PULSE OXIMETRY SIMULATOR

Similar documents
ELECTROSURGICAL UNIT ANALYZER

ECG PATIENT SIMULATOR FIVE LEAD

ECG PATIENT SIMULATOR SIX LEAD

MULTI-PARAMETER PATIENT SIMULATOR

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

2015 RIGOL TECHNOLOGIES, INC.

200Amp AC Clamp Meter + NCV Model MA250

MaxLite Linear Strip ECO Series

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

PCO-7114 Laser Diode Driver Module Operation Manual

INSTRUCTION MANUAL INF Fax: (503)

User Guide. Digital AC/DC Clamp Meter Model 38394

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

User s Guide. Digital AC/DC Clamp Meter Model 38394

Radio Remote(s) (Installation Manual)

TK 100 Probe Calibrator. Instruction Manual

Operator s Manual. PP016 Passive Probe

User s Guide. 400A AC/DC Clamp Meter. Model MA220

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

Operator s Manual. PP022 Passive Probe

Planishing hammer stand For use with SKU Planishing hammer

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model 113 Scintillation Preamplifier Operating and Service Manual

CRD 410 MANUAL FITTING INSERTER

Owner s Manual & Safety Instructions

Operator s Manual. PP017 and PP018 Passive Probes

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

One Shelf, Wall Mounted A/V Component Stand Installation Guide Model: EX101SS

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

TA MHz oscilloscope probe TA MHz oscilloscope probe

12B/18 MultiMeter Instruction Sheet

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Tilting & Swiveling Flat Panel Wall Mount Installation Guide Model: AXS2040

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

User s Guide. Agilent 16441A R-Box. Agilent Part No Printed in Japan January Edition 4

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

INSTRUCTION MANUAL LKG

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

Flat Sample Holder Part Number

VT1586A Rack Mount Terminal Panel Installation and User s Manual

A Channel Amplifier

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

Keychain Radio Remote Control System

A-16D A-Net Distributor

MaxLite LED Self-Driven LiteBars

PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT. HRRS 5kV AND 10kV SERIES. High Resistance, 5kV and 10kV Decade Substituter User and Service Manual

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

20 Ton HYDRAULIC SHOP PRESS

Glass Electrode Meter

Autoranging Multimeter Extech EX503

Instruction Sheet D-CPU. Secure CPU Holder

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Earth Fault Indicator EFI-BLZ-50 User Manual

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

OVA-50 Optical Variable Attenuator User s Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Model 9305 Fast Preamplifier Operating and Service Manual

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

MODEL 3810/2 Line Impedance Stabilization Network

Inline Antenna Signal Amplifier

Using the USB Output Port to Charge a Device

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

INTEGRATED HYBRID TUBE AMPLIFIER VT Model HYBRID TUBE AMPLIFIER

STAFF User Manual. Manual Part #

Instruction Sheet SNE SERIES. Cable Chase

Models 2230 and 2240

Broadband Step-Up Transformer. User Manual

Digi-Stop. User Manual for: Digi-Stop. Digital Readout Firmware version d & Higher

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

Radio Remote Controls Manual K Series

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Models 2130 and 2140

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

Models 2130 and 2140

ITEM Pipe Thread Kit (10 Piece Set - 7 Dies) Assembly and Operating Instructions

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

BC145 SIGNAL ISOLATOR BOARD

Models 2030 and 2040

SPM-50 RF Spectrum Power Meter PC Software User Manual

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

AMP-13 OPERATOR S MANUAL

MANUAL METAL SHRINKER/STRETCHER

UNCONTROLLED WHEN PRINTED

INSTRUCTION MANUAL T100 MINI-MIST DELUXE TANNING SYSTEM. (Not Suitable for Continuous Use)

Transcription:

PULSE OXIMETRY SIMULATOR SPO-2000 SYSTEM USER MANUAL

BC BIOMEDICAL SPO-2000 SYSTEM TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 KEYS... 3 LED INDICATORS... 4 OPERATIONS... 5 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS... 7 NOTES... 8 i

WARNING - USERS The SPO-2000 System is for use by skilled technical personnel only. WARNING - USE The SPO-2000 System is intended for testing only and should never be used in diagnostics, treatment or any other capacity where it would come in contact with a patient. WARNING - MODIFICATIONS The SPO-2000 System is intended for use within the published specifications. Any application beyond these specifications or any unauthorized user modifications may result in hazards or improper operation. WARNING LIQUIDS Do not submerge or spill liquids on the SPO-2000 System. Do not operate the SPO-2000 System if internal components not intended for use with fluids may have been exposed to fluid, as the internal leakage may have caused corrosion and be a potential hazard. CAUTION - CLEANING Do not immerse. The SPO-2000 System should be cleaned by wiping gently with a damp, lint-free cloth. A mild detergent can be used if desired. CAUTION - SERVICE The SPO-2000 System is intended to be serviced only by authorized service personnel. Troubleshooting and service procedures should only be performed by qualified technical personnel. ii

