been the most popular method. The AC signal-based high frequency capacitance voltage (HFCV) measurement (about up to 1 MHz range) is widely used for the new materials and devices characterization, however the interface state analysis cannot be evaluated only by the HFCV measurement, because the slow interface state in-between two materials does not respond to the high frequency AC signal of HFCV. To analyze such slow state traps, the QSCV measurement technique has been widely used, which is effective for capturing a slow frequency behavior as shown in Figure 1. The QSCV measurement uses linear DC ramp sweep or DC step voltage instead of an AC signal, and also needs very low current measurement technique. It is a unique measurement method, and it is very important to understand measurement knowledge and know-hows for performing the measurement appropriately. This application note discusses the key points in the QSCV measurements including the issues, knowhows and tips when performing the QSCV measurements using the Keysight B1500A Semiconductor Device Analyzer/EasyEXPERT software. The following topics are covered in this application note. 1. Basics of QSCV measurement. 2. Keysight B1500A QSCV solution 3. Set-up and tips for QSCV measurement by the Keysight B1500A Note: The HFCV measurement which is a counter part of the QSCV measurement is discussed in the other application note. Refer to Capacitance Measurement Basics for Device/Material Characterization, if you are interested in the HFCV application, too. QSCV HFCV Figure 1. QSCV capture the slow response that cannot be measured by HFCV

3 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Basics of QSCV Measurement The QSCV measurement seeks the capacitance value by using the basic relationship between current I, voltage V, capacitance C and charge Q as shown in Figure 2. Although they are basically the same, there are two basic formulas, according to the focused variables. Figure 2(a) shows a basic formula of C=Q/V. From this formula, the capacitance can be obtained as the function of the voltage step and the amount of the charge applied by the voltage to capacitor. Figure 2(b) shows another formula, which is C=Q/V=IT/V=I/(V/T). The total amount of the charge Q can be expressed by the current integrated for a period of time T as Q= IT. From this formula, the capacitance can be obtained as the function of current I, voltage V and time T. Here, the V/T equals to the voltage ramp rate, so the capacitance can be obtained by the current and voltage ramp rate inally. In the following sections, two basic QSCV measurement methods by using these formulas are introduced. V (voltage) Q (charge) C (capacitance) C= Q/V (a) Basic formula of C, Q and V V v V/ T = V (ramp voltage) t T I Q=I x T C C= Q/V = I x T/V I = ( V/ T) (b) Basic formula of C, I, V and T Figure 2. Basic formula for QSCV measurement Linear voltage ramp The linear voltage ramp method is a traditional measurement method of the QSCV since its start in the late 60 s. It uses the linear voltage ramp as shown in Figure 2(b). This has been a very common method, because it simply applies the voltage at a ixed ramp rate ( V/ T) and measures the current. Unlike the step V method described later, it is not necessary to consider and control the timing precisely for the Q integration. However, some devices may have the leakage current such as electron tunneling through the gate dielectric or p-n junction. In this case, the leak current is also measured as a part of the current I in the Q= I/(V/T) formula. Because the leak current is not related to the traps, the interface state cannot be analyzed accurately for such devices as the result.

4 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Step voltage method The step voltage method measures the capacitance by using the formula of C=Q/V as shown in Figure 3. The amount of the charge Q is obtained by the relationship of step voltage V, transient current, and time. The measurement time (integration time) must be set to cover all the transient charge current to obtain the Q accurately. This method is not only limited to single step, but it can be also performed in the voltage sweep and the Q can be obtained in each step. I V V A Q = = I x T V C I V Q =I x T t Voltage sweep T C = Q/ V = I x T/ V Measurement Time ( T) t Figure 3. Step voltage QSCV measurement. Keysight B1500A QSCV Solution B1500A enables advanced step voltage QSCV measurement The Keysight B1500A Semiconductor Device Analyzer is widely used in the device characterization, and you can perform QSCV measurement in addition to all the current-voltage (IV) measurement, CV measurement and pulsed measurement in one instrument. The B1500A provides the graphical-user-interface (GUI) for easy-to-test without programming. The B1500A enables you to perform the QSCV measurement easily by using the built-in GUI based application test as shown in Figure 4. The following introduces the detailed features of the B1500A QSCV measurement solution. The B1500A supports the QSCV measurement by the Source/Monitor Unit (SMU). It enables the advanced step voltage QSCV method by the superior low current measurement down to 0.1 fa resolution and the intrinsic precise timing control. In addition, the B1500A and the application test for QSCV measurement implement the leak and offset compensations applicable to leaky device measurement as described later. Figure 4. Ready to use QSCV application test

