Control module CP-A CM

Similar documents
Control module CP-A CM

Type CP-S, CP-C & CP-A Switch mode

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relays

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDD.22

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-TGD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-SDS.22

Three-phase monitoring relay

Power supply CP-E 24/0.75

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PFE and CM-PFE.2

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-E 24/2.5

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Power supply CP-D 24/1.3

Power supply CP-E 24/20.0

Power supply CP-E 24/2.5

Power supply CP-D 12/2.1

Power supply CP-T 24/10.0 Primary switch mode power supply

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PVE

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

Primary switch mode power supplies Product group picture

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Power supply CP-T 24/20.0 Primary switch mode power supply

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Electronic timer CT-MFS.21

Liquid level monitoring relay CM-ENS.2x

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Power supply CP-T 48/20.0 Primary switch mode power supply

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

CP-T range Product group picture

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

CP-E range Benefits and advantages

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Three-phase monitoring relays Product group picture

Thermistor motor protection relays

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Table of contents

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

CP-T range Benefits and advantages

Moeller Electric Corporation

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Thermistor motor protection relays

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Zelio Control Measurement Relays

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Analog signal converters CC range

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Semiconductor contactors, Solid-state relays

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Pluggable interface relays CR-P Pcb relays

Transcription:

2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950, CAN/CSA C22.2 No. 60950 D GOST K CB scheme pending a SENSE OUT: +, +, : terminals output b IN 1: 11 12/14, IN 2: 21 22/24: terminals input c IN 1 < V: rotary switch threshold value adjustment for channel 1 d IN 2 < V: rotary switch threshold value adjustment for channel 2 e OUT: green LED output voltage > 3 V f IN 1: green LED input voltage at channel 1 OK g IN 2: green LED input voltage at channel 2 OK h Circuit diagram Marks a CE b C Tick pending Order data Type Description Order code CP-A CM Control module The CP A CM provides monitoring of the input signals of the redundancy unit CP A RU. Application The control module CP A CM provides monitoring of the input signals of the redundancy unit CP A RU. Operating mode Control of input voltages of CP A RU with CP A CM The control module CP A CM indicates the presence of both input voltages of the CP A RU via LEDs and energized output relays. The threshold values for the output relays are adjustable separately per channel from 14 to 28 V. If, by a fault (e.g. failure of a power supply, blown fuse), the voltage in a channel drops below the adjusted threshold value, the corresponding output relay de energizes. The green LEDs IN 1, IN 2 glow, if the corresponding voltage exceeds the adjusted threshold value. The green LED OUT glows, if the output voltage is higher than 3 V.

Example(s) of application CP A RU with CP A CM for monitoring of two power supplies In case of fault: Fault signal If both relays are de energized, the voltages of both channels are below the adjusted threshold value (e.g. 20 V). This could mean, that both power supply units failed or are switched off, or that there is an overload on the secondary side. Momentary de energization of the relays may be caused by inrush current of a connected load, during starting. If one of the two relays de energizes, this can indicate that the primary power supply unit failed or is switched off, and the redundant power supply is now supplying power to the load. + - + - CP-A RU CP-A CM CP-S / CP-C CP-S / CP-C Relay message channel 1 < 20 V + + - - Load Relay message channel 2 < 20 V 2CDC 272 028 F0205 CP A RU with CP A CM for monitoring of one power supply In case of fault: Transfer to an alternative power supply The following example of application shows transferring to an alternative power supply (in this example a battery) after a failure in the primary power supply unit. + - + - CP-A RU CP-A CM CP-S / CP-C Battery L1 N PE L N PE + + - - Load 2CDC 272 029 F0205 Installation Mounting The module is plugged and fixed as shown in the accompanying picture onto the front side of the redundancy unit CP A RU. Doing so, the pre cut front foil of the redundancy unit is penetrated by the latching hooks and the plug contacts. The module must not be plugged in when the power is on. 2CDC 272 073 F0b04

