ANALYTICAL - COMPLEXITY MADE SIMPLE

Similar documents
DissolvedOxygenMonitor

Parts Per Million Dissolved Oxygen Systems

CHANFLO 2500 / 3000 Open Channel Flowmeters

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Analytical Transmitters

Isolated STs Series, 4-20 ma Dissolved Oxygen and Temperature transmitter for in-line or submersible applications Insertion (in-line)

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Sarasota CM200 Sarasota HME900 Density Converter Electronics

DISSOLVED OXYGEN TRANSMITTER

Signet 9950 Dual Channel Transmitter

ph or ORP Transmitter

Signet 9950 Dual Channel Transmitter

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Digital conductivity transmitter

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Infocal 9 Energy calculator

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

ULTRASONIC FLOW METER FT101

inc Channel 1 ph, ORP (Redox) Conductivity or Dissolved Oxygen Transmitter Channel 2 Temperature Transmitter Black (V-) Green (V-)

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Kotron Model 82 CE RF Level Transmitter

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

E l e c t r o m a g n e t i c f l o w m e t e r s

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

FLOWMETER. Siemens MAG 5000/6000. Overview

Magnetostrictive Level Transmitter

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Dissolved Oxygen Transmitter

Features and Applications

MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401

DIGITAL OXYGEN METER. Model : DO-5510

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

Electromagnetic Flow Transmitter

PAD - Heavy Duty Differential Pressure Trasmitter

The transducer component converts the measured signal and displays the actual value.

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

B850 Boiler House Energy Monitor

Rosemount 3101, 3102, and 3105

LST400 Ultrasonic level / open channel flow transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Model Q40CT. System Features. Toroidal Conductivity Monitor...

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Mass and Volume Flow Transmitter

2-Wire Toroidal Conductivity Transmitters Series APT2000 Specifications

Technical Information Memosens CCS50D

MEAS CAL ALARM CONF APT2000 TC

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters

Signet 9900 Transmitter

Technical Information Orbipore CPS91D and CPS91

Signet 9900 Transmitter

Specification DataFile

Signet 9900 Transmitter

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Non-Submersible Industrial Pressure Transducer

B850 Boiler House Energy Monitor

Digital inductive conductivity transmitter

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

RCM DIRECT READING FLOWMETER

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

General Specifications

Digital flowmeter for continuous flow measurement

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Digital flow transmitter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Ambient Conditions. Operating Conditions. Pressure

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Echotel Model 911/921 Ultrasonic Level Switches

SonoMeter 31 Energy Meters

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Mass Flow and Density Transmitter with FOUNDATION fieldbus

Two-Wire Programmable Transmitter for:

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

Model Sono-Trak Transit Time

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

mass flowmeter for compressed air

General Specifications

Thermo Scientific Orion Star A111 ph Benchtop Meter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Level Limit Switch nivotester FTL 325 P

Conductivity measurement SmarTec S CLD 132

Transcription:

EVITA OXY Dissolved Oxygen Meter DANFOSS ANALYTICAL - COMPLEXITY MADE SIMPLE

How it works The EVITA OXY dissolved oxygen meter operates on Clark s principle: To initiate measurement a polarization voltage is applied between two electrodes. Gold is used as cathode and a silver wire as anode, both placed in an electrolytic system separated from the liquid by a gas permeable diaphragm. Oxygen molecules penetrating the diaphragm are attracted to the positively charged gold cathode. A small electric current is thereby established between the gold cathode and silver anode. The transmitter converts this current into a usable 4-20 ma signal. Real diaphragm puncture detection - the diaphragm is constantly monitored and any rupture or other source of leakage is instantly detected Increased sensor life - an 18 silver wire is used to make the surface area of the anode as large as possible, increasing operating life to 2-3 years High reliability and accuracy - a prestressed, bonded diaphragm ensures predictable permeability at changing temperatures and prevents contamination of the electrolyte Automatic cleaning - the self-cleaning ball float with specially designed fins keeps the sensor clean for months - reducing maintenance time to a minimum High accuracy and noise immunity - the 4-20 ma HART transmitter is mounted directly behind the oxygen sensor and temperature sensor, ensuring high accuracy and noise immunity For installation everywhere - the EVITA OXY transmitter is intrinsically safe, approved by both CENELEC and UL Long meter cables - the two-wire 4-20 ma HART transmitter allows up to 3,000 ft between transmitter and display/plc Built-in auto calibration - a tilt-switch function initiates an automatic calibration sequence when the sensor is tilted or turned over

