Inside Biograph mct.

Similar documents
Iterative Reconstruction in Image Space. Answers for life.

Software and Hardware in CCTA. Elly Castellano PhD

SAFIRE. Sinogram Affirmed Iterative Reconstruction. Answers for life.

2D, 3D CT Intervention, and CT Fluoroscopy

Research Support. Dual-Source CT: What is it and How Do I Test it? Cynthia H. McCollough, Ph.D.

160-slice CT SCANNER / New Standard for the Future

Data. microcat +SPECT

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Multi-Access Biplane Lab

PET/CT Instrumentation Basics

PET: New Technologies & Applications, Including Oncology

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

Ysio Max. The most direct way to the image. Answers for life.

LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option

Maximum Performance, Minimum Space

NeuViz 16 Computed Tomography. Elevating routine imaging for exceptional results

Inveon. No Limits on Discovery.

Chiara Secco. PET Performance measurements of the new LSO-Based Whole Body PET/CT. Scanner biograph 16 HI-REZ using the NEMA NU Standard.

Brilliance in everything Philips CT products and services

Industry Breakthrough

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

Liver imaging beyond expectations with Ingenia

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

Detector technology in simultaneous spectral imaging

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

2010 Philips BrightView XCT SPECT/CT

Industry Breakthrough

Clinical Experience Using the Open Bore Multislice CT System Supria (16 slice CT) MEDIX VOL. 61 P.8 P.11

Luminos RF Classic. Where value meets performance.

The future of nuclear imaging is clear

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

Truly flexible to meet your clinical needs

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

Luminos drf Max. Taking 2-in-1 to the MAX in radiography and fluoroscopy. siemens.com/luminos-drf-max

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

GE Healthcare. Senographe 2000D Full-field digital mammography system

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

The shortest distance to diagnosis Philips BrightView SPECT

Maximizing clinical outcomes

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

COMPUTED TOMOGRAPHY 1

CHAPTER 8 GENERIC PERFORMANCE MEASURES

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

2/14/2019. Nuclear Medicine Artifacts. Symmetric energy windows

Philips Astonish. Key advantages. including improved image quality and

CT Basics: Image Quality Module 6

Celesteion Time-of-Flight Technology

3T Unlimited. ipat on MAGNETOM Allegra The Importance of ipat at 3T. medical

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Photomultiplier Tube

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

Reach out for the power in mobile x-ray imaging MULTIMOBIL 10. Answers for life.

New Technology in Nuclear Medicine

Changing the Shape of Nuclear Medicine

Philips EasyDiagnost Eleva

SPECT Reconstruction & Filtering

R&F X-ray systsem. Savings With Every Exposure

diagnostic examination

Fundamentals of Positron Emission Tomography (PET)

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life.

Noise Characteristics of the FORE+OSEM(DB) Reconstruction Method for the MiCES PET Scanner

FMT18 FLOOR MOUNTED SYSTEM

SOMATOM Esprit A Bundle of Energy

Computed Tomography. The Fundamentals of... THE FUNDAMENTALS OF... Jason H. Launders, MSc. Current Technology

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Initial Certification

Lunar Technology Advantages

Wide-Detector CT for TAVR Planning:

TimTX TrueShape. The parallel transmit architecture of the future. Answers for life.

PET Performance Evaluation of MADPET4: A Small Animal PET Insert for a 7-T MRI Scanner

ddr Compact Series Setting a new benchmark in digital radiography.

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

efficiency ddrcompact Series

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Data. Take the Lead in CT SOMATOM Sensation 64

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

CT Basics: Data Acquisition Module 3

GE Healthcare. Performa. High-performance breast imaging

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

GE Healthcare. Essential for life. Senographe Essential Full-Field Digital Mammography system

Get more from your images with Symphony Image Processing

make it easy, with Ray

Revolutionizing 2D measurement. Maximizing longevity. Challenging expectations. R2100 Multi-Ray LED Scanner

v tome x m microfocus CT

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

QC by the MPE in Belgium

QC Testing for Computed Tomography (CT) Scanner

LaBr 3 :Ce, the latest crystal for nuclear medicine

productivity ddrformula Series

Think Digital. ddr Modulaire A quantum leap in radiography workflow and efficiency.

Explain what is meant by a photon and state one of its main properties [2]

Redefining Ergonomics

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Simulation and evaluation of a cost-effective high-performance brain PET scanner.

