NOMINAL SIZE A (mm) B (mm)

Similar documents
NOMINAL SIZE A (mm) B (mm)

NOMINAL SIZE. A (mm) B (mm) 8 X 6 8 X 8 8 X X

NOMINAL SIZE A (mm) B (mm)

NOMINAL SIZE. A (mm) B (mm) 8 x 6. 8 x x x

A (mm) B (mm) A (mm) B (mm) 12 x x x ft extension. 8ft extension ft extension ft extension 3720

A (mm) B (mm) A (mm) B (mm) 14 x x x ft extension. 8ft extension ft extension ft extension 3720

Extension Standard building 03/15

12 Wide Evolution Cedar Partition Assembly Instructions

8 Wide Evolution Cedar Partition Assembly Instructions

Extension Standard building 10/14

Cold Frame Instructions

8 Wide Victorian Cedar Greenhouse Assembly Instructions

6 Wide Victorian Cedar Greenhouse Assembly Instructions

6 Wide Victorian Cedar Greenhouse Assembly Instructions

8 Wide Victorian Cedar Greenhouse Assembly Instructions

10 Wide Victorian Cedar Greenhouse Assembly Instructions

10 Wide Victorian Cedar Greenhouse Assembly Instructions

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

6 Wide Victorian Cedar Greenhouse Assembly Instructions

6 Wide Evolution Cedar Greenhouse Assembly Instructions

8 Wide Evolution Cedar Greenhouse Assembly Instructions

Gardman Lean-to Greenhouse Assembly Instructions

Greenhouse Assembly Instructions

8 X 8 Extension ASSEMBLY INSTRUCTIONS TO BE USED IN CONJUNCTION WITH 8 WIDE INSTRUCTUIONS ISSUE: 2

GROWING BETTER THROUGH DESIGN LEAN-TO. Lean-To. Assembly Instructions 04/02

Zero Threshold TM. Hints and Tips Handbook. Birdlip. Burford. Blockley. Bourton

GROWING BETTER THROUGH DESIGN. Regent Royale Rosette Regal GREENHOUSE. Assembly Instructions 04/02

Assembly instructions. 6x4. Model GH1354A. 6x6. Model GH1357A. 6x8. Model GH1360A. 6x10. Walk-in Greenhouse. Model GH1363A


Walk-in Greenhouse. Assembly instructions. 8x6. 8x8. 8x10. 8x12. Model GH1399A Model GH1400A. Model GH1402A Model GH1403A. Model GH1405A Model GH1406A

Summer Greenhouses 6x8 GREENHOUSE 185. Assembly instructions for the. 6x8 Aluminium Greenhouse 185 PLEASE READ ALL INSTRUCTIONS BEFORE PROCEEDING

GREENHOUSE 6'x8' ASSEMBLY INSTRUCTIONS. (Internal Dimensions) Overall Dimensions (Approx.) L 193 W 200 H cms 97.5" L 76" W 78.

W6 series greenhouse

Additional help from 'The Greenhouse People'.

LAWN AND GARDEN GREENHOUSE

S H E D A S S E M B L Y I N S T R U C T I O N S

10 Wide AMATEUR CEDAR GREENHOUSE

SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF

LAWN AND GARDEN GREENHOUSE

Section. Page. Contents: - 1

GREENHOUSE EXTENSION 6 X4

Walk-in Greenhouse. Assembly instructions. 6x4. 6x6. 6x8. Model GH0490 Model GH0491 Model GH1040. Model GH0492 Model GH0493 Model GH1041

6 Wide AMATEUR CEDAR GREENHOUSE

6 5 Wide TRADITIONAL CEDAR GREENHOUSE

8 Wide AMATEUR CEDAR GREENHOUSE

Safety Glasses Safety Gloves Ladders Measuring Tape Spirit Level String Line. Tin-Snips Rivet Gun Caulking Gun Silicone Socket Set

S H E D A S S E M B L Y I N S T R U C T I O N S

DUTCH GABLE FREESTANDING CARPORT

8 Wide AMATEUR CEDAR GREENHOUSE

IMPORTANT!!! ASSEMBLY ASSEMBLY INSTRUCTIONS. (Internal Dimensions)

