CP CU1. Coupling unit for line and ground testing

Similar documents
Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

CT Analyzer. Revolution in current transformer testing and calibration

CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

CPC 100. Multi-functional Primary Test System for Substation Commissioning and Maintenance

World Leader in Innovative Power System Testing Solutions

CT Analyzer. Current transformer testing, calibration and assessment

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

Diagnostic testing of cast resin transformers

TESTRANO 600 ordering information

CP CU1. Reference Manual COUPLING UNIT FOR LINE IMPEDANCE AND K FACTOR MEASUREMENTS, COUPLING MEASUREMENTS ON POWER LINES AND SIGNAL CABLES AND

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

TESTRANO 600. Three-phase test system for comprehensive power transformer testing

TESTRANO 600. Three-phase test system for comprehensive power and distribution transformer testing

Primary Test Manager (PTM) Testing and management software for primary assets

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Advanced Test Equipment Rentals ATEC (2832)

CP CU1. Reference Manual

N. TEST TEST DESCRIPTION

VOTANO 100. Accurate and mobile voltage transformer testing and calibration system

Specialists in HV and MV test and diagnostics. Testing in Substations

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

MONTRANO. Continuous monitoring system for power transformers

TRAX Transformer and Substation Test System

Advanced Test Equipment Rentals ATEC (2832)

OMICRON Academy Hong Kong. Excellence through Education

N. TEST TEST DESCRIPTION

MPD 500. Partial Discharge Measuring System for Routine Test Applications

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

CIBANO in-1 test system for medium- and high-voltage circuit breakers

Why partial discharge testing makes good sense

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

MEDIUM & HIGH VOLTAGE

Automatic Transformer Winding Analyser

OFFER OF SERVICE / Cité 1200 Logts, Coopérative Granitex Bt. 05, N 01-Bab Ezzouar Alger Algerie

FRAnalyzer. Reliable core and winding diagnosis for power transformers

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

S T S MULTIFUNCTION SUBSTATION MAINTENANCE & COMMISSIONING TEST SYSTEM FOR CURRENT, VOLTAGE AND POWER TRANSFORMERS THE OPTIONAL MODULE TD 5000

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

A New Technology. for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations. Feature

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

Electrical Description

Končar TMS - Bushing monitoring

Tan Delta test on rotative machines (generators and motors) Fully automatic

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

FRAX Series Sweep Frequency Response Analyzers

RAPTOR Step and Touch Function

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Substation Testing and Commissioning: Power Transformer Through Fault Test

Hamdy Faramawy Senior Application Specialist ABB Sweden

True Three-Phase Transformer Turns Ratio Tester TRT400

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security

ELECTRICAL POWER ENGINEERING

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Back to the Basics Current Transformer (CT) Testing

3. COMBINED TRANSFORMERS Oil-paper insulation

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

CMC 256plus - protection relay test set and universal calibrator

How to maximize reliability using an alternative distribution system for critical loads

Protection of Electrical Networks. Christophe Prévé

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Three-Phase Winding Ohmmeter TWA25K

Fully automated three phase 250V Transformer Turns Ratio Meter

Electrical Measurement Safety. Sponsored By:

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

ACCURACY OF VOLTAGE TRANSFORMERS DESIGN CRITERIA AND A SURVEY ON THE PRECISION AND REPRODUCIBILITY OF A NEW MODEL-BASED CALIBRATION APPROACH

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Impact Assessment Generator Form

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

VI 3 - i TABLE OF CONTENTS

6135A/PMUCAL Phasor Measurement Unit Calibration System

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Maintenance & Diagnosis Strategies. for. High Voltage Substations

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CONTENTS. 1. Introduction Generating Stations 9 40

Current / residual current and voltage transformers. Current / residual current and voltage transformers

ABSTRACT 1 INTRODUCTION

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Catastrophic Relay Misoperations and Successful Relay Operation

ODEN AT Primary Current Injection Test System

Insulation Testers and Earth Ground Testers

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION

Alternative Testing Techniques for Current Transformers. Dinesh Chhajer, PE Technical Support Group MEGGER

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

Sensor Technology. Applications for medium voltage

Transcription:

CP CU1 Coupling unit for line and ground testing

Line and ground test system CPC 100 The CPC 100 is a multifunctional test set for primary assets. When combined with the CP CU1 it covers the following tests: > > Line impedances of overhead lines and power cables for distance relay parameterization > > Mutual coupling impedances between parallel lines > > Ground impedances of large substations (fall-of-potential or 3-point test) > > Step and touch voltages > > Reduction factor > > Coupling of power lines into signal cables CPC 100 HGT1 Handheld grounding tester CP GB1 Grounding box 2

