Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Similar documents
Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Introduction. Part 1. Introduction...2

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer. Application Note

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Keysight Technologies N432A Thermistor Power Meter. Data Sheet

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies USB Preamplifiers

Keysight Technologies 87222C/D/E Coaxial Transfer Switches

Keysight Technologies Migrating Balanced Measurements from the

The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 khz a capability typically found

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Measuring Power BJT Electrical Characteristics using the B1505A

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies

Keysight Technologies Z9070B Wideband Signal Analysis Solution. Technical Overview

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies N4916B De-emphasis Signal Converter

Keysight Technologies U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies N432A Thermistor Power Meter. Data Sheet

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies N4985A System Amplifiers

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Agilent N432A Thermistor Power Meter

Keysight Technologies Noise Figure X-Series Measurement Application N9069A & W9069A

Keysight Technologies Enhancing Measurement Performance for the Testing of Wideband MIMO Signals

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies Minimum Required Sample Rate for a 1-GHz Bandwidth Oscilloscope

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies N9063A & W9063A Analog Demodulation

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies Generating and Applying High-Power Output Signals

Introduction. Part 1. Introduction...2

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies How to Select the Right Current Probe. Application Note

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies Oscilloscope Probe Loading Experiment

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Power of Impedance Analyzer

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies mm-wave Source Modules from OML, Inc. for PSG Signal Generators. Technical Overview

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies A Flexible Testbed to Evaluate Potential Co-Existence Issues Between Radar and Wireless

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Agilent 2-Port and 4-Port PNA-X Network Analyzer

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight N9310A RF Signal Generator

Transcription:

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter Application Note

Introduction This application note explains the application procedure for using the N432A with the thermistor mount to measure the power reference source of power meters. The first part of the article focuses on the fundamentals of the power reference measurement requirements. The second section provides step-by-step instructions for performing the measurement using the N432A thermistor power meter. The third part includes the measurement uncertainty or expected measurement error, which is a basic statistical method of obtaining the total measurement uncertainty. The final part of the article covers a brief overview of the new Keysight Technologies, Inc. N432A thermistor power meter. Why Calibrate the Power Reference? Measuring or verifying the 1 mw (0 dbm) 50 MHz power reference source is one of the key tasks when performing the annual service or calibration on RF power meters. In calibration laboratories or service facilities, engineers and technicians calibrate and measure the power reference in order to maintain the power meter s measurement accuracy. In other words, maintaining the accuracy and traceability of the power reference indirectly minimize the power meter s measurement uncertainty. All existing RF power meters, such as the Keysight Technologies EPM-P E4416/17A, EPM E4418/19B, and the N1913/14A, have a power reference source (also known as a reference calibrator) that has a typical specification of 1 mw ±0.5% (23 ±3 C) or ±0.9% (0 to 55 C) (see Figure 1). Figure 1. 1 mw (0 dbm) 50 MHz power reference calibrator on power meters When measuring RF power, the calibration factor corrections done within the power meter (connected with a power sensor) are referenced to this 1 mw 50 MHz source. That is why prior to performing any direct power measurement using the power meter and sensor, it is necessary to zero and calibrate the meter to ensure the power measurement will be accurate.

03 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note Why Calibrate the Power Reference? (continued) As shown in the Figure 2, the power reference measurement is traceable to the National Standard (NIST). In order to obtain an accurate measurement when calibrating the meter s power reference, the use of a thermistor power meter such as the Keysight Technologies N432A is recommended. This is because this power meter combined with the thermistor mount has a very low uncertainty. We shall elaborate more on the measurement uncertainty in the later portion of this application note. National standard (NIST) microcalorimeter Traceability Transfer standard (NIST) bolometer Reference or working standard (calibration/standard labs instruments manufacturer) N432A + 478A N432A + 8478B End user power meters E4416/17A, E4418/19B N1911/12/13/14A Figure 2. NIST traceability of RF power measurement Measurement setup for the 1 mw 50 MHz power reference The typical measurement setup for testing the reference calibrators uses the N432A thermistor power meter with a Keysight 3458A 8.5 digit digital multimeter (DMM) as shown in Figure 3. This setup is widely used by calibration and metrology labs because the 3458A DMM provides superior accuracy and traceability. However, depending on the measurement accuracy needed, the 3458A DMM is optional. The N432A power meter has a built-in internal voltmeter to convert the DC bridge voltages to watts (or dbm). Optional Vcomp (+) N432A 3458A Vrf (-) Cable adaptor N4998A Thermistor power meter & sensor 478A or 8478B Power meter under test Figure 3. 1 mw 50 MHz power reference measurement setup

