Calibration and Testing

Similar documents
Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Series GLET Accessory for dataloggers series GL in modular enclosure

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

Computer Controlled Measurement Amplifiers

Weighing Instruments

User Manual CTP4/8/16

Multipoint measuring units UPM100 and Centipede100

Telemetrie-Messtechnik Schnorrenberg

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

Telemetrie-Messtechnik Schnorrenberg

Transmitter / Signal Conditioning

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

CALYS 75. Field documenting multifunction calibrator

Primary-standard resistance thermometry bridge Model CTR9000

CALYS 50. Field multifunction calibrator for basic use

SC-4/M User manual 4-channel measuring amplifier

Dx: Digital Multi-Channel Telemetry System

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

CSG110 Strain Gauge Universal Amplifier

DMS Insert Module MSR 282

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

C10. Data sheet. Force transducer. Special features. B de

MX1615. Data sheet. Bridge/strain gauge amplifier

Inductive Standard Displacement Transducers

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

GSV-2MSD-DI IP43. Highlights

Product Features Benefits The IMC Group Ltd.

Signal Conditioning Amplifier

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

4830B accelerometer simulator Product overview

Catalog of CLA force and torque sensors

CALYS 150. Advanced documenting multifunction calibrator thermometer

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

CALYS 100. Field precision documenting multifunction calibrator

Variable Gain Photoreceiver Fast Optical Power Meter

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

USB-2404-UI Specifications

Schlöder GmbH - EMC Test and Measurement Systems Model #

CALYS 150. Advanced documenting multifunction calibrator thermometer

PCM - Sensor Telemetry for Turbo Prop/Jet Application

OPTITEMP TT 20 Technical Datasheet

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

Variable Gain Photoreceiver - Fast Optical Power Meter

Variable Gain Photoreceiver Fast Optical Power Meter

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

Components Signal Conditioning For Your Computer Instruments Standard Models

Model 140 Inline Amplifier

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Coupling/Decoupling Networks (CDN)

MTP-NT INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

Tel: (949) Fax: (949) IAA100 Product Manual

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

Coupling/Decoupling Networks (CDN)

Hand-held temperature calibrator Model CEP3000

Additel 875 Series Dry Well Calibrators

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

QUICK SETUP GUIDE SECULIFE ESPRO

Kraus Messtechnik GmbH

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

AXON J1DB. digital 1-channel telemetry for strain gauge measurement with additional monitoring of inductive energy on the rotor unit

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

Analog Signal Conditioning Accessories

MTP-NT. Preliminary version Sophisticated multi-channel telemetry system for rotating application, fully software programmable with 16 bit resolution

Multichannel amplifier Model 9235/36

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

Isolators A3/1.

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Modular Smart Interfaces

200 MHz Variable Gain Photoreceiver

MECE 3320 Measurements & Instrumentation. Data Acquisition

On-site multifunction calibrator

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

PIECAL 820 FIELD CALIBRATION PROCEDURE

The Art of Measuring. Interface Technology Product Overview. ProLine

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

Product Features Benefits The IMC Group Ltd.

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Portable Multi-Channel Recorder Model DAS240-BAT

High-precision process calibrator Model CED7000

Multifunction Calibrator - Model 8080

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Operating manual. 600 Hz Measuring Amplifier ME30. A en

Low Noise Variable Gain Low Frequency Voltage Amplifier

Modular Controller. Key Features. Model Complete system controller for 8 channel applications; EDFA pumping or DWDM signal sources

CALYS channels High accuracy calibrator

INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

MICROTC LINEAR THERMOCOUPLE AMPLIFIER OPERATOR S MANUAL

Transcription:

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Features System Sources Measurement chain Strain gauge bridges Current signals Voltage signals Thermocouples Pt100 resistors Frequency Applications Industrial measurement and control technology Test bench measurement Mobile measurement pi-im-sim_e V1.25-00 1

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Functions and Benefits The devices serve for highly accurate simulation of strain gauge bridges to check strain gauge amplifiers. The Test Simulator offers in addition physically correct simulation of potentiometers, thermocouples, Pt100 resistors, as well as current and voltage sensors, and speed indicators. Device Overview standard alternative Mistakes reserved, technical specifications subject to change without notice. 2 pi-im-sim_e V1.25-00