Transcription:

Inside Biograph mct The technologies behind the world s first molecular CT. www.siemens.com/mi

Large 78 cm bore helps reduce claustrophobia and provides more room for RTP positioning devices. 227 kg (500 lb.) bed limit with wide pallet helps accommodate bariatric patients. STRATON X-ray tube provides fast 0.3s CT rotation speed and high resolution. Adaptive Dose shield lowers CT dose by up to 20%. Adaptive 4D spiral allows whole-organ perfusion studies.

many-technologies-in-one-device CT. Welcome to the inner world of Biograph mct. Beyond the incredibly small dual-modality footprint, large 78 cm bore, and all the ergonomics is a universe of sophisticated technologies. Working precisely and in tandem, these technologies bring you magnificent images from the human body in both CT and PET to give you diagnostic capabilities like never before. LSO crystals and HI-REZ detectors offer industryleading PET performance. TrueV extends the PET field of view (FOV) by 33% and increases NEMA count rate by 70%. HD PET offers uniformity, high-resolution, and 2x better contrast over conventional PET. ultrahd PET provides uniformity, high-resolution, and 4x better contrast compared to conventional PET. Tubeguard monitors the condition of the STRATON tube and reduces unscheduled downtime.

CT TECHNOLOGY STRATON X-ray tube Our unparalleled 0 MHU STRATON X-ray tube has caused a paradigm shift in CT imaging. The tube s direct anode cooling eliminates the need for heat storage, permitting a compact design and fastest CT gantry rotation for all applications. Conventional tube technology In cardiac imaging, where the ability to freeze motion is critical, Biograph mct provides you with super-fast rotation time, making non-invasive cardiac diagnosis routinely available. To increase temporal resolution, the proprietary STRATON X-ray tube enables the market s fastest gantry rotation time of 0.30 s, resulting in 150 ms temporal resolution for motion- and artifact-free imaging of the heart. STRATON X-ray tube 1 1 2 z-sharp technology Instead of decreasing the size of detector elements to improve spatial resolution, z-sharp Technology utilizes two overlapping X-ray beams, resulting in significantly increased resolution without a corresponding increase in dose. This provides you with the industry-leading isotropic resolution of 0.33 mm at any scan and rotation speed, and at any position within the scan field. In addition, with our proprietary z-uhr Technology, the system adapts for ultra-high resolution bone imaging for wrist, joint, or inner ear studies. We push the boundaries of spatial resolution even further providing unparalleled 0.24 mm isotropic resolution until now seen only with research flat panel and Micro CT technology. Over Sampling 0.6 mm Oversampling 0.6 mm 2

CT TECHNOLOGY CARE Dose4D: real-time dose modulation The CARE Dose4D feature utilizes an advanced computing technique that provides real-time dose modulation of the X-ray tube current according to the precise shape of the patient s body during both spiral and sequential scanning. It reduces the patient dose for low attenuation views, while the dose is kept at a nominally higher ma for high attenuation angles. From the initial topogram, a base ma setting is determined. During the scan, a detector element measures the attenuation through the patient and transfers that information to the output generator of the X-ray tube to keep the ma at a level which provides the accepted image quality. CARE Dose4D provides these economical and clinical benefits: Up to 66% dose reduction while maintaining the same image quality as compared to clinical protocols not employing CARE Dose4D Enhancement of the image quality and reduction of artifacts for scanning of asymmetric body regions, such as the shoulders or scans of the patient with arms alongside the body Lower power consumption and reduced heat load Longer spiral ranges and more flexibility for multiphase examinations, especially for obese patients Low dose examinations for pediatric patients Adaptive Dose Shield The Adaptive Dose Shield, which is unique to the CT industry, is part of the innovative new STRATON X-ray tube design. It moves collimators on the X-ray tube to block unnecessary radiation dose. The Adaptive Dose Shield dynamically opens at the beginning of a spiral range and then dynamically closes at the end. Now all clinically irrelevant dose is eliminated. Not only for dedicated applications, but for every single spiral acquisition. Giving you the ability to save an additional 20%* of dose in routine exams like abdominal CT. Conventional tube collimation *Results may vary. Data on file. Post-Spiral Dose Pre-Spiral Dose Image Area Conventional Technology Image Area STRATON with Adaptive Dose Shield No Pre-Spiral Dose No Post-Spiral Dose Image Area Unnecessary radiation Adaptive Dose Shield 3

