CSD Series Current Devices Solid Core with Relay

Similar documents
Installation Instructions

TE-6300P Series Temperature Sensors

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

FX-WRZRMT10K-0 Wireless Remote Temperature Transmitter

WRZ Receiver for One-to-One Wireless Room Sensing Systems

v.wrs-rtn Series Receivers for Many-to-One Wireless Room Temperature Sensing Systems

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

LX Scheduler. Installation Instructions LX-SCHEDL-0. Mounting. Applications. North American Emissions Compliance. Installation

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

HLC-1000 High-limit Humidity Control

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Automation Components, Inc. CURRENT 4-20 MA OUTPUT

INSTALLATION MANUAL Model 1923 Load Cells Certified for Explosion Safety na Non-Sparking

WRZ-SST-120 Wireless Sensing System Tool

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

TVB-2 INSTRUCTION SHEET. Test Verification Box

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Mid-Power Expansion Unit (MxU) Quick Installation Sheet

Important Safety Instructions

DISCONNECT POWER PRIOR TO ANY INSTALLATION.

SPECIFICATION, CONTROLS AND ACCESSORIES

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Instruction Sheet VDM-200-T. Tilt Wall Mount

Instruction Sheet. VDM Series. Tilt Low Profile Mount

ROUND LIGHTPLANE 1 3D FLUSH

INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Polycom VoxBox Bluetooth/USB Speakerphone

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

Electronic Controls For general purpose and multi stages controls. Features and Benefits

PART # mA Positioner

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

Power Supplies 3. SDN-C Compact DIN Rail Series

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Trusted Power Distribution Unit MCB 24 Vdc

High Frequency Sinewave Guardian TM Filter

ASSEMBLY INSTRUCTIONS

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

MODEL CTR - TRUE RMS AC CURRENT TRANSDUCER

SLC 500 RTD/Resistance Input Module

Installation and Operating Instructions for Phase Demodulator Type _.2

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

Technical Instructions Document No EA GQD June 23, OpenAir

Installation and Operational Instructions for ROBA -switch Type 017._00.2

BT11 Hardware Installation Guide

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

SUPERPLANE TM 4 RECESSED SP4R

SPECIFICATION, CONTROLS AND ACCESSORIES

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

DEH-036 Instructions. ASTAT-SD Solid-State Reduced Voltage Starter

ETG-A200. LED Remote Phosphor Outdoor Lighting

Universal TechBox Series

MST-5. Varifan USER S MANUAL MST-5 5 STAGE THERMOSTAT. computer compatible ADJUST. 9 reduc. per day 8 7 F rel. rel. rel. rel.

Zelio Control Measurement Relays

ControlNet Modular Repeater Medium Distance Fiber Module

Regulatory Compliance Statement

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

4344 SERIES HERMETIC SEALED THERMOSTATS

Occupancy Sensor OCS 100W Setup Guide

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

BC145 SIGNAL ISOLATOR BOARD

AMC mA Positioner

Broadband Step-Up Transformer. User Manual

FLEX Integra 2 Output Analog Module

AD-8100 & AD-8200 Servo Amplifiers

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

LPK1550 Hydraulic Crimping Tool 15-ton

Deploying Current Transformers in Applications Greater Than 200 A

Installation Instructions Space Temperature Transmitter

Single Phase Soft Starters

High Frequency SineWave Guardian TM Filter

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

INSTRUCTION MANUAL FOR DIODE FAULT DETECTOR

DM-45 Digital Multimeter

CBCT TM CIRCUIT BREAKER COIL TESTER

Regulatory Compliance and Important Safety Information

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

SCC-CO20 Isolated Current Output Module

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

Installation and Operating Instructions. Power IT Power Factor Controller RVC

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Product Data Sheet RER190-39/14/2TDMO

FR-ABR-(H)0.4K to 22K

Occupancy Sensor OCS 100W Setup Guide

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

EVERGREEN EM INSTALLATION GUIDE

Tube Facing Tool.

