SMARTRIPPLE Geyser Load Control Timer

Similar documents
Installation Instructions

Grid Radar Installation Manual

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Sentry Digital Timers

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

OPERATING INSTRUCTIONS Digital weekly time switch

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

LK Wireless Room Control Cq

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

Aqua-Gen 3PV INSTRUCTIONS

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

C33R Repeater. User manual

SA-027HQ 365-Day Annual Timer

AT Advanced Wire Tracer. Users Manual

Short form User Manual

Aqua-Gen 3BR INSTRUCTIONS

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Broadband Step-Up Transformer. User Manual

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

INSTRUCTION MANUAL INF Fax: (503)

SUNDIAL Light Dimmer. User's Manual

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

LIGHTING CONTROL PANEL

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

3000W multi Pir light controller

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

Digital Electronic Thermostat With RF

ASSEMBLY AND INSTALLATION INSTRUCTIONS

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

3000W MULTI PIR LIGHT CONTROLLER

with Light Level, Isolated Relay and Manual On features

MaxLite Linear Strip ECO Series

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL WORKMANSHIP NQF LEVEL 3 NOVEMBER 2009

2011 / Circuit Tracer

Radio Control Installation and Operating Instructions System 4

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Quick Start Guide. PFD Six Meal Feeder. Please read this entire guide before beginning. For the full Product Manual, visit petsafe.com.

Wireless multizone receiver RDE-MZ6

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

Operating instructions Fail-safe delay timer AZS About this document. Content

Installation and Operating Instructions. Power IT Power Factor Controller RVC

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

AT-SL-DDR & AT-SL-DDR-SA

Mi Motion-Activated Night Light. User Manual

MST-5. Varifan USER S MANUAL MST-5 5 STAGE THERMOSTAT. computer compatible ADJUST. 9 reduc. per day 8 7 F rel. rel. rel. rel.

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

ANTENNA SpliTTEr. Zero loss active VHF antenna splitter. I N s t r u c t i o n m a n u a l

Fab King OWNER S MANUAL FOR RYE-Corp Model: RWC-02/ Fab King

PRO Professional Radio Control Series Applications

A Series Professional Power Amplifiers

WALL LANTERN ITEM # MODEL #LWS1204C ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

HIGH PERFORMANCE MARINE AUDIO HTX SERIES HTX-1, HTX-2, HTX-4, HTX-6 OWNER'S MANUAL. wetsounds.com

AT-SL-DDR & AT-SL-DDR-SA

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Installation Manual. This installation is for the Odyssey H1800 Series Ventilation System.

SYSTEM OPERATING CONTROLS

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

POWER TRACE TM TASCO, INC.

A Channel Amplifier

USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

EVERGREEN EM INSTALLATION GUIDE

GMINI 300PE AM/FM/Shortwave Radio OWNER S MANUAL

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

SYN-DX SERIES FULL RANGE CLASS-D AMPLIFIERS SYN-DX 2, SYN-DX 2.3 HP, SYN-DX 4, SYN-DX 6 OWNER'S MANUAL. wetsounds.com HIGH PERFORMANCE MARINE AUDIO

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

KeyPre KP6 - Electronic Instrument Preamplifier

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Guide. Installation. Wilson Electronics, Inc. Direct Connection High Power iden Amplifi er 800 MHz Band. Contents:

T L Audio INDIGO SERIES. User Manual VP-2051 VALVE VOICE PROCESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

Model: 5010 INSTALLATION AND OPERATING INSTRUCTIONS

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

IO-DIM4 4-Channel, Digital to Analogue Converters

INSTRUCTION MANUAL. March 11, 2003, Revision 3

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

ASSEMBLY AND INSTALLATION INSTRUCTIONS

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

SABRETrap Control. Description

Trap Series. Features: Description. Technologically Advanced: 2Km Range Protective Rubber Boot 1, 4 and 16 Switch versions

LED MIRROR CABINETS 3612-L-6560

Wireless Occupancy Sensor User Guide

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

Classic Series Public Address Amplifiers C10 & C20 Models

AT-SL-ADR & AT-SL-ADR/SA

JAMP-630HC14-ULP. Installation and Operation Instructions. ROKKER XXRP 630w Amplifier Kit For Harley Ultra/Ultra Ltd.