+ CP CU1 Safe testing Measurements on power lines require special safety precautions. The CP CU1 ensures the galvanic isolation of the user from the line under test for enhanced protection. In addition the CP GB1 features high current surge arrestors to protect the CP CU1 and the CPC 100 from unexpected overvoltages on the line under test. Up to 30 ka can be safely diverted to ground. Accurate and light-weight Overhead lines can be subjected to high interference. Accurate line impedance measurements therefore require effective noise suppression. For this reason the CPC 100 employs frequency selective measurement. This means that a test current with a frequency different from power frequency is injected into the line. Using a digital filter for the current and voltage measurements allows power frequency interference to be suppressed effectively and the test parameters to be determined accurately. V digital filter 30 Hz 50 Hz interference injection Conventional testing equipment uses noise suppression methods which require much higher test currents. Thus the equipment is much larger and heavier. The heaviest component of our test solution is 29 kg / 64 lbs perfect for easy handling and for being shipped around the world! f CP CU1 Coupling unit Your benefits > > High Accuracy: Frequency selective measurement and digital filtering > > Safety: Galvanic isolation and protection from overvoltages > > Light-weight and easy to handle > > Intuitive reporting and assessment with dedicated templates > > One unit for line and ground testing www.omicronenergy.com/cpcu1 3

Line impedance measurement Line parameters for distance protection X in Ω Correct line parameters are crucial for reliable and selective distance protection. The set of parameters contains the positive and the zero sequence impedance (Z 1, Z 0 ) as well as the k-factor (k L, R E /R L and X E /X L, k 0 ). These parameters are often calculated from software tools, which do not provide actual line parameters due to unknown soil properties, such as different soil resistivities, pipelines or other unknown conductors. This leads to under- or overreach of your distance protection relay resulting in outage and loss of grid stability. Zone under- and overreach Zone 2, t 2 = 300 ms Zone 1, t 1 = 0 ms Line impedance Z L Phase-to-ground Fault: Calculated impedance 100 % of Line length The most frequent faults on power lines are ground faults. In particular, inaccuracies from software calculation effect this kind of fault. The example on the right shows a zone overreach for a ground fault due to an incorrect k-factor setting. In this case the assumed k-factor is higher than the actual one. Therefore, a ground fault at the remote end of the line is seen incorrectly in the first zone. Incorrect k-factor (tendancy to overreach) R in Ω Measurement advantages: > > Tune your distance relay by performing a line impedance measurement > > Safe and quick determination of Z 1, Z 0 and k-factors. > > Mutual coupling Impedance measurement between parallel lines 4

Test set-up The test set-up for a line impedance measurement is shown below. The loops A-B, B-C and A-C are measured to determine Z 1. The loop ABC-G is measured to determine Z 0. K-factor formats commonly used in distance relays are then calculated from these two values. Testing with the CPC 100 The main unit CPC 100 unit generates the frequency variable test current and measures current and voltage by applying digital filtering for high accuracy. The complex loop impedance is then calculated accordingly. The CP CU1 provides galvanic isolation between the line under test and the CPC 100 as well as impedance matching for short and long lines. The CP GB1 protects the test equipment and the user from any unexpected overvoltage on the line under test. Furthermore it allows a direct connection to the power line for a convenient execution of the test. A dedicated test template provides the positive and the zero sequence impedance as well as the k-factor in commonly used formats. Furthermore it shows the actual zone reach for each fault type based on the measured values and relay parameters that are currently being used. Mutual coupling With this unique testing equipment, the mutual coupling impedance between parallel lines can also be determined to consider coupling effects for correct parameterization. A B C Ground grid Safe area 5 High-voltage area

Grounding system testing Personnel safety In the event of a ground fault hazardous step and touch voltage can occur inside and outside of a substation. Ground tests prove the effectiveness of grounding systems and guarantee safety of people inside and outside the substation. A fall-of-potential measurement is usually performed to determine the condition of the entire ground grid. On top of that, step and touch voltages are measured at exposed locations in order to ensure human safety. * Ground Impedance measurement (3-point test) * For the fall-of-potential measurement according to EN 50522 and IEEE 81 the voltage between the ground grid and ground electrodes in different distances to the ground grid is measured until reference ground is reached. PTM instantly transforms the test results into a voltage and impedance chart which allows the ground potential rise and the ground impedance to be determined. 90 Test Current Injection When testing large ground grids the potential of the ground grid under test and the counter electrode must not overlap. This is done in order to ensure human safety in a worst case scenario, which is always crucial. The CPC 100 + CP CU1 overcomes this problem by injecting the test current into a remote substation via an existing power line. 6