Product Data Sheet RER220-43/18/2TDMO

Transcription:

CSD Series Current Devices Solid Core with Installation Instructions CSD-SA1E1-1 CSD-SA1E2-1 Part No. 24-10345-26, Rev. F Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch Device (CSD) Series of digital output switches are nonintrusive devices designed to detect current flowing through a cable or wire. A cost effective solution for monitoring on and off status or proof of operation, these units are ideal for monitoring small current loads on motors driving fans and blowers, heating coils, and lighting. The CSD models with command relays not only monitor current flowing through the cable but also facilitate starting and stopping the motor. These units provide a universal solid state output. Power for the current sensing circuit is derived from the current induced from the cable or line being monitored. The CSD-SA1E1-1 command relay requires a separate 24 VAC/VDC power supply, and the CSD-SA1E2-1 command relay requires a 12 VAC/VDC power supply. IMPORTANT: The Current Switch Device (CSD) Series Current Devices are intended to provide an input to equipment under normal operating conditions. Where failure or malfunction of the CSD could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the CSD. IMPORTANT : Le Current Switch Device (CSD) Series Current DeviceS est destiné à transmettre des données entrantes à un équipement dans des conditions normales de fonctionnement. Lorsqu'une défaillance ou un dysfonctionnement du CSD risque de provoquer des blessures ou d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du CSD. Refer to the QuickLIT website for the most up-to-date version of this document. IMPORTANT: Install the CSD Series Current Devices only on the input side of a variable speed drive. Otherwise excessive wear may occur on the controlled equipment, as well as premature failure of the CSD Series Current Devices. Installation!! WARNING: Risk of Electric Shock. Disconnect the power supply before making electrical connections. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. AVERTISSEMENT : Risque de décharge électrique. Débrancher l'alimentation avant de réaliser tout branchement électrique. Tout contact avec des composants conducteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. WARNING: Risk of Personal Injury. Do not touch the relay attached to the CSD-SA1E1 device while power is applied to the relay. The relay surface is hot during use, and may cause a serious burn upon contact. AVERTISSEMENT : Risque de blessure. Ne pas toucher le relais connecté au CSD-SA1E1 lorsque le relais est sous tension. La surface du relais devient extrêmement chaude durant son utilisation et risque de provoquer des brûlures graves en cas de contact. CSD Series Current Devices Solid Core with Installation Instructions 1

Dimensions 65 (2-9/16) 40 (1-19/32) 5. Calibrate Model CSD-SA1E1-1 (see Setup and Adjustments). Contactor 65 (2-9/16) Figure 1: CSD Dimensions, mm (in.) Fig:sc_rel_frnt 27 (1-1/16) Fig:sc_rel_sde Control Power Coil 120 VAC 24 VAC/DC DO DI Mounting 1. Using the two screws (included), attach the mounting bracket to the back of the electrical enclosure. 2. Snap the CSD into place on the mounting bracket. Wiring 1. Disconnect power to the conductor cable from the power source. 2. Slide the power conductor cable to be monitored through the sensing hole of the CSD. 3. Wire the CSD/Command as shown in Figure 2. Note: The switch contacts are solid state, and they work just like dry contacts. When the switch is closed, less than 1 ohm is present; when the switch is open, more than 1 megohm is present. 4. Reconnect the power to the conductor cable (see Figure 2). Fan or Pump Figure 2: Model CSD-SA1E1-1 If the measured current is too low to be detected or is higher than the maximum current rating of the CSD, use the following methods to increase or decrease current. If Measured Current Is Too Low to Be Detected Wrap the conductor (wire) through the sensing hole and around the CSD body to produce multiple turns to increase the measured current. Measured current = actual current multiplied by the number of turns (see Figure 3). Fig:sc_rel_wre Fig:sc_rel_trns Figure 3: CSD Shown with Four Turns 2 CSD Series Current Devices Solid Core with Installation Instructions

