Light Emitting Diode Illuminators for Video Microscopy and Machine Vision Applications

Similar documents
Vixar High Power Array Technology

Vision Lighting Seminar

H22: Lamps and Colour

Reducing Energy Demand Using Solid-state Lighting. Presented by: Ray Kendall, P.E May 6, 2009

Improving the Collection Efficiency of Raman Scattering

Basic Function. Indoor environment

Electrical and Optical Characteristics

FAQ on the X-CITE 120 System

Light, Color, Spectra 05/30/2006. Lecture 17 1

Where brightness and quality are essential for you Specialty light sources for medical and industrial applications

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

the physics of different light sources incandescence and blackbody radiation the concept of photons

Infra-Red Propagation Through Various Waveguide Inner Surface Geometries

Optimizing throughput with Machine Vision Lighting. Whitepaper

Eight Tips for Optimal Machine Vision Lighting

SPECTRAL IRRADIANCE DATA

Coaxial Lights LFV3 series

Advantages of LED Lighting in Vision Inspection Systems

Chapter 3 OPTICAL SOURCES AND DETECTORS

Video Microscopy of Selective Laser Sintering. Abstract

LumiBright TM LE 2400B-270

From the start the main activity of our company was the development and production of infrared illuminators.

Microscopic Structures

PRODUCT DATA SHEET FEATURES

PLCC-2 Pkg Infrared Light Emitting Diode

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Novel Approach for LED Luminous Intensity Measurement

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

UV COBRA Slim Supplementary information

Techniques for Suppressing Adverse Lighting to Improve Vision System Success. Nelson Bridwell Senior Vision Engineer Machine Vision Engineering LLC

Lighting Terminologies Introduction

Typical LED Characteristics

Where Image Quality Begins

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS Cambridge International Level 3 Pre-U Certificate Principal Subject

LFV3-100SW LFV3-40SW. Transmittance rate (High) LED side. Move to LED side. LED side. Default position LFV3-CP-13RD. Wavelength/ color.

Optical Systems. in Image Processing

PRODUCTION DATA SHEET

ECEN 4606, UNDERGRADUATE OPTICS LAB

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

Pinch-the-Sky Dome: Freehand Multi-Point Interactions with Immersive Omni-Directional Data

White Paper - Photosensors

Ultraviolet Visible Infrared Instrumentation

Proximity Sensor SFH 7741 Application note

LuxiGen Platform ENTERTAINMENT LIGHTING ARCHITECTURAL LIGHTING HIGH-END INTERIOR SPACES UV CURING INFRARED ILLUMINATION HORTICULTURE & SPECIALTY

Application Note (A16)

Detailed Scientific Barrier Filter Discussion

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

LAB 11 Color and Light

Ambient Light Sensors General Application Note

CHAPTER VII ELECTRIC LIGHTING

Compact High Intensity Light Source

Table 8 Overview light sources

DIGITAL PHOTOGRAPHY FOR OBJECT DOCUMENTATION GOOD, BETTER, BEST

Components of Optical Instruments

Home-made Infrared Goggles & Lighting Filters. James Robb

Non-optically Combined Multi-spectral Source for IR, Visible, and Laser Testing

Radiometric and Photometric Measurements with TAOS PhotoSensors

WFC3 TV2 Testing: UVIS Filtered Throughput

BRIDGELUX BLUE POWER DIE BXCD 45 x 45

Considerations When Transitioning from Lamp-based to LED-based Radiant Flux Sources

Measuring the Light Output (Power) of UVC LEDs. Biofouling Control Using UVC LEDs

Wide-field Infrared Survey Explorer (WISE)

CAMTO. Arc detecting relay. system. January Revised August D D1200

AvaLight-DHc Full-range Compact Light Source

Custom Alphalight. Tailored for your specifi c application. ALPHALIGHT LED Illuminators

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

GUIDE TO SELECTING HYPERSPECTRAL INSTRUMENTS

Dome Packages The HLMX-QXXX dome lamps use an untinted, nondiffused lens to provide a high luminous intensity within a narrow radiation pattern.

White Light Emitting Diodes. Erick J. Michel Energy Law Spring 2009 Professor Bosselman

KL Series. Fiber optic illumination for stereo microscopy

How interference filters can outperform colored glass filters in automated vision applications

Efficient Lighting in. Medical Technology

MetaBright Diffused Tube Lights MB-DT

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Radium presents: The Radium LED programme

Luxeon V Portable. power light source. Technical Data DS40

NSOM (SNOM) Overview

Optical design of a high resolution vision lens

Optics B. Science Olympiad North Regional Tournament at the University of Florida DO NOT WRITE ON THIS BOOKLET. THIS IS AN TEST SET.

