Brief description of KR 15 controllers

Similar documents
Description of CERTO controller Standard

NX Series Inverters. HVAC Pocket Programming Guide

Commissioning and Maintenance of Power Factor Correction Systems

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

EN 50178, IEC

Operating Instructions

EFC 3600 Frequency converter for higher energy efficiency and improved process control

ENS31 Automatic Isolation Unit Product Description

The new Yaskawa Varispeed G7 Inverter

Industrial motor controller for brushed DC motors 24 VDC

Electronic Circuit Breaker ECONOMY REMOTE

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

BC145 SIGNAL ISOLATOR BOARD

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Electronic Circuit Breaker BASIC FIX

Brief Manual ACTIVE N3878

MultiMeter-Pocket CAT III 1000 V

ENS26 Automatic Isolation Unit Product Description

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Computer-14d - xx - 144a

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

KNX TH65-AP. Thermo-Hygrometer. Installation and Adjustment. Item number 70184

Industrial motor controller for brushed DC motors 12 VDC

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS...

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

TECHNICAL INFORMATION edition 1.02 FOR TRANSISTOR-FOUR-QUADRANT SERVO-AMPLIFIER SERIES MTR /5-15

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

SED2 variable speed drives Operating instructions. CM1U5192en Siemens Building Technologies HVAC Products

JBus/Modbus Communication Card

ISOMETER IRDH575. Approvals

Digital Function Generator

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Manual. Frequency Inverter. Series KFU 2- / 4- 0,55 to 3,0 kw 230 V KFU 2-0,55 to 132 kw 400 V KFU 4- KN E

Electronic Circuit Breaker BASIC SMART. - Number of available output channels: 2 / 4 / 8

3B SCIENTIFIC PHYSICS

Digital Electronic Thermostat With RF

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Room Temperature Controllers. for heating and cooling systems

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

S11 Adjustable Speed Drive Engineering Specification

THYFREC-VT230S 200V System 0.4 to 90kW 400V System 0.4 to 370kW INSTRUCTION MANUAL

Industrial motor controller for brushed DC motors 24 VDC

POWER SUPPLIES SPS1000 SERIES CIRCUIT DESCRIPTION AND OPERATING MANUAL

Power supply CP-E 24/0.75

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

[ 4 ] Using pulse train input (F01 = 12)

Room Temperature Controllers. for heating and cooling systems

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

Technical Documentation

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

USER S MANUAL. Customised to your machine Model: RX 200 V Class Three-Phase Input 0.4 to 55 kw 400 V Class Three-Phase Input 0.

PD2. Manual. Plug & Drive PD2 -1-

Fan and Pump AC Inverter

MS2109A AC/DC Clamp Meter. User Manual. Contents

LED Driver Compact dimming

13. Before making a service call Trip information and remedies

Frequency converter VAU 4/4 VAU(w) 7.5/3 VAU 11-22/3

smd frequency inverter

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Refrigeration Drive kw

LED Driver Linear / area dimming

S D 1 Operating Instructions

FREQUENCY-CONVERTER MFR 600A

CHAPTER 3 WIRING DANGER

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Operating Instructions

In the event of a failure, the inverter switches off and a fault code appears on the display.

RT-5005/5006/5007/5008

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Digital Interface Option "OPC-E1-DIO"

Power supply CP-T 48/20.0 Primary switch mode power supply

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Refrigeration Drive FC kw

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

Troubleshooting and Maintenance

External brake resistor AX2090-BW5x

SAFETY INSTRUCTIONS WARNING

Instruction manual for STA 1 sectional door operator

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Commissioning Instructions Rev. 03

Electronic circuit breaker ESS30-Sxxx-DC24V

Instruction Manual. General application Inverter. IMO idrive2 XKL

Goodrive 300 Inver ter

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

Power supply CP-T 48/5.0 Primary switch mode power supply

Table 6.1 Fault Code List Code indication (Note 3)

High Frequency Sinewave Guardian TM Filter

Transcription:

Brief description of KR 15 controllers E N E R G Y R E C O V E R Y Page 2 Page 4 Page 5 Page 6 Page 9 1. Function of the controller 2. Terminal connections 3. Technical data 4. Initial operation 5. Manual mode / external mode Supply air temperature regulation Page 20 Page 24 6. Trouble-shooting and fault messages 7. Safety and precautions