Step and touch voltage measurement Step and Touch voltage measurements according to EN 50522 or IEEE 81 are performed at locations inside and outside the substation. PTM automatically assesses the measurements according to EN 50522 or IEEE 80. Tests can be executed quickly and easily since long test cables for connecting to the main device are no longer necessary. Measurement advantages: > > Determine true test values by power line injection > > Ground Impedance and Step and Touch voltage Testing with PTM and HGT1 > > Automated GPS Tracking > > Offline Usage of BING maps > > Charts and Final results instantly available > > Real time assessmentreduction factor measurement on ground wires and cable shields Voltage measurement Primary Test Manager (PTM) and HGT1 enable you to quickly, simply and conveniently measure ground impedance as well as step and touch voltage. Due to a new approach there is no operational personal required at the CPC 100 anymore. Together, the test director and assistants perform all measurements out in the field in order to avoid miscommunication and selection of inadequate test points. 7

Software supported testing Test templates We provides dedicated Microsoft Excel test templates for line and ground testing. This allows reporting and test data assessments to be performed quickly and easily. Line impedance The line impedance test template shows the actual zone reach of an arbitrary parameter set (X-value of the zone and k-factor) based on the measured impedances. The example on the left refers to the settings of the first zone (usually 80 % zone reach) which reveals a zone underreach for ground faults. Ground testing Primary Test Manager (PTM) in combination with the HGT1 supports fully automated ground impedance as well as step and touch voltage measurements. Both tests feature GPS and offline usage of BING maps for convenient tracking of test points. PTM instantly creates impedance and voltage charts and calculates step and touch voltages with respect to maximum single line to ground fault currents. This allows real time assessment according to EN 50522 and IEEE 80. System-based protection testing with RelaySimTest RelaySimTest is our easy-to-use software for system-based protection testing with CMC test sets. It applies power system simulations based on the measured line, ground and mutual coupling impedances and calculates realistic voltages and currents for multiple fault scenarios automatically. This unique approach reveals failures created during calculations used for the parameterization of protection relays as well as during the setup of a relay or a complete protection scheme. 8

CPC 100: the all-in-one system The CPC 100 covers a lot of other applications in and around substations as well as at the manufacturer s production site. This powerful device provides up to 800 A or 2 kv with up to 5 kva over a frequency range of 15 Hz to 400 Hz or 400 A DC. It can test various substation assets, thereby replacing several individual testing devices. This makes testing with the CPC 100 a time-saving and cost-effective alternative, especially as the application range of the CPC 100 is further expanded by a high number of valuable accessories. Despite its expansive capabilities, the CPC 100 is very simple to use. Thus it is the ideal instrument for all major applications in the area of substation asset testing. Featured assets > > Current transformers > > Voltage transformers > > Power transformers > > Power lines > > High-voltage cables > > Grounding systems > > Rotating machines > > Switchgear and circuit breakers > > IEC 61850 installations > > Protection relays Ground resistance meter Micro ohmmeter 400 A DC Turns ratio meter for transformers, CTs and VTs High-current injection transformer 29 kg / 64 lbs single phase wall outlet Tester for Rogowski coils and other unconventional CTs / VTs (IEC 61850) Winding resistance meter Power meter (P, Q, S) Protection relay tester (one phase V, I, f) Excitation curve tester 2 kv 400 A DC Multimeter (V, I, R, Z,...) 12 kv (with booster) 800 A AC 2 ka (with booster) Phase angle meter Step up transformer 2000 V Line impedance and cable measurement 15 Hz - 400 Hz Complex impedance meter (burdens, cables, lines and transformers) On load tap changer test equipment Polarity checker Power / dissipation factor measurement set Vector group verification system for power transformers 9