3mm 5mm (T1) ¾) Package Discrete LED AMBER, YELLOW, Super Bright B

CHAPTER-2. Application of Video Spectral Comparator for Examination of Printed Material

Preventive Conservation and Energy conservation. Units of light, Perception of colour, Energy used by lighting.

StarBright XLT Optical Coatings

THE CANDELA - UNIT OF LUMINOUS INTENSITY

SER: Biological Stains Visualization with Alternate Light Sources

(PT-3528) Chip Ambient Light Sensor, RoHS Compliant. Token Electronics Industry Co., Ltd. Version: July 26, Web:

ABSTRACT INTRODUCTION METHOD

Application Notes Photoconductive Cells

Flat-white LED. Neutral White Light-emitting Diode EWL5FW12. Key Features. Typical Applications. Principal Parameters. Absolute Maximum Ratings

ROAD TO THE BEST ALPR IMAGES

Recommendations for Testing and Evaluating Under-cabinet Luminaires

Optical Fibers for Improved Low Loss Coupling of Optical Components

High Intensity LumiBright LE LED Light Engine

BRIDGELUX BLUE POWER DIE BXDA 40 mil x 40 mil

CBT-39-UV LEDs. CBT-39-UV CBT-120 Product Datasheet. Features: Table of Contents. Applications

CHAPTER 7. Components of Optical Instruments

External Optical Probes. EOP-xxx and ISP 40. Two Global Leaders. One Complete Solution.

(12) United States Patent (10) Patent No.: US 6,388,807 B1. Knebel et al. (45) Date of Patent: May 14, 2002

Motorized Axio Observer Start-up instructions

Transcription:

Light Emitting Diode Illuminators for Video Microscopy and Machine Vision Applications By Dr. Dmitry Gorelik, Director of Research and Development, Navitar, Inc. Illumination system as the part of an imaging system Illumination is one of the most important issues in machine vision. Most imaging systems usually include an optical system, system, camera censor and data analyzing system. Any of these systems can be a bottleneck in the imaging process. The best diffraction limited optical system will not supply good image quality without the correct. The system can either enhance or diminish some features of a monitored object. Furthermore, poor can even create artifacts. Fortunately, many of these problems can be avoided with the correct lighting. When considering for an imaging system, the numerical aperture of the optical system, camera sensitivity, light spectrum, light intensity and angular distribution are the key parameters to keep in mind. Fiber optics system concepts Let s consider one of the best system concepts, the diffused day skylight. In this system, the object of interest is illuminated from many angles at the upper half of the sphere. This is the most appropriate system for the human eye because it illuminates microscopic objects in a way that is very similar to the day light that we are used to for macroscopic objects. An attempt to duplicate the range of angles of the day skylight is the simultaneous use of multiple fiber optic illuminators, including a ring light, coaxial illuminator and double bundles (Fig. 1). Unfortunately, the discrete character of is the weak point for almost any fiber optic system. For example, the fiber optic system described above has very large angular halls between every single unit (Fig. 1).

Figure 1 Camera Optical system Fiber optic ring light Coaxial fiber optic Fiber optic bundles Figure 1: Schematic diagram of the typical fiber optic system for video zoom microscopy. Red lines show the angular halls in this system. There are many approaches that attempt to reach day skylight using fiber optic techniques. One example is the Fostec and Lumitex produced Front-light (or panel light) illuminator (Fig. 2). This illuminator covers the entire range of angles from approximately 5 degrees up to 25 degrees to the normal. This approach dramatically increases the image quality of some machine vision applications and appears to be very successful. However, even with Front-light, the system has a significant amount of angular halls. Other weak points of this system are the low brightness of the Front-light unit and very bad mechanical stability of the plastic fibers.

Figure 2 Camera Optical system Coaxial fiber optic Front-light fiber optic Fiber optic bundles Figure 2: Schematic diagram of the typical front panel fiber optic system for video zoom microscopy. Red lines show the angular halls in this system. Another very popular approach is the fiber optic Diffused Dome type illuminator. In this type of illuminator the optical fiber ring light is placed at the bottom part of the hemisphere. The light is diffusively reflected from the dome walls and completely covers all angles of the hemisphere. The weak points of this system are not only intensity, which is usually insufficient for microscopic applications with less than a 2mm field of view, but also the inability to change the angular distribution of light intensity. Uniform light angular distribution is not always the best for non-diffusive objects.

