Agilent E6651A Mobile WiMAX Test Set

Similar documents
Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent J7211A/B/C Attenuation Control Units

PXI WiMAX Measurement Suite Data Sheet

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent CSA Spectrum Analyzer

Agilent N9342C Handheld Spectrum Analyzer (HSA)

PXI LTE FDD and LTE TDD Measurement Suites Data Sheet

Flexible Signal Conditioning with the Help of the Agilent 81134A Pulse Pattern Generator

VSA80000A Ultra-Wideband Vector Signal Analyzer

Agilent N9310A RF Signal Generator

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Agilent E7400A Series EMC Analyzers

Agilent 81150A Pulse Function Arbitrary Noise Generator Applications

Agilent Digital Modulation Lab Station

Agilent NFA Noise Figure Analyzer

Advanced Test Equipment Rentals ATEC (2832)

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Agilent N9320B RF Spectrum Analyzer

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent N9320A Spectrum Analyzer

Agilent 8648A/B/C/D Signal Generators

IQgig-IF TM Technical Specifications

Agilent CSA Spectrum Analyzer

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

WiMAX: , e, WiBRO Introduction to WiMAX Measurements

Agilent 87075C Multiport Test Set

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Product Note E5100A-2

JD7105A Base Station Analyzer

Agilent E9300 Power Sensors E-Series Technical Overview

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

GA GHz. Digital Spectrum Analyzer


Choosing an Oscilloscope with the Right Bandwidth for your Application

PXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

IQxel-M8W TM Multi-DUT Connectivity Test System

Agilent N9343C Handheld Spectrum Analyzer (HSA)

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent MXG Signal Generators

Process Control Calibration Made Easy with Agilent U1401A

Agilent 83711B and 83712B Synthesized CW Generators

IQ2015 TM Connectivity Test System

Agilent E8267C PSG Vector Signal Generator

Solutions for Solar Cell and Module Testing

Agilent N9320B RF Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer

2012 LitePoint Corp LitePoint, A Teradyne Company. All rights reserved.

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Agilent MIMO Manufacturing Solution. Application Note

Agilent Equalization Techniques and OFDM Troubleshooting for Wireless LANs

khz to 2.9 GHz Spectrum Analyzer

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent Technologies Solutions for MB-OFDM Ultra-wideband

Agilent E6651A. Mobile WiMAX Test Set. User s Guide. Agilent Technologies

Agilent U9397A/C FET Solid State Switches (SPDT)

Chapter 5 Specifications

Meet the new E4438C ESG vector signal generator...

Keysight Technologies N9320B RF Spectrum Analyzer

Spectrum Analyzers 2680 Series Features & benefits

DSA700 Series Spectrum Analyzer

Agilent 8657A/8657B Signal Generators

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

IQgig-RF TM Model B Technical Specifications

IQxel-M8 TM Multi-DUT Connectivity Test System

Agilent N9310A RF Signal Generator

Agilent E1969A TD-SCDMA_GSM Fast Switch Test Application

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

From 2G to 4G UE Measurements from GSM to LTE. David Hall RF Product Manager

Digital Spectrum Analyzer GA40XX Series

Agilent E1969A TD-SCDMA_GSM Fast Switch Test Application

Agilent MXG Signal Generators

Agilent 81180A Arbitrary Waveform Generator

Keysight Technologies Performing LTE and LTE-Advanced RF Measurements with the E7515A UXM Wireless Test Set

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Full system level calibration (levels, s-parameters, noise) Full RF source and measure capability Applications Vector network analyzer capability

PXI UMTS Uplink Measurement Suite Data Sheet

Multipurpose Lab Station by Agilent Technologies

TRANSCOM Manufacturing & Education

Agilent E4406A Vector Signal Analyzer

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Agilent N5181A MXG Analog Signal Generator

IQxel-M8 TM Multi-DUT Connectivity Test System

PXI. TD-SCDMA Measurement Suite Data Sheet. The most important thing we build is trust. Total Average Power plus Midamble / Data Power

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

IQgig-RF TM Technical Specifications

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Transcription:

Agilent E6651A Mobile WiMAX Test Set Preliminary Technical Overview Accelerate time-to-market for your IEEE802.16e subscriber station designs The E6651A represents a significant breakthrough in Mobile WiMAX testing. It incorporates flexible base station emulation and RF parametric tests into one integrated unit and extends Agilent s unmatched portfolio of WiMAX test solutions for development, verification, and manufacturing customers. The E6651A Mobile WiMAX Test Set will allow 802.16e-2005 subscriber station designers and manufacturers to move rapidly from development to volume production, and to improve the integrity and quality of products while reducing cost. The Agilent E6651A provides RF signal generation and signal analysis capability up to 6 GHz and includes a full suite of high-speed, precisionaccuracy RF measurements for characterization, calibration, and verification purposes. Certification profiles 1A and 3A are currently supported. Further profiles will be added as the WiMAX standards are formalized. The Mobile WiMAX test set can be extended to enable protocol interoperability and application testing. With realistic base station emulation, the test set offers a controlled environment, with flexibility to configure a wide range of network parameters in which you may test, stress, and debug the protocol and data handling capabilities of your design. With this exciting new product, Agilent helps you get your designs to market faster and more efficiently, and continues to provide comprehensive tools for all stages of your product lifecycle. So, as you move WiMAX forward, Agilent clears the way.