46, 66, Page /01/17

gabriel ash essential range

Taurean Sectional Garage Door INSTALLATION INSTRUCTIONS

10 Wide AMATEUR CEDAR GREENHOUSE

GrowSpan Estate Pro I Greenhouse

Elite Home-Attached Greenhouse

Version 2016_1.1 VICTORIAN ASSEMBLY INSTRUCTIONS. Victorian Vi-23, 34, 36

Installation Guide. Bi-fold Doors

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

INSTALLATION INSTRUCTIONS DANUBE ACRYLIC NEO ANGLE

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2

Gazebo GZ620H. Assembly Instructions. Systems Trading Corporation

6 x 6 OCTAGONAL CEDAR GREENHOUSE

ASSEMBLY INSTRUCTIONS

Easy2Build TM. 6 x 8 Easy-Grow Greenhouse. Assembly Instructions. Smart Tech solutions

Sliding Door Kit

Sauna & Steam. Traditional Sauna Installation Instruction Manual

Installation Guide Simplicity Alfresco. V1.9 Lu070318

Installation - Sub Cills

Roof Only Lean-to Instruction Manual

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

Clopay Models 835/837 Sliding Door System Installation Guide

Sliding Door Kit

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION

6X3 Patio Garden Shed Assembly Manual

Before fitting door, check opening size and squareness of timber frame. The door is made smaller to give correct clearance within the frame.

Pergola PR100N1. Assembly Instructions. Systems Trading Corporation Customer service: (877)

Potting Store Assembly Instructions

STRATCO GABLE HOMESHED STRATCO GABLE HOMESHEDS STUBBIE INSTALLATION GUIDE

Pvcu Bi Folding Doors Fitting Instructions.

Corner Potting Store Assembly Instructions

Installation Instructions. Walk-in Shower Screen. with 180 Return Panel

gabriel ash essential range

Renaissance. Assembly Instructions GREENHOUSE. for models BEFORE OPENING ANY OF THE BOXES PLEASE READ THESE INSTRUCTIONS 03/07

Portofino Installation Guide

Xenon 05 Installation Instructions & Parts List

Gambrel Barn Construction Manual 8x8 through 16x24 Units

PATIO INSTALLATION MANUAL

WARNING Please refer to all safety notices in the greenhouse manual before assembling any of the sections

ASS 70 FD folding/sliding door installation guide

Panoramic Door Block Frame Installation Manual

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

Twin-Wall Double Swinging Door Kit

Before Assembling the Storage Wall

ASS 70 FD folding / sliding door. Installation Guide

Grand Garden Chalet 6X3 Assembly Manual - Costco

Ultra Fast Delivery SGL Toilet Cubicle Pack Fitting Instructions

PVCu FOLD & SLIDE DOOR OUTWARD OPENING

Curium 19.4H Installation Instructions & Parts List

Deauville Installation Guide

Transcription:

NOMINAL SIZE A (mm) B (mm) 11 x 6 2012 11 x 8 2632 3536 11 x 10 3252 11 x 12 3872

