MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Similar documents
MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-f(-SP)

MACX MCR-UI-UI-UP(-SP)(-NC)

PHOENIX CONTACT

MINI-PS AC/24DC/1.3

PHOENIX CONTACT

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

QUINT-PS-24DC/24DC/10

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Extract from the online catalog

MINI-PS AC/2X15DC/1

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

PHOENIX CONTACT - 09/2009

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Signal conditioner - MACX MCR-UI-UI-NC

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

QUINT-PS AC/24DC/40

PSD-S CE-TM SPRING. Connection element with spring-cage terminal blocks for tube mounting. Data sheet. 1 Description

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

VARIOCON. Modular Contact Inserts

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

KDS10/SO. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 3AC/24DC/10

PSD-S AE SM DB/1

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

Power supply CP-E 24/2.5

SLKK 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Power supply CP-E 24/0.75

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Power supply CP-D 24/1.3

Power supply CP-E 24/20.0

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power supply CP-D 12/2.1

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-E 24/2.5

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

PACT RCP-4000A-UIRO-Dxxx

UTTB 4. Extract from the online catalog. Order No.:

Coupling Relays and Converters

MKDS 3/ 4. Extract from the online catalog. Order No.:

DIK 1,5 General data Technical data General

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Power supply CP-D 24/4.2 Primary switch mode power supply

UTTB 2,5. Extract from the online catalog. Order No.:

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

QUINT-PS/ 1AC/24DC/20

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Three-phase monitoring relay CM-PFS

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

General data. Technical data DIKD 1,5. General. Dimensions

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

This data sheet is only valid in association with the IL SYS INST UM E user manual.

High-current terminal block - UKH

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

DEK-OV- 12DC/ 24DC/ 3

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

TRIO-PS-2G/1AC/24DC/5

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Installation and Operating Instructions for Phase Demodulator Type _.2

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Feed-through terminal block - PT 10-TWIN

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

AKG 4 GNYE. Extract from the online catalog. Order No.:

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Electronic timer CT-SDD.22

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Power supply CP-T 24/10.0 Primary switch mode power supply

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Power supply CP-T 24/40.0 Primary switch mode power supply

PSR-SCP- 24DC/ESD/5X1/1X2/300

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Instruction manual for STA 1 sectional door operator

Transcription:

Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into standard analog signals. Output signal: 4... 20 ma. Designation Input current Order No. MCR-SL-CUC-100-I 0... 100 A 2308027 MCR-SL-CUC-200-I 0... 200 A 2308030 MCR-SL-CUC-300-I 0... 300 A 2308043 MCR-SL-CUC-400-I 0... 400 A 2308072 MCR-SL-CUC-500-I 0... 500 A 2308085 MCR-SL-CUC-600-I 0... 600 A 2308098 Output signal: 0... 10 V Designation Input current Order No. MCR-SL-CUC-100-U 0... 100 A 2308108 MCR-SL-CUC-200-U 0... 200 A 2308205 MCR-SL-CUC-300-U 0... 300 A 2308302 Features Electrical isolation of input and output signals Contact-free measurement of live conductors Large input signal opening Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page:

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Safety notes and warning instructions... 5 6 Block diagram... 6 7 Structure... 6 8 Mounting... 6 9 Installation... 7 9.1 Power supply... 7 9.2 Connecting the cables... 7 10 Current monitoring... 7 104059_en_05 PHOENIX CONTACT 2

3 Ordering data Products Description Type Order No. Pcs./Pkt. 0... 100 A input current, 4... 20 ma output current 0... 200 A input current, 4... 20 ma output current 0... 300 A input current, 4... 20 ma output current 0... 400 A input current, 4... 20 ma output current 0... 500 A input current, 4... 20 ma output current 0... 600 A input current, 4... 20 ma output current 0... 100 A input current, 0... 10 V output voltage 0... 200 A input current, 0... 10 V output voltage 0... 300 A input current, 0... 10 V output voltage MCR-SL-CUC-100-I 2308027 1 MCR-SL-CUC-200-I 2308030 1 MCR-SL-CUC-300-I 2308043 1 MCR-SL-CUC-400-I 2308072 1 MCR-SL-CUC-500-I 2308085 1 MCR-SL-CUC-600-I 2308098 1 MCR-SL-CUC-100-U 2308108 1 MCR-SL-CUC-200-U 2308205 1 MCR-SL-CUC-300-U 2308302 1 Accessories Description Type Order No. Pcs./Pkt. Flat zack marker strip marking material (without color print, white) ZBF10:UNBEDRUCKT 0044187 1 DIN rail adapter for mounting the universal current transducer PACT MCR-RA 2277598 12 4 Technical data Input MCR-SL-CUC-100-I MCR-SL-CUC-200-I MCR-SL-CUC-300-I Nominal input current I IN 0 100 A 0 200 A 0 300 A Overload capacity 6 x I IN, maximum 3 x I IN, maximum 3.33 x I IN, maximum MCR-SL-CUC-400-I MCR-SL-CUC-500-I MCR-SL-CUC-600-I Nominal input current I IN 0 400 A 0 500 A 0 600 A Overload capacity 2.5 x I IN, maximum 3.6 x I IN, maximum 3 x I IN, maximum MCR-SL-CUC-100-U MCR-SL-CUC-200-U MCR-SL-CUC-300-U Nominal input current I IN 0 100 A 0 200 A 0 300 A Overload capacity 6 x I IN, maximum 3 x I IN, maximum 3.33 x I IN, maximum Frequency range DC, 20 6000 Hz Signal form Any Connection method Through connection of 32 mm Output MCR-SL-CUC-...-I MCR-SL-CUC-...-U Output signal I OUT 4 20 ma 0... 10 V Maximum output signal < 25 ma < 14 V Load < 300 Ω 10 kω Connection method FKCN 2.5/ 4-ST COMBICON connector 104059_en_05 PHOENIX CONTACT 3