E6651A Features IEEE802.16e OFDMA Mobile WiMAX subscriber station tester Real-time Mobile WiMAX downlink signal modulation Real-time Mobile WiMAX uplink demodulation Base station emulation with MAC, protocol stack TDD synchronization (auto-switching) of signal generator and signal analyzer Ranging code detection Various preamble, FCH, DL-MAP, UL-MAP, burst configuration settings DL PUSC, DL FUSC, UL PUSC Mobile WiMAX radio (PHY) measurements OFDM constellation and EVM (BPSK, QPSK, 16QAM, 64QAM) DL preamble EVM, pilot EVM, data EVM, symbol EVM UL data EVM Error vector spectrum, error vector versus time CCDF (complimentary cumulative distribution function) Channel power, occupied bandwidth Transmitter Modulation and coding Ranging support Power level control Synchronization Maximum output signal Frequency accuracy Channel bandwidth measurement Spectral flatness Relative constellation error (EVM) Receiver Maximum tolerable signal Maximum input signal Sensitivity Cyclic prefix Preambles Frame duration timing RSSI BER, PER, FER BER versus CINR Mobile WiMAX MAC test items Response time for MAC management request message Initial ranging procedure verification under exceptional RF conditions Dynamic service flow status for given conditions SS MAC layer verification and performance test 2

E6655A WiMAX Lab Application Features of emerging mobile devices are increasing the complexity and software content. Only by testing these features in a realistic network environment can you ensure the quality of your subscriber equipment. The WiMAX lab application provides convergence service network emulation to allow you to do this supporting real-time, end-to-end functional test of your WiMAX design. Controlled network environment no need to run tests on a live network Verify correct operation, stress test your WiMAX device by running multiple applications Configure key elements of MAC operation Note that network emulation requires a customer-supplied PC dedicated to act as a gateway between the application server and E6651A. N6421A WiMAX Protocol Logging and Analysis Quickly collect and interpret wireless protocol messaging, verify functionality, and isolate and resolve protocol problems when developing subscriber stations and applications. Real-time logging and decodes of PHY and MAC layer protocol Post-capture analysis of protocol log files Log filtering makes it easy to sort through the huge volume of messaging to and from the WiMAX device N6422C WiMAX Wireless Test Manager Agilent's test manager software provides ready-to-use tests, test plans, test sequencing, and menu-selectable hardware support for quick and easy automation of device calibration and test processes. An integrated test development wizard simplifies making software modifications and adding user-defined tests. The test manager runs on a Windows PC and supports Agilent test system hardware. Ready-to-use tests, test plans, and test sequencing Customize test steps and test parameters by using Wizards to reduce time on coding Results can be logged, compared, and post processed Note that the test manager requires customer-supplied Microsoft Visual Studio.NET software. 3

4 Example Configurations

E6651A WiMAX Test Case Coverage The E6651A can be used as part of a pre-conformance test system and supports the performance of the following wave 1 RF measurements, as referenced in the Mobile WiMAX MRCT v1.0 Test case reference Test case name Measurement Supported MS-01.1 MS receiver maximum tolerable signal Yes ++ MS-02.1 MS receiver preamble Yes + MS-03.1 MS receiver cyclic prefix Merged with MS-01.1 MS-04.1 MS receiver RSSI measurements Yes + MS-05.1 MS receiver physical CINR measurements Yes ++## MS-07.1 MS receiver adjacent and non-adjacent channel selectivity Yes + MS-08.1 MS receiver maximum input signal Yes MS-09.1 MS receiver sensitivity Yes # MS-10.1 MS transmit and receive HARQ Yes* MS-10a.1 MS transmit HARQ Yes* MS-10b.1 MS receive HARQ Yes* MS-11.1 MS receiver PHY support for handover Yes* ++ MS-12.1 MS transmitter modulation and coding, Yes cyclic prefix, and frame duration timing MS-13.1 MS transmit ranging support Yes MS-14.1 MS transmitter modulation and coding Merged with MS-12.1 MS-15.1 MS transmit power dynamic range and relative step accuracy Yes MS-16.1 MS transmit closed and open loop power control MS-17.1 MS transmitter spectral flatness Yes MS-18.1 MS transmitter relative constellation error Yes** MS-19.1 MS transmit synchronization Yes MS-20.1 MS transmit/receive switching gap Yes Yes PER is measured by ping method, rather than ACK/NACK method. + Additional RF source(s) required for part of the test. ++ Additional RF source(s) required for all of the test. # Fader required. ## Fader required and instantaneous fading channel gains must be known. * Verification required for specific chipsets. ** Active subcarriers only. Unused subcarrier RCE is not measured Wave 2 RF measurements are in process, but at the time of printing this document the WiMAX MRCT test case definition has not been finalized. 5