Thank you for purchasing your new Robinsons greenhouse. We recommend you familiarise yourself with the instructions and read all safety information before you commence assembly. This instruction manual is also available online at www.robinsonsgreenhouses.co.uk in our technical help section should you need to reprint it. Should you require any additional advice you can always call us on 01782 385409. These instructions are divided into sections highlighted by a white number/letter on a black background at the bottom corner of most pages (see opposite page for details); part lists, B-base, P-preparation, 1-sides, 2-front gable, 3-rear, 4-joining the four sides together, 5-louvre, 6-roof, 7-vent, 8-glazing, 9- vent attachment, 10-door attachment, 11 anchoring down, 12 finishing touches, 13 optional shelf, 14 optional staging. If you need to contact us for assistance please refer to the relevant section/s. If your building is longer than 12, i.e. has an extension then please also refer the separate extension manual. Safety Warning Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when assembling and glazing the building. Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately. Do not assemble the greenhouse in high winds. For safety reasons and ease of assembly, we recommend that this greenhouse is assembled by a minimum of two people. Please clear all lying snow from the greenhouse roof as it can cause the roof to buckle or collapse. Site Preparation When selecting a site for your greenhouse, it is vital that you choose as flat and level an area as possible. A concrete or slabbed base will provide the most solid foundation for your greenhouse. IMPORTANT: Do not fix your building down until the building is fully assembled, including glazing. Avoid placing your greenhouse under trees or in other vulnerable locations. To minimise the risk of wind damage, try to select as sheltered a site as possible, e.g. beside a hedgerow or garden fence. Additional Considerations Please bear in mind that assembling your greenhouse can be time consuming. You may need to spread the construction over two or more days. We recommend that you avoid leaving the building partially glazed. If you ever have to leave your greenhouse half assembled and not anchored down, weigh it down with slabs or bags of sand to stop the wind moving it. You will find it helpful to prepare a large, clean and clear area in which to work in. A garage floor or flat lawn area is ideal. If you have arranged for someone to install your greenhouse for you, please check that all components are included. Most parts are numbered and can be identified by a stamped number (without the D ) or removable label. Alternatively, the components can be identified by lengths detailed in the packing list (see diagram below). Anchoring down your greenhouse should be the final stage of construction (including glazing). Once installed your greenhouse requires little maintenance, but to maintain the smooth running of your door(s) WD40 or similar can be applied to the door wheels and lower door guides. Guarantee Your new Robinsons greenhouse is guaranteed for 10 years against faulty manufacture of the framework. This does not include glazing, moving parts, accidental damage or wind damage. KEY SYMBOL KEY DESCRIPTION EXTERNAL VIEW INTERNAL VIEW THINK THIS SECTION RELATES TO ANOTHER (e.g. 1 to 5) CORRECT 639mm D866 DO NOT FIX DOWN! TWIST TO LOCK TIGHTEN PUSH AND HOLD CUT TO LENGTH 2

