Agenda. 1. Inverter technology. 2. Monitor system. 3. System application. 4. Error Codes and trouble-shooting

Similar documents
Troubleshooting for Growatt TL&MTL. (Ver1.2)

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface

Tel: Fax:

Fault 514: communication error between the meter and the SH5K+

PV Grid-connected Inverter

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)

Grid-Tied Home Energy Production Using a Solar or Wind Power Inverter without DC-to-DC Converter

The future-proof inverter for small self-consumption systems

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

Installation requirements

CP /240-MC4 User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS CENTRALIZED MODELS PLUS

DC PV Arc fault detection Unit

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS ULTRA CORE PLUS

ENGINEERING THESISS ENG460

Page 1 of 28. Ingo Röhr. Frank Hesmer

Anti-IslandingStrategyforaPVPowerPlant

PV Grid-connected Inverter

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

APS M1P Single-phase Micro-inverter Installation and User Manual

Solmetric PVA-600 PV Analyzer

Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

Doc. EA Model Number:

Advanced Test Equipment Rentals ATEC (2832)

Orbital GFI Inverter Series

Sunny Tower. The Flexible Solution for Commercial PV Systems

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M)

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

Utility Interconnection and System Protection

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

METREL Measuring and Regulation Equipment

Technical Requirements for Connecting Small Scale PV (sspv) Systems to Low Voltage Distribution Networks

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0

TOSHIBA International Corp

THEIA series. StRing inverters

AC/DC Power Supply Series APPLICATION NOTE

Photovoltaic Based Single Phase Grid Connected Transformer Less Inverter

TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011

Impact of High PV Penetration on Grid Operation. Yahia Baghzouz Professor of Electrical engineering University of Nevada Las Vegas

PV210. Why buy the PV210?

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

Connection Impact Assessment Application

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

New Tools for PV Array Commissioning and Troubleshooting

Assessment and Evaluation of Single Phase Grid Linked Transformer less Inverter with PV Input

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator

HD WAVE INVERTERS. (+34) Skype

Photovoltaic / Solar Array Simulation Solution

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

AC/DC Power Supply Series APPLICATION NOTE

THE DESERT KNOWLEDGE AUSTRALIA SOLAR CENTRE: HIGH VOLTAGE EFFECTS ON INVERTER PERFORMANCE.

New Tools for PV Array Commissioning and Troubleshooting

Gutor PxW AC UPS Designed for North American Market

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

E N G I N E E R I N G M A N U A L

FusionSolar Smart PV Solution

Protective Relaying for DER

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software

Cree PV Inverter Tops 1kW/kg with All-SiC Design

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

AC/DC Power Supply Series APPLICATION NOTE

SOLON Corporation Potential Induced Degradation

New Tools for PV Array Commissioning and Troubleshooting

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

SOLADIN 2200 WEB / 3000 WEB GRID CONNECTED SOLAR INVERTER

Emergency lighting units EM powerled

Embedded Generation Connection Application Form

Electronic Circuit Breaker ESS1 for System SVS1

Tel Fax

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

Your Origin SLIVER system will be supplied with one of the following sets of panels:

- 1 - GTI Grid Series. GTI Series Inverters For Grid User Manual

Application Note: String sizing Conext CL Series

Modelling of Photovoltaic power plants in SIMPOW

Solmetric White Paper: Winning Contracts with PV Array Testing

Embedded Generation Connection Application Form

APPROVAL SHEET 12V/2A EA1019HHUS(03) EA1019HHUS-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

BED INTERCONNECTION TECHNICAL REQUIREMENTS

ENS26 Automatic Isolation Unit Product Description

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

Smart Inverter Testing for Autonomous Grid

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Control of Power Converters for Distributed Generation

Embedded Generation Connection Application Form

2016 3rd Conference on Power Engineering and Renewable Energy (ICPERE 2016)

ENS31 Automatic Isolation Unit Product Description

Upsolar Smart Modules

Photovoltaic Systems Engineering

Company Profile. Skype: carrie.rong Mob/Whatsapp: Web:

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

CAMTO. Arc detecting relay. system. January Revised August D D1200

Transcription:

Technical FAQ

Agenda 1. Inverter technology 2. Monitor system 3. System application 4. Error Codes and trouble-shooting 2

01 Inverter technology 3

1.1 What s the topology of zeversolar inverters? Single phase inverter Heric H5 H6 Three phase inverter 2level I style 3 level T style 3 level 4

1.2 What would inverter do under high ambient temperature? In order to ensure inverter operation under safe conditions, the device may automatically decrease power output due to increased ambient temperature. ou can fine inverter s power reduction curve in the installation and operating instructions TLC 20K TL 5000 5

