Laser LAX 300. Operating instructions

Similar documents
Laser LAX 300 G. Operating instructions

Laser LA-4P. Operating instructions

STABILA compact lasers: For all finishing trades.

STABILA compact laser: For all professionals. For all finishing trades.

Multi-beam Self-leveling Line Laser

LAX 400 multi-line laser

A510S Operation Manual

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

Laser Distance Finder Extech DT500

Operator's Manual. 10-in. Digital Multi-function LEVEL with Laser Trac. Model No

Laser Distance Finder Extech DT500

FLS 90 floor line laser

IMPORTANT: Read Before Using. Operating/Safety Instructions 8601-RL

Operating Instructions GEMINI R

Pipe Laser Model No Instruction Manual

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

CONTENTS. User Safety 2 Introduction and CXR880 Accessories 3 CXR880 Diagram 4 CXR880 Keypad and Remote Control 5 Operating Instructions 6

62120LLCP PRECISION LASER SIGHT AND LIGHT INSTRUCTION MANUAL

INSTRUCTION MANUAL DW089-XE 3 BEAM LINE LASER

PACIFIC LASER SYSTEMS. HVL100 Procedures

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER

BORE ALIGNMENT. Straightness measurement of bore and bearing journals PRINTER CONNECTION PC PROGRAM INCLUDED ELECTRONIC INCLINOMETER EXPANDABLE

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

Digital Target Locator. The smart way to measure.

Mount to the Wall INSTALLATION MANUAL

Battery Installation Controls and Displays Safety Initial Setup Guidelines Level Setup Slope setup...

Visit us at

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

TechNote #34 ROTALIGN

Geo EasyTrack Auto Tracking System for Line Lasers

STABILA laser distance measurer: The right product for every use.

MY-HITE CORNER ADJUSTABLE TABLE

MY-HITE ADJUSTABLE TABLE

Laser LAX 200. Operating instructions

Laser distance measurers for real professionals: accurate, quick and reliable results for all applications

Laser User Manual. Therapy Unit INTRODUCTION

Lasers/ Optical Equipment

METAL DETECTOR INSTRUCTION GUIDE

114-GB(cover,p1-12) 25/08/ :49 AM Page

Assembly Instructions for model: VMPR1

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

//LASER AND DETECTOR TECHNOLOGY

Operating Manual MRL-101

Color Video Projector

Professional cross-line laser

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

3B SCIENTIFIC PHYSICS

L-742 Ultra-Precision Roll Alignment System for Printing Presses/Paper Machines

WS-9006U Wireless Temperature Station

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

3B SCIENTIFIC PHYSICS

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

303SPH SPHERICAL VR HEAD

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Wireless Pressure Station with Backlight

INSTALLATION INSTRUCTIONS

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

Wireless Pressure Station

USER MANUAL LASER SIGHT. Triple Duty CRL (Compact Rail Laser) English

2. Refraction and Reflection

R9962 ROBERTS. LW/MW/SW1-9/FM 12 band Portable World Radio. Sound for Generations

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

1. Brief Introduction

B-Tronic EasyControl EC5401B

southpaw enterprises, inc.

imove-f Assembly Manual (Motorized Version-M1/M2)

Model R8001. Instructionn Manual. Laser Distance Meter. reedinstruments. www. com

R984 LW/MW/FM STEREO 3-BAND RADIO ROBERTS. Sound for Generations. Operating Instructions

Apple Wireless Keyboard (A1255) Teardown. Written By: mayer. ifixit CC BY-NC-SA Page 1 of 11

Univox Loop Listener. Loop receiver and testing device. User Guide. Univox Loop Listener Part No /230453

This is a motor attachment option in which the motors attach closely to the sides of the NXT.

GO! with Microsoft PowerPoint 2016 Comprehensive

1 Symbols. 4 Foreseeable misuse Do not use the device as a laser pointer. Do not use the device in explosive or aggressive environments.

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS


Ricoh XR Speedlite 300P

Feed Drawer Rebuild, for Models, 22HF, 16HF, 1600 machines

Injection Molding. System Recommendations

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 ISO ISO 9001 Registered Quality Management. Registered Environmental Management

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

Beaming Optical Length Tester (BOLT)

USER GUIDE. IR Thermal Scanner. Model IRT500

Laserglow Product Datasheet

PD-I. English Français Español Português

Lab 12 Microwave Optics.