New ball float design - the special fins increase turbulence and keep the sensor clean for typically 2-3 months Maintenance at a minimum Perhaps the greatest benefit obtained with the EVITA OXY sensor is that maintenance is reduced to a minimum: We have perfected what we invented 20 years ago by adding four fins to the meter design further improving the self-cleaning effect. There is no need for grinding stones, fresh water, chemicals etc. When cleaning is necessary after 2-3 months of operation in the aeration tank, all you need to do is wipe the sensor with a cloth. Flexible communication Choosing the right communication protocol for your equipment can be difficult: Which protocol will meet the requirements for the years to come? Danfoss has met this challenge by making the EVITA OXY meter extremely flexible. You can choose the communication module that fits your needs today and change it later when new protocols are developed. Individual modules with different communication protocols can be mounted in the USC 6000 signal converter without any use of tools. The OXY 4100/4150 transmitter communicates with either the USC 5000/6000 signal converter or a PLC via HART communication, using only two wires. Automatic cleaning - after three months of operation in an aeration tank the sensor is still measuring accurately

Automatic calibration The EVITA OXY is extremely easy to use. There is no need for special cables, no complicated diagrams to follow, and calibration is performed automatically. Simply press a button and the system calibrates itself within minutes. Alternatively, just tilt the transmitter: a tilt switch will initiate calibration. There is no need to calibrate the zero point either. The low-cost disposable OXY 1100 sensor can be exchanged before zero-point calibration becomes necessary. The automatic calibration function ensures that EVITA OXY remains as accurate as the day you installed it. Oxygen profile control a money saver There can be large fluctuations in the oxygen concentration anywhere in an aeration tank. By installing several oxygen meters in each tank, the oxygen profile can be evened out, energy can be saved and the process becomes better tuned to fluctuations in the BOD load. The EVITA OXY 4100/4150 transmitter is a cost-saving system for oxygen profile control. You can connect up to 15 transmitters to one PLC using only two wires and the HART communication multidrop mode to transmit oxygen concentrations. Replacement in five minutes All dissolved oxygen meters require regular sensor replacement. Danfoss has made this process so simple that it can be performed in five minutes with no mistakes possible. The EVITA OXY monitors sensor life and alerts you the moment replacement is required. Simply unscrew the collar that holds the sensor in place and insert the new sensor. Spare sensors can be stored indefinitely without diminishing performance. It only starts to operate when connected to the transmitter. ppm ppm 0 0 days days