SECTION No TITLE ASSEMBLY SYNOPSIS: IMPORTANT INFORMATION / CONSIDERATIONS PARTS LIST Most components should have a D code punched into their metal surface. Identify and separate all like for like components prior to assembly. The parts list also separates parts into the various sections 1-12 shown below. Parts can also be identified by their profile pictures and stated lengths etc.. B P BASE Base dimensions and recommendations. Ensure that your base is level as this will make assembly of the building, especially the glazing of the roof much more straight forward. Please be aware that the hinge door on your greenhouse opens inwards, make sure that there will be no interference between the door and the foundations. PREPARATION Tools required. IMPORTANT: Use WD40 or similar in the glazing bar channels and insert the black glazing rubber prior to frame assembly. 1 SIDES 2 3 4 FRONT REAR JOINING THE FOUR SIDES 5 LOUVRE Take the side glazing bars D066 with the rubber inserted and the diagonal braces D103, use bolts to join them to the gutter and bolts to the cills (note how the head of the bolt slides into each glazing bar during construction). Please also remember to slide in your 22mm bolts for attaching the decorative eave spandrels DV100 in section 5. Again insuring that the gable framework is rubbered-up follow the diagrams to assemble each end of the building. Make sure that you have inserted the extra bolts utilised in sections 4 and 5. On the roof and side corner bars not every rubber channel will require rubber unless it is to be utilised in a partition (see separate manual and section P). Take the two sides (1) and both gables (2 & 3) and join them together on your base. It is a good idea to tie some ladders to the sides to support them if you do not have anyone to hold them for you. They attach to the building during the glazing process (8) like a piece of glass with a black separator above and below them. If you are fitting an optional auto-louvre then you need to carefully drill (3mm bit) out the rivets which mount the handle to the frame. You can then either utilise those holes or create more to mount the unit. 6 7a 7b ROOF VENT VENT SLAM 8 GLAZING Attach the ridge and then the rubbered-up roof bars ensuring that they are fully butted up to the ridge and down onto the gutter. Attach your cresting before you glaze the building to give yourself more room to work. Utilise the 22mm bolts slid into the side (section 1) and roof bars to attach your DV100 and DV101 spandrels. On longer models you may need to carefully prop up the roof and tie the sides together to keep the ridge and gutters straight (i.e. not sagging or bowed) until the building is fully glazed. Once the vent is glazed add silicone to the vent sides and top. Stand the vent/s on their hinge (vent top) and then leave the silicone to set. The slam bar D079 can be moved up and down between the roof glazing bars so that it can be butted down onto the pane of glass beneath, the autovent will be attached to it later on (9). Layout the bar cappings and covers around the building like a sundial checking that all is present and correct. You can also place the roof cappings in the gutters so they are closer to hand. The glass in the sides has to bevel on the black separator strip which is on top of the 305mm high glass base panels. This bevelling action allows the glass to tuck underneath the gutter canopy. Use the capping and the self tapping screws to then hold the glass in place. The covers then enclose the screw heads giving a neat finish. It is a good idea to glaze two roof sections first to ensure the building is square followed by two side sections to ensure the building isn't leaning. 9 10 VENT ATTACHMENT DOOR ATTACHMENT IMPORTANT: On the roof sections please make sure that you place a screw around 25mm / 1 from the bottom of each capping strip (create a hole in the plastic if required) and that the screws are nice and tight to avoid any glass slippage. Take the assembled vent and slide the vent hinge D866 into the end of the ridge allowing the vent the pivot open and closed. Vent stops go either side of the vent to stop any lateral movement (so insert stop / vent / stop). Attach the Bayliss XL autovents. Your door comes pre-constructed and locked minus the handles and their pivot pin but now it needs to be mounted to the front end of your building. Utilise the DV522 plates and twist in crop headed bolts to join the door and its frame to the building (pinch the door frame against your long front verticals whilst tightening your DV522 plates to ensure that there is no gap). If you are struggling to eradicate the gap between the door frame and verticals then some silicone can be carefully applied to the area to create a vertical seal. Be careful not to lock yourself in the building and to avoid damage do not open the door until it is attached to the front gable. Getting the door to swing perfectly without dropping or rubbing on the ground may require some small but vital adjustments. You may also need to insert a packer underneath the door frame hinge to increase ground clearance. Part DV275 canopies the door frame top hiding the clearance space at the top of the door. The door can only be made to swing inwards. IMPORTANT: Please do NOT let the door slam open or closed as it is likely to cause damage to the door and the frame. Please twist the handle to open and close. Please also be aware that your door KEYS (3 provided) are unique to the building so they should not be stored together. 11 ANCHORING DOWN 12 FINISHING TOUCHES Now that the greenhouse is finished and the door and vent/s are operating without interference then you need to anchor the building down using 2 rawl plugs and screws. Use a 7mm masonry bit in a hammer drill to create the holes. Now that the main body of the structure is complete you can add; downpipe fittings, eave bungs, gutter stop ends. It is also important to carefully apply some silicone to the internal eaves corners and external and internal ridge corners to minimise the chance of water entering the structure. 13 14 OPTIONAL SHELVING OPTIONAL STAGING Robinsons integral cantilever staging and shelving attaches to the inside of the greenhouse frame using either square head bolts (insert four into each side glazing bar D066 during construction of the sides (1)) or rectangular crop head bolts which can be fitted retrospectively (both sets of bolts accompany the shelving/staging). This system allows the height of either the staging or the shelf to be set at an operator specific height. Commonly the staging brackets are set 900mm from the cills though you can alter this to suit the end user/s. The aluminium shelf / staging slats come in two lengths; (4 ):1240mm D2002 and (6 ):1860mm D2003. These slats can combine to create any length of staging required, i.e. 4 +6 = 10 etc... 3

Section Ref Part No. Section Size (mm) 11 6 11 8 11 10 11 12 Section Ref Part No. Section Size (mm) 11 6 11 8 11 10 11 12 D043 1894 2 D021 2514 2 D022 3134 2 D023 3754 2 DV213 1897 2 DV210 2517 2 DV211 3137 2 DV212 3757 2 D103 1787 4 D066 1676 4 6 8 10 RUBBER 1000 (1m) 14 21 27 34 D174 N/A 4 4 8 8 DV275 904 1 D163 90 2 DV104 N/A 4 DV105 N/A 2 1000 RUBBER (1m) 94 D174 N/A 13 DV204 1897 1 DV201 2517 1 DV202 3137 1 DV203 3757 1 DV232 3548 1 DV255 2450 4 6 8 10 DV226LH 1 DV226RH 1322 1 RUBBER 1000 (1m) 20 30 40 50 D048 1676 4 D866 639 2 2 4 4 DV235LH 2 DV235RH 2021 2 DV237LH 2 DV237RH 2489 2 DV239LH 2 DV239RH 2960 2 D863L 613 2 2 4 4 D863R 613 2 2 4 4 DV262 3395 1 DV271LH 1 DV271RH 1249 1 D862 593 2 2 4 4 DV268 964 2 D079 PLUS FLUFF 590 2 2 4 4 DV274 3402 1 D114 N/A 4 4 8 8 DV292 1794 4 DV252LH 2 DV252RH 2450 2 D220 PLUS FS6060 SCREW N/A 4 4 8 8 DV264 1398 1 D205 N/A 4 4 8 8 4