1.3 Why does inverter equipped with DC switch? ormally, according the PV installation standard, DC Switch is necessary for safety consideration. It can be installed either inside of inverter or outside. If there is AJB (Array Junction Box), the DC switch can be installed in AJB. However, we recommend inverter integrated with DC Switch, because of cost saving by removing AJB and easy consideration. 1.4 Which EMC standard does zeversolar inverter conform? Zeversolar inverters are designed according to IEC61000-1-2 and IEC61000-1-3 for commercial use. The EMI level is similar with a TV. 6

1.5 What s the deviation between displayed energy and actual energy? 1% 1.6 Which kind of capacitor is used inside inverter? Electrolytic capacitor Smaller size, lower cost, higher capacity, smaller ripple, more reliable. 1.7 which kind of inverter does zeversolar produce? Isolated or non-isolated? Zeversolar only produce non-isolated(transformerless) inverters. Transformless inverter is the most common inverter in the market. It has a higher efficiency, lower cost, smaller volume. 7

1.8 what kind of protections does zeversoalr inverter have on both DC and AC side? DC Side: PV Overvoltage Protection PV Overcurrent Protection and Control PV Reverse Polarity Protection PV Insulation Resistance Low Protection/ISO Protection/PV Ground Protection DC Bus Voltage Over Protection AC side: AC Overvoltage Protection AC Undervoltage Protection AC Overcurrent Protection AC Overfrequency Protection AC Underfrequency Protection AC Short Protection AC Grid loss Protection / Island Protection Output Inject DC Current Over Protection/ DC IJ. High Protection Output Leakage Current Over Protection/ GFCI Protection 8

02 Monitor system 9

10 2.1 Monitoring solution(residential)

11 2.2 Monitoring solution(commercial)

12 2.3 How to download inverter s history running data History running data cannot be download from inverters directly. It can only be downloaded from solar cloud. Besides, for three phase inverters (TLC series), you can check some history data on the screen.

2.4 Can I just use a computer to monitor zeversolar inverters without internet connection? Zeversolar monitor solution is PMU +Solarcloud, which requires internet connection. But we can provide communication protocol for customers to develop their own monitor system. Otherwise, you can use 3 rd party monitoring device and software, e.g. Solarlog, etc. 2.5 How to use 3G GRRS to access the internet? Buy a 3G/3.5G GRPS wireless router, connect the ET port of PMU to this router, then you can access the internet through 3G net. 2.6 Can I get environment information from Solarcloud? Solarcloud does not contain the information of environment information (irradiation, temperature, wind speed). We are planning to have this function in 2015. If you want to get these information, you can either buy separate environment monitor system, or you can use solar-log instead of PMU, solar-log can connect to environment sensor. 13

03 System application 14

3.1 PV diesel Hybrid Application The diesel generator supply grid reference signal for the inverter. The capacity of all the inverters should less than the capacity of the load. The capacity of all the inverters should less than 60% of the max genset capacity. 15

3.2 How to configure zeversoalr inveters with PV modules. Our inverter is suitable for most of monocrystalline or polycrystalline modules. When you configure the modules, please consider follow factors: Module parameters Environment conditions Geometric data Maximum DC power Strings number umber of modules in one string The open voltage under extreme high and low ambient temperature Etc. Zeversolar has a free system configuration software Zeverplan. Zeverplan simplifies the entire PV planning process creating the optimum solar power plant configuration is within just a few minutes. As a cloud based application, Zeverplan is available online at no extra cost and without having to install any software. Registered users have access to a monthly updated module database, worldwide meteorological data and the possibility to input own module information, profiles and unique project templates. It ś easy to operate by reseller, installer, end user and PV plant designer etc. 16

3.3 Can I use thin-film modules for zeversolar inverter? Zeversolar inverters are not recommended for thin film modules, they are transformerless and designed for silicon modules. We suggest user to use isolated inverters which is designed for thin-film module. It is OK to use zeversolar inverter if the thin-film module is not grounded. But if the module need to be grounded, isolation transformer is required to connect with inverter, which is not cost effective. 3.4 Can I oversize the inverter with more modules? Our inverter can work with more modules, but we do not recommend to do so. The reliability of inverter might be decreased if too many modules are configured. 17

3.5 How to realize the power management? through RRCR(radio ripple control receiver), you can adjust the output according to grid instruction. if there is no grid instruction, you can log the webserver of PMU to give a setting. Inverter will control automatically the output according to the PMU setting. 3.6 Can zeversolar inverters applied to Anti Reverse Power systems? If the local regulation does not allow PV power feed into grid, we can control the output power with PMU for anti-reflux.(only for German code inverter) 18