5 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Details of the B1500A step voltage QSCV measurement The measurement diagram of B1500A QSCV measurement is shown in Figure 5. The basic idea of the B1500A's step voltage QSCV method is the same as Figure 3, but a few more parameters are added to adapt to various devices and to support advanced capabilities. The Figure 5(a) shows the entire CV sweep of QSCV measurement, and Figure 5(b) shows a magniied view of the a sweep step. More details of a QSCV measurement in a step are shown in Figure 5(c). In the original idea of the voltage step QSCV method as shown in Figure 3, the QSCV measurement is performed by the step voltage of CV sweep. However, in this case, the QSCV measurement parameter ( V) is ixed by the CV sweep settings of start V, stop V and number of sweep steps. Typically those parameters are deined by the device operating range from accumulation to inversion, and the number of points to plot the curve. So it limits the freedom to optimize the QSCV measurement parameters. In the B1500A QSCV measurement, the V of QSCV measurement can be set independently from the step voltage of the CV sweep as shown in Figure 5 (b). Along the CV sweep, any same or different V can be speciied for QSCV measurement across each sweep step voltage. At the beginning of the QSCV measurement, the voltage is set to (sweep step voltage Vstep-n - V/2). If necessary, it is possible to place the delay time to wait for the settling of charge current by CV sweep step voltage. Then the QSCV measurement is performed with V from (sweep step voltage Vstep-n - V/2) to (sweep step voltage Vstep-n + V/2), as shown in Figure 5(c). The charge Q induced by the V can be calculated by measuring the current and numerically integrating the area under the current versus time curve precisely inside of the B1500A. As a result, the capacitance at each step can be obtained by the formula of C= Q/ V along with any step voltage of CV sweep. V Nth QSCV meas. step Stop V Delay time V step of CV sweep Hold time Start time Start V ~ (a) Entire CV sweep for QSCV measurement (b) QSCV measurement in the step. Q C= Q/ V V Delay time (2) QSCV Integration time (1) Leak Integration time Leak current measurement (3) Leak Integration time Figure 5. Details of B1500A step voltage QSCV measurement (c) QSCV measurement detail

6 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Details of the B1500A advanced capabilities Leakage current compensation: If the device has the leakage current such as electron tunneling through the gate dielectric or p-n junction, it cannot be distinguished from the charge current for QSCV measurement. To reduce the error caused by those leakage currents, the B1500A QSCV measurement provides the advanced feature to compensate the leakage current. It measures the leakage current before and after the QSCV measurement as shown in igure 5(c), and then subtracting out the leakage current before calculating the Q for the capacitance. Since the above leakage current compensation is made by using the same current range which measures the QSCV current, the compensated maximum leak current is limited to the QSCV measurement current range. If the leak current is large, the leak current cannot be fully compensated. If the higher current range is used for the large leakage current, the QSCV measurement accuracy tends to be degraded. To resolve this challenge, the B1500A provides another leakage current compensation capability (I offset cancelation) by using additional SMU. This additional SMU is connected in parallel to force the current to cancel the large leak, enables to perform QSCV measurement in the appropriate range even with the large leak. It can be set up as shown "IOffsetCancel" in the center-right of igure 6. QSCV offset compensation: Offset capacitance and the leakage current can be the error (or parasitic) factors for QSCV measurement as shown in Figure 7. As well as HFCV measurement, stray capacitance between the measurement terminals is regarded offset capacitance (Coffset) to be compensated. In addition, the QSCV method calculates the capacitance from the charge current, so the leakage current (I_leak) without device is also contributed to the capacitance calculation. Unless these are appropriately compensated, the QSCV result can include some measurement errors. The B1500A supports both of these measurements to determine the offset capacitance and the leakage current while the test terminal is open. The I-leak offset current is also converted to offset capacitance C(I_leak) using the QSCV measurement parameters, and generates total offset capacitance Cmo in addition to Coffset. The Cmo is stored and automatically subtracted from subsequent QSCV measurements (Cm), and you can get the compensated result. The offset measurement GUI is shown in Figure 8. The current measurement SMU (IMeasSMU) and the current measurement range (MeasRange) have to be the same for accurate Coffset compensation. Figure 6. I offset cancel capability I_leak Cmo Coffset I_leak Cm Coffset Cx Cmo = Coffset + C(I_leak) Cx = Cm - Cmo Figure 7. offset capacitance compensation. Figure 8. offset capacitance measurement GUI.