04 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note DC bridge V comp and V RF measurement The N432A has an internal digitizer that resembles a built-in digital voltmeter (DVM), providing an equivalent 6.5 digit DVM voltage measurement on the internal DC bridges. A simplified block diagram of the internal N432A is shown in Figure 4. There are two DC bridge circuits, the first bridge is called RF bridge and detects the RF power. The second circuit is called the compensated bridge and compensates for environmental temperature drift. The readings of the ambient thermistor are used to correct the readings of the sensor thermistor. This dual bridge operation is called compensated mode. R user 100 or 200 Ω BIAS driving current 1kΩ BNC connectors at the rear panel Thermistor mount 478A or 8478B R T 1kΩ + Differential amplifier Signal conditioning ADC Figure 4. N432A DC Wheatstone self balancing bridge The impact of this built-in DVM improves the overall power measurement of the meter. The resulting benefits of this feature are that an external DVM is not required for the power measurement and that the overall accuracy of the power measurement is better than that obtained using only the 432A analog thermistor power meter. Figure 5 shows the voltage measurements panel in N432A. Figure 5. N432A voltage measurement display However, both V COMP and V RF are available at the two BNC connectors located at the rear panel of the N432A. This is similar to the legacy 432A power meter, and these voltages will be measured by the external DMM.

05 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note Special thermistor mount 478A-H75/H76 or 8478-H01 Optional specialty thermistor mounts (Figure 6) are used when performing power reference measurement because these mounts provide the lowest mismatch or standing wave ratio (SWR) at 50 MHz. The 478A Option H75 or H76, and 8478B Option H01 provide only 1.05 of SWR at 50 MHz, compare to normal mounts which typically have a SWR of 1.3. The reason for using these special, factory-tuned low SWR at 50 MHz is to reduce the mismatch measurement uncertainty when these mounts are connected to the reference calibrator of the power meters. From past experience, mismatch errors can significantly impact the overall measurement uncertainty. Figure 6. Special-tuned low SWR at 50 MHz thermistor mounts Step-by-Step Power Reference Measurement Procedures 1. Connect the equipment as shown in Figure 2. 2. Set the 3458A DMM to measure the DCV. 3. Ensure that the N432A and the power meter under test have been powered on for at least 30 minutes before continuing. (This is the recommended warm up time.) 4. Zero the N432A making sure that the power reference of the power meter under test is turned off. 5. Round the DMM reading to two decimal places and record this reading as V 0. This is the voltage measured between the V COMP and V RF connectors when no RF power is applied (the calibrator reference is turned off). 6. Turn-on the power reference on the power meter under test. 7. Round the DMM reading to two decimal places and record this reading as V 1 (the reading is typically about 80 mv). In other words, V 1 is the voltage measured between the V COMP and V RF connectors when the calibrator reference power is turned on. 8. Disconnect the DMM negative input lead from the V RF connector on the N432A and connect it to the N432A chassis ground. 9. Record the DMM reading result as V comp (typically this is about 4.8 V). V COMP is the voltage of the temperature compensated bridge. 10. Calculate the power reference oscillator power using Equation 1. The value for R can be typically set as 200 Ω. The CF is the calibration factor for the thermistor mount at 50 MHz. It is typically set as 99%. 11. The expected power measurement results (calculated) should be 1 mw ±0.9%. P = 2V comp (V 1 V 0 ) + V 2 0 V 2 1 4 R CF Equation 1

06 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note Power Measurement Uncertainty Power measurement uncertainty equation The measurement uncertainty for measuring the 1 mw reference calibrators is based on the power measurement shown in Equation 2. The equation is a modified version of Equation 1 and includes the mismatch term (M) to account for the imperfect power transfer from the power reference (power meter under test) to the thermistor mount. P = 2V comp (V 1 V 0 ) + V 2 0 V 2 1 4 R CF M Equation 2 M is the maximum (worst case) mismatch uncertainty between the calibrator reference to be measured and the thermistor mounts connector. It takes the form (1±2G s x G d ), where G s is the power reference reflection coefficient and G d is thermistor mount reflection coefficient. N432A power measurement uncertainty model assessment Typically the power measurement uncertainty assessment is obtained using the uncertainty tabulated budget model. The assessment starts by collecting all the uncertainty contributors, in this case they are V COMP, V, V, R, CF, and M. The root sum square (RSS) 0 1 of the total uncertainty contributors is then calculated. This is called the RSS method. Table 1 shows an example of the 1 mw power reference measurement uncertainty based on set up shown in Figure 2. The content has been simplified and only shows the individual contributions of each parameter in Equation 2. Refer to Keysight s application note Keysight Fundamentals of RF and Microwave Power Measurements, application note 1449-3, literature number 5989-7083EN for details. The result shows that the total measurement uncertainty using N432A thermistor power meter and sensor is 0.46%. Table 1. Measurement uncertainty budget table (with 3458A) Uncertainty contributors Units Value ± Limits Uncertainty contributed (standard uncertainty x sensitivity) Voltage measurement for Vcomp V 4.8 0.00003845 4.67 x 10-9 Voltage measurement for V1 V 0.080 0.00000098 6.77 x 10-9 Voltage measurement for V0 V 0.0023 0.00000032 2.23 x 10-9 Bridge resistance measurement, R Ω 200 0.00250 7.35 x 10-9 CF (calibration factor) Ratio 0.99 0.004 (calibrated by standard lab) 2.06 x 10-6 M (mismatch uncertainty) Ratio 1.00 0.00142 (2 x G s x G d) 1.02 x 10-6 Root sum square 2.29 x 10-6 Coverage factor, k = 2 for 95% confidence 2 Expanded uncertainty 4.59 x 10-6 Expanded uncertainty in % for 1 mw 0.4597