Transcription:

SMARTRIPPLE Geyser Load Control Timer Product description The ESCOTEK Geyser Load Control Timer, SmartRipple timer, will prevent hot water cylinders (geysers) from switching on during Eskom designated peak times in the mornings and evenings on weekdays. The SmartRipple permits the user to easily select one of five operating schedules by pressing the Bypass button to select the operating times. The SmartRipple is locally designed and manufactured according to ISO9001:2000 standards. The SmartRipple has a successful track record, having been successfully installed in the Eskom NMBM and Ekurhuleni load management programmes. The SmartRipple has many features including a one hour override/bypass option outside of ESKOM peak times, with a default random soft pickup value of 15 minutes. The soft pickup is settable via IR, and can be specified by Eskom. The SmartRipple is supplied with a shroud for installation next to the Distribution Board where necessary. The SmartRipple has a Letter of Authority (LOA) from NRCS. Functionality The SmartRipple is simple and quick to install, either within the Distribution Board or next to the Distribution Board with a separate Shroud, which is supplied for the unit. Five easily selectable pre-programmed operating schedules to ensure maximum comfort whilst not burdening the user with the complicated process of having to programme the unit. The 5 schedules options include: o Schedule 1 : Default, always ON, outside peak times o Schedule 2 : Solar, ON after hours to accommodate solar geysers o Schedule 3 : Holiday, OFF all the time, holiday function o Schedule 4 : Eco 1, ON 6 hours weekdays and 12 hours weekends. o Schedule 5 : Eco 2, ON 6 hours weekdays and 8 hours weekends. The SmartRipple disconnects power to the geyser during ESKOM designated peak times and has a 60 minute bypass option to permit the user to power ON for 60 minutes at any time outside peak times. The SmartRipple features a Eskom settable 15 minute random soft pickup time. The SmartRipple has a 3 year warranty, subject to the manufacturer s standard terms and conditions. The control unit is sealed to avoid tampering or accidental changes to the timing algorithm. The SmartRipple is supplied with a clear and easy to use installation and user guide. The SmartRipple features a battery backup with a minimum lifespan of 10 years, maximum 18 years. The SmartRipple utilises an onboard real time clock for minimal time drift of less than 65 seconds/ year. The SmartRipple has o Thermal protection on the terminals to prevent fires caused by loose connections. o Relay error indication. o Relay Bypass detection. o Input self resettable fuse protection. The SmartRipple key technical specifications:

o Supply voltage of 220-230 VAC, 50 Hz. o Maximum load switching capacity of 20A @ 220 230 VAC, 50 Hz. o Operating temperature range of -20 to +55 C. o Power consumption is smaller than 1W. o Width : 36 mm SAFETY PRECAUTIONS SPEC Safety precautions The installation of the SmartRipple must be done by a qualified electrician. Switch power off before installation. Make sure that the power wiring comes from a circuit with a maximum 20A circuit-breaker for shortcircuit protection. The unit is designed to be fitted in existing distribution boards using DIN, Mini Rails and surface mounting. Warning No person may do electrical installation work as an electrical contractor unless that person has been registered as an electrical contractor in terms of clause 6 of the Electrical Installations Regulation, Occupational Health and Safety Act, 1993 (Act No. 85 of 1993) Electrical connections must always be considered as energised irrespective of the LED indications. Specifications SAFETY PRECAUTIONS Input : 220-230VAC 50 Hz Current rating : 20A AC maximum Terminals : 4 mm² conductor, torque 0.5 Nm Power consumption : < 1W RTC Battery Back-up : Minimum lifespan of 10 years, maximum 18 years. RTC Drift : < 65 seconds/year Input protection : Thermal and 500 ma self resettable fuse. RTC and schedule programmable : Infra Red (IR), handheld or PC/USB Bypass/Override : Green LED flashing. Relay Status : Relay ON : Green LED on : Relay OFF : Red LED on Identification : Unique serial number. Programming : Infra Red (IR) interface, handheld or PC/USB Schedule : Flashing Blue LED : Schedule 1: Default : 1 flash : Schedule 2: Solar : 2 flashes : Schedule 3: Holiday : 3 flashes : Schedule 4: Eco 1 : 4 flashes : Schedule 5: Eco 2 : 5 flashes Mounting : DIN, Mini, Surface mount NRCS certification : Letter of Authority IEC : IEC 60669-1:1998, IEC 60669-2-2:2006 : IEC 60950-1:2001, SANS 60950-1:2003 Mounting location MOUNTING LOCATION The SmartRipple unit is designed to be mounted inside existing distribution boards using DIN, Mini Rails and surface mounted if distribution board mount is not possible. Alternatively, where there is inadequate space within the distribution board, the unit can be mounted next to the distribution board with the supplied DIN rail and shroud.