7 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Parameters in the application test In the B1500A QSCV application test, you can control the following parameters in the GUI in Figure 9. CV sweep setup parameters: Start V, Stop V, Step V: CV sweep parameters. Refer to Figure 5. I_comp: Current compliance of SMU. HoldTime: Wait time before starting the CV sweep at the irst bias voltage. Refer to igure 5(a). QSCV measurement setup parameters: IMeasSMU: SMU to measure the charge current for QSCV. MeasRange: Current range of SMU to measure the charge current for QSCV. Integ_C: Integration time for Q for QSCV. Refer to Figure 5(c). QSCVMeasV: Step voltage V for QSCV. Refer to Figure 5(c). DelayTime: Delay time before starting the QSCV measurement at each CV sweep step. Refer to Figure 5(c). Leakage current compensation setup parameter LeakCompen: Switch to enable/disable the leak compensation. Integ_L: Integration time for leakage current measurement. I offset cancelation capability IOffsetCancel: Switch to enable/disable the I offset cancel capability IOffsetSink: Specify the SMU to connect in parallel to the "IMeasSMU In the following section, the setup method of these parameters is discussed. Figure 9. GUI and setting parameters for QSCV measurement

8 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Set-up and Tips for QSCV Measurement by the B1500A This section provides several useful information to setup QSCV parameters and tips for accurate measurement to meet in various situations. There is a deep relation between the integration time setting, current range setting, leakage current setting and the capacitance value in the QSCV measurement, and the explanation starts from these relations. Typical steps for successful QSCV measurement setups The step voltage QSCV test setup can be made easier if the measurement starts from the DC and HFCV measurement as shown in Figure 10. The B1500A supports the seamless measurement among the IV and QSCV measurement by SMU and HFCV measurement by the CMU (Capacitance Measurement Unit) with the optional SCUU (SMU CMU Unify Unit) as shown in Figure 11. This enables you to perform accurate HFCV and QSCV measurement quickly and effortlessly. Through the DC and HFCV measurements, the following useful information can be obtained for QSCV measurement. DC measurement to know leakage current: DC leakage current information is useful for determining the minimum QSCV measurement range. It can also be useful for determining if the DC leak compensation function is used. HFCV measurement to know maximum capacitance value: If the capacitance value can be known roughly in advance, you can set the various parameters such as QSCV measurement range, step voltage and integration time smoothly. This is described later in detail. DC sweep meas. HFCV meas. QSCV setup Initial QSCV measurement: DC leak compensation = OFF Delay time = 0 Integ C time = by requirement QSCV Meas. V = Sweep step V Figure 10. Typical QSCV test setup low. Max. DC leakage current: Set minimum QSCV I range Max. capacitor value: Set QSCV meas. V, Integ C time and the QSCV I range SMU1 SMU2 SCUU SMU1 or CMU-H Hp GSWU Device CMU Hc control Lp SMU2 or CMU-L Figure 11. SCUU diagram Lc GSWU:Guard Switch Unit How to set the QSCV measurement parameters The following section provides the information how to set the measurement parameters appropriately. For the details, refer to the graph of maximum measurement value in "QSCV Maximum Measurement Value and Accuracy" of the EasyEXPERT user's guide. That graph shows the maximum capacitance value by the combination of the parameters such as the range, step voltage and integration time.

