Parallel Prototyping and the Engineer s Dilemma

Similar documents
Improve the Ergonomic Experience with Pressure Mapping

Phase 2 Executive Summary: Pre-Project Review of AECL s Advanced CANDU Reactor ACR

Model Based Design Of Medical Devices

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

WDBR Series (RoHS compliant)

Test, Validation and Regulatory Requirements for Medical Electronics

Leading Design and Contract Manufacturer to the Medical Technology Industry. Med-tech Pharmaceutical Diagnostics.

XPERION COMPONENTS CFRP THE MATERIAL FOR YOUR INNOVATIONS FOR INNOVATORS. FOR PATHFINDERS. FOR YOU.

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

Additive Manufacturing: A New Frontier for Simulation

50W TO220 High Power Resistors

Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

The MSW2T /-197 Switch Module carries a Class 1 ESD rating (HBM) and an MSL 1 moisture rating.

Arshad Mansoor, Sr. Vice President, Research & Development INNOVATION SCOUTS: EXPANDING EPRI S TECHNOLOGY INNOVATION NETWORK

INTRODUCTION TO FIXED LIMIT GAGING (Back to Contents)

The Influence of a Belt Furnace on the Brazing Process

OmniCure Setting the Standard for Precision Assembly UV Bonding

RF & Microwave Power Amplifiers

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

LedEngin, Inc. High Luminous Efficacy Cool White LED Emitter LZC-00CW40. Key Features. Typical Applications. Description

Leveraging Med Device Expertise to Develop Combination Products

High Efficacy 365nm UV LED Emitter LZ1-00U600

WHY TAKE CHANCES WITH ANY OTHER COOLER?

Technical Note 1 Recommended Soldering Techniques

LedEngin, Inc. High Efficacy 365nm UV LED Emitter LZ1-00U605. Key Features. Typical Applications. Description

LIGHT TO THE LIMIT. Image brochure

L100 The ultimate CMM laser scanner combining productivity and accuracy NIKON METROLOGY I VISION BEYOND PRECISION

What We Heard Report Inspection Modernization: The Case for Change Consultation from June 1 to July 31, 2012

National Medical Device Evaluation System: CDRH s Vision, Challenges, and Needs

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Preliminary. LedEngin, Inc. High Radiant Flux Density 400nm Violet LED Emitter LZP-00UA00. Key Features. Typical Applications.

High Efficacy UV LED Emitter LZ4-00UA00

emblation microwave INDUSTRIAL, SCIENTIFIC AND MEDICAL

Surface Mount Limiter, GHz

High Luminous Flux Density Warm White LED Emitter LZC-00WW00

WDBR Series Application Note. Resistors. BI Technologies IRC Welwyn

C O M F O R T F O R L A R G E S P A C E S. R a d i a n t h e a t i n g

Medical Device Usability Engineering. Product and Service Design Innovation Consultancy

Advanced, accurate and intelligent monitoring for your transformer

Bend Sensor Technology Mechanical Application Design Guide

SURFACE ANALYSIS STUDY OF LASER MARKING OF ALUMINUM

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

COPYRIGHT 2013 LED ENGIN. ALL RIGHTS RESERVED. LZ4-00R300 (6.0-09/19/13)

WHO WE ARE MISSION STATEMENT

LZP-Series Highest Lumen Density Cool White Emitter LZP-00CW00

Feature. Accelerate Business Development Contributing to Further Enhance Ophthalmic Treatment in Asia. 2020, our goal is to become #1 in

JUST SCRATCHING THE SERVICE

HYGIENIC, RELIABLE, AND ELEGANT DOOR SOLUTIONS FOR DEMANDING APPLICATIONS. KONE hermetic doors

High Performance Computing

High-power IGBT Modules

LZ4-00UA10. LedEngin, Inc. High Efficacy UV LED Emitter. Key Features. Typical Applications. Description

Calibrating Industrial Temperature Sensors Understanding the Dynamic Elements to Reduce Intrinsic Uncertainty

High Radiant Flux Density 400nm Violet LED Emitter LZP-00UA00

PECL DIFFERENTIAL CRYSTAL OSCILLATOR SOLUTIONS FOR TODAY S HIGH SPEED DIGITAL DESIGNER

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Laird Engineered Thermal Systems Application Note. Active Cooling of Optical Transceivers

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

Temperature References for Highest Accuracy Industrial Thermocouple Measurements

LZ4-00D110. LedEngin, Inc. High Efficacy Dental Blue + UV LED Emitter. Key Features. Typical Applications. Description

