AS-LED COMBINED OBSTRUCTION LIGHTS THE ADVANTAGES OF THE AS-LED COMBINED OBSTRUCTION LIGHT AT A GLANCE The AS-LED Combined Obstruction Lights of aqua signal are flashing lights that combine daylight and night light indication. They are used for aviation obstacles, such as wind power plants, radio masts, towers, chimneys or sky scrapers. All models comply with the requirements of the International Civil Aviation Society (ICAO), the French Directorate General for Civil Aviation (dgac) and the German administrative regulations for the indication of aviation obstacles AVV. The light regulation takes place via central control and monitoring units. - Daylight and night light indication in one housing - Horizontal 360 angle of radiation - Light intensity: dimmable depending on visibility range (acc. to AVV) - No additional reflectors required - Long life service thanks to the use of LED - Increased reliability due to decentralised electronics - Housing made of seawater resistant anodized aluminium (acc. to IP 66) - Weight under 18 kg AS-MI-LED WHITE/RED AS-MI-LED WHITE/WHITE AS-MI-LED WHITE/W-RED AS-MI-LED WHITE - 2000 cd white night light indication - 170 cd white night light indication - Aviation obstacles according to ICAO type A and B as well as type A and C - Aviation obstacle according to ICAO type A - Particularly for wind power plants - Aviation obstacle according to ICAO type A acc. to AVV Article number: 3334 8860 00 Article number: 3334 0860 00 Article number: 3334 8760 00 Article number: 3334 0860 02 4 5
A S - L E D O B S T R U C T I O N L I G H T S THE ADVANTAGES OF THE AS-LED OBSTRUCTION LIGHT AT A GLANCE The AS-LED Obstruction Lights of aqua signal are flashing lights to identify aviation obstacles such as radio masts, wind power plants, chimneys and high buildings at nighttime. The obstruction lights just like the LED Combined Obstruction Lights are Of course they comply with the requirements of the International Civil Aviation Society (ICAO), the French Directorate General for Civil Aviation (dgac) and the German administrative regulations for the indication of air space obstacles AVV. - Small compact construction > weight under 12 kg - Horizontal 360 angle of radiation - Light intensity: dimmable depending on visibility range - No additional reflectors required - Long life service thanks to the use of LED - Increased reliability due to decentralised electronics - Housing made of seawater resistant aluminium (acc. to IP 66) controlled via a central control and monitoring unit. AS-MI-LED RED AS-MI-LED WHITE AS-LED W-RED AS-LED W-RED 2007-2000 cd white night light indication - 170 cd W-red night light indication - 170 cd W-red night light indication - Aviation obstacles acc. to ICAO type B and C and acc. to AVV - Aviation obstacle according to ICAO type A - To identify wind power plants acc. to AAV - To identify (offshore) wind power plants acc. to AAV Rumania/RCAA and Hungary/NTA Article number: 3334 2860 00 Article number: 3334 0860 10 Article number: 3334 2730 10 Article number: 3334 2730 02 Also available: AS-MI-LED RED 2000 RED/CAA - Acc. to CAA (United Kingdom) Article number: 3334 2730 20 AS-MI-LED RED/FAA - FAA certificate (USA) 150/5345-43F (pending) 6 7
C O N T R O L C A B I N E T S THE ADVANTAGES OF CONTROL CABINETS AT A GLANCE aqua signal control cabinets hold the electronic components to control obstruction and obstacle lights. They are available in a standard version. Individual customer requests can also be realised. - Compact structure - Easily accessible electronics - Client specific configuration upon request - Integrated flash protection (zone 2) (acc. to IP 54) CONTROL CABINET FOR ONE LED COMBINED OBSTRUCTION LIGHT AS-MI-LED CONTROL CABINET FOR TWO LED COMBINED OBSTRUCTION LIGHTS AS-MI-LED CONTROL CABINET FOR ONE LED OBSTRUCTION LIGHT AS-MI-LED CONTROL CABINET FOR TWO LED OBSTRUCTION LIGHTS AS-MI-LED - Size: 800 x 480 x 200 mm - Size: 800 x 480 x 200 mm - Size: 480 x 480 x 200 mm - Size: 480 x 480 x 200 mm - 1 x power supply 100-240 V, max. 20 A - 1 x AC driver combined operating electronics - 2 x power supply 100-240 V, max. 20 A - 2 x AC driver combined operating electronics - 1 x power supply 100-240 V, max. 20 A - 1 x AC driver operating electronics - 2 x power supply 100-240 V, max. 20 A - 2 x AC driver operating electronics Article number: 8333 4150 00 Article number: 8333 4125 00 Article number: 8333 4151 00 Article number: 8333 4152 00 10 11