Video Wall Installation Instructions 2W X 3H, 3W X 3H

LA-1010 User s Manual 3 in 1 Stud/Metal/AC Voltage Finder With Laser Line Level.

USER S MANUAL AGES: 8+ R O B O R A P T O R. A F u s i o n o f T e c h n o l o g y a n d P e r s o n a l i t y

DP-19 DUAL PURPOSE DETECTOR INSTRUCTION MANUAL

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

6 Foot/ 1800mm Aisle Width Net-Contain Aisle Containment for N-Type and S-Type Cabinets

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

PHOTOCELLULE HL 2-33 MANUEL D UTILISATION

X2 LASER DISTANCE METER. Operating instruction

BATTERY GRIP INSTRUCTION MANUAL

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

US RACK, Inc Falcon Drive, Madera, CA

Polarization Experiments Using Jones Calculus

Transcription:

Laser LAX 300 en Operating instructions

A1 4 3 2a 1a 2b 8 4 5 9 1b 6 7

X1 X2 X3 5m 5m S = 5m X X S = 5m Y X Y3 Y1 Y2 X Y

en Operating instructions The STABILA LAX 300 is an easy to use crossed line and plumb line laser. It is self-levelling in the range ± 4.5 and enables levels to be determined quickly and accurately. The vertically and horizontally projected laser lines provide exact alignment / working. The pulsed laser-line enables working over larger distances using a special laser-line-receiver ( see line receiver manual). Read the User Manual along with the illustrated portion. Follow the general instructions on the handling, care and maintenance of the instrument. Observe the safety instructions on laser beams. We have endeavoured to explain the unit s handling and functioning in as clear and comprehensible manner as possible. If, however, you still have any unanswered questions, we should be pleased to provide advice over the telephone at any time on the following telephone number : 0049 / 63 46 / 3 09-0 Main components (1a) On/off button (1b) ON / OFF switch (for protecting during transport) (2) LEDs for displaying (2a) Operating mode ON or READY (2b) Battery voltag (3) Exit aperture for the horizontal and vertical laser lines (4) Plumb line laser outlet (5) Foot - extendable (6) Release lever (7) Battery compartment cover (8) Protective cover (9) 1/4 threaded connector for tripod (10) Magnets (11) Wall bracket Before initial start-up : The warning notice in your language must be clearly affixed on the laser instrument at the position indicated. The appropriate stickers are enclosed. A1 A2 A3 A1 LA SE R RA DI ATIO N DO NO T ST AR E IN TO BE AM LA SE R CL AS S 2 This sticker with the warning notice written in the usual language must be affixed here in place of the English text! Batteries must be inserted -> changing batteries

en B1 B2 Main applications: Operating modes The LAX 300 can be used in 2 operating modes: 1. as a self-levelling line laser 2. as a laser instrument for marking + plumb line laser applications without the levelling function Operating mode with self-levelling A laser line can be selected in this mode. C1 C2 C3 C4 A4 A4 D1 D2 D3 E1 E2 E3 Commissioning The instrument is switched on with the on/off switch (1b). Horizontal and vertical laser lines and the plumb line points appear after switching on. The laser will automatically level itself. Setting the type of line: The vertical and horizontal laser lines with the plumb line point and the cross laser line can be set after each other by pressing the selector switch (1a). The laser will flash if the inclination is too great! laser beam flashing-> The unit is inclined too much + is outside the self-levelling range + the laser cannot level itself automatically Operating mode without levelling function: The on/off switch (1b) is switched off. In this mode the LAX 300 is only switched on or off with the selector switch (1a). Plumb line function mode The foot can be extended in order to improve the visibility of the lower plumb line point. The LAX 300 is positioned and switched on ( switch 1b ). The laser down beam is aligned as required to the object or a mark. Mark the position of the up laser beam on the ceiling. The laser lines are always switched on at the same time as the plumb line laser points. Always ensure that the centre of the laser line is marked! Checking the calibration LAX 300 crossed line and plumb line laser is designed for use on the construction sites and left our factory perfectly adjusted. As with any precision instrument, however, its calibration must be regularly checked. The unit should be checked before starting any new tasks, particularly when the unit has been exposed to strong vibrations.