CAUTION - ENVIRONMENT Exposure to environmental conditions outside the specifications can adversely affect the performance of the SPO-2000 System. If the SPO-2000 System is outside of Operating specifications, allow it to acclimate to specified conditions for at least 30 minutes before attempting to operate it. CAUTION - INSPECTION The SPO-2000 System should be inspected before each use for wear and should be serviced if any parts are in question. NOTICE SYMBOLS Symbol Description Center Negative NOTICE ABBREVIATIONS BPM Beats Per Minute C Celsius Degree(s) DUT Device Under Test F Fahrenheit kg kilogram(s) LED Light Emitting Diode ma milliampere(s) mm millimeter(s) Lbs pounds USA United States of America VDC Volts Direct Current iii

NOTICE DISCLAIMER BC GROUP INTERNATIONAL, INC. WILL NOT BE RESPONSIBLE FOR ANY INJURIES SUSTAINED DUE TO UNAUTHORIZED EQUIPMENT MODIFICATIONS OR APPLICATION OF EQUIPMENT OUTSIDE OF THE PUBLISHED INTENDED USE AND SPECIFICATIONS. NOTICE DISCLAIMER BC GROUP INTERNATIONAL, INC. RESERVES THE RIGHT TO MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT ANY TIME, WITHOUT NOTICE, IN ORDER TO IMPROVE THE DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST POSSIBLE PRODUCT. THE INFORMATION IN THIS MANUAL HAS BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE ACCURATE. HOWEVER, NO RESPONSIBILITY IS ASSUMED FOR INACCURACIES. NOTICE CONTACT INFORMATION BC BIOMEDICAL BC GROUP INTERNATIONAL, INC. 3081 ELM POINT INDUSTRIAL DRIVE ST. CHARLES, MO 63301 USA 1-800-242-8428 1-314-638-3800 www.bcgroupintl.com sales@bcgroupintl.com SPO-2000 System User Manual Copyright 2012 www.bcgroupintl.com Made in the USA 04/12 Rev 04 iv

BC BIOMEDICAL SPO-2000 SYSTEM PULSE OXIMETRY SIMULATOR SYSTEM The SPO-2000 System is used to verify the operation of Pulse Oximeters. The SPO-2000 System is comprised of the SPO-2000 Base Unit and a FingerSim simulated finger, available in three different SpO 2 saturation levels. The FingerSim is inserted into the SPO-2000 Base Unit, which then adds calibrated pulse rates to the functionality of the FingerSim. The following are highlights of some of the main features. SPO-2000 SYSTEM (BASIC FEATURES): SIX CALIBRATED SIMULATOR PULSE RATES: 30, 60, 90, 120, 150, and 180 BPM LED INDICATION OF SELECTED PULSE RATE STANDBY MODE AVAILABLE MODELS: The SPO-2000 Base Unit plus one or more FingerSims are required in order to verify the operation of Pulse Oximeters. SPO-2000 FingerSim KIT SIMULATOR BASE UNIT COMPLETE STARTER KIT (INCLUDES 80%, 90% AND 97% FingerSims, FingerSim HOLDER, AND CARRYING CASE) FingerSim SET REPLACEMENT KIT (80%, 90% AND 97% FingerSims ONLY) STANDARD ACCESSORIES: BC20-00431 (OR) BC20-40614 110V AC POWER ADAPTER (US) 220V AC POWER ADAPTER (EURO) OPTIONAL ACCESSORIES: BC20-40110 CARRYING CASE FOR SPO-2000 BASE UNIT, FingerSims & ACCESSORIES 1

LAYOUT This section looks at the layout of the SPO-2000 Base Unit and gives descriptions of the elements that are present. Connector for Power Adapter 2 Light Touch Keys ACTIVE/STANDBY for enabling/disabling Pulse Simulation SCROLL for selecting the Pulse Simulation rate. ON/OFF Switch FingerSim Receptacle (NOTE FingerSim is shown installed for reference). 6 LED indicators for Indicating Pulse Simulation rate (BPM) 180 BPM 150 BPM 120 BPM 90 BPM 60 BPM 30 BPM 2 LEDs for Indicating Status ACTIVE for showing when Pulse Simulation is active. POWER for showing when the SPO-2000 Base Unit is On. 2

