Dual Protocol Transceivers Ease the Design of Industrial Interfaces

Similar documents
RS-232 Electrical Specifications and a Typical Connection

±50V Isolated, 3.0V to 5.5V, 250kbps, 2 Tx/2 Rx, RS-232 Transceiver MAX3250

+3.3V-Powered, EIA/TIA-562 Dual Transceiver with Receivers Active in Shutdown

DS485 Low Power RS-485/RS-422 Multipoint Transceiver

Serial Communications RS232, RS485, RS422

TD_485 Transceiver Modules Application Guide 2017

Design Considerations for High-Speed RS-485 Data Links

±80V Fault-Protected, 2Mbps, Low Supply Current CAN Transceiver

The Practical Limits of RS-485

DS485 Low Power RS-485/RS-422 Multipoint Transceiver

±80V Fault-Protected, 2Mbps, Low Supply Current CAN Transceiver

Appendix C RS-485 Network

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

Programmable RS-232/RS-485 Transceiver

Concept of Serial Communication

Programmable RS-232/RS-485 Transceiver

RS-485 Transceiver Tutorial

SP385A. +3V to +5V RS-232 Line Driver/Receiver. Operates from 3.3V or 5V Power Supply Meets All EIA-232D and V.28 Specifications

SP339E RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION

±15kV ESD-Protected, 3.0V to 5.5V, Low-Power, up to 250kbps, True RS-232 Transceiver

Summary of Well Known Interface Standards

SP334 SP334. Programmable RS-232/RS-485 Transceiver. Description. Typical Applications Circuit

INTEGRATED CIRCUITS. AN109 Microprocessor-compatible DACs Dec

SP483E. Enhanced Low EMI Half-Duplex RS-485 Transceiver

SP337E 3.3V TO 5V RS-232/RS-485/RS-422 MULTIPROTOCOL TRANSCEIVER

LMS75LBC176 Differential Bus Transceivers

XR3160E RS-232/RS-485/RS-422 TRANSCEIVER WITH 15KV ESD PROTECTION

LMS485 5V Low Power RS-485 / RS-422 Differential Bus Transceiver

DS3695/DS3695T/DS3696/DS3697 Multipoint RS485/RS422 Transceivers/Repeaters

FAILSAFE Biasing of Differential Buses

±15kV ESD-Protected, 460kbps, 1µA, RS-232-Compatible Transceivers in µmax

SP335E RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION

Transmission Line Drivers and Receivers for TIA/EIA Standards RS-422 and RS-423

Boost PROFIBUS RS-485 Robustness with GMR Isolation

RS-485 Isolator Raises the Bar for Bus Node Designs

UNISONIC TECHNOLOGIES CO., LTD UT232E Preliminary CMOS IC

Programmable Dual RS-232/RS-485 Transceiver

ISOV CC A B Y Z YR C1HI C2LO C2HI ISOCOM ±50V. C4 10nF. Maxim Integrated Products 1

T 3 OUT T 1 OUT T 2 OUT R 1 IN R 1 OUT T 2 IN T 1 IN GND V CC C 1 + C 1

Is Now A Part Of. Visit for more information about MaxLinear Inc.

+3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers

Differential Amplifiers

Low Power Half-Duplex RS-485 Transceivers

SP330E RS-232/RS-485/RS-422 TRANSCEIVER WITH 1.65V-5.5V INTERFACE

Kongsberg Mesotech Ltd.

UNISONIC TECHNOLOGIES CO., LTD UT232A Preliminary CMOS

SP3220E. +3.0V to +5.5V RS-232 Driver/Receiver Pair

TD_CAN Transceiver Modules Application Guide 2017

UNISONIC TECHNOLOGIES CO., LTD

Introduction. Protocol Definitions. The RS-485 Standard. APPLICATION NOTE 3884 How Far and How Fast Can You Go with RS-485?