E6651A Specification The test set will meet its warranted performance after one hour within the stated environmental operating range plus one hour after turn on. Unless otherwise stated all specifications are valid over the operating temperature range. Supplemental characteristics are intended to provide additional information, useful in applying the instrument by giving typical (expected), but not warranted, performance parameters at room temperature (20 to 30 C). These characteristics are shown in italics or labeled as nominal. Signal analyzer specifications Frequency Frequency range Frequency resolution Frequency accuracy Modulation analysis bandwidth Amplitude Measurement range 1 Absolute measurement accuracy 2 Residual response Spurious responses 3 Performance Quantization Residual (EVM) 4 ACLR 5 Pass-band ripple Triggering 450 MHz to 2.7 GHz (E6651A-503) 450 MHz to 5.99 GHz (E6651A-506) 1 Hz (< 3 GHz), 2 Hz ( 3 GHz) Same as frequency reference 10 MHz +27 to 50 dbm ±0.5 db (attenuator 0 to 31 db) ±1 db (E6651A-506 attenuator 32 to 62 db, or 32 to 59 db for E6651A-503) 85 dbm at 10 khz RBW 55 dbc (excluding IF image) 45 dbc (including IF image) 14-bit ADC 0.5% (preamble), 1.5% (pilot) 43 dbc ±0.5 db (over 16 MHz bandwidth) Automatic 1 Verified using a typical WiMAX signal of 8.75 MHz bandwidth 2 Verified using CW measurements 3 At 2345 MHz, span 16 MHz 4 Error Vector Magnitude measured at input frequency 2345 MHz, level 20dBm 5 Input frequency 2345 MHz, level 15dBm 6

Signal generator specifications Frequency Frequency range Frequency resolution Frequency accuracy Amplitude WiMAX preamble power range 6 CW power range CW power accuracy Resolution Performance Phase noise at 3GHz Residual (EVM) 7 ACLR 8 Harmonics Subharmonics Non-harmonic spurious 9 450 MHz to 2.7 GHz (E6651A-503) 450 MHz to 5.99 GHz (E6651A-506) 1 Hz (< 3 GHz), 2 Hz ( 3 GHz) Same as frequency reference 22 to 102 dbm (< 3 GHz) 27 to 102 dbm ( 3 GHz) 7 to 127 dbm (< 3 GHz) 12 to 127 dbm ( 3 GHz) Frequencies < 3GHz ± 0.6 db ( 7 to 78 dbm) ± 0.75 db ( 78 to 93 dbm) ± 1.0 db ( 93 to 113 dbm) Frequencies 3Ghz to 5.99 GHz ±1.0 db ( 12 to 100 dbm) 0.01 db 102 dbc/hz @ 10 khz offset 0.5% (preamble), 1.5% (pilot) 50 dbc (±4.77 MHz offset) 56 dbc (±9.27 MHz offset) 30 dbc (1GHz CW, 7dBm) 30 dbc (6GHz CW, 12dBm) 60 dbc, offsets > 10kHz (E6651A-503) 70 dbc, offsets > 10kHz (E6651A-506) General Specifications RF input/output impedance 50 Ω (nominal) RF input /output VSWR < 1.5:1 (<3 GHz) < 2.0:1 (3 to 6 GHz) Maximum safe input level +27 dbm Interfaces USB, LAN, trigger in/out RF reference input/output 10 MHz, 4 dbm ±2 db Frequency reference stability ±1E-8 Frequency reference aging rate 1E-9/day, 1E-7/year Power requirement 90 to 250 Vac, 50/60 Hz, 590W Size (w x d x h) 444 mm x 647 mm x 222 mm Weight 25.8 kg Operating temperature 0 to 50 C Operating humidity 5 to 85% non-condensing Storage temperature 40 to 71 C Storage humidity 0 to 90% at 65 C Operating altitude Up to 2000 m 6 Verified using a typical WiMAX signal of 8.75 MHz bandwidth 7 Error Vector Magnitude measured at output frequency 2345 MHz 8 Output power 20 dbm, measured with 300 khz RBW, 300 Hz VBW at 2345 MHz 9 CW measurement, output 12 dbm, 2345 MHz 7

Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For More Information www.agilent.com Further information on the E6651A and associated products is available at: www.agilent.com/find/e6651a Further information on Agilent WiMAX solutions is available at: www.agilent.com/find/wimax For more information on repair and calibration services, go to www.agilent.com/find/removealldoubt For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2111 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 1/17/05 Windows, Visual Studio.NET, and Microsoft are U.S. registered trademarks of Microsoft Corp. Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2007 Printed in USA, May 18, 2007 Preliminary document 8