Tested and ready to use Quality from a single-source

IMPROVING PATIENTS SELF-INJECTION EXPERIENCE

Department of Energy s Legacy Management Program Development

Prof. Steven S. Saliterman. Department of Biomedical Engineering, University of Minnesota

4/8/2018. Prof. Steven S. Saliterman Department of Biomedical Engineering, University of Minnesota

Pharmaceutical Products and Services

6530 TeraOhm Bridge-Meters

Howard Smart Transformer Specification Guide

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Cost drivers in microwave antennas

Case Study Vein Viewer Product Development

Implementing Quality Systems

COPYRIGHT 2013 LED ENGIN. ALL RIGHTS RESERVED. LZ4-00G100 (5.4 11/18/13)

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Advantages of Powder Coating vs. Wet Paint

PhlatLight White LED Illumination Products. SST-90 Series PRODUCT DATA SHEET. Features. Table of Contents. Applications

OmniCure Setting the Standard for Precision Assembly UV Curing

Leveraging Technology to Find New Pathways for Business Growth

PyroGenesis Announces Receipt of AS9100D Certification for Aviation, Space, and Defense Industries; Provides Update on AM Business Line

FAQ. What is the Qualcomm Tricorder XPRIZE competition?

SST-50 W LEDs. SST-50 W Product Datasheet. Features: Table of Contents. Applications

Customized Sensors. OEM Custom-designed Sensors...from the leader in the measurement of mechanical parameters

COMPANY PROFILE. Our Mission...To Exceed Our Customers Expectations of Quality, Service, and Innovation.

LedEngin, Inc. High Luminous Efficacy Deep Red LED Emitter LZ1-00R205. Key Features. Typical Applications. Description

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

what is a multiplier? how does a multiplier work? common multiplier applications II. Assembly Type III. Other Design Concerns

Bringing Technology and Product Development Best Practices Together for Successful Innovation

XMA Corporation. June 1, RF High value passive interconnect and termination solutions

Leader in Pharmaceutical Films

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

LedEngin, Inc. High Luminous Efficacy Red LED Emitter LZ4-00R110. Key Features. Typical Applications. Description

COMPANY PROFILE. Our Mission...To Exceed Our Customers Expectations of Quality, Service, and Innovation.

Development of power transformer design and simulation methodology integrated in a software platform

Analytical Development Labs

Omnicure S1500 UV Spot Curing System. 122, Chemin de la Cavée Orgeval Tèl :

Optimizing the Movement of a Precision Piezoelectric Target Positioner. James Baase. Victor Senior High School Rochester, NY

High Luminous Efficacy Red LED Emitter LZ4-00R100

NEWS RELEASE. Life sciences companies tout their expertise in India

CBT-39-UV LEDs. CBT-39-UV CBT-120 Product Datasheet. Features: Table of Contents. Applications

TRACEABILITY WITHIN THE DESIGN PROCESS

LZ1-00WW05. LedEngin, Inc. High Luminous Efficacy Warm White LED Emitter. Key Features. Typical Applications. Description

Transcription:

ISO 9001:2008 Certified Parallel Prototyping and the Engineer s Dilemma Develop innovative products quickly, with superior quality, while controlling cost Heatron, Inc. 3000 Wilson Avenue, Leavenworth, KS 66048-4637 (877) 553-9070 +1 (913) 651-4420 www.heatron.com sales@heatron.com

1. Introduction In the high-stakes game of medical device development, time-to-market, safety, compliance and cost are all critical factors in attaining success. Couple this with the Engineer s Dilemma, develop innovative products quickly, with superior quality, while driving out costs, engineers find themselves faced with rapidly shrinking development cycles and rising competitive pressures. Parallel prototyping is a tactical tool that can reduce time-to-market and uncertainty. This white paper demonstrates how the parallel prototyping of two materials, Aluminum Nitride (AlN) and Alumina (Al2O3), in a heating component design for low- to medium-volume production contributed to this success. It also addresses the verification, validation, form and fit testing relative to the FDA (Food and Drug Administration) approval process. 2. The Challenge A leading manufacturer of respiratory therapy equipment approached Heatron to develop a heating element with very specific function, form, fit and cost requirements for their next generation breathing aid system. The product configuration consist of a water jacket design that uses the insulating heat of warm water to maintain gas temperature and humidity all the way to the patient, thereby managing secretions, maximizing patient comfort and, above all, compliance with the prescribed treatment. The warm water is created as it passes through a heater. Heater power is continuously regulated to maintain the optimum temperature needed by the system. 3. Design Requirements The heating element needed to be capable of fast thermal cycling and optimal heat transfer rate to maintain proper humidity and temperature for optimum patient comfort. The heater control system had to regulate variations in flow rates and optimum temperatures to accommodate neonatal and adult patients while maintaining set body temperature and high humidity rates. Specific design requirements include: Capacity to maintain a humid air temperature range between 25 C to 43 C adjusted for patient comfort (Resolution: 1 C / Accuracy: ± 2 C) Warm up time: ± 2 C of 33 C set point < 5 minutes at ambient 23 C Control sensors: integral K-type thermocouple or other recommended options Electrical resistance: 64 Ohms (± 15%) 90 Volts RoHS compliant Constructed for low current leakage Designed to meet UL 60101-1 (safety requirements for medical electrical equipment and FDA clearance) Finally, the heating element was a retrofit to the customer s existing medical device.