Installation Demounting The module is removed as shown in the accompanying picture. The module must not be removed when the power is on. 2CDC 272 074 Fb004 Electrical connection Output side [SENSE OUT ++ ] The terminals SENSE OUT + + are situated on the + and potential on the output side and can be used for signalling. Electrical connection Input side [IN 1 (11 12/14) and IN 2 (21 22/24)] Message input 1 OK Volt free (dry/floating) change over contact: 11 14 closed and 11 12 open, if the voltage in channel 1 (IN 1) of the CP A RU exceeds the threshold value adjusted at IN 1 <V. 11 12 closed and 11 14 open, if the voltage in channel 1 (IN 1) of the CP A RU drops below the threshold value adjusted at IN 1 <V. Message input 2 OK Volt free (dry/floating) change over contact 21 24 closed and 21 22 open, if the voltage in channel 2 (IN 2) of the CP A RU exceeds the threshold value adjusted at IN 2 <V. 21 22 closed and 21 24 open, if the voltage in channel 2 (IN 2) of the CP A RU drops below the threshold value adjusted at IN 2 <V. Connection diagram(s) IN1 IN2 Sense OUT + + - 11 12 14 21 12 11 14 22 21 24 2CDC 272 050 F0b07 22 24 IN 1 11 12/14 IN 2 21 22/24 Sense OUT +, +, Message input 1 (IN 1) OK Message input 2 (IN 2) OK + and potential of the output side

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, if nothing else indicated Input circuits - Supply circuits Rated input voltage U in Typical current / power consumption / 1 W Input voltage range DC 13 28 V DC Rated input current Measuring circuit Monitoring function Measuring voltage Threshold value(s) at rated sense load and 120 ma undervoltage monitoring rated operational voltage 14 28 V Hysteresis related to the threshold value fix: 3 5 % Accuracy / Tolerance Maximum measuring cycle Indication of operational states 10 % of full scale value 6 ms Status of input 1 IN 1: green LED V: voltage at input 1 > than threshold 1 = no faults existing Status of input 2 IN 2: green LED V: voltage at input 2 > than threshold 2 = no faults existing Status of output OUT: green LED V: U out > 3 V = no faults existing Output circuits Kind of output 11 12/14 relay, 1 c/o (SPDT) contact Contact material Operating principle Rated operational voltage U e (IEC/EN 60947 1, VDE 0110) Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current 21 22/24 relay, 1 c/o (SPDT) contact AgNi closed circuit principle 250 V 24 V / 10 ma 250 V / 1 A Rated operational current I e (IEC/EN 60947 1) AC12 (resistive) at 230 V 1 A AC15 (inductive) at 230 V 1 A DC12 (resistive) at 24 V DC13 (inductive) at 24 V 1 A 1 A Rating according UL 508 General purpose (GP) 250 V AC 1 A Maximum fuse rating to achieve short-circuit protection n/o contact n/c contact 2 A, gl 2 A, gl

Sense output (+, +, -) Sense output voltage Sense output current Maximum fuse rating 13-28 V DC 0.1 A For applications acc. UL the sense output shall be provided with a listed DC fuse 3 A General data Duty time 100 % Dimensions (W x H x D) when mounted Material of enclosure Weight Mounting position Mounting 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 inches) UL 94 V0 0.063 kg (0.14 lb) plugged onto redundancy unit CP A RU snap on mounting without any tool Degree of protection enclosure / terminals IP20 / IP20 Class of protection II Electrical connection all circuits Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule Screw connection 0.2 2.5 mm 2 (24 14 AWG) 0.2 2.5 mm 2 (24 14 AWG) rigid 0.2 4 mm 2 (24 12 AWG) 7.5 mm (0.3 inches) 0.4 0.6 Nm Environmental data Ambient temperature range operation 25...+70 C storage 40...+85 C Damp heat (IEC/EN 60068 2 3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068 2 6) Shock (IEC/EN 60068 2 27) 93 % at +40 C, no condensation 3k3 Isolation data Rated isolation voltage U i (IEC/EN 60947 1, EN 50178, VDE 0160) Rated impulse withstand voltage U imp (type test) (IEC 664, VDE 0160) Power frequency withstand voltage test (Test voltage, routine test) Basic insulation all circuits all circuits 250 V 2.5 V 1.2 kv AC Protective separation (EN 50178) Input circuit / Output circuit yes Pollution degree (IEC/EN 60950) 2 Overvoltage category (IEC/EN 60950) 500 V II

Dimensions in mm 54 [2.13 ] 56,5 [2.22 ] 24 [0.94 ] 2CDC 272 016 F0b07 CP-