Model of the ultimate system The ultimate, most versatile system is the Dome type (or hemispherical) LED system with the ability to change the light intensity from any immeasurably small area in the hemisphere (Fig. 3). To better visualize this type of system, imagine that the night sky, completely filled with stars, is the dome type LED system and you have the ability to change the intensity of any star in the sky. In the actual system, instead of a night sky filled with stars, you have a dome filled with LEDs. Each LED can be adjusted to change the light intensity to get the best possible. Figure 3 Camera Optical system Dome type LED Coaxial LED Illumination Single LED light source Figure 3: Schematic diagram of the dome type LED system for video zoom microscopy. Red lines show the angular halls in this system.

The dome type LED system works very well for reflective, diffusive, flat and rough objects. Any problem can be solved using this ideal system. However, to properly operate such a complicated system, you must know how to set the intensity and angular of the each LED. The angular, which can be time modulated, allows the system to receive important three-dimensional information about the object. The building of such an system from conventional light sources and fiber optic illuminators is completely impractical for several reasons: the relative large size of conventional light sources, heat dissipation problems, and the very high cost of fiber optic illuminator systems. It is, however, relatively easy to achieve this ultimate system by using LEDs as the light source. LEDs have the unique ability to be building blocks in the ultimate system because of their small size and relatively low heat dissipation. I would like to emphasize that the main appeal of LED is how easily it fits into the model of the ultimate system. Small single LEDs, like stars in the sky, perform excellently for any very complicated problem.

Comparison of LED and conventional light sources a. Spectrum The spectrum of a conventional quartz halogen light source is very similar to black body radiation (Fig.4). The effectiveness of the quartz halogen lamps is low and further reduced by an additional 50% with fiber optic coupling. Figure 4 Spectrum of the Quartz halogen light source with IR cut filter 1 0.9 0.8 Relative intensity 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 300 400 500 600 700 800 900 1000 1100 1200 Wavelength (nm) Figure 4: Typical spectrum of the Quartz halogen light source with infrared cut filter. LEDs are solid-state semiconductor devices that convert electrical energy directly into light. The light generation efficacy is very high because most of the energy radiates within the visible spectrum (Fig. 5, Table 1).

Figure 5 Nichia White LED spectrum 1 0.9 0.8 relative intensity 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 350 400 450 500 550 600 650 700 750 800 Wavelength (nm) Figure 5: Typical spectrum of the white Nichia LED. Table 1 Quartz halogen Tungsten lamp Fluorescent Lamps Super Bright LED 15 Lumen/watt 70 Lumen/watt 60-80 Lumen/watt Table 1: Summarizing the light efficacy of the major light sources: In addition to low efficacy, the light output of the QH lamps is very much in infrared and red portions of the spectrum. The combination of the red QH-light source from the machine vision system and the white-blue light from the ambient fluorescent light makes it impossible to properly adjust the white balance of the sensitive camera. The combination of white LEDs and fluorescent light has very good match.

b. Lifetime The lifetime of some QH lamps does not exceed 40 hours. This can be very problematic for machine vision applications. For example, the machine will need to be shut down to replace the bulb an average of every two days. The lamp can also die in the middle of the operation process, making it necessary to stop the machine, change the bulb and recalibrate the machine before restarting it again. Reliability is the most important feature of the LED. The expected lifetime for each LED is around 100,000 hours. This equals nearly 11 years of continuous operation. However, it is important to consider the thermal condition of the LED operation, which does change over the lifetime of the light. Under normal operation conditions (25 degrees C and 20mA) the light output drops off 2% for every 1000 hours of operation. The results are much less promising for white LEDs where the light LED intensity drops off 10% for every 1000 hours of operation. It is possible to reduce the percentage drop off per 1000 hours to a very small amount by operating at reduced power settings. c. Mechanical Stability LEDs are mechanically very stable. If you look at an LED bulb closely you will see that there are some wires and a little block of material completely encapsulated in clear plastic. It is almost impossible for the LED bulb to fail because of mechanical damage unless the plastic is smashed with a hammer. The mechanical stability of the LED unit makes it the preferred choice for applications where lighting is attached to moving parts. Fiber optics, on the other hand, is not as mechanically stable as LEDs and can break over time, reducing intensity.