CT TECHNOLOGY Adaptive ECG-Pulsing and Adaptive Cardio Sequence Adaptive ECG-Pulsing, our innovative heartbeatcontrolled dose modulation, applies the exact dose necessary to collect data projections of 180 degrees during the diastolic phase. Its real-time monitoring of the ECG enables a fully automated dose adjustment, instantly reacting to changes and abnormalities of the heartbeat. Instead of using multisegment reconstruction at higher heart rates, Biograph mct with its high temporal resolution, allows you to acquire cardiac images from a single heartbeat. The MinDose feature reduces the pulsing window to a minimum of 4%, giving you additional dose savings. Adaptive ECG-Pulsing in Spiral Mode 4% Minimum Dose Adaptive Cardio Sequence in Sequential Mode react scan move scan move scan react scan In addition to the Adaptive ECG-Pulsing, Biograph mct offers sequential cardiac acquisition mode. We call it Adaptive Cardio Sequence. It s an intelligently triggered sequence that shuts off radiation in the systolic phase and dynamically reacts to irregularities during the ECG trace. The real-time ECG monitoring reacts instantly to irregularities and stops the scan until the heart rate becomes stable again. This arrhythmia compensation method allows for high dose savings and an increased robustness of the scan. Ultra-fast ceramic CT detector Our proprietary Ultra-fast Ceramic (UFC) CT detector uses superior X-ray absorption, high light output and very short afterglow properties to produce stunning CT image quality. Compared to other detector materials, UFC has a much faster decay reaction, which enables the detector to measure more incoming photons per unit of time and contributes to improved image quality. This property, in combination with the short afterglow of UFC, allows very fast CT rotation times without an increase in image noise. 4

CT TECHNOLOGY SureView: uncompromising image quality A patented solution for multislice CT scanning, SureView provides exceptional image quality at any pitch setting. To acquire a scan, you simply select the scan volume (range), mas, scan time, and slice width. All other parameters, such as pitch, are automatically calculated by the scanner, ensuring high quality imaging at any scanning speed. For spiral scanning, SureView yields a remarkably low image noise level. To produce the same noise level as sequential CT images, our spiral scan protocols are created with lower mas and therefore, can reduce doses by up to 20%. You specify the slice thickness according to your clinical needs, and SureView automatically provides the best image quality with reliable, excellent performance. SureView allows more patient coverage without loss of resolution. 49 mm/sec Siemens 40-slice CT with SureView 40 x 0.6 mm, 0.37 sec pitch 1.5 for z-resolution of 0.4 mm 55 mm/sec Competitive 64-slice without SureView 64 x 0.625 mm, 0.4 sec limited to pitch 0.55 for z-resolution of 0.4 mm 87 mm/sec Siemens 64-slice CT with SureView 64 x 0.6 mm, 0.33 sec pitch 1.5 for z-resolution of 0.4 mm Adaptive 4D Spiral With today s conventional CT and its restricted coverage, whole organ perfusion studies i.e., long-range phase resolved CTA studies, are just not possible. The industry s initial attempts to overcome these limitations focused on extending the coverage, but were limited to twice the detector size. The result was an inability to cover the entire organ. Through our innovative Adaptive 4D Spiral, we apply a continuously repeated bi-directional table movement, moving the patient smoothly in and out of the gantry over the desired scan range. It s how we re able to overcome the coverage limitation of a static detector design. The Adaptive 4D Spiral enables you to adapt the coverage to exactly the range you need. For example, you can perform a phase resolved CTA study over a length of 270 mm, providing a clear separation of arterial and venous phase. Now for the first time in perfusion studies, you can cover virtually any organ in 4D, such as performing a complete stroke assessment of the entire brain. Conventional Perfusion Bi-Directional Table Adaptive 4D Spiral Gantry 5