9 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note Set longer QSCV integration time than the graph of maximum measurement value: The graph of maximum measurement value in the user s guide shows the measurement limitation of the maximum capacitance that can be measured at the combination of parameters, as shown in Figure 12 and 13 as the examples. According to your capacitance value, this graph provides the good starting point of C integration time (Integ_C) at speciic V. For example, if the 1 nf capacitance is measured at 0.1 V step, the graph shows the 100 ms as the minimum C integration time. So set the C integration time larger than this value. If the QSCV measurement fails, the compliance state "C" or overlow status "V" is shown in the data status, and then try a longer integration time. Start the measurement range equal to or larger than 1 na range: The 1 na and higher ranges allow larger capacitance measurement, so it is recommended to start from 1 na range. As shown in the Figures 12 and 13, the maximum capacitance value is a function of V as well as C integration time. If the V is from 0.1 V to 0.2 V, the 1 na range allows up to 10 nf, but 10 pa/100 pa allows up to 10 pf approximately at 1 s C integration time. If the capacitance is known small appropriately for 10 pa/100 pa ranges, of course those ranges can be used. After starting the parameter combination on this graph, and then adjust those parameters according to the device characteristics. Figure 12. Maximum measurement value by parameter combination (1 na range). Figure 13. Maximum measurement value by parameter combination (10 pa and 100 pa ranges). Additional notes to measure the device with slow interface state: When measuring the device with slow interface state, pay more attention to the C integration time. Due to the slow interface state, the value of device capacitance can be shifted during the measurement, and the charge current is slowly settlled down. To characterize the device with accurate Q, it is important to integrate the charge current enough by the end of the settling, which has its time constant. To integrate the charge current by settling within about 5 %, the C integration time needs to be longer than approximately three times the time constant of the QSCV response, in the time constant matter. For most cases, the integration time from 5 s to 10 s is enough at maximum, in case the leak compensation is disabled. When the leak compensation is enabled for a leaky device, adjusting the C integration time becomes more important to fully integrate the charge current. If a longer C integration time is necessary, adjusting the L integration time sometimes provides better results. To obtain a satisfactory result, it may be necessary to adjust the parameters by try and error of repeat measurements by comparing the data. When the CV sweep step is larger than the V of QSCV measurement, adjust the delay time as well. The charge current of slow state caused by the CV sweep might not be settled down yet at the QSCV measurement.

10 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note How to use the leak compensation The step voltage QSCV test setup can be made easier if the measurement starts from the DC and HFCV measurement as shown in Figure 10. The B1500A supports the seamless measurement among the IV and QSCV measurement by SMU and HFCV measurement by the CMU (Capacitance Measurement Unit) with the optional SCUU (SMU CMU Unify Unit) as shown in Figure 11. This enables you to perform accurate HFCV and QSCV measurement quickly and effortlessly. Through the DC and HFCV measurements, the following useful information can be obtained for QSCV measurement. Enable the leak compensation for leaky device: The QSCV measurement is very susceptible to the leakage current of the device, and it is important to know the level of the leakage current. Figure 14 shows the comparison of the QSCV measurements and the HFCV measurment made on a varicap diode with the same sweep condition. The QSCV measurements are made in two different conditions; one is leak compensation ON and the other is OFF condition. The device shows leakage current as shown in the graph, and the QSCV curves show quite different results. The QSCV curve measured under the leak compensation ON data correlates well to the reference HFCV measurement curve. As you can see this example, the leak current compensation function is very useful especially when measuring the leaky device. Normally, the measurement can be started from the leak compensation OFF, and then try ON according to the measurement result. If the device is known as leaky device, set the leak compensation ON from the beginning. Figure 14. The effect of leak compensation and the correlation with the HFCV measurement. Set appropriate integration time for the leak measurement: The parameter of Integ_L is the integration time for the leak current measurement. The leak current is subtracted from the charge current during the C integration time at each CV sweep step. This feature provides the accurate QSCV data by eliminating the effect of leak current for leaky device, but it could add the unexpected error by noise from the device and SMU, unless it is appropriately set up. Obviously the unstable leak current measurement results in unstable QSC data, because the leak current is subtracted from the charge current of QSCV measurement. From this viewpoint, the leak measurement must be accurate enough and low noise relatively to the QSCV charge current measurement. Hence, it is recommended to use the 1 PLC (power line cycle) averaging for the integration time for leak current (Integ_L). Using the PLC multiplied integration time can reduce the power line oriented noise drastically.