Technical data CPC 100 * Power specifications Single-phase, nominal 1 Single-phase, permissible Frequency, nominal Mechanical data Dimensions (W H D) (cover without handles) Weight (case without protection cover) CP GB1 100 V AC... 240 V AC, 16 A 85 V AC... 264 V AC (L-N or L-L) 50 Hz / 60 Hz 468 394 233 mm / 18.4 15.5 9.2 in 29 kg / 64 lbs CP CU1 Output ranges Range Current Compliance voltage at > 45 Hz 10 A 0... 10 A rms 500 V rms 20 A 0... 20 A rms 250 V rms 50 A 0... 50 A rms 100 V rms 100 A 0... 100 A rms 50 V rms Measuring transformers Transformer Ratio Accuracy at 50 Hz / 60 Hz VT 600 V : 30 V Class 0.1 CT 100 A : 2.5 A Class 0.1 Inputs Nominal ac spark-over voltage Impulse spark-over voltage < 1 000 V rms < 2 000 V peak V SENSE Characteristic Rating Overvoltage category CAT III (IEC 61010-1) Short circuit proof with: 16 mm cylindrical or 20 mm ball studs 26.5 ka (< 100 ms) / 67 ka peak 25 mm ball studs 30 ka (< 100 ms) / 75 ka peak Torsional moment for changing arrestors Dimensions (Ø H) Weight > 15 Nm 200 190 mm / 7.9 7.5 in 6.8 kg / 13.2 lbs (including grounding cable) BOOSTER Output power Voltage range Overvoltage category Voltage range Current range Frequency range Fuse 0... 600 V rms CAT I 0... 200 V rms 0... 30 A rms 15 Hz... 400 Hz 30 A fast acting, automatic circuit breaker HGT1 Voltage input Power supply Max. 25 V rms 1 3.7 V lithium polymer (Li-Po) battery Dimensions (W H D) 90 180 45 mm / 3.5 7.1 1.8 in Weight (including battery) 0.48 kg / 1 lb Characteristic Maximum power Continuous power Accuracy Range Rating 5 000 VA (45 Hz... 70 Hz), cos φ < 1.0 for 8 s at 230 V AC 5 000 VA (45 Hz... 70 Hz), cos φ < 0.4 for 8 s at 115 V AC 0... 1 600 VA Accuracy of absolute value Accuracy of phase angle V SENSE voltage I OUT current Current range 0.05... 0.2 Ω 1.0... 0.5 % 1.5... 0.8 5... 20 V 100 A 100 A 0.2... 2 Ω 0.5... 0.3 % 0.8... 0.5 20... 50 V 100... 25 A 100 A 2.0... 5 Ω 0.3 % 0.5 100 V 50... 20 A 50 A 5.0... 25 Ω 0.3 % 0.5 100... 250 V 20... 10 A 20 A 25... 300 Ω 0.3... 1.0 % 0.5... 1.5 250... 500 V 10... 1,5 A 10 A Mechanical data * Additional information can be found in the CPC 100 brochure. Dimensions (W H D) Weight 450 220 220 mm / 17.7 8.7 8.7 in 28.5 kg / 62.78 lbs 10

Ordering information CP CU1 Packages Package Description Ordering No. CP CU1 and CP GB1 Upgrade Option CPC 100 Line Impedance Test System Upgrade opiton to expand your existing CPC 100 to a line impedance measurent test system. Note: CP sequencer test card has to be ordered separately (order no. VESM0635) Package including CPC 100, CP CU1, CP GB1 and all accessories to perform impedance measurements for determination of distance protection relay settings. VEHZ0671 VE000602 Step & Touch Voltage Set for CP CU1 Package to measure step and touch voltages within HV stations and surrounding areas. Including handheld grounding tester HGT1 and accessories. VEHZ0625 Ground Impedance Set for CP CU1 Upgrade option for ground impedance measurements. It comes with Rogowski coil and a handheld etrex 10 GPS navigation device including accessories. VEHZ0622 CPC 100 Line impedance test system (order no. VE000602) 11

OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the product range complete. Customers in more than 140 countries rely on the company s ability to supply leadingedge technology of excellent quality. Service centers on all continents provide a broad base of knowledge and extraordinary customer support. All of this together with our strong network of sales partners is what has made our company a market leader in the electrical power industry. The following publications provide further information on the solutions described in this brochure: CPC 100 Multi-functional primary test system for substation commissioning and maintenance RelaySimTest Software for system-based protection testing CPC 100 Brochure RelaySimTest Brochure For more information, additional literature, and detailed contact information of our worldwide offices please visit our website. www.omicronenergy.com OMICRON L2786, November 2017 Subject to change without notice.