IMPORTANT: Failure to derate the current capacity could result in damage to the CSD when using multiple turns to increase measured current. Use the following formula to determine the new maximum current: New Maximum Current = CSD Current Rating/ number of turns. For example, Model CSD-SA1E1-1 with 4 turns = 135 A/4 = 33.8 A, new maximum current. To Monitor Currents Exceeding the Maximum Current Rating of the CSD Use a 5 A Current Transformer (CT) to reduce the current passing through the CSD as shown in Figure 4. Run the current transformer secondary wire through the sensing hole. Terminate the two secondary wires of the 5 A current transformer to each other, and then install the 5 A current transformer on the conductor being monitored. Under Current Condition (Belt Loss, Coupling Shear, Fan, and Pump ) 1. Turn the setpoint screw clockwise until the Closed Light-Emitting Diode (LED) turns off and the Open LED turns on. Figure 5: Open, LED On 2. Slowly turn the setpoint screw counterclockwise until the Closed LED turns on and the Open LED turns off. Fig:sc_rel_stat_opn Current > 135 A Fig:sc_rel_stat_clsd Figure 6: Closed, LED Off Figure 4: CSD with CT Transformer Setup and Adjustments Calibration CSD Series Model CSD-SA1E1-1 and CSD-SA1E2-1 Position the CSD so the status output panel faces you. Confirm that the monitored load (for example, a motor or heater) is running, and then use the following methods to calibrate the CSD. Fig:sc_csd_wct 3. Turn the setpoint screw an additional 1/4 turn counterclockwise to create a deadband to prevent hunting. The CSD is now calibrated to signal current flows below normal full load Amperes. Output : Normal: Output Closed Alarm: Output Open Over Current Condition (Locked Rotor, Seized Impeller) 1. Turn the setpoint screw counterclockwise until the Open LED turns off and the Closed LED turns on. CSD Series Current Devices Solid Core with Installation Instructions 3

Note: This is the default factory setting. Figure 7: Closed, LED On 2. Slowly turn the setpoint screw clockwise until the Closed LED turns off and the Open LED turns on. Figure 8: Open, LED On Fig:sc_rel_stat_clsd Fig:sc rel stat opn 3. Turn the setpoint screw an additional 1/4 turn clockwise to create a deadband to prevent hunting. The CSD is now calibrated to signal current flows above normal load amperes. Output : Normal: Output Open Alarm: Output Closed Accessories See Table 1 for accessories. Table 1: CR-01200-0 and CR-02400-0 Command s Product Code Product Description CR-01200-0 12 VAC/VDC Single-Pole, Single-Throw (SPST), Normally Open (N.O.) CR-02400-0 24 VAC/VDC Single-Pole, Single-Throw (SPST), N.O. Repair Information If the CSD Series Current Device fails to operate within its specifications, replace the unit. For a replacement CSD, contact the nearest Johnson Controls representative. 4 CSD Series Current Devices Solid Core with Installation Instructions

Troubleshooting Table 2: Troubleshooting Symptom CSD solid state output does not function. Setpoint screw keeps turning. Motor is turned on and switch does not close. Action Verify the maximum amperage range has not been exceeded. Voltages or currents above the rated levels may damage the CSD. The setpoint screw has a slip clutch to prevent damage to either end. To return the LED to its original setting, turn the setpoint screw 20 full turns counterclockwise and start the calibration procedure again. Insufficient current to the load leads (for example, a motor or heater) to reach the setpoint threshold. To turn the switch on, wrap the cable multiple times through the sensing hole (see Figure 3). Technical Specifications Solid Core Models CSD-SA1E1-1/CSD-SA1E2-1 Product Code CSD-SA1E1-1 CSD-SA1E2-1 Amperage Range 1.00 135 A Switch Setpoint Adjustable Output SPST, N.O., 10 A at 260 VAC, 5 A at 30 VDC Actuation Coil 20 30 VAC/VDC, 40 85 ma Maximum 10 14 VAC/VDC, 25 45 ma Maximum Switch LED Indication Yes LED Indication Yes Trip Setpoint Value 1.00 135 A Current Switching Mode Over/Under Current Sensing Sensor Supply Voltage Induced from power conductor cable. Wire Size 2.1 0.6 mm (12 22 AWG) Diameter Output Switch Normally Open. Switch Load Capacity 1 A at 30 VAC/42 VDC Maximum Isolation Voltage 600 VAC rms Temperature Range -15 to 60 C (5 to 140 F) Frequency Range 50/60 Hz Humidity Range 0 95% Noncondensing Screw Torque 0.5 N m (4 lb in) Dimensions 65 x 65 x 40 mm (2-9/16 x 2-9/16 x 1-19/32 in.) Aperture (Sensing Hole) Size 18 mm Diameter (0.71 in. Diameter) Compliance United States UL Listed, File E310692, CCN NRNT, Under UL 508, Industrial Control Equipment Canada UL Listed, File E310692, CCN NRNT7, Under CAN/CSA C22.2 No. 14-M91 Industrial Control Equipment Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. Shipping Weight 0.16 kg (0.35 lb) The performance specifications are nominal and conform to acceptable industry standards. For application of conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2014 Johnson Controls, Inc. CSD Series Current Devices Solid Core with Installation Instructions 5 Published in U.S.A. www.johnsoncontrols.com