Principles of CT scan

Similar documents
TEP Optimization of the CT scan quality. Related topics Number of projections, stop angle, exposure time, image statistics, binning

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Alignment of the camera

TEP Principles of Digital X-ray Imaging

X-ray investigation of crystal structures / Laue method with digital X-ray detector (XRIS) (Item No.: P )

X-RAY COMPUTED TOMOGRAPHY

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

ADC COMPACT FULL-LEG/FULL-SPINE APPLICATION SOFTWARE USER MANUAL

NanEye in Awaiba Viewer

Handbook. Antenna Rotator Controller

An Activity in Computed Tomography

ON THE WAY TO DIGITAL RADIOGRAPHY

An Activity in Computed Tomography

STEM Spectrum Imaging Tutorial

QC Testing for Computed Tomography (CT) Scanner

Operating Procedures for MICROCT1 Nikon XTH 225 ST

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

DISC QC/QA Program for Digital Imaging Systems using the DR Radchex Plus Meter

Fluke199XRAY. Users Manual. Medical ScopeMeter

CR Basics and FAQ. Overview. Historical Perspective

v tome x m microfocus CT

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

X-Ray Tomography Inspection of SRF Cavities. Elvin Harms 15th International Conference on RF Superconductivity July 2011

Exercise 1-3. Radar Antennas EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION OF FUNDAMENTALS. Antenna types

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

3B SCIENTIFIC PHYSICS

inspexio SMX-225CT FPD HR

ACCU-GOLD QUICK START MANUAL

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

GUI - DLD Software. Manual

ZEN 2012 SP5 black edition Hotfix 12

4.5.1 Mirroring Gain/Offset Registers GPIO CMV Snapshot Control... 14

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Attenuation and velocity of ultrasound in solid state materials (transmission)

CCD reductions techniques

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

LUXONDES. See the electromagnetic waves. Product 2018 / 19

LSM 710 Confocal Microscope Standard Operation Protocol

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

Stitching MetroPro Application

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016

Magnetic induction with Cobra3

RENISHAW INVIA RAMAN SPECTROMETER

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P

ISONIC PA AUT Spiral Scan Inspection of Tubular Parts Operating Manual and Inspection Procedure Rev 1.00 Sonotron NDT

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

Information & Instructions

RAITH e-line OPERATING INSTRUCTIONS

The operation manual of spotlight 300 IR microscope

Design, Development and Integration of a Large Scale Multiple Source X-ray Computed Tomography System

Development of new dosimeter for measuring dose distribution in CT

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

Equipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

X-rays in medical diagnostics

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

Migrating from traditional to Digital Radiography in Aerospace

USB Line Camera 8M. Coptonix GmbH

3 Choose the Channels button and set the Channel Settings. Set the Pinhole to 1 Airy unit.

AgilEye Manual Version 2.0 February 28, 2007

Q3D. Speak to a 3D Specialist. CBCT 3D / Panoramic Imaging GENERAL DIMENSIONS. Suni Imaging Product Lines GET.

Application Report 11/15/5471 Company: Kienle Spiess

iq-led Software V2.1

Instructions for Tecnai a brief start up manual

Fig.2: Scanner VistaScan for image plates

universal Digital Radiography (DR) System

Digital Radiology with Photon Counting Detectors

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Cerro Tololo Inter-American Observatory. CHIRON manual. A. Tokovinin Version 2. May 25, 2011 (manual.pdf)

Planmeca Romexis. quick guide. Viewer EN _2

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Version 1.0. TechnicVR. Student Guide

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics

Image Processing Tutorial Basic Concepts

Maximizing clinical outcomes

Studuino Icon Programming Environment Guide

Multichannel Analyser, Extended Version

ScanArray Overview. Principle of Operation. Instrument Components

Goal of the project. TPC operation. Raw data. Calibration

Discover the difference in efficiency

SUPERLINEAR SPEEDUP IN PARALLEL 3D COMPUTED TOMOGRAPHY APPLIED TO LARGE OBJECTS IN CULTURAL HERITAGE

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Handbook for the Starlight Xpress AO unit Issue 1 21/8/2005 Handbook for the Starlight Xpress SXV-AO unit

Applications of the Cracow X-Ray Microprobe in Tomography

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

The CMS Outer HCAL SiPM Upgrade.