PET TECHNOLOGY most-advanced-pet Biograph mct with HD PET and ultrahd PET gives you the ultimate in PET capabilities, offering uniform resolution throughout the field of view and up to 4x better contrast over conventional PET scanners. Resolution Uniformity Contrast Throughput Conventional PET imaging: Conventional PET imaging requires users to make compromises. An improvement in one key area comes at the cost of performance in other key areas, resulting in sub-optimal performance overall. Resolution Uniformity Contrast Throughput Biograph mct imaging: Biograph mct gives you optimum performance in all key areas, so you don t have to make compromises in daily operation. This results in unmatched clinical capabilities, providing high resolution, high contrast, uniformity, and high throughput. Standard High Definition LSO Crystals Pico-3D Electronics HI-REZ Detectors TrueC Scatter correction HD PET ultrahd PET Built on proven and patented PET technologies, Biograph mct offers true high-definition PET imaging. HI-REZ-FBP Without HD PET With HD PET and ultrahd PET HD PET and ultrahd PET Signal to Noise at 30cm 2x improvement in signal to noise 4x improvement in signal to noise PET HD PET ultrahd PET HD Uniformity: Images are distortion-free throughout the entire field of view, from center to edges, enabling more accurate visualization of fine detail no matter where you look. HD Resolution: HD PET and ultrahd PET offer 2 mm uniform resolution across the entire field of view for enhanced detectability and the highest level of detail. HD Contrast: With an unprecedented 2x and 4x improvement in signal-to-noise ratio, HD PET and ultrahd PET reveal sharper images, as well as greater distinctness within the image. 1 Measurements were taken with a line source suspended in air at radial positions from the center to 28 centimeters in 4 centimeter steps. The Biograph HI-REZ-FBP data were reconstructed with a standard filtered backprojection algorithm after FORE rebinning and the HD PET data were reconstructed with the TrueX algorithm using six iterations and 14 subsets. 6

Conventional PET ultrahd PET Conventional (top row) vs. HD PET (bottom row) With the industry-leading NEMA count rate, Biograph mct enables outstanding PET perfusion studies, as in this inferolateral myocardial infarction with total occlusion at mid RCA. Biograph mct offers excellent resolution and contrast in PET CT imaging, such as in this primary squamous cell carcinoma in the left lung with hilar lymph node metastases. 7

PET TECHNOLOGY HD PET When a photon strikes a crystal, it travels a certain distance before its energy is converted into light. The further away from the center of the FOV, the less likely the line of response (LOR) will be calculated correctly because the photon will hit the crystal on an angle and continue traveling to another crystal before it lights up. A point spread function (PSF) describes the response of an imaging system to a point source or point object. A system that knows the response of a point source from everywhere in its FOV can use this information to recover the original shape and form of imaged objects. Conventional PET uses the same reconstruction principles across the entire FOV and does not take into account the detector geometry and mispositioning of the LORs. This results in fuzzy edges and increased distortion further from the center of the FOV. Conventional PET HD PET incorporates millions of accurately measured point spread functions in the reconstruction algorithms. Using measured PSFs, HD PET effectively positions the LORs in their actual geometric location, which dramatically reduces blurring and distortion in the final image. HD PET Data courtesy of the University of Tennesee. Benefits: HD uniformity HD resolution HD contrast 2x 8

PET TECHNOLOGY ultrahd PET ultrahd PET = HD PET + Siemens TOF Conventional PET Conventional PET detects coincidence photons and records individual LORs between the crystals. The actual location where the annihilation occurred along the LOR is not measured, which inherently generates blurring in the reconstructed image. ultrahd PET Siemens ultrahd PET with Time of Flight (TOF) measures the actual time difference between the detection of each coincidence photon. This additional timing information is used to better localize the event within a small range along each LOR. The better localization of each event using TOF reduces blurring in the reconstructed image. In this simplified example, four lines of response projections are summed together. The resulting image is a rough approximation of the real image with noticeable blurring. Conventional PET + + + With ultrahd PET technology, the TOF projections are organized in time bins along each line of response. This results in a better estimate of the actual image with much less blurring. ultrahd PET + + + Data courtesy of the University of Tennesee. Benefits: HD uniformity HD resolution HD contrast 4x 9

PET TECHNOLOGY TrueV: extended field of view TrueV widens the axial field of view (FOV) by 33%, which increases count rate performance by more than 70%, giving you the clinical flexibility to lower dose rates or scan times by 50%. To make the most of the additional FOV, the acceptance angle in the 3D PET acquisition is increased. In this way, more lines of response can be measured per a given unit of time. By increasing the lines of response and thereby, the count rate, scanning protocols can be more flexible. With TrueV you can improve image quality while shortening scan time or reducing the injected dose. Shortened scan time results in less patient motion, fewer motion artifacts, and more time for dedicated CT scans. TrueV widens the axial field of view by 33%. With TrueV Without TrueV Conventional Field of View Biograph with TrueV TrueV extended PET field of view from Siemens has raised all of our expectations as to what PET CT should be and what it can do to help our patients. Dr. David Townsend, University of Tennessee 33% wider field of view increases effective count rate by over 70% and reduces bed positions per scan by an average of 30%. TrueC: highly efficient scatter correction Scatter correction is a vital component of PET image quality, particularly in cardiology where scattered photons are often the result of the activity of structures near the heart, such as the liver and intestines. Without scatter correction, image degradation can result, making analysis difficult, if not impossible. To improve image analysis and thus, the assessment of patients, Biograph mct includes TrueC, a highly efficient, model-based Compton scatter correction system using Monte Carlo-based computational techniques. This single scatter simulation algorithm employs a unique, intuitive sampling technique organized as a summation over sample scattering points. TrueC is particularly efficient because it reuses the computed ray sums through the object to compute scatter contributions to multiple lines of response. Our single scatter based computational approach has been proven to offer the best balance of speed and accuracy for individual, patient-tailored scatter correction. 10