TRANSMITTER OXY 4100 OXY 4150 Measuring range Dissolved oxygen: 0 to 10-500% Dissolved oxygen: 0 to 10-500% 0 to 0.1-50 mg/l or ppm 0 to 0.1-50 mg/l or ppm Temperature 32 F to 160 F Temperature 32 F to 160 F Measuring uncertainty Oxygen: ± 0.5%, Temperature: ± 0.2 F Oxygen: ± 0.5%, Temperature: ± 0.2 F Current outputs 4-20 ma (scaleable by HART ), galvanic isolation 4-20 ma (scaleable by HART ), galvanic isolation Max load: 750 ohm @ 30 VDC Max load: 750 ohm @ 30 VDC Enclosure NEMA 6P NEMA 6P Ambient temperature Storage: -40 F to +160 F Storage: -40 F to +160 F Operation: -40 F to +140 F Operation: -40 F to +140 F Media: 32 F to +122 F Media: 32 F to +122 F Power supply 12-30 VDC 12-30 VDC Automatic calibration Compensating for temp. (pressure, salinity, Compensating for temp. (pressure, salinity, and humidity by entering values using HART ) and humidity by entering values using HART ) Approvals UL, CE and C-tick approved UL, CE and C-tick approved EEx ia IIB T4 (CENELEC) intrinsically safe EEx ia IIB T4 (CENELEC) intrinsically safe Emission: EN 50081-1, Immunity: EN 50082-2 Emission: EN 50081-1, Immunity: EN 50082-2 SIGNAL CONVERTER USC 5000 USC 6000 Measuring range Dissolved oxygen: 0 to 10-500% Dissolved oxygen: 0 to 10-500% 0 to 0.1-50 mg/l or ppm 0 to 0.1-50 mg/l or ppm Temperature 32 F to 160 F Temperature 32 F to 160 F Measuring uncertainty Oxygen: ± 0.5%, Temperature: ± 0.2 F Oxygen: ± 0.5%, Temperature: ± 0.2 F Current outputs One 4-20 ma (scaleable), galvanic isolation Two 4-20 ma (scaleable), galvanic isolation Max load: 800 ohm Max load: 800 ohm Relay outputs None 3 relay outputs SPST (48 V d.c. 4A) Display Back-lit alphanumeric LCD display Back-lit alphanumeric LCD display Enclosure Converter module: NEMA 6 Converter module: NEMA 6, Rack Mount: NEMA 1 Ambient temperature Storage: -40 F to +160 F Storage: -40 F to +160 F Operation: -40 F to +140 F Operation: -40 F to +140 F Power supply 115-230 VAC +10% - 15%, 50/60 Hz, 5 VA 115-230 VAC +10% - 15%, 50/60 Hz, 5 VA 11-30 VDC Automatic calibration Compensating for temperature, barometric Compensating for temperature, barometric pressure, humidity and salinity pressure, humidity and salinity Approvals UL, CE and C-tick approved UL, CE and C-tick approved Emission: EN 50081-1, Immunity: EN 50082-2 Emission: EN 50081-1, Immunity: EN 50082-2 OXY 1100 sensor Mounting bracket Principle Replaceable Clark sensor measuring dissolved Bracket mounted on handrail with pivot oxygen. Typical life 2-3 years function to hold 1 1 / 2 PVC pipe Working temperature Storage: 32 F to +160 F Storage: -40 F to +160 F Media: 32 F to +122 F Operation: -40 F to +160 F Material Diaphragm: 50µm FEP Teflon Base: Stainless steel Cathode: Gold, Anode: Silver, Electrolyte: KCl Holder: Carbon & fibreglass reinforced polyamide Weight 0.5 Oz 1.75 lbs

Partnership with commitment Purchasing Danfoss products gives you not only high quality and unsurpassed reliability, but also a lasting partnership that will always provide you with the technology of tomorrow. Danfoss is well-known for accurate mechanical and electronic systems, and is perhaps even more renowned for its intelligent, mechatronic products. Water treatment processes always have been a vital part of our business, and today our commitment to the water and wastewater industry is stronger than ever. Our wastewater product offering includes flowmeters, water valves, pressure transmitters and frequency converters. Supplemented with the EVITA INSITU colorimetric nutrient sensors and EVITA OXY dissolved oxygen meters, we believe our many products make calling Danfoss worthwhile. ISO 14001 EVITA Nutrient sensors www.danfoss.com/analytical Flowmeters www.danfoss.com/instrumentation Water valves www.watervalves.com/uk VLT Frequency converters www.danfoss.com/drives Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss Water & Wastewater Division 8800 W. Bradley Road Milwaukee, WI 53224-9541 Phone: 1 414 355 8800 Fax: 1 414 355 6117 www.us.water.danfoss.com Davis Controls Limited 2200 Bristol Circle Oakville, Ontairo L6H 5R3 Canada Phone: (905) 829-2000 Fax: (905) 829-2630 DKCFE.PB.200.B3.22 / 521B0029 Produced by Danfoss G1 advertising agency 01.01.APH.JN.AO