Automated workflow for Core Saturation experiment

BeamPro 3.0 Series User Manual Revision WARRANTY

Nuclear Associates , , CT Head and Body Dose Phantom

ULTRASONIC SIGNAL PROCESSING TOOLBOX User Manual v1.0

Zeiss 880 Training Notes Zen 2.3

Digital Panoramic X- Ray unit. Product Data

Transcription:

Related topics Detector calibration, saturation, CT acquisition, CT reconstruction Principle X-ray computed tomography consists of using X-rays that are converted to a digital signal by a detector and computational algorithms to calculate virtual sections through an object without the need to physically cut them. With this data it is possible to generate 3D representations of the sample under investigation. Both from the external as from the interior of the sample. Equipment 1 XRE 4.0 X-ray expert set 09110-88 1 XRCT 4.0 X-ray Computed Tomography upgrade set 09180-88 1 XR 4.0 Accessories for CT 09057-44 Additional equipment PC, Windows 7 or higher Fig. 1: P2550500 P2550500 PHYWE Systeme GmbH & Co. KG All rights reserved 1

Principles of CT scan Tasks 1. Perform a CT scan 2. Define the reconstruction parameters 3. Investigate the reconstructed volume Set-up Attach the XRIS to its stage. Place the Digital X-ray detector XRIS on the rail at position 30 cm. The back side of the XRIS stage corresponds to its position on the rail. This position is called the 'source to detector distance' SDD (mm). Connect the usb cable between the detector and the computer Fig. 2: Set-up of the XRIS Place the rotation stage XRstage on the rail at position 25 cm. The back side of the XRstage corresponds to its position on the rail. This position is called the 'source to object distance' SOD (mm). Connect the XRstage cable with the 'Motor' connection block in the experiment chamber. Attach the sample table to the XRstage with the fastening screw. Fig. 3: Set-up of the XRstage 2 PHYWE Systeme GmbH & Co. KG All rights reserved P2550500

Connect the X-ray unit via USB cable to the USB port of your computer (the correct port of the X-ray unit is marked in Fig. 3). Fig. 4: Connection of the computer Procedure - Start the measurect program. A virtual X-ray unit, rotation stage and Detector will be displayed on the screen. The green indication LED on the left of each components indicates that its presence has been detected (Fig. 5) - You can change the High Voltage and current of the X-ray tube in the corresponding input windows or manually on the unit. (Fig.5) - When clicking on the unit pictogram additional information concerning the unit can be retrieved( Fig.5) - The status pictogram indicate the status of the unit and can also be used to control the unit such as switching on and off the light or the X-rays (Fig5.) - The position of the XRIS and XRstage can be adjusted to its real position either by moving the XRIS pictogram or by filling in the correct value in the input window. (Fig.5) - The settings of the XRIS can be adjusted using the input windows. The exposure time controls the time between two frames are retrieved from the detector, the number of frames defines how many frames are averaged and with the binning mode the charge of neighbouring pixels is averaged to reduce the total amount of pixels in one frame. Fig. 5: Part of the user interface of the software P2550500 PHYWE Systeme GmbH & Co. KG All rights reserved 3

Principles of CT scan Experiment execution 1. Perform a CT scan Adjust the XRIS settings and X-ray unit settings according to fig 6 or load the configuration from the predefined CTO file 'Experiment 5' (see Fig 6). Overview of the settings of the XRIS and X- ray unit: - 35kV, 1.00mA - exposure time 0.5 sec - Number of frames: 1 - Binning mode 500x500 - SDD= 300, SOD= 250 Fig. 6: The settings for this experiment (left panel) and the method load and adjust the settings (right panel) Start a new experiment, give it a unique name and fill in your details (fig.6). Alternatively it is also possible to load this experiment with pre-recorded images and open this manual. The correct configuration will be loaded automatically as well but the functionalities of the software will be limited to avoid overwriting the existing data. Fig. 7 How to create a new or open an existing experiment 4 PHYWE Systeme GmbH & Co. KG All rights reserved P2550500