1. Function of the controller KR15 = 1500 Watt for wheel diameter from 5000 mm Special features: the controllers are usable worldwide all known regulations are taken into account by us for construction of the controller it is therefore the most modern generation of controllers by far the controllers are operated using only three buttons. The results and queries are displayed in a lighted, two-part display In hardwired condition, the controller is immediately ready to operate after turning on the mains voltage Faults are shown in the display 2

The latest processor technology CE - tested Housing IP 54 Short-circuit-proof output EN 55011 tested EN 61000-3 tested EN 61000-4-2 tested EN 61000-4-4 (Burst) tested EN 61000-4-5 (Surge) tested EN 61800-3 tested Every individual module is tested Detailed error message Thermal contact monitoring / PTC-resistor Two-row, colour, illuminated LCD display Operating report Start-up and discharge circuit Menu-controlled programming Optional accessories: Rotor control including function display Enthalpy sensor Clear LCD text display 3 languages GER/EN/NL Three-button operation External control signal processing Self-cleaning mode Priority speed adjustable 1 max. frequency Max. frequency adjustable 50-120 Hz Summer operating mode including function display Enthalpy comparison Temperature comparison Temperature changeover Supply air temperature regulation Sequential circuit including function display 0-10 V DC analogue output External fan output ThermasGard MWTM active supply air temperature sensor TPT 1000 temperature sensor 3

2. Terminals at the control units KR 15 A supply voltage of +24 volts DC is applied to terminals 4, 7 and 9. +15 volts DC is applied to terminal 11. +10 V DC is applied to terminals 16 and 19 for the enthalpy sensor. Changeover contacts shown in de-energised position 0-10V DC analogue output Dedusting input Priority/ summer speed bl br Jumper position Running control sch Control unit release 0-20 ma 4-20 ma Thermal contact/ resistor 0-10 V + 1 2 3 4 5 6 7 8 9 10 11 12 4 L1 N S1 S2 S3 PE PE PE PE U V W 13 14 15 16 17 18 19 20 21 22 23 24 +Ub 4-20 24V ma GND fresh air Exhaust air External control Supply air temp. temp. 10 V signal temp. sensor sensor reference sensor voltage Mains (230Volt) 50-60 Hz Error message: During operation S1 and S3 closed By occurring of defects or net failurel S2 and S3 closed 3-phase AC motor (3x230 Volt) in delta connection with standard motors 230/400 Volt N L1 30 31 32 33 34 35 36 37 38 39 40 41 External fan 230V max. 2A Operating notification + Summer operation Sequential circuit

Technical Data Controller typ KR 15 Output Fuse (internal) 1,5 kw Mains voltage 220-240 Volt / 50-60 Hz 1~ Weight Environmental temperature temperature adjustment range (only KR 4 Z / KR 7 Z) 16 A 8000 g from -10 C bis +40 C (for temperatures lower than 0 C it is necessary to switch on the mains voltage to the device without the motor running so that the controller can warm up) Air supply temperature regulation 10 C - 40 C /summer switchover 18 C - 42 C Other adjustment ranges must be specifically set Type of protection IP 54 Output frequency Frequency resolution Controller signal Fault message relay Motor connecting line Dimensions 0-120 Hz (factory setting 80 Hz) 0,08 Hz 0-10 V, 0-20 ma, 4-20 ma Potential-free changeover contact, 250 V AC, 1 A capacity The connecting line must be shielded; chokes should be provided for lengths of over 50 m. Please inquire! L=355 mm B=266 mm H=168 mm 5

4. Initial operation of the KR 15 controller The KR control unit is operated entirely by means of three buttons. Selections are made with the left ( ) and right ( ) button. The middle button ( ) is used to confirm the selection. If all three buttons are pressed at the same time, programming mode opens. Initial operation After connection to the mains voltage, the software version appears briefly in the display. K R _ V : x. x D / E Then for connected controller enabling: N o m. f r e q. : 0 0 H z A c t. f r e q. : 0 0 H z If the controller is not enabled, this appears: C o n t r. b l o c k e d! A c t. f r e q. : 0 0 H z H a r d w a r e e r r o r : E : 0 1! E r r o r! M o t o r H i g h t e m p e r a t u r e The system must be checked in accordance with the display. Start by pressing all three buttons: A message appears after about 2 seconds: 6