MAX3316EAE -40 C to +85 C 16 SSOP C BYPASS CMOS INPUT CMOS OUTPUT. AutoShutdown Plus MAX3316. Maxim Integrated Products 1

DS275S. Line-Powered RS-232 Transceiver Chip PIN ASSIGNMENT FEATURES ORDERING INFORMATION

RS-485 Transceiver Tutorial

SP481E/SP485E. Enhanced Low Power Half-Duplex RS-485 Transceivers

Dual 16-Bit DIGITAL-TO-ANALOG CONVERTER

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

High Speed, +5 V, 0.1 µf CMOS RS-232 Drivers/Receivers ADM222/ADM232A/ADM242*

PART TOP VIEW TXD V CC. Maxim Integrated Products 1

Industry-Standard High-Speed CAN Transceivers with ±80V Fault Protection

Transmission Line Drivers and Receivers for TIA EIA Standards RS-422 and RS-423

+5 V Powered RS-232/RS-422 Transceiver AD7306

High-Speed, 5 V, 0.1 F CMOS RS-232 Drivers/Receivers ADM222/ADM232A/ADM242

The Practical Limits of RS-485

EL4089 and EL4390 DC Restored Video Amplifier

Implications of Slow or Floating CMOS Inputs

PART TOP VIEW V EE 1 V CC 1 CONTROL LOGIC

+3.3V, Multiprotocol, 3 Tx/3 Rx, Software- Selectable Clock/Data Transceiver

Digital Isolators: A Space-Saving Alternative to Gate-Drive Transformers in DC-DC Converters

LMS1487E Low Power RS-485 / RS-422 Differential Bus Transceiver

SP331 SP331. Programmable Dual RS-232/RS-485 Transceiver. Description. Typical Applications Circuit

SP483E. Enhanced Low EMI Half-Duplex RS-485 Transceiver RO 1 VCC RE 2 DE 3 DI 4 GND. Description. Block Diagram

High Speed, +5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203

3V RS-232 Serial Transceiver with Logic Selector and 15kV ESD Protection

IsoLoop Isolated QSOP RS-485 Transceiver Evaluation Board

Systems. Roland Kammerer. 29. October Institute of Computer Engineering Vienna University of Technology. Communication in Distributed Embedded

SP336E 3.3V - 5V PROGRAMMABLE RS-232/RS-485/RS-422 SERIAL TRANSCEIVER

ZT3485E Low Power 3V 250kbps/16Mbps RS485 Transceivers Zywyn Corporation

SP208EH/211EH/213EH High Speed +5V High Performance RS-232 Transceivers

MAX13051 ±80V Fault-Protected Can Transceiver with Autobaud

SP1481E/SP1485E. Enhanced Low Power Half-Duplex RS-485 Transceivers

SP339E RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION

+5V Multiprotocol, Software-Selectable Cable Terminator

AN-417 APPLICATION NOTE ONE TECHNOLOGY WAY P.O. BOX 9106 NORWOOD, MASSACHUSETTS /

DS90C032B LVDS Quad CMOS Differential Line Receiver

3.3 V, Full-Duplex, 840 μa, 20 Mbps, EIA RS-485 Transceiver ADM3491-1

RS-422/485 Application Note

DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION

Examining a New In-Amp Architecture for Communication Satellites

DS36C279 Low Power EIA-RS-485 Transceiver with Sleep Mode

change (PABX) systems. There must, however, be isolation between and the higher voltage, transientprone

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Concepts to be Reviewed

ML Volt Only Driver/Receiver with an Integrated Standby Mode RS 232/EIA 232 E and CCITT V.28

HA4600. Features. 480MHz, SOT-23, Video Buffer with Output Disable. Applications. Pinouts. Ordering Information. Truth Table

ITL Basics of Encoding and Wiring

LVDS Owner s Manual. A General Design Guide for National s Low Voltage Differential Signaling (LVDS) Products. Moving Info with LVDS

Low Power, 3.3 V, RS-232 Line Drivers/Receivers ADM3202/ADM3222/ADM1385

V6602H RS-485 Transceiver

How to Reconfigure a Buck Converter for Multiple Outputs

Transcription:

Dual Protocol Transceivers Ease the Design of Industrial Interfaces Introduction The trend in industrial PC designs towards smaller form factors and more communication versatility is driving the development of modern bus transceivers. New transceivers are favored over legacy designs because of their high level of integration, dual protocol capability supporting the RS-232 and RS-485 standards, and ample configuration features. This white paper discusses the industry s most commonly used interface standards, RS-232 and RS-485, reviews the functionality and features of a dual protocol transceiver, and discusses multi-protocol application examples, including the industrial PC. The RS-232 Standard RS-232 is a single-ended full-duplex interface, defined for point-to-point communication only. This means that one driver connects to one receiver, and, vice versa, one receiver connects to one driver. The interface requires a ground wire connection between driver and receiver grounds to provide a common reference for transmit and receive signals (Figure 1). Figure 1. Single-ended, point-to-point data link RS-232 tries to gain noise immunity through the use of high signal amplitudes. The standard uses inverse logic and specifies a logic zero, as a bus voltage from +3V to +15V, and a logic one from -3V to -15V (Figure 2). The range from +3V to -3V is undetermined. 1 Intersil