Surface mount - mounting location inside roof cavity (ceiling) close to the geyser isolator. The SmartRipple is to be fitted on a DIN Rail and attached to the wood rafters with screws. DIN, Mini Rail mounting mounting location inside existing electrical distribution board. INSTALLATION Note that it is the responsibility of the installer to ensure that the installation of this unit meets the minimum requirements to obtain the necessary Certificate of Compliance. Installation To facilitate the installation of the SmartRipple, the following tools/accessories are essential: Surface mount Electric/Cordless drill and drill bit; Phillips/Flat Screwdriver; Wood screws; Measuring tape; Permanent Marker. Din Rail mount inside distribution box Phillips/Flat Screwdriver. Select the proper mounting locations for mounting the SmartRipple as per section on mounting location. Wiring Figure 1

Led indications: normal conditions Blue LED : Flashing: indicating schedule Correct. : Any other state: Red LED: o o First check that the circuit breaker is ON. Contact the electricity supplier. OFF : Relay is OFF Correct. Green LED: ON : Relay is ON and there is an output voltage on the terminals Correct Flashing : Bypass function has been activated -Correct Red & Green LED: Flashing fast: Relay is OFF and in soft pickup mode. Usually after power failure - Correct Led indications: Fault conditions Red & Green LED : Both solid ON: Relay failure, switch circuit breaker off and contact the electricity supplier. Red LED : Flashing, Over Temperature. Faulty installation, switch circuit breaker off and contact the electricity supplier. Surface mount installation instructions 1. Turn OFF main circuit breaker inside master DB (inside house). 2. Turn OFF geyser isolator 3. SmartRipple surface mount installation; a. Select proper mounting location in ceiling cavity; b. Use DIN Rails supplied, demarcate mounting holes ; c. Mount DIN Rail, inside ceiling cavity with wood screws to wood rafters close to geyser isolator; d. Secure SmartRipple on DIN Rail. 4. SmartRipple Wiring Surface mount - Mains Power 220-240VAC ~50Hz; a. Mains live wire (RED) from Geyser Isolator to screw terminal (Figure 1 - Lin); b. Neutral wire (Black) from Geyser Isolator to screw terminal (Figure 1 - N). 5. SmartRipple Wiring Surface Mount - Timer Controller output to geyser; a. Live wire (RED) from geyser to screw terminal (Figure 1 - Lout); b. Neutral wire (Black) from geyser to screw terminal (Figure 1- N); 6. Ensure SmartRipple is installed correctly. 7. Turn on main circuit breaker, from master DB (inside house). 8. Select preferred schedule for operation. Distribution board installation instructions TALLATION/WIRING INSTRUCTION DIN RAIL DISTRIBUTION BOX MOUNT 1. Turn OFF main circuit breaker inside master DB (inside house). 2. Install SmartRipple; a. Select proper mounting location inside new or existing distribution panel; b. Secure SmartRipple on DIN Rail; 3. SmartRipple Wiring DB mount - Mains Power 220-240VAC ~50Hz; a. Mains live wire (RED) from geyser breaker to screw terminal Lin (Figure 1 - Lin); b. Neutral wire (Black/Blue) from Neutral Bar to screw terminal N (Figure 1 - N).

4. SmartRipple Wiring DB Mount - Timer Controller output to geyser; a. Live wire (RED) from geyser isolator to screw terminal Lout (Figure 1 - Lout); b. Neutral wire (Black) from geyser isolator to neutral bar (standard wiring); 5. Ensure SmartRipple is installed correctly. 7. Turn on main circuit breaker, from master DB (inside house). 8. Select preferred schedule for operation. Operation instructions N SmartRipple timer (Geyser) operation Ensure SmartRipple is installed correctly. Ensure all mains power connectors and covers are properly closed and secured. Ensure mains power is restored. Verify Mains power status, green LED light is ON. Verify Geyser status, red LED light OFF/ON. Verify SmartRipple Schedule status blue flashing LED. SmartRipple timer Schedule Selection Verify SmartRipple programme status blue flashing LED. Select preferred schedule. Change schedule by depressing Bypass Button with a single short (< 0,5 sec) press to move programme selection up one level, e.g., blue light flash once, single fast depress will move programme to level 2,blue light flashes twice etc. Continue schedule selection by depressing bypass button until correct schedule is obtained; o Schedule 1 Flashing Blue LED status light: 1 flash : Default, always in ON mode but OFF during designated peak times (Red) below (Weekdays). Bypass ON option may be selected at any time excluding designated peak times. o Schedule 2 Flashing Blue LED status light: 2 flashes: OFF from 08h00 to 15h00 and OFF for designated peak times (Red) below Weekdays) Bypass ON option may be selected at any time excluding designated peak times. This programme is suitable for solar geyser applications. o Schedule 3 Flashing Blue LED status light: 3 flashes: OFF all the time. Bypass ON option may be selected at any time excluding designated peak times (Red) below (Weekdays). This programme is suitable for solar geyser applications or when on holiday. o Schedule 4 Flashing Blue LED status light, 4 flashes : OFF from 00h00 to 03h00, from 08h00 to 15h00, from 20h00 to 24h00 and for designated peak times (Red) below (Weekdays). Note that Weekends there is an additional ON time from 11h00 to 13h00. Bypass ON option may be selected at any time excluding designated peak times. o Schedule 5 Flashing Blue LED status light, 5 : OFF from 00h00 to 03h00, from 08h00 to 15h00, from 20h00 to 24h00 and for designated peak times (Red) below (Weekdays). Bypass ON option may be selected at any time excluding designated peak times. SmartRipple Timer Bypass Function SmartRipple module is fitted with a 1 Hour Bypass function to allow geyser status control for the following: Manual user control, heating cold geyser for duration 1 hour. Depressing the bypass button (greater or equal to 1 second) on the SmartRipple will change Geyser Status to ON mode, normal thermostat control for the duration of 1 hour outside designated peak times. Notes The SmartRipple will power OFF the geyser before peak time and before profile OFF time by between 0 and 15 minutes, this time determined randomly, and will Power ON the geyser after peak time and after Profile ON by between 0 and 15 minutes, this time is determined randomly. Following a power outage, the SmartRipple will remain OFF for duration of maximum of 15 minutes soft pickup, this time is determined randomly. The default 15 minutes soft pickup can be adjusted by Eskom if required.