P l e a s e w a i t! The control unit takes you through the menu items when the motor has stopped. Moving through the menu items You have a choice of English, German or Dutch. Other menu languages are also available on request. The language is changed by means of the selection buttons. D e u t s c h E n g l i s h N e d e r l a n d s Confirm by pressing the Enter key ( ) The following will then appear: M a n u a l o p e r a t i o n E x t e r n a l D r i v e I n p u t t e m p e r a t u r e r e g u l a t o r As before, make your choice using the selection buttons and confirm with Enter ( ). In accordance with your choice, the control unit then leads you through the menu options for Manual operation, External control or Supply air temperature regulation, as described below. 7

Manual operation The following appears: M a n. f r e q u e n c y : 0 0 H z A frequency can be set using the selection button, which is used as soon as programming has been carried out and the start command has been given (using ). External control: The following appears: S t a r t p o i n t : 0 5 % The starting point can be set between 0-40% and relates to the control signal. With a setting of 10%, the control unit only reacts with a control signal of 1 volt. This prevents interference voltages leading to unintended operation of the control unit. Supply air temperature regulation After confirmation, the following menu appears: 8 S e t p o i n t : 1 6 C The supply air temperature required is set using this menu (between 0 C - 40 C). The PI control unit is activated for supply air temperature regulation This control maintains the target value set at a constant level. The Klingenburg temperature sensor with active output is required for this (ThermasGard MWTM):

: P - V e r s t ä r k u n g 0. 2-5. 0 0 1. 0 The amplification factor is set here. Attention: The value should not be set >1.0, as otherwise excessive under and over-oscillation may come about. I n t e g r a t i o n s z e i t 0. 1-9 9. 9 0 1. 0 s This affects the response time of the control system. The greater the time, the slower the response time. 5. Manual mode / External mode / Supply air temperature regulation When the Enter button M i n i m a l F r e q u e n c y M a x i m a l F r e q u e n c y is pressed, the following appears: 0 0 H z This menu can be used to set a minimum frequency of 0-10 Hz for purpose-built products, which is used when the control unit is released. If there is a control signal that requires a higher speed, the control unit adjusts to this requirement (standard setting 00 Hz). 8 0 H z The maximum final frequency that the control unit uses with a full control signal (10 volts DC) can be set using this menu from 50-120 Hz. at max. frequency, the rotor should rotate at approx. 10 revs./min the max. speed is determined by the design of the drive unit. Attention! All Klingenburg motors are suitable for frequencies up to 120 Hz. 9

The control unit has a programmable priority frequency, which is also controlled with the contact closed (terminal 4 and 5) and a 0-10 volt signal. This contact can easily be used to operate at frost speed, for example, or for summer operation. Example: Optional: Frost protection thermostat 3 4 5 4 5 Controller KR 15 N N Temp (+) <J <J Temp (-) Frost protection thermostat AC 250V 16 (4) A 10

This menu can be used to select the term that should appear on the display when the contact is activated: O p t i o n a l i n p u t : P r e c e d e n c e i n p u t O p t i o n a l i n p u t : F r o s t i n p u t O p t i o n a l i n p u t : S u m m e r i n p u t O p t i o n a l i n p u t : o f f! In the next menu, the frequency can be set in the range 0 - maximum frequency. For example: S o m m e r f r e q u e n c y 1 6 H z When the contact is closed, the term selected appears on the display during operation, together with the current frequency: F r o s t o p e r a t i o n A c t. f r e q. : 1 6 H z You can then select the summer function. If a summer circuit has not been ordered, you select: S u m m e r - f u n c t i o n o f f! 11