KEYS 2 soft touch keys are provided for Base Unit operation: This key is used to turn the SPO-2000 Base Unit Pulse Simulation ON and OFF. This key is used to select the desired Pulse Simulation rate. 3

LED INDICATORS There are eight LEDs to indicate the status of the Base Unit. They are marked POWER, ACTIVE, 30, 60, 90, 120, 150, AND 180. POWER This LED indicates that the Base Unit power switch is turned ON and the onboard power supply is functioning properly. ACTIVE This LED indicates that the Base Unit is in the ACTIVE mode, meaning Pulse Simulation is activated. STANDBY mode is indicated by an active POWER LED and inactive ACTIVE LED. 30 This LED indicates that the currently selected Pulse Simulation rate is 30 BPM. NOTE: This is the default Pulse Simulation rate when the Base Unit is first powered. 60 This LED indicates that the currently selected Pulse Simulation rate is 60 BPM. 90 This LED indicates that the currently selected Pulse Simulation rate is 90 BPM. 120 This LED indicates that the currently selected Pulse Simulation rate is 120 BPM. 150 This LED indicates that the currently selected Pulse Simulation rate is 150 BPM. 180 This LED indicates that the currently selected Pulse Simulation rate is 180 BPM. 4

OPERATIONS The SPO-2000 Base Unit will start up in the STANDBY mode with a selected Pulse Simulation rate of 30 BPM by default. Insert the desired FingerSim into the rectangular SPO-2000 FingerSim receptacle. NOTE: It is recommended that the FingerSim be inserted with the printed side down to minimize wear on the printing by the mechanism inside the SPO-2000 Base Unit. Use the key to select the desired Pulse Simulation rate. Pulse Simulation is enabled by depressing the key. The ACTIVE LED will turn on and the FingerSim will pulse at the desired rate. The Pulse Simulation rate can be changed by depressing the ACTIVE or STANDBY mode. key, in either the Connect the finger probe of the DUT being tested to the FingerSim. For tidiness, route the probe s cable underneath the SPO-2000 Base Unit. Pulse Simulation is disabled by depressing the STANDBY mode. key, which sets the Base Unit to NOTE: The accuracy of the simulated SpO 2 saturation is a function of the FingerSim, not the SPO-2000 Base Unit. The SPO-2000 Base Unit only affects the Pulse Simulation rate. See the FingerSim Specifications for accuracy and related data. 5

MANUAL REVISIONS Revision # Rev 01 Rev 02 Rev 03 Rev 04 Revisions Made Origination Format Updated Misc. Edits Misc. Edits, Format Updated, Specifications Updated LIMITED WARRANTY WARRANTY: BC GROUP INTERNATIONAL, INC. WARRANTS ITS NEW PRODUCTS TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP UNDER THE SERVICE FOR WHICH THEY ARE INTENDED. THIS WARRANTY IS EFFECTIVE FOR TWELVE MONTHS FROM THE DATE OF SHIPMENT. EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BC GROUP INTERNATIONAL, INC. IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. NO PERSON OTHER THAN AN OFFICER IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR ASSUME ANY LIABILITY. REMEDIES: THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY SHALL BE: (1) THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS OR PRODUCTS, WITHOUT CHARGE. (2) AT THE OPTION OF BC GROUP INTERNATIONAL, INC., THE REFUND OF THE PURCHASE PRICE. P:\MANUALS\BCGroup\ \SPO-2000\SPO-2000_UM_Rev04.doc 6

SPECIFICATIONS SPO-2000 BASE UNIT PULSE SIMULATION RATE 30, 60, 90, 120, 150, 180 BPM ACCURACY ± 1% PHYSICAL, ENVIRONMENTAL, AND ELECTRICAL SIZE 5.20 x 5.20 x 2.50 Inches (132.1 x 132.1 x 63.5 mm) WEIGHT 1 Lbs (0.45 kg) CONSTRUCTION ENCLOSURE ABS Plastic FACE PLATE Lexan, Back printed OPERATING RANGE 15 to 40 C (59 to 104 F) STORAGE RANGE -20 to 65 C (-4 to 149 F) POWER 12 VDC, 500 ma 7

NOTES 8

BC GROUP INTERNATIONAL, INC. 3081 ELM POINT INDUSTRIAL DRIVE ST. CHARLES, MO 63301 USA 1-800-242-8428 1-314-638-3800 www.bcgroupintl.com sales@bcgroupintl.com SPO-2000 System User Manual 04/12 Rev 04 Copyright 2012 Made in the USA