WARNING Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dump, hazardous substances can leak into the groundwater and get into the food chain, damage your health and well being. When replacing old appliances with new, the retailer is legally obligated to take back your old appliance for disposal free of charge. Escotek Contact Details Physical Address: 430 Muskejaat Street Waterkloof Ridge Pretoria, 0181, Gauteng, South Africa Postal Address: Post Net Suite 21 P/Bag X25723 Monument Park Pretoria, 0105, Gauteng, South Africa Telephone Number: +27 12-3477034 Fax Number: +27 12-3475352 Web page: www.escotek.co.za Email: marketing@escotek.co.za Warranty Escotek (Pty) Ltd ( ESCOTEK ) use quality components and skilled workmanship and are prepared to issue a Warranty in connection with the products that we produce. The terms of our Warranty include the replacement of any ESCOTEK manufactured product found to be effective insofar as such defect arising from the production process, and confirmed by ESCOTEK to have so occurred. The duration of the Warranty is for a period of a full 3 years from the date of purchase, but excludes the removal of any defective (or allegedly defective) product and/or the installation of replacement product or costs associated thereto. Standard commercial practice and insurance prescriptions dictate that excluded from our Warranty is any misuse, neglect, alteration to, lightning strikes (whether upon, above, beneath the ESCOTEK product or any receptacle housing the ESCOTEK product),sub-optimal installation or physical damage to our products arising from any cause whatsoever. Reference guide NCE GUIDE This SmartRipple allows the user to select one of five operating programmes as illustrated below. Each programme provides different electrical power ON times to the geyser. Note, during the electrical power ON times the geyser will only switch on and heat water when required to do so by the geyser thermostat. The user may select the Bypass ON option to power ON the geyser for up to 60 minutes to heat water as required. Note; this option is NOT available during designated peak times. The SmartRipple has been pre-programmed to switch off electrical supply to the geyser during the designated peak times, Weekdays 06H00 to 08H00 and 18H00 to 20H00. The user may not override or alter these peak times. Schedule Selection Select required programme by pressing Bypass button with a single one second press to move schedule selection up one level, blue LED flashes once, single press will move schedule to level 2, blue light flashes twice etc, until the correct schedule is obtained.

Schedule 1 (Default) Blue LED flash : 1 flash ON : Weekdays - outside peak times, Weekends always ON. OFF : Weekdays - peak times. Bypass : not applicable. Schedule 2 (Solar) Blue LED flash : 2 flashes ON : outside peak times (morning and evening Monday to Friday). OFF : peak times. Bypass : option may be selected at any time excluding designated peak times. Schedule 3 (Holiday/On demand) Blue LED flash : 3 flashes ON : outside peak times (morning and evening Monday to Friday). OFF : peak times. Bypass : option may be selected at any time excluding designated peak times.

Schedule 4 (Eco 1 ) Blue LED flash : 4 flashes ON : outside peak times (morning and evening Monday to Friday). OFF : peak times. Bypass : option may be selected at any time excluding designated peak times. Schedule 5 (Eco 2) Blue LED flash : 5 flashes ON : outside peak times (morning and evening Monday to Friday). OFF : peak times. Bypass : option may be selected at any time excluding designated peak times. End