GHM GROUP - Standort Imtron GHM Messtechnik GmbH Carl-Benz-Straße 11 88696 Owingen GERMANY Phone +49 7551 9290-0 Fax +49 7551 9290-90 Characteristics The GHM SensorSimulator outputs various voltage and current signals. The GHM SensorSimulator can also simulate sensors such as Pt100, thermocouples and strain gage sensors optimally through the additional back-up measurement of the supply voltages and currents of the connected measuring amplifiers. Optionally a frequency output is available. It can be used to calibrate and verify displays, transducers or complete measurement chains. In addition, voltages and currents can be measured with the device. Technical Data Simulation Voltage Signal Current Strain Gage General Accuracy See Simulation and Measure 7-pol. Binder socket for Signal In- and Output Connection Micro-USB for Supply voltage and charging Graphic-LCD, monochrome, (180 x 128 Display Pixel) adjustable backlighting Operation Keypad Languages German, English Dimensions 160 x 86 x 37 mm (H x W x D) Weight 250g (incl. Accu) Supply voltage 5 V DC (Micro-USB) Accu Lithium-Ion Ambient temperature 0..+50 C Thermocouple, Type K (Others opt.) Thermocouple, Type J ( Others opt.) Thermocouple, Type N ( Others opt.) Thermocouple, Type S ( Others opt.) Pt100 Frequency (Option F) Measuring Voltage Current ± 10 V ± 25 ma 0, 0.5, 1, 2, 4, 5, 10, 25, 50 mv/v Supply 2,5 V, 5 V, 10 V -100..+1000 C (-100.. 100 C: 10 C steps 500.. 1000 C: 50 C steps) simulated compensation: ± Accuracy 1%; internal temperature measurement: ± 3 K -100..+1000 C (-100.. 100 C: 10 C steps 500.. 1000 C: 50 C steps) simulated compensation: ± Accuracy 1%; internal temperature measurement: ± 3 K -100..+1250 C (-100.. 100 C: 10 C steps 500.. 1250 C: 50 C steps) simulated compensation: ± Accuracy 1%; internal temperature measurement: ± 3 K -50..+1600 C (-50.. 100 C: 10 C steps 500.. 1600 C: 50 C steps) simulated compensation: ± Accuracy 1%; internal temperature measurement: ± 3 K -100..+850 C (-100.. 100 C: 10 C steps 500.. 850 C: 50 C steps) 1 Hz.. 500 khz (Steps: 1.. 10 Hz: 1 Hz 10.. 100 Hz: 10 Hz 100 Hz.. 1 khz: 100 Hz 1.. 10 khz: 1 khz 10.. 100 khz 10 khz 100.. 500 khz: 100 khz) Level (adjustable) ± 10 V ± 1 % Accuracy ± 0,5 % Measuring Range ± 30 ma Accuracy ± 0,5 % pi-im-sim_e V1.25-00 3

GHM GROUP - Standort Imtron GHM Messtechnik GmbH Carl-Benz-Straße 11 88696 Owingen GERMANY Phone +49 7551 9290-0 Fax +49 7551 9290-90 Block Diagram Delivery Content GHM SensorSimulator with protective silicon cover Accu, Charger Connection cable User Manual Ordering Code SIM-SenSim-1 1. 1. Option Order number No Option 201164 F Frequency output 201366 Accessoires Name Description Order number SIM-SenSim-KAB SIM-SenSim-KAB- BNC SIM-SenSim-BAN- BOX SIM-SenSim-Case SIM-SenSim-ST- BB7 Adapter cable for SIM-SenSim-1 7-pol. Binder on 7-pol. Wagoclamp (Supplied with the unit) Adapter cable for SIM-SenSim-1-7-pol. Binder on BNC connector Suitable for simulation of voltage, current, frequency and measurement of voltage, current BreakOutBox with 7 banana jacks for connection to SIM-SenSim- KAB adapter cable Case for GHM-SenSim-1 and accessories (340 x 275 x 83 mm) 7 pin Binder connector Suitable for SIM-SenSim for the self-assembly of connecting cables 201367 201377 201368 201378 200448 4 pi-im-sim_e V1.25-00