en Horizontal checking 1. Horizontal checking - Line level Two parallel wall surfaces at least 5m /16 5 apart are required for the horizontal check. 1. Place the LAX 300 on a smooth surface or on a tripod at a distance of 50 mm to 75 mm in front of wall A and with the front side pointing towards the wall 2. Switch the unit on (1b). 3. Mark the position of the visible laser line cross on the wall A (point 1). 4. Turn the complete unit 180 without altering the height of the laser. 5. Mark the position of the visible laser line cross on the wall B (point 2). 6. Now move the unit directly in front of wall B. 7. Set the unit s height so that the laser dot s height matches that of point 2. 8. Without changing the height of the laser, rotate it 180 to place the beam near the mark on the first wall (step 3 / point 1 ). F1 F2 F3 F4 F5 Measure the vertical distance between point 1 and point 3. The difference must not be greater than : S Maximum permissible difference 5 m 3,0 mm 10 m 6,0 mm 15 m 9,0 mm 20 m 12,0 mm S Maximum permissible difference 16 5 1/8 32 10 1/4 49 3 3/8 65 8 1/2 2. Horizontal checking - inclination of the laser line Check the laser line for inclination and perfectly straight projection 1. Mark three points (1, 2 and 3) on the floor at a distance of 5 m /16 5 from each other; the points must be in a perfectly straight line. 2. Position the laser at distance S = 5 m / 16 5 from the line and exactly in front of the middle point you marked = position X 3. Switch the unit on. 4. Measure the height of the laser line at the points. Measurements X1 - X3 5. Reposition the instrument. 6. Position the laser at distance S = 5 m / 16 5 from the line and exactly in front of the middle point you marked = position Y 7. Measure the height of the laser line at the points. Measurements Y1-Y3 1 = X1 - Y1 2 = X2 - Y2 3 = X3 - Y3 G1 G2 G3 G4 G5 The following applies for the differences : Δ ges 1 = Δ 1 - Δ 2 < ± 2mm 5/64 Δ ges 2 = Δ 3 - Δ 2 < ± 2mm 5/64 When calculating, always take note of the preceding prefix!

en H1 H2 H3 I1 I2 K A6 A7 Vertical check You must create a reference to perform this test. Fasten a plumbline near to the wall. The laser unit should now be set up in front of this reference mark (distance Y) and the vertical laser line compared with it. The discrepancy between the centre of the laser line and the reference mark should be no greater than 1 mm ( 3/64 ) over a length of 2 m ( 8 ft ). Checking plumblining 1. Switch the unit on 2. Place the laser so that its down beam is over a reference mark on the floor. 3. Locate the position of the up beam on the ceiling and make a mark. 4. Rotate the laser 180 and realign the down beam over the reference mark on the floor. 5. Locate the position of the up beam on the ceiling and make a mark. 6.Measure the difference D between the two marks on the ceiling, which will be twice the actual error. The difference may not be greater than: 3 mm in 5 m (1/8 in 16 5 ). Replacing the batteries Slide the battery cover (4) in the direction of the arrow and insert new batteries in accordance with the symbols in the battery compartment. Suitable batteries can also be used. Technical data Laser type: Red diode laser, pulsed line-laser, wavelength 635 nm Output: < 1 mw, Laser Class 2 to IEC 60825-1:2007 This product compl. with the appl. requ. of 21CFR, parts 1040.10 and 1040.11. Self-levelling range*: ca. ± 4,5 Levelling accuracy : laser line horizontal*: L1 = ± 0,3 mm/m middle of the laser line L1 = ± 3/16 over 50ft inclination of the laser line : L2 = ± 0,2 mm/m laser line L2 = ± 1/8 over 50ft Up Beam Accuracy*: L3 = ± 0,3 mm/m ± 3/16 over 50 ft Down Beam Accuracy: L4 = ± 0,4 mm/m ± 1/4 over 50 ft Batteries:: 3 x 1,5 V cells Alkaline, Size AA, LR6 LR6 Operating life: Approx. 20 hours (Alkaline) Operating temperature range : -10 C to +50 C / 14 F to +122 F Storage temperature range: -20 C to +60 C / -4 F to +140 F Subject to technical modifications. * When operated within specified temperature range