C O M P O N E N T S O F C O N T R O L C A B I N E T S O P E R A T I N G E L E C T R O N I C S The control and monitoring unit AC-Basic links all devices connected to the system. It serves to control all lights. Additional AC systems can be extended to create a central communication network in a master / slave procedure. An integrated data logger stores the visibility measurements for at least four weeks. In case of an error potential-free alarm and warning message contacts are available to transmit the alarm message to the service staff or the operator. A connection to an existing guidance system in the building is possible without any problems. Thanks to the open structure it is possible to realise individual customer requests. The operating electronics is a part of the obstruction light system. For security reasons it is stored in the control cabinet separately from the light. This usually makes it more accessible. In case of failure of the control and monitoring unit AC-Basic or AC-Basic RC the light automatically switches to ICAO red/w-red (100 percent power, dimming deactivated). The basic diagnosis takes place via LED, the LED degradation is compensated. CENTRAL CONTROL AND MONITORING UNIT AC-BASIC INTERFACES - 4 X RS 485 for the connection of the obstruction lights (by means of the operating electronics) - Network connection (optional) - Visibility measuring device - Day / night sensor - GPS synchronisation - Warning message potential free - Error message: error of visibility measuring device / GPS failure (> 1 h) - 4 x status LED on circuit board, system message and diagnosis AC-LED COMBINED DRIVER - For AS-MI-LED and AS-MI-LED W-red (daylight / night light indication) Article number: 8333 4283 00 AC-LED DRIVER - For AS-MI-LED and AS-MI-LED W-red (night light indication) MULTICORE CABLE - Connection cable between obstruction light and operating electronics (control cabinet) incl. Harting plug-in connector (on the light side). CABLE FOR DAYLIGHT / NIGHT LIGHT INDICATION - 5 m Article number: 8333 4114 00-10 m Article number: 8333 4115 00-30 m Article number: 8333 4124 00 SUPPLY VOLTAGE - Supply 24 VDC, 0.3 A; Display on LED - Integrated supply for visibility gauge incl. heating OUTPUT AND DISPLAYS - Alarm output potential free - Error message: Day / night sensor of the obstruction light defective (> 24 h) / error obstruction light CENTRAL CONTROL AND MONITORING UNIT AC-BASIC RC The control and monitoring unit AC-Basic RC (radio controlled 869 MHz) is an extension of the standard monitoring unit AC-Basic. It contains all interfaces of the AC-Basic, the technical data correspond. As it offers data transmission by radio, cost intensive cables between the systems are dispensable. Article number: 8333 4294 00 CABLE FOR NIGHT LIGHT INDICATION - 5 m Article number: 8333 4340 00-10 m Article number: 8333 4341 00-30 m Article number: 8333 4343 00 Other cable lengths upon request. 12 13
E X T E N S I O N A C C E S S O R I E S S Y S T E M O V E R V I E W In addition to powerful obstruction and obstacle lights and their corresponding operation electronics aqua signal also offers a comprehensive range of accessories for extensions in its product portfolio. With peripheral units, for example a visibility measuring device, existing aviation security systems can be extended and complemented. LED Obstruction light COMBI-BOX DAY / NIGHT SENSOR - Cross-system GPS synchronisation - Light sensor to switch between daylight / night light indication in case of a defined ambient brightness - Protection degree IP 65 Article number: 8333 3029 00 UNINTERRUPTIBLE POWER SUPPLY (UPS) - External battery compartment for an uninterruptible power supply of the obstruction lights in case the main supply is interrupted - Size and time of emergency is defined according to customer s requests - Life time of battery at least 5 years - Includes potential-free signal contact when battery fails - Protection degree IP 67 Article number: on request VISIBILITY MEASURING DEVICE PWD 20 W VAISALA - Recognition of visibility and transmission to the connected control and monitoring unit AC-Basic or AC-Basic RC - Special parameter setting to regulate the light intensity of the connected hazard beacon at the levels 10, 30 and 100% - Includes heating to ensure optimal recognition of visibility even in temperatures below 0 ºC - Connection cable 35 m - Protection degree IP 66 Article number: 0002 1884 16 14 15