- Switch on the X-rays (fig. 8.1) and activate the 'Live view' (fig. 8.2). When the Live view is activated, every new image that is retrieved from the X-ray detector is displayed. The Detector exposure load bar (fig. 8.3) indicates the average degree of fill for each pixel. It is very important to remain below the maximal fill degree of the detector. Otherwise the detector will be saturated and won't work properly. If the saturation level is reached, the 'detector exposure' load bar will turn red. (see experiment 1 for more details) - Calibrate the detector by clicking on "Calibrate'(fig. 8.4). When the calibration is successfully performed, the indication LED (fig. 8.5) will turn green. The Load bar (fig. 8.3) will disappear and the Contrast/intensity cursor (fig. 8.6) will become available. (see experiment 1 for more info) - Place object XXXX on the sample stage and close the door. - Adjust SOD (fig. 8.7) and SDD (fig. 8.8) in the software according to the actual position. Fig. 8: Settings to set before start of a CT-scan, part 1 - Go from the "Live view page" to the "CT scanning page". The indication pictogram will turn blue when the page is activated. Fig. 9: CT scanning page P2550500 PHYWE Systeme GmbH & Co. KG All rights reserved 5

Principles of CT scan - Start a CT scan (fig. 10.1). During the CT scan the progress (fig. 10.2) as well as the remaining time (fig. 10.3) is displayed. The current image (fig. 10.4) being recorded is shown and the temporary result (fig. 10.5) is calculated during the scan. It is also possible to track the position of the rotation (fig. 10.6). When the scan is finished it is possible to replay the acquisition as a simulation (fig. 10.7). Fig. 10: Start a CT-scan When the CT scan is finished it is possible to proceed to the reconstruction. Go from the "CT scanning page" to the "Data reconstruction page". The indication pictogram will turn blue when the page is activated. Fig. 11: Data reconstruction page 6 PHYWE Systeme GmbH & Co. KG All rights reserved P2550500

2. Define the reconstruction parameters Prior to reconstructing the entire volume, it is important to define the correct reconstruction parameters. When the XRstage or the XRIS are moved, slight changes to the parameters will occur. For the best reconstructions it is advisable to test the parameters. - The effect of the reconstruction parameters can be tested with the test button (fig. 12.1). The result is displayed (fig. 12.2) for a certain slice (fig. 12.3) which corresponds to a certain line of the detector (fig. 12.4). The SOD and SDD (fig. 12.5) parameters should not be altered if they correspond to the physical position of the XRstage and XRIS. The most important parameter is the 'Centre of rotation' (fig. 12.6). Fig. 12: Data reconstruction page and buttons - The centre of rotation relates to physical rotation axis. Ideally, this is identical to the central column of pixels (250 for binning 500x500) but it might be different. Modify this value (fig. 12.6) and click on test (fig. 12.1), the adjusted result is shown (fig. 12.2). Change this value until the result looks sharp (fig.13). Fig. 13: Optimise the result by changing the Centre of rotation P2550500 PHYWE Systeme GmbH & Co. KG All rights reserved 7