07 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note N432A power measurement uncertainty model assessment (continued) As mentioned earlier, the measurement setup shown in Figure 2 can be simplified by eliminating the use of the 3458A. The voltage measurements (V COMP, V, and V ) will rely 0 1 on the internal ADC measurement accuracy of the N432A. Hence the measurement uncertainty assessment will yield different results. Table 2 shows an example for such a scenario and the results show a very small difference from the measurement uncertainty model with the 3458A DMM. The improvement of the voltage measurement from 6.5 digit (N432A internal) to 8.5 digit (3458A) external yield is a non-significant improvement in terms of the measurement uncertainty. More importantly, in both cases, the CF and mismatch uncertainty always dominants the total uncertainty. Table 2. Measurement uncertainty budget table (standalone N432A) Uncertainty contributors Units Value ± Limits Uncertainty contributed (standard uncertainty x sensitivity) Voltage measurement for Vcomp V 4.78 0.00066730 8.14 x 10-8 Voltage measurement for V1 V 0.081 0.00001043 7.15 x 10-8 Voltage measurement for V0 V 0.0023 0.00000709 4.95 x 10-8 Bridge resistance measurement, R Ω 200 0.00250 7.35 x 10-9 CF (calibration factor) Ratio 0.99 0.004 (calibrated by standard lab) 2.06 x 10-6 M (mismatch uncertainty) Ratio 1.00 0.00142 (2 x G s x G d) 1.02 x 10-6 Root sum square 2.31 x 10-6 Coverage factor, k = 2 for 95% confidence 2 Expanded uncertainty 4.62 x 10-6 Expanded uncertainty in % for 1 mw 0.4620

08 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note Brief Introduction to the N432A Thermistor Power Meter The N432A meter is the replacement model for the 432A power meter and includes enhancements and exciting features. This N432A thermistor power meter works perfectly with Keysight temperature-compensated thermistor mount sensors (478A and 8478B). Together with these sensors, the meter measures RF power from 30 to +10 dbm and cover the frequency range from 100 khz to 18 GHz. It is the highest-accuracy power meter offered by Keysight. The N432A operates on the basis of a DC self-balancing Wheatstone bridge which shall be elaborated on later. Hence, the N432A is the only RF power meter with a DC substitution measurement, enabling it to convert RF power to a DC measurement such as voltage (V) and resistance (Ω). This ability is why the meter is widely used in metrology and calibration labs worldwide to calibrate power meters and sensors, and for any application which requires accurate RF power measurement. In addition to the external V COMP and V RF connectors at the rear panel, the new N432A has a built-in digital voltmeter (DVM). It is simply an internal ADC circuit that digitizes the V COMP and V RF voltage measurements and displays the results on the front of the meter. The users can select which measurement results to display, ranging from power measurement (dbm, watts) to the voltage measurements (V RF, V COMPENSATED, V 0 and V 1 ). This whole digitization resembles a digital voltmeter (DVM) that s built inside the power meter, giving equivalent 6.5 digit DVM voltage measurement results.

09 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note Conclusion Over the years, thermistor-based power meters have been used to measure and calibrate the 1 mw 50 MHz power reference calibrator of RF power meters because of their accuracy, reliability, and traceability to standard labs. As shown in the power measurement uncertainty examples, these power meters (using a special thermistor mount) provide a very low uncertainty which is around 0.5%. The use of an external 3458A DMM to measure the V COMP, V, and V directly from the 0 1 N432A power meter is a preferable setup for calibration and the standard lab because it is a more direct, traceable method and provides greater accuracy. From the two examples shown, it is clear that the two most significant contributors are the mismatch error and the CF uncertainty. Hence to maintain low mismatch uncertainty, a super low reflection coefficient thermistor sensor is to be used. To reduce CF uncertainty, make sure the sensor is calibrated at the standard metrology labs to maintain consistency, low uncertainty, and minimum drift. Reference 1. Radio Frequency & Microwave Power Measurement, Alan Fantom, IEEE, ISBN: 0 86341 120 7, 1990 2. Keysight Fundamentals of RF and Microwave Power Measurements, application note 1449-3, literature number 5989-7083EN 3. Keysight N432A Thermistor Power Meter, technical overview, literature number 5990-6168EN 4. Measuring RF Power, Joe Carr, Electronic World, November 1999 5. Keysight EPM-P E4416/17A, service manual, part number E4416-90014 6. Keysight N432A Thermistor Power Meter, user manual, part number N432A-90002

10 Keysight 1mW 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter - Application Note mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 www.keysight.com/find/n432a For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) This information is subject to change without notice. Keysight Technologies, 2011-2014 Published in USA, August 1, 2014 5990-9078EN www.keysight.com