Section Ref Part No. Section Size (mm) 11 6 11 8 11 10 11 12 Section Ref Part No. Section Size (mm) 11 6 11 8 11 10 11 12 5 D870 601 4 6 8 10 10 DV479 1384 1 2/3 DV635L/R 2021 2 + 2 2/3 DV637L/R 2489 2 + 2 2/3 DV639L/R 2960 2 + 2 5 DV655 1880 4 6 8 10 3 DV662 3395 1 2 / 10 DV664 1373 1 1 D812 1660 4 6 8 10 2/3 D813 1675 4 1 D834 1660 4 5 D871 601 4 5 DV652 1871 4 1 D825 1660 8 10 12 14 2/3 D826 1677 4 10 DV480 1384 1 2/3 DV636L/R 2021 2 + 2 2/3 DV638L/R 2489 2 + 2 2/3 DV640L/R 2960 2 + 2 5 DV658 2481 8 10 12 14 3 DV668 3395 1 2 / 10 DV670 1373 1 MAIN FRAME QUANTITIES DV219 N/A 2 DV218 N/A 2 VENTS / DOORS etc SEPERATE SYBOLM6X11 SYBOLM6X15 SYBOLM6X22 22mm SYNUTM6 M6 NUT 84 90 96 33 35 37 24 36 48 102 39 60 141 161 181 201 D522 N/A 10 D119 N/A 1 SILICONE DV120 N/A 4 D841 N/A 2 D211 PIPE 1625 2 D207 N/A 2 D214 N/A 2 D201 N/A 2 D208 N/A 2 5

THE DIMENSIONS BELOW ARE THE EXACT EXTERNAL BASE DIMENSIONS FOR THE ROBINSONS RANGE. We cannot emphasis how important it is to have a proper base for your Robinsons Greenhouse to be erected upon. It is essential that the BASE IS FLAT, LEVEL AND SQUARE AS WELL AS BEING SUBSTANTIAL enough to take the weight of the greenhouse including its 4mm glass. Give yourself enough room around your base to allow for fitting the glass and any on-going maintenance / cleaning. A slab base which is larger than the greenhouse is the ideal solution and is our preferred foundation. A brick perimeter base is equally suitable providing there is a concrete foundation beneath it. We suggest using a solid brick with no frogs or holes (quality stock bricks or semi-engineering bricks). IMPORTANT: Do not anchor your greenhouse down until it is fully assembled including glazing unless you are 100% sure your base is square and level. If not your glass will not fit properly. IMPORTANT: If you have anything overhanging the ridge on a lean-to building then please make sure it does not interfere with the motion of the roof vents. Longer building example (mm) External dimension of an 11x18 greenhouse. 11 x 12 main module (A) 3536 x (B) 3872 6 extension + (B) 2480 11 x 18 module (A) 3536 x (B) 6352 EXTERNAL DIMENSIONS (mm) 11 REIGATE VICTORIAN EXTENSIONS Model sizes listed are nominal, use mm measurements. i.e.: an 11 x 10 is the model 8'6" x 10' 8" MODEL A (mm) WIDTH B (mm) LENGTH C (mm) DIAGONAL 11 x 6 2012 4068 11 x 8 2632 4408 11 x 10 3536 3252 4804 11 x 12 3872 5244 6ft ext. - 1860-8ft ext. - 2480-10ft ext. - 3100-12ft ext. - 3720-6