Otherwise, you set the summer circuit using the sensor supplied: S u m m e r - s w i t c h o v e r S u m m e r s w i t c h T e m p e r a t u r e c o m p. S u m m e r s w i t c h E n t h a l p y c o m p a r e If summer operation off or summer enthalpy comparison is selected, the switching point menu appears following confirmation with the Enter button ( ). If summer circuit or summer temperature comparison is selected and confirmed using the Enter button ( ) the following appears: N o m. f r e q. : 2 5 C. The temperature set activates summer operation and can be adjusted in 1 C steps in the range between 18-42 C When the reference temperature has been selected and confirmed with the Enter button ( ) the following menu appears: S w i t c h p o i n t : 5 0 % This is used to set the switching point of the sequential relay as a percentage of the max. frequency. Continuation of menu description on page 17. 12

Definition of terms Summer operation Your rotational heat exchanger can, of course, not only be used for heat recovery, but also as a cooler. If the exhaust air is colder than the external air in summer, the rotor can save valuable cooling power if it runs at maximum speed and pre-cools the external air. The KR 15 can check the summer conditions itself. Various versions are available for summer operation: Outside air sensor Supply air sensor Outside air Supply air Storage mass Extract air Exhaust air Exhaust air sensor 13

Enthalpy comparison switch If the external air enthalpy is higher than the exhaust air enthalpy, the rotor can use the exhaust air to cool the incoming external air. Two enthalpy sensors are required for the enthalpy comparison circuit. 16 17 18 19 20 21 3 4 1 3 4 1 ϕ ϕ ϑ ϑ 0... 85 J/kg 0... 85 J/kg External air enthalpy sensor Exhaust air enthalpy sensor Temperature comparison circuit If the exhaust air is colder than the external air, the rotor can use it to cool the incoming external air. Two temperature sensors are required for the temperature comparison circuit: Temperature changeover When a pre-determined external air temperature is exceeded, the rotor switches to cooling. For the summer circuit, a temperature sensor is required that measures the external temperature. A on the display indicates that summer operation has been activated. N o m. f r e q. : 8 0 H z A c t. f r e q. : 8 0 H z 16 17 18 19 20 21 1 2 1 2 ϑ ϑ External air sensor PT 1000 16 17 18 1 2 ϑ Exhaust air sensor PT 1000 External air sensor PT 1000 14

Supply air temperature regulation The supply air temperature required can be set between 0 C - 40 C. The active ThermasGard MWTM temperature sensor is required to determine the supply air temperature. The Premium control unit can regulate the supply air temperature required through the PI control. The display during supply air temperature regulation (sample display): Target-Temperature Actual-Temperature S T : 2 2 C I T x x C A c t. f r e q. : 8 0 H z on on on 1 2 3 internal sensor DIP switch measurement range changeover 0-50 C Min Max ±10K Offset -Ub GND Outlet 4-20 ma in C +Ub 24V 1 2 3 13 14 Contoller Inlet: 4-20mA +Ub 24V ThermasGard MWTM 15

Sequential circuit The sequential circuit has a potential-free changeover contact. As a result, a heating register can be fitted downstream, for example. The changeover point can be set between 5% and 100% of the maximum speed in 5% steps. A # in the centre of the display indicates that the sequential switch has been activated. When the sequential relay is activated, contacts 39 and 41 are closed. S o l l f r e q. : 8 0 H z # A c t. f r e q. : 8 0 H z 39 40 41 Sequential circuit 16 Summer operation Summer operation can be selected by means of a relay and is indicated by a. Contacts 36 / 38 are then connected. N o m. f r e q. : 8 0 H z A c t. f r e q. : 8 0 H z 0-10 V analogue output Here there is the option to access the current control signal in analogue form and to display it through the GLT (PLC) or to connect an external rev counter. 36 37 38 Summer operation 1 2 + GND Ua

Continuation of the menu description from page 11 The following then appears: C l e a n i n g a k t i v e 2 0 M i n bzw. C l e a n i n g o f f! The default value for cleaning mode is pre-set to 20 mins. It is essential that the control unit release is set throughout the operating period of the ventilation system and that it is controlled exclusively by means of the control signal or the keyboard. The cleaning mode ensures that the rotor moves at regular intervals by about half a revolution if no demands are made of it through the control signal or keyboard for more than 20 mins. The cleaning interval can be set to 40, 60, 80 or 100 minutes using the selection button. C l e a n i n g a k t i v e 1 0 0 M i n Confirm by pressing the Enter button ( ). 17