GHM GROUP - Standort Imtron GHM Messtechnik GmbH Carl-Benz-Straße 11 88696 Owingen GERMANY Phone +49 7551 9290-0 Fax +49 7551 9290-90 DMS Manual Calibrator Ordering Code 1. 2. 3. 4. SIM-DMS - XXX/YYY R - - - Characteristics Picture with 2 bridge resistances The manual strain gauge calibrator is used for simulation of strain gauge sensors with bridge resistances of 120 W, 350 W or 1000 W. Other bridge resistances or the combination of up to 2 bridges in one housing are available on request. The device is used wherever strain gauge amplifiers need to be tested or calibrated. The sensitivity setting is done by parallel connection of resistances to a shunt arm. For switching of polarity the shunt circuit is reversed. Sensitivity settings and switching of polarity are done manually with high-precision switches. 1. Hand-operated simulator 120 Bridge resistance 120 Ω 350 Bridge resistance 350 Ω 1000 Bridge resistance 1000 Ω 120 / Housing with 2 bridge resistances 350 120 / 350 Ω 120 / Housing with 2 bridge resistances 1000 120 / 1000 Ω 350 / Housing with 2 bridge resistances 1000 350 / 1000 Ω 2. Option FK1 Frequency inspection up to 5 khz for 1 bridge resistance FK2 Frequency inspection up to 5 khz for 2 bridge resistances 3. Terminal - 7-pole Lemo socket (standard) BAN optional plus 7 banana sockets (only for 1 bridge resistance) 4. Accessories LS7 Plug for 7-pole Lemo socket, price per plug Example: SIM-DMS-120/350R-LS7 Technical Data Sensitivity settings Bridge resistances Terminal(s) Accuracy DC 0; 0.25; 0.5; 1; 2; 4; 5; 8; 10; 25; 50 mv/v 120, 350, 1000 Ω 7-pole Lemo jack series 2B (others on request) optional 7 Banana jacks ± 0,02 % (for setting 2 mv/v) for carrier frequency 5 khz ± 0.5 % Stability ± 0,02 % (for setting 2 mv/v) Environmental temperature 0..50 C Dimensions 118 x 64 x 170mm (B x H x T) pi-im-sim_e V1.25-00 5

GHM GROUP - Standort Imtron GHM Messtechnik GmbH Carl-Benz-Straße 11 88696 Owingen GERMANY Phone +49 7551 9290-0 Fax +49 7551 9290-90 DMS IEEE 488 Calibrator Ordering Code 1. 2. 3. SIM-DMS-IEEE - XXX/YYY R - - Characteristics The IEEE 488 strain gauge calibrator is used for simulation of strain gauge sensors with bridge resistances of 120 W, 350 W or 1000 W. Other bridge resistances or the combination of up to 2 bridges in one housing are available on request. The device is used wherever strain gauge amplifiers need to be tested or calibrated. The sensitivity setting is done by parallel connection of resistances to a shunt arm. For switching of polarity the shunt circuit is reversed. The feed-forward control by a computer is done via the IEEE 488 interface. For that the address can be configured with a DIP switch on the back side. Functions like ZERO, sensitivity, and switching of polarity can be also manually set with keys. LED strips display the sensitivity in mv/v, other LEDs display polarity setting and selected bridge resistance. Technical Data Sensitivity settings Bridge resistances Terminal(s) Accuracy DC 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1; 1.5; 2; 3; 4;5; 10; 20; 30; 40; 50; 100; 250 mv/v 120, 350, 1000 Ω 7-pole Lemo jack series 2B, optional 7 Banana jacks ± 0,02 % (for setting 2 mv/v) 1. IEEE simulator 120 Bridge resistance 120 Ω 350 Bridge resistance 350 Ω 1000 Bridge resistance 1000 Ω 120 / Housing with 2 bridge resistances 350 120 / 350 Ω 120 / Housing with 2 bridge resistances 1000 120 / 1000 Ω 350 / Housing with 2 bridge resistances 1000 350 / 1000 Ω 2. Option FK1 Frequency inspection up to 5 khz for 1 bridge resistance FK2 Frequency inspection up to 5 khz for 2 bridge resistances 3. Terminal Accessories - 7-pole Lemo socket, 7 banana sockets (Standard) LS7 Plug for 7-pole Lemo socket, price per plug Example: SIM-DMS-IEEE-350-R for carrier frequency 5 khz ± 0.5 % Stability ± 0,02 % (for setting 2 mv/v) Environmental temperature 0..50 C Block Diagram Dimensions 480 x 40 (80) x 290 mm (B x H x T) 6 pi-im-sim_e V1.25-00

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 pi-im-sim_e V1.25-00 7

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Product Overview Laboratory Instrumentation Industrial Sensors and Instrumentation Industrial Electronics Displays / Controller Transmitter / Signal conditioning Isolating converters Safety and Monitoring Devices Power Electronics Process Instrumentation Hygienic Design GHMadapt Temperature Flow Level / Filling Height Analysis Measuring Data Acquisition Data Logging and Monitoring Test Bench Measurement Technology Renewable Energies 8 pi-im-sim_e V1.25-00