3.7 1MW solution with 20K inverters 4strings, 20modules for 1 string 4strings, 20modules for 1 string 4strings, 20modules for 1 string 4strings, 20modules for 1 string Environment detector Eversol TLC20K 1# 8# 1# 8# Use 50 string inverter of 20kw combined on AC side directly Suitable for industry, commercial and residential rooftop Copy this solution to create several MW station Local load 160kW AC combiner 1# 380V Low voltage bus AC combiner Meter 380V 2 winding boost transformer 160kW AC combiner 7# Middle Voltage Grid Monitoring system Features: High efficiency for each inverter More energy production, each inverter have its own MPPT Low power loss during individual inverter down time Easy to install, mounting on the racking structure or tracker Built-in DC fused combiner and disconnect, no need of DC combiner box Maintenance and servicing is much easier and less expensive 19

04 Error Code & Troubleshooting 20

4.1 LCD Blank LCD Blank LCD and LED indicator can t be light on Check if DC breaker is on Turn on DC breaker Check if polarity Of PV input is right Reverse the PV polarity Check if PV voltage is in the range Please check PV configuration ou can through the bellow method to contact zeversoalr service Service line/e-mail/on-line Claim End

4.2 E38 Isolation Fault E38 (Isolation Fault) When the inverter detects low resistance between PV panels and ground, the error will be occured Check if the PE wire connected to the ground well Please connect PE wire well Check if the weather is rainy when this fault happens Check if the inverter Can be recovery in sunny day Check if both the values are greater than 900Kohm This is not the inverter s problem, please contact the electrician check relevant cables ou can through the bellow method to contact zeversoalr service Service line/e-mail/on-line Claim End

4.3 E33 Fac out of range E33 (Fac out of range) When the frequency is higher or lower than the spec required, this error will be happened Check if the grid frequency value is right Please contact electrician Check if the frequency value on display is right Turn off AC and DC for about 5mins and restart inverter, Can it work normally ou can through bellow methods to contact zeversoalr service Service line/e-mail/onlineclaim Change high and low limited value through LCD (3P) End

4.4 E34 Vac out of range E34 (Vac out of range) When the voltage is higher or lower than the spec required, this error will be happened Check if the grid voltage value is right Please contact electrician Check if the voltage value on display is right Turn off AC and DC for about 5mins and restart inverter, Can it work normally ou can through bellow methods to contact zeversoalr service Service line/e-mail/onlineclaim Change high and low limited value through LCD (3P) End

4.5 E35 Utility Loss E35 (Utility loss) When the inverter can t detects the grid,this error will be occurred Check the grid voltage on display is normal Check if the AC plug have a right connection Reconnect the AC wires again Check if the AC breaker is on Turn on AC breaker Check if the AC Voltage is too low Please contact electrician ou can through bellow method to contact zeversolar service Service line/e-mail/onlineclaim End

4.6 E37 PV over voltage E37 (PV over voltage) When the inverter detects the PV voltage over spec,this error will be occurred Check PV system voltage can satisfy spec Please contact installer Check the PV voltage on display is in spec range Decrease the PV panel quantity Turn off AC and DC for about 5mins can it work normally ormal phenomenon ou can through bellow method to contact zeversolar service Service line/e-mail/onlineclaim End

4.7 E40 Over Temperature E40 (Over Temperature) When the inverter detects the temperature over spec,this error will be occurred Check if the inverter s environment has heat producer Change installation position Check if the inverter can work normally when temperature decreased ormal phenomenon ou can through bellow method to contact zeversolar service Service line/e-mail/onlineclaim End

4.8 Error Codes Error Code Description Contact Service Directly 01 Communication Fails between M-S If these error happed, please 02 EEPROM R/W Fail through bellow method to contact zeversolar service 04 DC Injection High directly: 05 The result of Auto Test Function is fail Service E-mail 07 The voltage reference inside is abnormal China : service.china@zeversolar.com 08 AC HCT Failure ROW: 09 GFCI Device Failure service.row@zeversolar.net AU: 10 Device fault service.apac@zeversolar.com 11 M-S version unmatched EU: 41 42 Consistent Fault:Vac differs for M-S Consistent Fault:Fac differs for M-S service.eu@zeversolar.net Service Line 43 Consistent Fault:Groud I differs for M-S 44 Consistent Fault:DC inj. differs for M-S 45 Consistent Fault: Fac,Vac differs for M-S 47 Consistent Fault Online claim

Three method to contact zeversolar service Service E-mail China : service.china@zeversolar.com ROW: service.row@zeversolar.net AU: service.apac@zeversolar.com EU: service.eu@zeversolar.net Service Line China: +86 512 6937 0998-8866 ROW: +86 512 6937 0998-8954 EU: +49 (0)2102 420 944 AU: +61 (0)1300 101 883 Online claim http://www.zeversolar.com/service/online-claim/

Thank you. Energy for everybody. Jiangsu zeversolar ew Energy Co., Ltd. Add: Building 9, o. 198 Xiangyang Road, Suzhou, Jiangsu, China 30

The ideas developed here are the intellectual property of the Zeversolar and is subject to copyright. The whole or partial use of any kind, including transfer to third parties, is not permitted without written approval of Zeversolar. 31 Company Information