Feed glazing rubber into each glazing bar and trim to length. Notice that some channels are only used on a partition. Applying a lubricant to the aluminium channels will speed up insertion. PARTITION ONLY REFER TO SEPARATE MANUAL PARTITION ONLY REFER TO SEPARATE MANUAL The frame is assembled by feeding square headed bolts, either or in length into the slots on glazing bars and then locating those bolts through holes in purlings and cills, etc Twist in (rectangular) crop headed bolts are also used towards the end of construction to attach components to the frame when the glazing bar slots are no longer exposed at the ends. 7

6 X 2 Part No mm Quantity DV213 1897 2 DV213 D043 1894 2 6 X 2 D066 1676 4 D103 1787 4 D174 4 SYBOLM6X11 4 SYBOLM6X15 SYBOLM6X22 8 8 D043 SYNUTM6 12 Rubber 1000 14 8 X 2 Part No mm Quantity DV210 2517 2 DV210 D021 2514 2 8 X 2 D066 1676 6 D103 1787 4 D174 4 SYBOLM6X11 6 SYBOLM6X15 SYBOLM6X22 10 12 D021 SYNUTM6 16 Rubber 1000 21 10 X 2 Part No mm Quantity DV211 3137 2 DV211 D022 3134 2 D066 1676 8 10 X 2 D103 1787 4 D174 8 SYBOLM6X11 8 SYBOLM6X15 SYBOLM6X22 12 16 D022 SYNUTM6 20 Rubber 1000 27 12 X 2 Part No mm Quantity DV212 3757 2 DV212 D023 3754 2 D066 1676 10 12 X 2 D103 1787 4 D174 8 SYBOLM6X11 10 SYBOLM6X15 SYBOLM6X22 14 20 8 D023 SYNUTM6 24 Rubber 1000 34

D103 D066 22mm TRANSIT BOLT ON DIAGONALS D066 D103 9

11 full front Part No mm Quantity D048 1676 2 DV226LH 1322 1 DV226RH 1322 1 DV235LH 2021 1 DV235RH 2021 1 DV237LH 2489 1 DV237RH 2489 1 DV239LH 2960 1 DV239RH 2960 1 DV252LH 2450 1 DV252RH 2450 1 Part No mm Quantity DV264 1398 1 DV268 964 1 DV271LH 1249 1 DV271RH 1249 1 DV275 904 1 DV292 1794 2 D163 2 DV104 2 DV105 1 D174 6 D227 45m M6X10 39 M6X15 12 DV252RH DV264 DV268 DV252LH M6NUT 51 DV275 DV271LH DV271RH D048 DV235RH DV292 DV237RH DV239RH DV226RH DV239LH DV237LH DV226LH DV292 DV235LH D048 10

DV252LH / DV252RH DV252RH DV252LH DV105 DV264 D163 DV275 DV252LH / DV252RH DV239LH / DV239RH DV271LH / DV271RH FLIP VIEW DV104 DV252LH / DV252RH D048 DV104 DV292 DV292 D048 DV239LH / DV239RH D174 DV226LH / DV226RH DV226LH / DV226RH 11

11 full rear Part No mm Quantity D048 1676 2 DV232 3548 1 DV235LH 2021 1 DV235RH 2021 1 DV237LH 2489 1 DV237RH 2489 1 DV239LH 2960 1 DV239RH 2960 1 DV252LH 2451 1 DV252RH 2451 1 DV262 3395 1 Part No mm Quantity DV268 964 1 DV274 3402 1 DV292 1794 2 DV104 2 DV105 1 D174 7 D227 49m M6X10 33 M6X15 13 M6NUT 46 DV252RH DV268 DV252LH DV239RH DV262 DV239LH DV274 D048 DV235RH DV292 DV237RH DV232 DV237LH DV292 DV235LH D048 12

DV252LH / DV252RH DV252RH DV105 DV262 DV252LH DV235LH / DV235RH DV239LH / DV239RH DV252LH / DV252RH DV274 FLIP VIEW DV104 DV252LH / DV252RH D048 DV104 DV292 DV292 D048 DV237LH / DV237RH D174 DV232 DV232 13

14 EQUAL

Part No mm Quantity D168L 552 1 D168R (handle) 552 1 D165 612 2 D166 552 2 FS6013 12 4 D166 D166 D168L D168R D165 D165 INTERNAL VIEW D729TG - 100 x 525 panes x 6 PINCH ALL GLASS RETAINERS BEFORE GLAZING 15 D165