The rotation of the rotor can be monitored with the running control. If you have ordered the control unit with the Running Control option, select: R u n c o n t r o l a k t i v e! else R u n c o n t r o l o f f! The running control is switched on/off using the selection buttons, and confirmed using the Enter button ( ). During operation, the running control function is indicated by a black panel ( ) (>10Hz). N o m. f r e q. : 8 0 H z A c t. f r e q. : 8 0 H z The running control is not active with frequencies in the range 0-10 Hz. If the ventilation is unfavourable, air flowing in at an angle can cause unintended operation of the rotating air-to-air heat exchanger. The control unit has a DC brake that builds up a holding torque on the motor when the rotor is at a standstill. D C - B r a k e o f f D C - B r a k e o n The braking force can be set in % steps and should only be increased until the rotor stops moving. D C - b r a k. e f f e c t 1 5 % 18

In order for the changes entered to take effect, it is necessary to save them. S t o r e D a t a? Press the Enter button ( ) to save the values. s t o r e d! Pressing the selection buttons N o t s t o r e d! rejects the changes. The control unit returns to its previous setting. The following appears on the display in manual operation: H F : 0 0 H z I F : 0 0 H z Press the Enter button ( ) to start the control unit in manual operation. The following appears in external operation: S F : 0 0 H z I F : 0 0 H z 19

If a requirement is made by the control signal, the target frequency is displayed and the control unit goes into operation. If the following appears instead, for example: H a r d w a r e e r r o r : E : 0 1! check the fault using the list below. By simultaneously pressing, the error message is reset. C o n t r o l l e r r e s e t! 6. Troubleshooting table for the KR 15 control unit (No display visible) Test fuse / Check mains voltage Control unit not released. No error message! C o n t r. b l o c k e d A c t. f r e q. : 0 0 H z 20

Test thermal contact/ptc resistor The error message contact is triggered when the overheating fault occurs. Connection of thermal contact/ptc resistor to control unit. E r r o r! M o t o r H i g h t e m p e r a t u r e A supply voltage of 24V must be applied to terminals 4, 7 and 9 to ground (terminal 6 or 15). If no voltage is present, check control cable, remove any short circuit. Check rotor operation control sensor. E r r o r! R u n c o n t r o l e r r o r For operation with running control, check: For operation without running control: distance of proximity switch from rotor change programming of control unit Connection of proximity switch to the control unit (see description of Running Control) that V-belt has not jumped off V-belt tension check settings Although there is a control signal, the following appears: N o m. f r e q. : 0 0 H z A c t. f r e q. : 0 0 H z Position of the jumper matches description Is there a control signal? Connection of the control signal to the control unit (polarity) or M a n. f r e q. : A c t. f r e q. : 0 0 H z 0 0 H z The control unit has been set to manual operation 21

6. Error codes In addition to a fault in the running control and the motor overheating, the control unit recognises 7 different faults. These faults are indicated by means of a two-digit error code on the display: H a r d w a r e e r r o r : E : x x! 01 Overvoltage (motor / rotor blocked, short circuit between U, V, W) 05 Overload (controller / motor overloaded) 09 Mains under voltage 14 Earth fault 15 Mains overvoltage 21 Overtemperature in the power amplifier, environmental temperature too high, controller overloaded 99 Software error The control unit is ready for operation again when the fault has been rectified and the error has been acknowledged by disconnecting the mains voltage or pressing the three buttons simultaneously. 22 Attention! A restart mode integrated into the software means that the control unit does not report an error immediately in the event of overvoltage, undervoltage and overcurrent, but attempts to reset itself within

10 minutes. If it is reset within 10 mins., the control unit continues to work in normal mode. If the KR Premium is unable to reset itself as a result of a longer fault, the error message is triggered through the error message output after 10 mins. and the error code appears on the control unit display. Warning! This function brings about an automatic restart of the frequency inverter and thus of the drive in the event of a fault, once the set waiting period has passed - if there is still a start command present. It must be ensured that no one is put in danger in the event of a restart. Troubleshooting table for sensor operation The following troubleshooting table should also be considered when the sensor is in operation: Type of fault No supply air temperature regulation No enthalpy comparison No summer operation Checks: Check sensor, connection and programming 10 volts of DC voltage must be applied to terminals 16 and 19 against terminal 18 Check programming and connection If you have any questions about the control unit or its components, please always specify the device type and serial number of the rotary heat exchanger. 23

