CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta change-over, ON-delayed " Transition time 0 ms fixed " 1 n/c and 1 n/o contact " LEDs for status indication " Width.5 mm CT-SDE 1 Thumbwheel for the fine adjustment of the starting time U: green LED - Supply voltage R: red LED - Output relay energized Approvals a culus b GL e GOST f CCC Marks g CE c C-Tick Order data Type Supply voltage Time range Order code CT-SDE 110-10 AC 0.-0 s 1SR 550 10 R4100 CT-SDE 4 AC/DC, 0-40 AC 0.-0 s 1SR 550 17 R4100 CT-SDE 80-415 AC 0.-0 s 1SR 550 1 R4100 Application Their conception makes the CT-E range timers ideal for serial applications. Operating mode The fine adjustment of the time delay is made via the front-face thumbwheel. Function diagram I Star-delta change-over (Star-delta starting) Applying supply voltage to terminals A1-A, energizes the star contactor (K1) and the line contactor (K) and begins the set starting time. When the starting time is complete, contact 15-16 de-energizes the star contactor (K1). Now, the fix transition time starts. When the transition time is complete, contact 15-18 energizes the delta contactor (K). A1-A/B1 15-18 15-16 green LED red LED Star contactor Delta contactor CDC 5 14 F005 t 1 t t 1 = adjustable starting time t = fixed transition time 1
Connection diagrams J CT-SDE A 16 18 CDC 5 16 F0005 16 18 A ersion: 1SR 550 10 R4100 A1-A Supply: 110-10 AC 15-16/18 c/o contact J CT-SDE B1 A B1 16 18 CDC 5 161 F0005 16 18 A ersion: 1SR 550 17 R4100 A1-A Supply: 0-40 AC A1-B1 Supply: 4 AC/DC 15-16/18 c/o contact J CT-SDE A 16 18 CDC 5 16 F0005 16 18 A ersion: 1SR 550 1 R4100 A1-A Supply: 80-415 AC 15-16/18 c/o contact
Technical Data Input circuits Supply voltage A1-A 110-10 AC A1-A 0-40 AC A1-A 80-415 AC B1-A 4 AC/DC Power consumption 110-10 AC approx..0 A 0-40 AC approx..0 A 80-415 AC approx..0 A 4 AC/DC approx. 1.0 A/W Supply voltage tolerance -15...+10 % Supply voltage frequency AC/DC ersion DC or 50/60 Hz AC ersion 50/60 Hz Duty time 100 % Timing circuit Time range for each device 1 time range 0. - 0 s Star-delta transition time 0 ms Recovery time < 400 ms Repeat accuracy (constant parameters) < 1 % Timing error within the supply voltage tolerance range < 0.5 % / % d U Timing error within operating temperature range < 0.1 % / C Indication of operational states Supply voltage / timer green LED Output relay energized red LED Output circuits 15-16/18 Number of contacts relay, 1 c/o contact Contact material AgCdO Related voltage acc. to DE 0110, IEC 60947-1 50 Maximum switching voltage 50 AC, 50 DC Rated switching current acc. to IEC 60947-5-1 AC-1 (resistive) 0 4 A AC-15 (inductive) 0 A DC-1 (resistive) 4 4 A DC-15 (inductive) 4 A Maximum lifetime mechanical 0 x 10 6 switching cycles electrical (AC-1, 0, 4 A) 0.1 x 10 6 switching cycles Short circuit proof, max. fuse rating n/c 10 A fast, operating class gl n/o 10 A fast, operating class gl General data Enclosure width.5 mm length 78.0 mm depth 78.5 mm Wire size fine-strand with wire end ferrule x 1.5 mm fine-strand without wire end ferrule rigid Weight approx. 80 g (.8 oz) Mounting position any Degree of protection enclosure / terminals IP50 / IP0 Temperature operating -0...+60 C storage -40...+85 C Mounting DIN rail (EN 500) Standards Product standard IEC 6181-1, EN 6181-1 EMC Directive 89/6/EEC Electromagnetic compatibility IEC 61000-6-, EN 61000-6-4 ESD acc. to IEC 61000-4-, EN 61000-4- level 6 k / 8 k HF radiation resistance acc. to IEC 61000-4-, EN 61000-4- level 10 /m Burst acc. to IEC 61000-4-4, EN 61000-4-4 level k / 5 khz Surge acc. to IEC 1000-4-5, EN 61000-4-5 level 4 k L-L HF line emission acc. to IEC 1000-4-6, EN 61000-4-6 level 10 Low oltage Directive 7//EEC Operational reliability acc. to IEC 68--6 6 g Mechanical resistance acc. to IEC 68--6 10 g
Approvals / marks Approvals culus, GL, GOST and CCC Marks CE and C-Tick Isolation data Rated insulation voltage between supply circuit, acc. to DE 0110, IEC 60947-1 supply up to 40 : 00 control circuit and output circuit supply up to 440 : 500 Rated impulse withstand voltage between all acc. to DE 0110, IEC 664 4 k / 1.-50 µs isolated circuits Test voltage between all isolated circuits.5 k, 50 Hz, 1 min. Pollution category acc. to DE 0110, IEC 664, IEC 55-5 III/C Overvoltage category acc. to DE 0110, IEC 664, IEC 55-5 III/C Environmental testing acc. to IEC 68--0 4 h cycle time, 55 C, 9 % rel., 96 h Load limit curves AC load (resistive) 00 00 100 80 60 50 40 0 0 CDC 5 194 F005 10 0.1 0. 0.5 1 4 6 10 I A DC load (resistive) 00 00 100 80 60 50 40 0 0 CDC 5 19 F005 10 0.1 0. 0.5 1 4 6 10 I A Derating factor F for inductive AC load 1.0 0.9 0.8 F 0.7 0.6 0.5 CDC 5 19 F005 0.1 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Contact lifetime /switching cycles N N 10 5 9 8 5 4 10 4 1 4 5 6 7 8 I A CDC 5 191 F005 0 50 Hz 1 AC 60 cycles/h 4
Dimensional drawings Dimensions in mm 88,5.48 81.19,5.886 78,5.09.07 78 CDC 5 189 F0005 5
Druckschrift-Nummer. CDC 111 001 D00 Printed in the Federal Republik of Germany (07/07) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 8 691 Heidelberg, Deutschland Postfach 10 16 80 69006 Heidelberg, Deutschland Internet http://www.abb.com/lowvoltage -> Control Products -> Electronic Relays E-Mail epr-support@stotzkontakt.de