6 8 10 12 Part No mm Quantity Part No mm Quantity Part No mm Quantity Part No mm Quantity DV204 1897 1 DV201 2517 1 DV202 3137 1 DV203 3757 1 DV255 2450 4 DV255 2450 6 DV255 2450 8 DV255 2450 10 DV100 n/a 4 DV100 n/a 6 DV100 n/a 8 DV100 n/a 10 DV101 n/a 2 DV101 n/a 3 DV101 n/a 4 DV101 n/a 5 RUBBER 1000 20 RUBBER 1000 30 RUBBER 1000 40 RUBBER 1000 50 SYBOLM6X11 8 SYBOLM6X11 12 SYBOLM6X11 16 SYBOLM6X11 20 SYBOLM6X22 16 SYBOLM6X22 24 SYBOLM6X22 32 SYBOLM6X22 40 SYNUTM6 32 SYNUTM6 48 SYNUTM6 64 SYNUTM6 80 End finials need to be pinched onto the ridge using DV282 grub screws. Depending on your ridge length a half cresting may need to be cut. Some spacer bar may also be required DV281 cut into two equal sections. CUT 6mm SILICONE D119 RO CRE ALU DV282 EQUALx2 ROFINALU DV281 16

2 1 2 1 DV255 DV255 DV255 22mm 22mm D066 4 3 4 DV101 3 DV100 DV100 17

Part No mm Quantity D866 639 1 Part No D220 PLUS SCREW mm Quantity N/A 2 D863L 613 1 D205 N/A 2 D1208 1 of - 610 x 610 pane D863R 613 1 D862 593 1 SY- BOLM6X11 10 4 SYNUTM6 M6 4 8 X 12 S/T FS6017 8 x 19 S/T FS6018 10 2 19 2 2 D863R 2 D863R D866 D863L D866 D1208 1 of - 610 x 610 pane 18

2 2 D862 D863L D862 2 FLIP VIEW 2 2 CUT 6mm SILICONE D119 19

Part No SY- BOLM6X11 SY- BOLM6X15 SYBOLM6 X11CROP mm Quantity 10 2 15 2 10 2 SYNUTM6 N/A 4 Part No mm Quantity D079 PLUS 590 1 FLUFF D114 N/A 2 D114 D079 D114 FLIP VIEW 20

GLAZING (plans pto): Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when assembling and glazing the building. Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately. D812 Layout the plastic bar cappings e.g. D812 and covers e.g. D825 around the building like a sundial checking that all is present and correct, see right and pto. You can also place the roof cappings in the gutters so they are closer to hand. The glass in the sides has to bevel on the black / white separator strip (see right) which is on top of the 305mm high glass base panels. This bevelling action allows the glass to tuck underneath the gutter and roof corner canopy. Use the capping e.g. D812 and the self tapping screws to then hold the glass in place. The covers then enclose the screw heads giving a neat finish e.g. D825. IMPORTANT: On the roof sections please make sure that you place a screw around 25mm / 1 from the bottom of each capping strip (create a hole in the plastic if required) and that the screws are nice and tight to avoid any glass slippage. 125 D825 S B 21

PART No Section Size (mm) D870 601 DV479 1384 DV670 DV635L/R 2021 DV664 DV637L/R 2489 DV639L/R 2960 DV640L DV640R DV655 1880 DV639L DV639R DV662 3395 DV664 1373 D812 1660 D813 1675 D834 1660 D871 601 DV636L DV635L DV638L DV637L ON DOOR DV480 DV479 DV638R DV637R DV636R DV635R DV652 1871 D826 D826 D825 1660 D826 1677 D813 D813 DV480 1384 DV636L/R 2021 DV638L/R 2489 DV640L/R 2960 DV658 2481 DV668 3395 D871 D870 D870 D870 D870 D870 D871 DV670 1373 DV658 DV658 DV658 DV658 DV658 DV658 DV658 DV652 DV655 DV655 DV655 DV655 DV655 DV652 D825 D825 D825 D825 D825 D825 D825 D834 D812 D812 D812 D812 D812 D834 DV668 DV662 DV640L DV640R DV639L DV639R DV638L DV637L DV638R DV637R DV636L DV635L DV636R DV635R D826 D813 D826 D813 22