4. Impact of Parallel Prototyping to the Product s Design Heatron reviewed multiple potential solutions to meet the design requirements, including Kapton and all polyimide flexible heaters and four thick film heater materials. Both of the Ceramic Core technologies, Aluminum Nitride (AlN) and Alumina (Al2O3), proved leading candidates to achieve the design requirements. To arrive at the optimum solution for this project, Heatron parallel tested Aluminum Nitride (AlN) and Alumina (Al2O3) Ceramic Core heaters. The criteria for determining which heater was best suited for the customer s system included thermal conductivity, heat transfer rate, and ramp rate for best humid air temperature output control. Testing was also conducted to determine which technical solution provided the best cost/price advantage for lower total cost of ownership enabling the customer to make the best decision for their particular market needs. 5. Meeting the Challenge 5.1: Side-by-Side Comparison Both Aluminum Nitride (AlN) and Alumina (Al2O3) are a clean, non-contaminating heat source. Durable, non-porous, moisture and chemical resistant, both have uniform surface temperature, low leakage current and low-outgassing. Key Specifications Max Watt Density Thermal Conductivity AlN Al2O3 155 W/cm 2 11.6 W/cm 2 220 W/mK 35 W/mK Ramp Rate 300 C/sec 50 C/sec Coefficient of Thermal Expansion 4.6 x 10-6 / C 6.7 x 10-6 / C Heat Capacity 0.72 J/g-K 0.88 J/g-K By parallel prototyping this project, Heatron was able to achieve a higher quality design, reduced R&D costs, faster path to market, and valuable insights that ultimately helped design a product superior to the competition. The Alumina Ceramic Core heater has the highest insulation standoff per unit thickness and lower cost. Though it has lower maximum watt density, thermal conductivity and slower ramp rate, it meets the customer s specifications. Parallel prototyping was used because side-by-side prototyping provides feedback comparisons that present alternative ways to achieve project requirements.

5.2: Component Design Verification and Validation The objective at this stage in the engineering prototype is to verify that the design, materials, controls, and processes accurately represent the final production unit, and that the product will perform to specifications. This stage also includes evaluating pre-production prototype costs. Heatron tested each heating element using: Real-time thermography to prove ramp up and cool down rates, and ensure desirable heat profile. Control system testing: thermocouple output when the thermocouple is installed at various locations of the heater assembly in a dynamic power up over set time period Safety testing to determine the heater circuit s voltage in isolation with respect to the thermocouple and load Repeatability and reliability of systems and processes Critical design review 5.3: Product Design Verification and Validation At this stage, the customer installed the heater assemblies in their equipment for complete system verification and to validate which best meet hospital staff and patient needs for design refinement. Functional testing Performance testing Usability testing Reliability testing Environmental testing Regulatory compliance Change control Pilot production readiness review While parallel prototyping effectively helped determine which heating technology to build, the final solution was largely influenced by the customer s specific market needs. A limited number of prototypes were developed to provide the basis for analyzing technical feasibility, form, fit, costs and market acceptance within the customer s product. Preceding Heater s Profile Temperature ( C) Preceding Load Preceding Control Washer Control Heatron TCO Heatron Load Time (Minutes) Heatron s Profile is optimized for greater efficiency