7. Safety and precautions Before installation and initial operation of the frequency converter, please read through the product handbook carefully and observe all warnings and safety precautions. Make sure that the product manual is easily reachable in the area of the frequency converter. Definition of tips: Warning! Failure to comply with this information could cause death, severe bodily injury or significant physical damage. Caution! Failure to comply with this information could cause minor bodily injury or physical damage. General: During operation it must be ensured that the mains voltage is constantly on. Warning! This frequency converter creates dangerous electrical voltage and controls dangerous rotating parts. Failure to comply with the information in this manual could cause death, severe bodily injury or significant physical damage. The installation, initial operation and maintenance of this drive may only be performed by expert staff that are well versed in the functionality and equipment as well as the machine. The device contains intermediate circuit capacitors that also carry out switchover of dangerously high voltages on the grid side. After switching off the voltage, wait at least 15 minutes before opening the device and working on it. Please be sure that no live parts are touched. The ground fault safety serves only as protection for the frequency converter and not as personal protection. In accordance with VDE 0160 (German abbreviation for the Association for Electrical, Electronic &Information Technologies), the three-phase frequency converter must not be operated on a leakage current circuit breaker, because a possible direct current component will reduce the sensitivity of the leakage current circuit breaker in the event of a fault. The provisions of VDE 0160 should be observed as protective measures. Ground the frequency converter to the connection provided for it. To avoid injury and damage, do not touch any parts within the housing not with hands or any kind of object when mains voltage is present or the intermediate circuit capacitor is not loaded. Do not work on wiring or test signals when mains voltage is present. 24

Pay special attention when the automatic restart is activated. To avoid injury from possible uncontrolled restart of the frequency converter after a power outage, install a switch element on the grid side that de-energises in a power outage and can only be turned on after return of voltage by manual confirmation (e.g., contactor, etc.). Ensure that the input voltage corresponds with the voltage listed on the label. Environmental influences such as high temperature and high humidity are to be avoided as well as dust, dirt and aggressive gases. The install location should be a well-ventilated location away from direct sunlight. Install the device on a non-flammable, vertical wall that does not transmit vibrations. Do not connect mains voltage to the output terminals U/T1, V/T2, W/T3. Please contact the motor or machine manufacturer if standard motors with a frequency of > 60 Hz will be operated. All frequency converters are tested for dielectric strength and insulation resistance measurements. Insulation resistance measurements, for example, in the course of inspection, must not be conducted between the power terminals and earth. Do not carry out insulation resistance measurements on the control terminals. During operation it must be ensured that the mains voltage is constantly on. Control commands and operating signals (such as start/stop) must only be implemented via the control terminals or the control panel and not by switching the mains supply or a motor contactor. Do not install capacitors or overvoltage arrestors in the motor lead. Caution! In order to guarantee that your Klingenburg frequency converter operates securely and reliably, all respective safety regulations, such as accident prevention regulations, VDE regulations, etc,. must be observed. As these regulations could contain different details within the German speaking areas, the user must observe the requirements that are valid for their area. Klingenburg GmbH cannot exonerate the user from the obligation to follow the most current safety regulations. The technical data and descriptions in these operating instructions are compiled according to the best of our knowledge and belief. Product improvements are constantly performed. For this reason, Klingenburg GmbH reserves the right to make such changes without prior notice. Despite the careful creation of these instructions, Klingenburg GmbH cannot be held liable for errors or damage which arise from use of this manual. 25

You can enter the values you have set here: Mode of operation Manual set point Starting point Min. frequency Max. frequency Priority input Cleaning mode Running control DC brake Braking torque Supply air temp. [ C] P factor I time 26

Maintenance notes (e.g. V-belt tension set to:) 27

E N E R G Y R E C O V E R Y Klingenburg GmbH Boystraße 115 D-45968 Gladbeck, Germany Tel.: +49-20 43-96 36-0 Fax: +49-20 43-7 23 62 E-mail: klingenburg@klingenburg.de www.klingenburg.de KR 15 eng 110413