11 Keysight How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement - Application Note How to reduce the noise in the QSCV measurement Increase V for QSCV measurement: When the measurement data is noisy, try to use larger V. Since the amount of charge and its transient current are deined by the V, larger V induces larger charge current and it improves the signal to noise ratio. The V of 100 mv or 200 mv would be a good starting point for the QSCV measurement for most of cases. Use the SMU at gate for QSCV measurement: To measure the MOS/MIS cap, two SMU are used in the QSCV measurements as shown in Figure 15. SMU 1 is connected to the gate and SMU 2 is connected to the substrate. To reduce the noise, it is recommended to use the SMU at gate site for the current measurement for QSCV. The gate side is usually high impedance and less affected by the noise from the measurement environment. Choose the SMU to sweep the voltage: Whichever SMU connected to the gate or substrate can be a voltage sweep source. However, it is important to note that the effect of the stray capacitance Cg or Cs, as shown in Figure 15. In Figure 15(a), the voltage is swept and the charge current is also measured at gate side. In addition to the charge current to the device, the charge current (Is) into the stray capacitance (Cg) is also measured. This can be a measurement error. In Figure 15(b), on the other hand, there is no charge current into the stray capacitance (Cg), because the voltage remains the same at the gate side. Although these stray capacitance components can be cancelled by the offset capacitor compensation, it is recommended to choose the SMU to sweep the voltage carefully. In general, it is recommended to measure the QSCV at gate and sweep the voltage at substrate, as shown in Figure 15(b). I C C I Gate Subs Subs Gate A A SMU 1 SMU 2 SMU 2 SMU 1 Is Cg Cs V 0V Cs Cg V 0V Is=0 (a) V sweep in gate side (b) V sweep in Subs side Figure 15. Effect of the charge current into stray capacitance Conclusion The QSCV measurement is important application for evaluating new materials and devices and improving their performance and quality, as well as IV and HFCV measurement. The advanced QSCV measurement feature of B1500A enables wide range of materials and devices with the lexibility of various settings as discussed above. The B1500A provides all of the IV, CV and QSCV measurement and switching capabilities in the combination with the optional SCUU. The SCUU enables the B1500A to perform the IV and QSCV measurement by SMU and HFCV measurement by the CMU without changing the connection manually. The B1500A provides the total solution for QSCV and other fundamental IC/CV characterizations for various materials and devices.

12 Keysight Capacitance Measurement Basics for Device/Material Characterization - Application Note Keysight B1505A Power Device Analyzer/Curve Tracer (1500 A/10 kv) www.keysight.com/find/b1505a Keysight E5270B/E5260A Modular Source Measure Unit (SMU) www.keysight.com/find/msmu Keysight B2900A Series Precision Source/Measure Units (SMU) www.keysight.com/find/b2900a mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ ThreeYearWarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/ AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/ channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/b1500a For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) Keysight B2200A/B2201A/E5250A Low-leakage Switch Matrix www.keysight.com/find/swm This information is subject to change without notice. Keysight Technologies, 2014, 2015 Published in USA, January 23, 2015 5992-0436EN www.keysight.com