ROOF PANES OVERLAP A A A A A A P K J H H J K R P R R R R R N G G D D G G N S S S S Q F F F F Q B B B B P Q K N G J G T T G G K P G N F F F F F F Q D906 D729 D101 / ROSEPS J G M 610 X 762 1 L 525 X 100 6 610 long 1 M L B PART No Size (mm) 6 8 10 12 D1206 S 610 X 1374 4 6 8 10 610x1890 R 610 X 1890 6 8 10 12 D1208 A 610 X 610 6 8 10 12 D1254 B 610 X 305 6 8 10 12 D904 N 305 X 1374 4 D905 Q 305 X 305 4 D770 F 457 X 305 10 D771 G 457 X 1374 10 DV700 D 357 X 1384 2 DV507 P ANGLE 4 DV713 K ANGLE 4 DV714 J ANGLE 4 DV716 T ANGLE 2 DV717 H ANGLE 2 D223/B Cut to 904mm 1 D101 / ROSEPS 610 long (inc cuts to 457&305mm) 32 34 36 38 1729 1262 1397 T 1272 J 805 H 940 794 K 337 325 P 20 457 457 457 457 305 23

D220 D220 24

D862 D079 25

DV499 DV495 DV494 DV498 DV497 DV479 DV480 DV700 DV700 DV478 DV496 DV495 DV500 DV495 DV499 26

Part No Quantity D522 10 SYBOLM6 X11CROP 20 SYNUTM6 20 DV522 DV275 27

O7mm 28

SILICONE D119 DV280 SILICONE DV120 D119 D048 D214 D841 D211 SILICONE D048 D207 D119 D201 D048 DV219 SHOWN DV219 SHOWN D208 CUT DV218LH / DV219RH D211 29

Part No SYBOLM6 X22CROP Quantity SYNUTM6 8 8 DV101 30

Example: 2x 4 3 slat shelves ST0304 = 8 run crop D2013 D048 D066 D048 D2014 crop D2002 =1240mm D2002 =1240mm D2003 =1860mm D2014 D2021 31

Example: 2x 4 7 slat staging ST0704 = 8 run D048 D066 D2045 D2043 D048 D2044 crop crop D2046 D2046 D2047 D2044 D2045 D2043 D2042 D2042 D2042 D2002 =1240mm FINISH D2002 =1240mm START D2003 =1860mm D2002 =1240mm 32

Example: 2x 4 10 slat staging ST01004 = 8 run D048 D174 D174 D048 D2045 D2043 D2051 D066 D2044 D2052 crop crop D2048 D2043 D2049 D2048 D2045 D2044 D2050 D2050 D2050 D2002 =1240mm START FINISH D2002 =1240mm D2052 D2003 =1860mm D2002 =1240mm 33

34

35

Please be aware that this is a new multi-national manual. If you spot any errors or have any constructive comments regarding the manual please email james@thegreenhousepeople.co.uk and I will make the necessary amendments. In addition any photographs of completed buildings would be most appreciated to add to our portfolio. Here s how you can earn 30 and have your new greenhouse feature in our next brochure. We are always interested to hear how you went on assembling your greenhouse, and we are particularly interested to see photos of the finished article. We like to see where you ve put it, how you re using it and how it looks in your garden. Often we glean ideas from this which we can pass on to other gardeners as useful tips. It is always nice if we can include real greenhouse photos in the brochure, so if you send us a photo of your greenhouse to us and it is good enough to get into our next brochure, we will send you a 30 reward. Please send your photos to: Photo competition Robinsons Greenhouses Blythe Park Cresswell Stoke-on-Trent Staffs ST11 9RD Or better still, email us on james.durose@greenhousepeople.co.uk Please write on the reverse of photos your name and address and if you would like them back, please write please return on them too. We wish you all the best with your new greenhouse, and we look forward to seeing your photos in the near future! THIS GREENHOUSE BOX WAS PACKED BY: DATE: www.robinsonsgreenhouses.co.uk To contact Robinsons Customer Services email us at sales@robinsonsgreenhouses.co.uk or call us on 01782 385 409. Our address is Robinsons Greenhouses, Unit 19 Blythe Park, Cresswell, Stoke-on-Trent, Staffordshire, ST11 9RD 36