Connection data Outside diameter of input Power supply/output conductor cross-section Solid (minimum/maximum) Stranded (minimum/maximum) Stranded with ferrule without plastic sleeve (minimum/maximum) Stranded with ferrule with plastic sleeve (minimum/maximum) AWG/kcmil (minimum/maximum) Stripping length (power supply/output) 32 mm Ø 0.2...2.5mm 2 0.2...2.5mm 2 0.25... 2.5 mm 2 0.25... 1.5 mm 2 24... 14 10 mm General data Supply voltage Supply voltage range U B Current consumption MCR-SL-CUC-...-I MCR-SL-CUC-...-U 24 V DC 20... 30 V DC 30 ma + I OUT 30 ma Power consumption At U Bmax = 30 V and I OUT = 25 ma 1.65 W Transmission error Under nominal conditions (25 C) < ±1% of range final value (I N ) Linearity error < ±1% of range final value (I N ) Temperature coefficient 0 60 C -40 65 C Step response (90% of I N ) Ambient temperature range Operation Storage Safe isolation according to EN 61010 Rated insulation voltage Test voltage Input/output Input/power supply Surge voltage category (measurement category according to EN 61010) ±3.2 µa/k ±6.4 µa/k 150 ms -40 C... +65 C -40 C... +85 C 300 V AC 3.5 kv, 50 Hz, 1 min. 3.5 kv, 50 Hz, 1 min. III Pollution degree 2 Degree of protection IP20 Dimensions (W x H x D) 90 mm x 70 mm x 33.8 mm Housing version Frianyl B63 V0 GV30 The current transducer housing meets the requirements of UL94-V0 regarding inflammability characteristics. Approvals UL, USA / Canada (does not apply to 2308085, 2308098) Conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC EMC requirements regarding noise immunity and noise emission EN 61326-1:2006 General requirements regarding electrical safety EN 61010-1:2001 104059_en_05 PHOENIX CONTACT 4

Dimensions (nominal sizes in mm) 10 90 71,2 Ø32 33,8 12,5 16 25 4,6 70 6 78 4,6 5 Safety notes and warning instructions Installation and startup must only be carried out by qualified electricians. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. In terms of these operating instructions, qualified personnel are electricians or persons with electrotechnical training as defined in VDE 0105 Part 1/DIN EN 50110-1. WARNING: Disregarding this warning may result in damage to equipment and/or serious personal injury. NOTE: Safe and error-free operation of this device can only be ensured if transport, storage, and assembly are carried out correctly and operation and maintenance are carried out with care. 104059_en_05 PHOENIX CONTACT 5

6 Block diagram 8 Mounting 1.4 ADC DAC IN µc I 1.3 1.2 1.1 GND NC OUT I +24 V DC Figure 1 Block diagram for current output 1.4 ADC DAC IN 1.3 µc U 1.2 1.1 GND OUT U NC +24VDC PACT MCR-RA A Figure 2 Block diagram for voltage output B 7 Structure 1 Figure 4 Mounting 3 4 The current transducers can be snapped onto all 35 mm DIN rails according to EN 60715 using the two PACT MCR-RA DIN rail adapters provided. Alternatively, the current transducers can also be wallmounted using the fixing holes (see Figure 3, "Structure"). Please use appropriate mounting material for this (e.g., M4 x 20 cylinder head screw). 2 3 5 4 Mounting material for wall mounting is not supplied as standard. The requirements for the protection class must be met by means of installation in suitable housing. Figure 3 Structure 1. Input cable feed-through for the primary live conductor 2. Standard output signal and supply voltage (FKCN 2,5/ 4-ST COMBICON connector) 3. Connection option for DIN rail adapter 4. Fixing holes for wall mounting, Ø 4.5 mm 5. Marking option with flat zack marker strips 104059_en_05 PHOENIX CONTACT 6

9 Installation 10 Current monitoring 9.1 Power supply WARNING: Danger Never carry out work when mains voltage is present. Passive control system 4...20mA Power supply via the connection terminal blocks Power is supplied to the current transducers via connection terminal blocks 1.1 and 1.4 (see Section 6 "Block diagram", Figure 1). MCR-SL-CUC-...-I +24VDC 9.2 Connecting the cables Spring-cage connection The supply voltage and standard output signal are connected using the spring-cage connection method. : L1 L2 L3 Figure 6 1.4 1.3 1.2 1.1 Current monitoring A B Figure 5 Spring-cage connection Insert a screwdriver into the opening above the connection terminal block. Insert the wire into the corresponding connection terminal block. 104059_en_05 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 7 www.phoenixcontact.com