SPECIFICATIONS Product Features: Input voltage Range:100~277VAC; Power Factor up to 0.99; Efficiency up to 88%; PSR topology, high reliability; Meet UL8750 UL1310 CB CE; International Protection:IP66; High power density, Subminiaturization; 3 years warranty; Class 2 and SELV Model List: Model UL/CSA TUV-CE CQC Output Output Output Voltage Current Power Efficiency FS24W-12C2000 N Y N 8-12V 2000mA 24W 83% FS24W-16C1500 N Y N 10-16V 1500mA 24W 84% FS24W-20C1200 N Y N 13-20V 1200mA 24W 85% FS24W-24C1000 Y Y N 14-24V 1000mA 24W 86% FS24W-24C0900 Y N N 14-24V 900mA 21.6W 87% FS24W-28C0850 N Y N 16-28V 850mA 23.8W 87% FS24W-36C0680 Y Y N 20-36V 680mA 24.48W 88% FS24W-36C0650 Y N N 20-36V 650mA 23.4W 88% FS24W-48C0500 Y Y N 26-48V 500mA 24W 89% Note:The above is the standard model. Can be customized. Revision History: Change Date Rev: Before Change After Change 2013/8/30 1.0 / Datasheets Release
Electrical Specifications: 1. Input Specifications Input voltage Range 90 305 Vac Input Frequency Range 47 63 HZ Input AC Current 100%Load at 115V Input 0.3 A Inrush Current 100%Load at 230V Input 20 A Power Factor 100%Load at100-240v Input 0.9 THD 100%Load at100-240v Input 20% 2. Output Specifications Output Voltage 100-277V Input Constant current mod 60% 120% Output Current 100-277V Input 100% Line Regulation 100%Load at100-277v Input -3% +3% Load Regulation 100%Load at100-277v Input -5% +5% Starup Overshoot Current 100%Load 10% Ripple&noise 100%Load 10% Efficiency(1) 100%Load at100v Input 87% Turn-on Delay Time 100%Load at100v Input 600 1500 ms Stop Hold Time 100%Load 10 ms 3. Environment Features Operating TEMP. range(2) -30 70 Storage TEMP. Range -40 85 International Protection: IP66 Case TEMP.(Tc)(3) When Ta=50 85 Notes: 1, Test sample model:fs24w-36c0680 2, Refer to operating temperature derating curve. 3, Refer to mechanical 4. Safety Features Leakage Current Iput TO Output 25 70%RH 0.5 ma Insulation Voltage Iput TO Output 25 70%RH 3750 Vac Insulation Resistance Iput TO Output(500VDC 25 70%RH) 100 MΩ
5. Protection Functions Parameter Notes Protection Performance Over Voltage Protection When the load voltage exceeds 1.2 times the rated voltage Shutdown and reboot Over Load Protection When the load power exceeds 1.2 times the rated power Shutdown and reboot Short Circuit Protection When the output is shorted Shutdown and reboot Over Temperature ProtectionWhen the case temperature is over 100 Shutdown 6. Product Specifications Parameter Specifications Notes Size Weight Color MTBF 88*38*24mm 133g White 200000Hours 80%load and 25 ambient temperature (MIL-HDBK-217F) Life Time When Tc<60 Life Time>90000Hours Refer to Life Time curve 7. Safety Certification Safety Category Standard UL/CUL UL8750,UL1310,CAN/CSA C22.2 No.223 M91,CAN/CSA-C22.2 No.250.13-12 CE EN61347-1:2008+A1,EN61347-2-13:2006,EN62493:2010 CB IEC61347-1:2007+A1,IEC61347-2-13:2006 8. Electromagnetic Compatibility EMI EN55015B EN61000-3-2 EN61000-3-3 FCC Part 15 EMS EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 EN61547 Notes Conducted Emission Test & Radiated Emission Test Harmonic current emissions Voltage fluctuations & flicker ANSI C63.4:2009 Class B Notes Electrostatic Discharge (ESD): 8 kv air discharge, 4 kv contact discharge Radio-Frequency Electromagnetic Field Susceptibility Test-RS Electrical Fast Transient / Burst-EFT: Level 3,Criteria A Surge Immunity Test: AC Power Line: Line to Line 1 kv Conducted Radio Frequency Disturbances Test-CS Power Frequency Magnetic Field Test Voltage Dips Electromagnetic Immunity Requirements Applies To Lighting Equipment
Characteristic Curve: Notes: Test sample model: FS24W-36C0680
Mechanical: Parameter Cable Specifications AC L UL1015 18AWG White Overall Length 150mm Tinning10mm AC N UL1015 18AWG Black Overall Length 150mm Tinning10mm DC + UL1569 18AWG Red Overall Length 150mm Tinning10mm DC - UL1569 18AWG Black Overall Length 150mm Tinning10mm
Applications: 1,Range of applications: Applies to all LED light source. 2,Application diagram: 3,Application Notes: 1, LED module the maximum voltage value must be less than the maximum output voltage of the power supply; 2, LED module rated current value must be greater than or equal to the rated current of the power supply; 3, Whatever the application, the ambient temperature of the power supply must be less than the rated maximum ambient temperature, the rational design of LED terminal equipment can maximize the life of the power 4, The power supply of the best efficiency value at 70% -100% load range, reasonable design LED module, to maximize the utilization of the power supply; 5, The power supply cannot be installed in flooded environment; 6, Outdoor applications cable connector must make good contact and prevent the oxidation; 7, The power supply is considered a component used in conjunction with the terminal equipment, EMC effect by the entire device, terminal equipment manufacturers are required to complete installation of EMC reconfirmation.