Principles of CT scan - With the remaining parameters it is possible to optimise the quality of the results (see experiment 7). When the result looks satisfying press 'reconstruct' (fig. 12.7). The software will now reconstruct all slices of the recorded volume from top to bottom. the result are displayed (fig. 12.2) while it progresses (fig. 12.3 and fig. 12.4). 3. Investigate the reconstructed volume - When the reconstruction is finished it is possible to investigate the reconstructed volume. Go from the "Data reconstruction page" to the "Volume Viewer page". The indication pictogram will turn blue when the page is activated. Fig. 14: Volume viewer page - In the volume viewer the 3D dataset is displayed in 4 views. In the 'Axial', 'Saggital' and 'Coronal' view windows (fig. 15.1), three slices in different directions through the volume are shown according to the slicer indicator (fig. 15.3). When this indicator is moved around in either one of the three views, the corresponding slice is updated in the two other views. The fourth window (fig. 15.2) displays a 3D representation of the volume, by moving the 'projection angle' cursors (fig. 15.6), views from another direction are calculated. It is also possible to generate more elaborate 3D views with the third party freeware Volview by clicking on the Volview button (fig. 15.7). Fig. 15: Volume viewer page and buttons 8 PHYWE Systeme GmbH & Co. KG All rights reserved P2550500

Theory Detector saturation With digital X-ray imaging, X-ray photons that interact with the detector are converted to a digital signal. Such a digital detector is composed of a raster of pixels (picture elements) and each pixel can be considered as bucket. For each interaction of an X-ray photon with the detector, a series of electrons are produced in the pixel corresponding with the location of the photon interaction. These electrons are stored in the pixel, gradually filling up the bucket. After a set time interval, "exposure time", the electron content of the pixel is measured by emptying it. For the same intensity of X-ray's, a longer exposure time will results in a larger number of pixels in the bucket. Each digital detector has a limited bucket size which is called the 'full well capacity' of the detector. When this level off fill is reached, additional electrons are thrown away because the detector is saturated. A saturated detector will cause inconsistent measurements and has thus to be avoided. Detector calibration Each digital detector has a different and variable offset and pixel-specific output. During the calibration these variations will be measured and used in the subsequent imaging. Even without the X-rays on, the detector will generate a read-out value that is different from 0, called 'dark image'. This has several reasons from which the main reasons are an electronic offset and readout noise. When determining the beam intensity I 0, it is important to subtract this offset (I D ) from the measured read-out (I 0,M ). Another issue that exists, is that the sensitivity of every detector pixel is slightly different, resulting in a wide variation of I 0 values for every pixel. During calibration, these variations are recorded. After calibration, the Transmission value for every pixel (I) is recalculated based on the beam intensity of that pixel at that time (I M ), the beam intensity during calibration(i 0,M ) and the dark current intensity (I D ) during calibration. If the calibration was successfully performed, after calibration the images have grey-values between 0 and 1. Transmission and Attenuation In X-ray imaging, the transmission or attenuation of X-rays through a certain object are measured. Depending on the settings of the source, a beam with a certain intensity I 0 is measured by the detector when no object is placed between the source and the detector. When an object is placed in the path of the beam, this object will attenuate the beam so that the detector measures a smaller intensity I instead of I 0. The remaining intensity I compared to the original I 0 is called transmission (T), which is the opposite of the attenuation (A) of the object. For a calibrated detector, the beam intensity is rescaled to a value between 1 and 0. With T= 1 for the beam without an object in front of the detector (I 0 ). P2550500 PHYWE Systeme GmbH & Co. KG All rights reserved 9

Principles of CT scan CT scan and reconstruction When a CT scan is performed, several radiographies (projections) are recorded at different angles through the sample. By having data about the transmission of the object under different angles it is possible to calculate the µ value at each location in the sample. If we have for example a cylindrical object, one detector row will have a profile corresponding to picture xxx. 10 PHYWE Systeme GmbH & Co. KG All rights reserved P2550500

During the reconstruction process, the information of the two images are back-projected in a virtual array and the signal of each of the projections is summed. The more projections are taken, the more correct the result will be. However, it has been proven that this back-projection and summation is not analytically correct. Therefore the projection data first has to be filtered before being back-projected and summed. When the reconstruction of one detector row over 360 is successfully performed, the result is one virtual slice through the object. This slice is often saved as a single image and each pixels of the image actually represents one voxel (volume element) of the object. The grey-value of that voxel corresponds to the calculated µ-value of the sample. P2550500 PHYWE Systeme GmbH & Co. KG All rights reserved 11