A B C Figure 2. RS-232 signal levels (A), their conversion from logic into bus signals (B), and an RS-232 transceiver with integrated charge-pump (C) Most of today s RS-232 designs use one or two data channels, with each channel consisting of a transmit and receive signal pair. Transceivers providing two channels can utilize one channel for data transmission and the other one for handshake control. Single-channel devices must resort to software flow control. The RS-232 standard specifies a maximum signal rate of up to 19.8kbps and a maximum slew rate of 30V/µs. However, by reducing the bus voltage amplitudes, modern transceivers can support data rates of up to 1Mbps without violating the slew rate specification. Although not specified, the maximum cable length is limited to around 30m. The RS-485 Standard Developed in the early 1980 s, RS-485 remains a drastically improved standard for robust data transmission in noisy environments and across long distances. The standard utilizes differential signaling across a signal pair of two conductors, A and B. It specifies a differential bus voltage swing between the two conductors of 1.5V minimum when loaded with a 54Ω differential load. Figure 3. Typical RS-485 network with daisy-chained bus nodes and terminated cable ends 2 Intersil

RS-485 supports networking of up to 32 unit-loads via a multipoint bus topology. Bus nodes are daisychained (Figure 3) to one another through twisted pair cable. The recommended characteristic cable impedance of 120Ω requires termination resistors at both cable ends, whose values should match the cable impedance. As the receiver inputs are internally referenced to ground, a separate ground connection between drivers and receivers is not required. This is, as long as the receiver input voltages do not exceed the specified common-mode voltage range of -7V to +12V. RS-485 supports cable lengths up to 4000ft (1200m) and data rates up to 10Mbps, but not simultaneously. The maximum applicable cable length for a given data rate follows a conservative cable-length-versus-datarate characteristic, as shown in Figure 4. Figure 4. RS-485 cable length versus data rate characteristic RS-485 supports multipoint topologies where each bus node can either transmit or receive data. Two types of multipoint buses exist: half-duplex and full-duplex (Figure 5). A half-duplex bus uses two wires across, where one node may transmit data while another node receives data. In a full-duplex bus, two signal pairs (four wires) are used. One pair connects the driver of the master node to the receivers of multiple slave nodes, and the other pair connects the drivers of the slave nodes to the receiver of the master node. This topology allows the master to either broadcast data to all slaves or address a specific slave node, while simultaneously receiving data from the slave nodes, one slave at a time. A full-duplex bus increases data throughput but is substantially more expensive than a half-duplex bus due to the higher wiring effort. Figure 5. Half-duplex and full-duplex multipoint bus topologies in RS-485 3 Intersil

Dual Protocol Transceivers Modern transceivers are capable of supporting the designs of new industrial PCs and the designs of RS-232 to RS-485/RS-422 interface converters. The latter is needed in existing RS-232 equipment, such as legacy PCs, instrumentation equipment, and industrial machinery, where interfaces must either be connected to a single network, or be extended over long distances. Figure 6 shows the block diagram of a dual protocol transceiver. The device incorporates two RS-232 transmit and receive channels and one full-duplex RS-485 transceiver. Notice the transceiver s flow-through pin-out with bus pins on one side and logic pins on the other. This allows for easy routing of signal traces to the local controller and presents a great advantage over legacy transceivers (as shown in Figure 3), whose pin-outs require the crossing of signal traces from the bus to the controller side and vice versa. Figure 6. Dual protocol transceiver incorporating one RS-485 and two RS-232 transceivers When operating the bus systems independently, each RS-232 port can support data rates of up to 400kbps without exceeding the specified slew rate maximum. The RS-485 section allows for the selection of a 20Mbps high-speed mode and a 115kbps slew rate limited mode via the /SLOW485 pin. In the high-speed mode the driver output is not slew rate limited. This mode should only be applied for distances shorter than 100ft (30m). The high-speed mode also requires the implementation of termination resistors at both cable ends, where the resistor values must match the characteristic cable impedance of either 120Ω for RS-485 cable or 100Ω for CAT-5 cable. 4 Intersil