6. Product Discoveries 5.4: Pilot Production Verification and Validation This stage verifies the design has been correctly executed for the manufacture of the heating element and assembly into the customer s product. Rigorous design reviews at this gate confirm all customer specifications are met and the manufacturing process is feasible and repeatable. Design reviews at critical junctures led to new insights and opportunities to reduce development time, ensure efficiency and quality, and provide the lowest cost solution. The evidence collected established the importance of the thermal-interface-material (TIM) to enhance heat transfer and justified its use. We improved thermal conductivity with a thermally insulating cover, making the heater transfer energy load better. Combined, this made for a much better retrofit that ran more efficiently. The heater s voltage isolation went from 2500 VAC to 4000 VAC with Heatron s design. Thermocouple placement options were examined and we designed a mounting system that perfectly mimicked the target thermocouple response. We discovered a very simple system that allowed us to adjust the response so the existing control system s algorithms and firmware did not require modification. Heating assembly provides intended results Procurement analysis and plan in place Process instructions ensure ease of fabrication and assembly ISO 9001 quality system, documentation, material and component traceability Compliance testing to meet FDA requirements, RoHS, outgassing and other specifications Packaging and labeling Manufacturing readiness review Design reviews when parallel prototyping enhances the discovery process and uncover potential problems early, before the cost of correction are higher.

7. Benefits of Parallel Prototyping The divergent/convergent nature of parallel prototyping stimulates greater discovery of unseen opportunities and constraints, which can lead to more diverse solutions and feedback from users. The greater the degree of product development uncertainty, the stronger the case for parallel prototyping. Engineers learn from concurrent experiments. They see more data, sooner, and understand from a position of certainty. They are more likely to head off potential trouble spots and develop more robust designs. Moreover, parallel prototyping can double the user/patient involvement, which increases quantifiable user feedback. This facilitates higher patient satisfaction and greater compliance with the recommended treatment. The trade-off to this speed and performance is in the initial development costs. In this case, one material property was contested against another. The total cost was actually less than serial prototyping, lowering the cost of total ownership. Economies of scale are inherent in parallel prototyping since much of the development costs are fixed. Further, engineers gain an understanding of critical opportunities to improve device quality and insights for future enhancements. 8. Conclusion In solving the Engineer s Dilemma (how do you develop a product quickly, with superior quality while controlling cost?), parallel prototyping offers great upside potential. There are many paths to a solution, but few are optimal. Whether product development is in the highly regulated medical device industry or one with few constraints, parallel prototyping contributes to innovative ideas that accelerate time-to-market, reduce cost and yield a greater return on investment. All critical factors in attaining success. References: 1. Nebraska Business Development Center, University of Nebraska at Omaha College of Business Administration, Goldsmith Technology Commercialization Model, http://www.slideshare.net/ bronwenelizabeth/technology-commercialization-43253829 2. Kenneth A. Crow, President of DRM Associates, http://www.npdsolutions.com/dfmguidelines.html Parallel prototyping provides greater assurance in the Design for Manufacture and Assembly (DFMA) process. 3. Dow, S. P., Glassco, A., Kass, J., Schwarz, M., Schwartz, D. L., and Klemmer, S. R. 2010. Parallel prototyping leads to better design results, more divergence, and increased self-efficacy. ACM Trans. Comput.-Hum. Interact. 17, 4, Article 18 (December 2010), 24 pages. DOI = 10.1145/1879831.1879836 http:// doi.acm.org/10.1145/1879831.1879836

About the Author Craig Sundberg is Manager of the Thick Film Engineering R&D Laboratory and Thick Film Application Engineer. Craig holds a degree in Material Science from Gannon University, Erie, Pennsylvania. Craig has been designing thick film heaters and circuits for over 35 years, making him one of the most experienced engineers involved in Thick Film Electronics in the world. Craig is a listed inventor on numerous patents relating to thick film and his work has directly resulted in the production of millions of thick film circuits and heaters. About Heatron Heatron is a global leader in the design, engineering and manufacturing for heating solutions. Heatron s experienced engineers offer complete solutions, from initial concept and design to complex integration and manufacturing for low- to high-volume production requirements. Heatron takes a complete systems approach to identify intelligent solutions for a wide range of thermal management and integration issues. Heatron models, simulates, designs, integrates and validates your component before productions to identify optimal design while driving out waste. Our expertise in design, manufacturing and market standards provides our customers with the documentation and knowledge of agency approvals that is essential in today s tightly regulated environment. To learn more, contact a sales representative at sales@heatron.com or call (913) 651-4420 Heatron, Inc. 3000 Wilson Avenue, Leavenworth, KS 66048-4637 (877) 553-9070 +1 (913) 651-4420 www.heatron.com sales@heatron.com