PET TECHNOLOGY LSO: state-of-the-art crystal technology With more than 10 years of experience in Lutetium Oxyorthosilicate (LSO) scintillator crystal technology, Siemens is a pioneer in innovative PET imaging techniques. The Biograph TruePoint PET CT employs patented LSO PET detectors that provide clear and fast images. A PET scanner s performance greatly depends on the scintillation properties of the detector crystal material. With a fast scintillation decay time of 40 ns and the highest density available, LSO crystals offer the best combination of properties of any PET scintillator known today. LSO offers a fast coincidence timing window of 4.5 ns for efficient rejection of random events and enough light output for high energy resolution discrimination to facilitate the efficient rejection of randoms all to provide high count rate statistics, which are essential to high speed PET scanning. HI-REZ: more than 250% improved volumetric resolution LSO is capable of tremendous light output, which enables very small individual detector crystals to be produced. The extremely small HI-REZ crystals result in exceptional isometric spatial resolution an improvement of 250% without any loss of sensitivity. Conventional PET HI-REZ PET Conventional PET detector block and annihilation LSO HI-REZ detector block and annihilation 11

PET TECHNOLOGY Siemens Remote Service Siemens Remote Service (SRS), a proactive remote-monitoring infrastructure for medical equipment, makes maintenance and repairs easy for your Biograph mct. With SRS, we can detect and fix most problems remotely and expedite on-site repair if new parts are required. But that s not all. SRS proactively monitors your system to detect and repair parameter deviations that could lead to future problems, making your Biograph mct extremely robust and reliable. And you can trust SRS to keep sensitive medical data secure. SRS employs sophisticated authentication and authorization procedures that are compliant with security and privacy standards recommended by US, European, and Japanese manufacturers. SRS advantages Fast and easy error detection Fast repair times Reduction in unscheduled downtime Improved patient planning and throughput Planned spare parts replacement Reduced on-site involvement with remote diagnosis Maximized system utilization and performance Tubeguard Biograph mct comes with the dependability of Tubeguard, a unique remote service that provides real-time condition reports of the scanner s STRATON tube. Tubeguard employs more than 10 proactive sensors to monitor the performance of the tube and assess its longevity. Based on real-time data from sensors and other complex algorithms, Tubeguard estimates how long the tube will last and when it is due for replacement. This helps schedule service and maintenance appointments and virtually eliminates the possibility of a sudden tube failure. 12

Trademarks and service marks used in this material are property of Siemens Medical Solutions USA or Siemens AG. All other company, brand, product and service names may be trademarks or registered trademarks of their respective holders. Siemens reserves the right to modify the design and specifications contained herein without prior notice. As is generally true for technical specifications, the data contained herein varies within defined tolerances. Some configurations are optional. Product performance depends on the choice of system configuration. Please contact your local Siemens Sales Representative for the most current information or contact one of the addresses listed below. Note: Original images always lose a certain amount of detail when reproduced. All photographs 2008 Siemens Medical Solutions USA, Inc. All rights reserved. Global Business Unit Address Siemens Medical Solutions USA, Inc. Molecular Imaging 2501 N. Barrington Road Hoffman Estates, IL 60192-5203 USA Telephone: +1847 304 7700 www.siemens.com/mi Global Siemens Headquarters Siemens AG Wittelsbacherplatz 2 80333 Munich Germany Global Siemens Headquarters Healthcare Headquarters Siemens AG Healthcare Sector Henkestrasse 127 91052 Erlangen Germany Telephone: +49 9131 84-0 www.siemens.com/healthcare Legal Manufacturer Siemens Medical Solutions USA, Inc. Molecular Imaging 810 Innovation Drive Knoxville, TN 37932-2751 USA Telephone: +1 865 218 2000 www.siemens.com/mi www.siemens.com/mi Order No. A91MI-10166-1C-7600 Printed in USA PA 0908/7 09.2008, Siemens AG