Modern transceivers must be able to operate efficiently at low supply voltage. This is accomplished through an optimized charge pump design. The charge pump in Figure 6 creates the bipolar power supplies (V+, V-) for the RS-232 drivers, while only requiring four small 0.1μF capacitors. Two capacitors are used for the actual charge pump action converting the initial 3.3V at Vcc into +5V for V+ and -5.3V for V-. The other two capacitors are used for buffering V+ and V- to ensure sufficient supply current for the RS-232 driver during switching action. While total transceiver supply current is less than 4mA, further power savings can be achieved by driving the entire chip into a shut-down mode. This is accomplished by pulling the /SHDN pin low. In shut-down mode, charge pump operation ceases, and the remaining supply current only consists of the leakage currents flowing into the logic inputs. Thus, total leakage current depends on the device configuration but can be as low as 40μA. When re-enabling the device by taking /SHDN high, the charge pump takes up to 25μs to stabilize. RS-232 communication is not possible during this time. Since the charge pump does not supply the RS-485 transceiver, RS-485 communication can start 2μs after /SHDN was taken high. This timing is much faster than in legacy transceivers which require the charge pump for all modes of operation. Multi-Protocol Applications The integration of one RS-485 and two RS-232 transceivers into one IC makes the interface design of an industrial PC extremely versatile as the local controller can either drive the various bus systems independently, or act as an interface converter, as shown in Figure 7. When operated as an RS-232 to RS- 485 converter, the RS-232 signals of either channel 1 or channel 2, or both can be converted into logic levels and then transmitted via the RS-485 bus. Using address coding, the controllers on both sides of the RS-485 link can distinguish between two RS-232 data streams. Figure 7. Networking multiple RS-232 equipment via RS-232 to RS-485 converters To extend the data link between two RS-232 interfaces via a point-to-point link over long distance, the dual protocol transceiver is configured as a standalone RS-232 to RS-485 converter. Two converters are needed, one at each cable end to convert RS-485 bus signals into RS-232 data and vice versa. The configuration is simple as the enable inputs for driver and receiver can be fixed wired to their respective voltage rails to keep the transceiver constantly active (Figure 8A). 5 Intersil

A B Figure 8. Networking multiple RS-232 equipment via RS-232 to RS-485 converters Networking multiple RS-232 equipment over a full-duplex RS-485 bus requires a minor configuration change for the converters in slave nodes. The driver and receiver in the master node (PC) can remain active all the time, and so can the receivers in the slave nodes. The drivers in the slave nodes, however, must be closely controlled to prevent two or more slaves from accessing the bus at the same time. For this purpose, the driver of the second RS-232 channel is used to enable and disable the RS-485 driver with the RTS flow control signal (Figure 8B). Note that within the converter the RTS must be looped back to the CTS input of the controller. This is known as a null-modem configuration. A B Figure 9. Networking multiple RS-232 equipment via RS-232 to RS-485 converters Networking multiple RS-232 equipment over a half-duplex RS-485 bus requires the configuration shown in Figure 9A. Here the RTS signal controls the enable functions of both driver and receiver. This configuration is required in all nodes master and slaves because a half-duplex bus can only pass data in one direction at a time. In some equipment the RTS and CTS control signals can be up to 10ms out of sync with the data to be transmitted. In this case it is best to make the enable signals data-driven. This is accomplished by implementing an inverter function between the driver input (DI) and the enable pins (DE485 and /RE485). This puts the transceiver in transmit mode when DI = low, and in receive mode when DI = high. In receive mode the driver outputs are high-impedance, and the low-impedance termination resistors reduce the bus voltage to 0V. Since the RS-485 receiver is a full-failsafe device, all dual protocol transceivers on the bus will indicate a zero bus voltage as a logic high at the receiver output, RO. Thus, toggling a driver output between active low and high-impedance will still generate a low-to-high transition at another receiver s output. 6 Intersil

Conclusion Modern dual protocol transceivers simplify the design of industrial interfaces due to their high level of integration, combined support of RS-232 and RS-485 protocols, programmable data rates, and power-saving configuration features. To support system engineers in their industrial networking designs, Intersil provides a wide range of fixed and programmable, single and dual channel, multi-protocol transceivers. Next Steps Learn more about the Intersil s dual protocol transceivers Download the datasheets Order free samples About Intersil Intersil Corporation is a leader in the design and manufacture of high-performance analog, mixed-signal and power management semiconductors for the industrial and infrastructure, personal computing and high-end consumer markets. For more information about Intersil, visit our website at www.intersil.com. +1 408-432-8888 2016 Intersil Americas LLC. All rights reserved. Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries. All other trademarks mentioned are the property of their respective owners. 7 Intersil